• Title/Summary/Keyword: diagnostic system

Search Result 2,361, Processing Time 0.043 seconds

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

The ultrasonographic estimate of renal arteries in the dog (개에 있어서 신장혈관의 초음파적 평가에 관한 연구)

  • Kang, Suk-jae;Bae, Chun-sik;Kim, Hwi-yool;Chang, Kyung-jin
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.1
    • /
    • pp.230-239
    • /
    • 1999
  • Digital color doppler ultrasonographic system(DCDUS) has a lot of diagnostic functions. One of these is a detection of low velocity vessels in the organs of abdominal cavity. The purpose of study was to determine the clinical usefulness of DCDUS. Interlobar artery resistive index(RI), pulsatility index(PI) and systolic diastolic ratio(SDr) were measured for diagnosis of obstructed urinary tract. RI, PI and SDr were a measure of intrarenal blood flow impedance. This study was consisted of 2 groups. The normal group was studied in 16 normal adult dogs and the study group was studied 7 dogs with surgically induced, unilateral ureteral obstruction. In the study group, parameters were checked in normal condition and on 1, 2, 3, 5, 7 and 10th day after ligation. The result were summarized as follows. In the normal group, RI, PI and SDr of the left kidney was $0.65{\pm}0.04$, $1.25{\pm}0.12$ and $292.45{\pm}29.40$, respectively. RI, PI and SDr of the right kidney were $0.64{\pm}0.05$, $1.28{\pm}0.20$ and $282.25{\pm}37.26$, respectively. In the study group, RI of the left kidney induced ligation was increased significantly on 1, 2, 3, 5, 7 and 10th day. RI of the left kidney on 1, 2, 3, 5, 7 and 10th day were $0.75{\pm}0.05$, $0.71{\pm}0.03$, $0.74{\pm}0.04$, $0.74{\pm}0.02$, $0.73{\pm}0.02$ and $0.73{\pm}0.04$, respectively. PI of the left kidney was increased significantly on 1, 3, 5 and 7th day. PI of the left kidney on 1, 3, 5 and 7th day were $1.57{\pm}0.21$, $1.54{\pm}0.24$, $1.60{\pm}0.15$ and $1.60{\pm}0.26$, respectively. SDr of the left kidney increased significantly on 1, 2, 3, 5 and 7th day. SDr of the left kidney on 1, 2, 3, 5 and 7th day were $412.18{\pm}86.69$, $352.14{\pm}47.05$, $399.77{\pm}65.54$, $369.43{\pm}48.34$ and $365.57{\pm}22.46$, respectively(p<0.05). In the study group, RI of the left kidney was more increased than that of the right kidney on 1, 2, 3, 5, 7 and 10th day. PI of the left kidney was more increased than that of the right kidney on 1, 3, 5, and 7th day. SDr of the left kidney was more increased than that of the right kidney on 1, 2, 3, 5 and 7th day(p<0.05). RI was effective in the diagnosis of an acute unilateral ureteral obstruction. PI and SDr were insufficient in the diagnosis of an acute unilateral ureteral obstruction.

  • PDF

'Study on Oui-Ga-Sil( 胃家實 )' (위가실(胃家實)에 관(關)한 연구(硏究))

  • Han, Gyu-Eon;Ryu, Bong-Ha;Park, Dong-Won;Ryu, Gi-Won;Jang, In-Gyu
    • The Journal of Internal Korean Medicine
    • /
    • v.10 no.1
    • /
    • pp.65-80
    • /
    • 1989
  • About Oui-Ga-Sil(胃家實) in order to considerate the contents recorded in Nai-Gyung Sang-Han-Lon and latter literature, definition, etiopathology, syndrome, differential diagnosis, therapy, Prognosis and prevention were classified. And the results were as follows: 1. Oui-Ga(胃家)was a term which indicated the whole digestive system such as stomach, small intestine, large intestine, rectum and anus. Sil(實)could be defined as the peculiar concept pertaining to the acute and last stage which was invaded to inside bowels because of abundance with evil influence. 2. Eliology of Oui-Ga-Sil was abunt gastric fever originally, injured mucus because of mistreatment, the invasion to inside of outside evil influence through meridian. Pathology was the opening and shutting appearance of gastric abundance with intestinal emptiness, and intestinal abundance with gastric emptiness, Oui-Ga-Sil could be occurred because of gastric abundant dryness and splenic humidifying capacity decrease. 3. Symptom of Oui-Ga-Sil was classified as for the sunlight outside syndrome and the inside abundant syndrome. The sunlight outside syndrome was body fever, sweating, no chilling, on the contrary hatred of fever. The chief complaint of inside abundant syndrome was daily fever, talking in delirium, hand and foot sweating, abdominal distention, difficult defection and those could be pertained to sunlight bowel syndrome. 4. Diagnostic views of Oui-Ga-Sil were that pulse was descending abundant large strong and smooth quick, a coated tongue was yellow, deep yellow, old yellow, thick, scorching dry rough or gray black. On abdominal diagnosis, pressing by hand, patient was conscious of pain, excessive pain, rejection against press, impossible press or intermittent abdominal pain and bowel cutting pain without press. 5. Differential diagnosis was that the sunlight of Nai-Gyung-Fever-Theory was outside desease making meridian the prime object, Baik-Ho-Tang syndrome was making figureless abundant fever the pivotal point. And important differential standard of splenic shrink syndrome was that a daily fever, an irritation with fever were not occurred. 6. Theory of Oui-Ga-Sil was that Seng-Gi-Tang classes had been used in attacking downward or making balance, and moxibustion on Jung-Wan, honey boiling induction theory had been also used. Attacking downward therapy was invigorating method to preserve mucus, and if mucus had been exausted with complicating emptiness prognosis had been appeared badly. 7. Preventing from Oui-Ga-Sil diet by rule, fitness to cold and warmth may be needed to prevent outside evil influence attack and inside evil influence occurrence. Prudence with being very busy, fatigue, wine and woman may be also needed not to be an injury to splanic and gastric spirit.

