Quality indicators in endoscopic retrograde cholangiopancreatography: a brief review of established guidelines

  • Zubin Dev Sharma;Rajesh Puri
    • Clinical Endoscopy
    • /
    • v.56 no.3
    • /
    • pp.290-297
    • /
    • 2023
  • Endoscopic retrograde cholangiopancreatography (ERCP) is an invasive endoscopic technique that has many diagnostic and therapeutic implications. It is a procedure with small but significant life-threatening complications. To ensure the best possible care, minimize complications, and improve the quality of health care, a constant review of the performance of the operator using ideal benchmark standards is needed. Hence, quality indicators are necessary. The American and European Societies of Gastrointestinal Endoscopy have provided guidelines on quality measures for ERCP, which describe the skills to be developed and training to be implemented in performing quality ERCP. These guidelines have divided the indicators into pre-procedure, intraprocedural, and post-procedure measures. The focus of this article was to review the quality indicators of ERCP.

A Method for Simultaneous Measurement of Air Kerma, Half Value Layer and Tube Potential in Quality Control Procedure of Diagnostic x ray units

  • Katoh, Tsuguhisa;Saitoh, Hidetoshi;Ohtani, Hiroki;Negishi, Tooru;Myojoyama, Atsushi;Ohno, Yuusuke;Sasaki, Takehito
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.294-297
    • /
    • 2002
  • For the quality control procedure of diagnostic x ray units, a method for simultaneous measurement of air kerma, half value layer and tube potential was developed utilizing a computed radiography system for intraoral radiography and film badge case. The response of average pixel values under the windows were calibrated by x rays generated at tube potentials from 40 to 140 kV with filtration from 1.5 to 3.7 mmAl. The calibration curves for half value layer and tube potential were derived as functions of attenuation factors by the 1.4 mmAl filter and the 0.2 mmCu filter. The energy dependency of the open window response was corrected by the calibration factor as a function of the attenuation factor by the 1.4 mmAl filter. The uncertainty of the estimated half value layer, tube potential and air kerma were 0.2 mmAl, 3.6 % and 5 %, respectively. It was thus suggested that this system could be applied to quality control program to detect the variation of working condition of x ray units in clinical use.

  • PDF

Reproducibility of lateral cephalometric landmarks on conventional radiographs and spatial frequency-processed digital images

  • Shin Jeong-Won;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Hyun-Bae;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.32 no.4
    • /
    • pp.213-219
    • /
    • 2002
  • Purpose : Computed radiography (CR) has been used in cephalometric radiography and many studies have been carried out to improve image quality using various digital enhancement and filtering techniques, During CR image acquisition, the frequency rank and type affect to the image quality. The aim of this study was to compare the diagnostic quality of conventional cephalometric radiographs to those of computed radiography. Materials and Methods : The diagnostic quality of conventional cephalometric radiographs (MO) and their digital image counterparts were compared, and at the same time, six modalities (M1-M6) of spatial frequency-processed digital images were compared by evaluating the reproducibility of 23 cephalometric landmark locations. Reproducibility was defined as an observer's deviation (in mm) from the mean between all observers. Results and Conclusion: In comparison with the conventional cephalometric radiograph (MO), Ml showed statistically significant differences in 8 locations, M2 in 9, M3 12, M4 in 7, M5 in 12, and M6 showed significant differences in 14 of 23 landmark locations (p < 0.05). The number of reproducible landmarks that each modality possesses were 7 in M6, 6 in M5, 5 in M3, 4 in M4, 3 in M2, 2 in Ml, and 1 location in MO. The image modality that observers selected as having the best image quality was M5.

  • PDF

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

Evaluation of the Quality of Case Reports in Journal of Oriental Neuropsychiatry Using CARES Guideline (CARES 지침에 따른 동의신경정신과학회지의 증례보고에 대한 질 평가 연구)