  • PDF

Performance of Beam Extractions for the KSTAR Neutral Beam Injector

  • Chang, D.H.;Jeong, S.H.;Kim, T.S.;Lee, K.W.;In, S.R.;Jin, J.T.;Chang, D.S.;Oh, B.H.;Bae, Y.S.;Kim, J.S.;Cho, W.;Park, H.T.;Park, Y.M.;Yang, H.L.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.240-240
    • /
    • 2011
  • The first neutral beam injector (NBI-1) has been developed for the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. A first long pulse ion source (LPIS-1) has been installed on the NBI-1 for an auxiliary heating and current drive of KSTAR core plasmas. Performance of ion and neutral beam extractions in the LPIS-1 was investigated initially on the KSTAR NBI-1 system, prior to the neutral beam injection into the main plasmas. The ion source consists of a JAEA magnetic bucket plasma generator with multi-pole cusp fields and a set of KAERI prototype-III tetrode accelerators with circular apertures. The inner volume of plasma generator and accelerator column in the LPIS-1 is approximately 123 liters. Final design requirements for the ion source were a 120 kV/ 65 A deuterium beam and a 300 s pulse length. The extraction of ion beams was initiated by the formation of arc plasmas in the LPIS-1, called as an arc-beam extraction method. A stable ion beam extraction of LPIS-1 has been achieved up to an 100 kV/42 A for a 4 s pulse length and an 80 kV/25 A for a 14 s pulse length. Optimum beam perveance of 1.21 microperv has been found at an accelerating voltage of 80 kV. Neutralization efficiency has been measured by using a water flow calorimetry (WFC) method of calorimeter and an operation of bending magnet. The full-energy species of ion beams have been detected by using the diagnostic method of optical multichannel analyzer (OMA). An arc efficiency of the LPIS was 0.6~1.1 A/kW depending on the operating conditions of arc discharge.

  • PDF

Preventive Effects of Zinc Pretreatment in the Time-course of Cadmium-induced Testicular Toxicity in the Rat (아연 전처리가 시간 경과에 따른 카드뮴 유도 고환 독성에 미치는 보호 효과)

  • Jekal, Seung-Joo;Lee, Kyung-Sun;Chung, Ok-Bong;Im, Hyo-Bin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.3
    • /
    • pp.111-122
    • /
    • 2009
  • Cadmium (Cd) is known to exert gonadotoxic and spermiotoxic effects. The present study was performed to investigate the morphological effects and metallothionein (MT) expression by zinc pretreatment in the course of time of cadmium-induced testicular injury in rat. Fifty male Spraque-Dawley rats weighing 160~180 g were divided into two groups : saline-pretreated cadmium group and zinc-pretreated cadmium group. Rats of two groups received subcutaneous injection of saline and 100 mg/kg $ZnSO_4$ at 0, 2, 5 and 8 hrs intervals respectively. Cadmium chloride (4.5 mg/kg $CdCl_2$) was administrated intraperitoneally at 2 hrs after zinc injection and rats were killed 0, 12, 24, 48 and 72 hrs later. Testicular tissue damages, interstitial (Leydig) cells status and MT expression were determined using hematoxylin-eosin stained sections and a computerized image analysis system on sections immunostained with a mouse anti-metallothionein respectively. Zinc pretreatment was significantly reduced testicular damages in five pathological categories after cadmium administation. The number of surviving interstitial cells was significantly higher in the zinc-pretreated group than in the saline-preatreated group at 48 and 72 hrs after cadmium administration. Non-damaged testis showed the positivity of MT staining in spermatogenic cells, Sertoli cells and endothelium of blood vessel, but not in the Leydig cells. The positivity of MT staining in saline-pretreated group was significantly reduced at 24 hrs after cadmium administration, whereas zinc-pretreated group showed strong MT positive staining similar to the 0 hr by 42 hrs after cadmium administration. In damaged testis, MT positive staining was also observed in the Leydig cells of both groups. These results suggest that a major preventive effect of zinc against cadmium-induced testicular toxicity may be due to its ability to reduce the cytotoxicity of cadmium in spermatogenic cells and Leydig cells by inhibiting the susceptibility of the testis to cadmium but not MT production by cadmium.

  • PDF

Epidemiology Study of Patients with Neuropathic Pain in Korea (한국의 신경병성 동통 환자에 대한 역학조사)

  • Won, Jung-Yeon;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.4
    • /
    • pp.353-374
    • /
    • 2008
  • The descriptive epidemiology of specific neuropathic pain disorders has not been well-des-cribed, although the burden of neuropathic pain is well recognized. The true incidence of neuro-pathic pain disorder is unknown, but it is believed to be under diagnosed and treated inade-quately, despite the development of various diagnostic system. The purpose of this study was to report the epidemiology of specific neuropathic pain as managed by all kinds of hospital in Korea. A descriptive analysis of the epidemiology of prevalent trigeminal neuralgia(TN)(n-=77,053 27,6%), atypical facial pain(AFP)(n=12,382 4.4%), glossopharyngeal neuralgia(GN)-(n=1,319 0.5%), post-herpetic neuralgia(PHN)-(n=84,598 30.3%), diabetic neuropathy(DN)-(n=85,989 30.8%), atypical odontalgia(AO)-(n=16,001 5.7%) and glossodynia(GD)(n=2,133 0.8%) and treatment departments and treatment durations from computerized Health Insurance Review and Assessment Service(HIRA) of Korea: January 2003 to December 2005, are reported with rates increasing over time for PHN and DN and decreasing for the other neuropathic pain disorders. Most patients were treated at private clinic record for 57.6-72.8% of patients except OA for 10.3%. The percentage of Dept of dentistry for outpatients was 3.2% for TN, 34.7% for AO and 15.4% for GD. Other neuropathic pain patients visited nearly medical clinic.

Head motion during cone-beam computed tomography: Analysis of frequency and influence on image quality

  • Moratin, Julius;Berger, Moritz;Ruckschloss, Thomas;Metzger, Karl;Berger, Hannah;Gottsauner, Maximilian;Engel, Michael;Hoffmann, Jurgen;Freudlsperger, Christian;Ristow, Oliver
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.227-236
    • /
    • 2020
  • Purpose: Image artifacts caused by patient motion cause problems in cone-beam computed tomography (CBCT) because they lead to distortion of the 3-dimensional reconstruction. This prospective study was performed to quantify patient movement during CBCT acquisition and its influence on image quality. Materials and Methods: In total, 412 patients receiving CBCT imaging were equipped with a wireless head sensor system that detected inertial, gyroscopic, and magnetometric movements with 6 dimensions of freedom. The type and amplitude of movements during CBCT acquisition were evaluated and image quality was rated in 7 different anatomical regions of interest. For continuous variables, significance was calculated using the Student t-test. A linear regression model was applied to identify associations of the type and extent of motion with image quality scores. Kappa statistics were used to assess intra- and inter-rater agreement. Chi-square testing was used to analyze the impact of age and sex on head movement. Results: All CBCT images were acquired in a 10-month period. In 24% of the investigations, movement was recorded (acceleration: >0.10 [m/s2]; angular velocity: >0.018 [°/s]). In all examined regions of interest, head motion during CBCT acquisition resulted in significant impairment of image quality (P<0.001). Movement in the horizontal and vertical axes was most relevant for image quality (R2>0.7). Conclusion: Relevant head motions during CBCT imaging were frequently detected, leading to image quality loss and potentially impairing diagnosis and therapy planning. The presented data illustrate the need for digital correction algorithms and hardware to minimize motion artefacts in CBCT imaging.

Comparative seed morphology of the tribe Alsineae (Caryophyllaceae) in Korea and its taxonomic implications (한국산 Alsineae (석죽과) 종자의 형태비교 및 분류학적 유용성)

  • Song, Jun-Ho;Kim, Ju-Mi;Ok, Min-Kyoung;Hong, Suk-Pyo
    • Korean Journal of Plant Taxonomy
    • /
    • v.45 no.4
    • /
    • pp.369-379
    • /
    • 2015
  • The seed morphology of 25 taxa (8 genera) of Alsineae (Alsinoideae, Caryophyllaceae) in Korea was examined using stereo (SM) and scanning electron microscopy (SEM) in order to evaluate their diagnostic values and taxonomic implications. Circular, comma-shaped, ellipsoid, ovate, pyriform, reniform, and sub-circular seed shapes were identified. The seeds of the examined taxa range from 0.28 to 4.10 mm in length and from 0.33 to 3.10 mm in width; the smallest one was found in Sagina japonica, while the largest was in Honkenya peploides var. major. A hilar appendage was found in Cerastium, Honkenya, Moehringia, and strophioles were only observed in the genus Moehringia. Based on the examination of epidermal cells of the seed surface, four micromorphological types can be distinguished, viz., the colliculate-papillate (Col-Pap), colliculate-columellate (Col-Cll), colliculate-simple (Col-Sim), and smooth (Sm) types. Descriptions of the testa shape, margin, and the degree of elevation of the anticlinal cell walls, and the outer periclinal cell walls are summarized for the tribe. Taxonomic implications of the seed micromorphological characters were also discussed, in comparison with an earlier taxonomic system.

Comparison between QraypenTM Imaging and the Conventional Methods of Visual Inspection and Periapical Radiography for Proximal Caries Detection in Primary Molars: An In Vivo Study (유구치 인접면 우식 병소 진단에 있어 QraypenTM과 시진 및 구내 치근단 방사선의 비교)

  • An, So-Youn;Park, So-Young;Shim, Youn-Soo
    • Journal of dental hygiene science
    • /
    • v.16 no.5
    • /
    • pp.349-354
    • /
    • 2016
  • The purpose of this study was to evaluate the efficacy of the newly-developed $Qraypen^{TM}$ (All In One Bio, Korea) system for the diagnosis of early proximal caries by comparing it with the conventional methods of visual inspection and periapical radiography. This study was carried out from July 2015 to April 2016 targeting 32 children aged 7~12 years who visited Y-Dental Clinic for school oral health examinations. Two investigators selected and examined a total of 153 primary molars that had not undergone restorative treatment. Comparisons were carried out between visual inspections, readings of posterior periapical radiography images, and readings of $Qraypen^{TM}$ images. This study revealed that the percentage of interproximal surfaces of primary molar teeth without caries incidence was 83.7% using $Qraypen^{TM}$ imaging and 84.9% using visual inspection and periapical radiography. The differences between the two methods were not statistically significant. Thus, $Qraypen^{TM}$ is expected to be a useful and convenient auxiliary diagnostic device that can facilitate the detection of hidden proximal caries in primary molars.

Study on image quality improvement using Non-Linear Look-Up Table (비선형 Look-Up Table을 통한 영상 화질 개선에 관한 연구)

  • Kim, Sun-Chil;Lee, Jun-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.32-44
    • /
    • 2002
  • The role of radiology department has been greatly increased in the past few years as the technology in the medical imaging devices improved and the introduction of PACS (Picture Archiving and Communications System) to the conventional film-based diagnostic structure is a truly remarkable factor to the medical history. In addition, the value of using digital information in medical imaging is highly expected to grow as the technology over the computer and the network improves. However, the current medical practice, using PACS is somewhat limited compared to the film-based conventional one due to a poor image quality. The image quality is the most important and inevitable factor in the PACS environment and it is one of the most necessary steps to more wide practice of digital imaging. The existing image quality control tools are limited in controlling images produced from the medical modalities, because they cannot display the real image changing status. Thus, the image quality is distorted and the ability to diagnosis becomes hindered compared to the one of the film-based practice. In addition, the workflow of the radiologist greatly increases; as every doctor has to perform his or her own image quality control every time they view images produced from the medical modalities. To resolve these kinds of problems and enhance current medical practice under the PACS environment, we have developed a program to display a better image quality by using the ROI optical density of the existing gray level values. When the LUT is used properly, small detailed regions, which cannot be seen by using the existing image quality controls are easily displayed and thus, greatly improves digital medical practice. The purpose of this study is to provide an easier medical practice to physicians, by applying the technology of converting the H-D curves of the analog film screen to the digital imaging technology and to preset image quality control values to each exposed body part, modality and group of physicians for a better and easier medical practice. We have asked to 5 well known professional physicians to compare image quality of the same set of exam by using the two different methods: existing image quality control and the LUT technology. As the result, the LUT technology was enormously favored over the existing image quality control method. All the physicians have pointed out the far more superiority of the LUT over the existing image quality control method and highly praised its ability to display small detailed regions, which cannot be displayed by existing image quality control tools. Two physicians expressed the necessity of presetting the LUT values for each exposed body part. Overall, the LUT technology yielded a great interest among the physicians and highly praised for its ability to overcome currently embedded problems of PACS. We strongly believe that the LUT technology can enhance the current medical practice and open a new beginning in the future medical imaging.

  • PDF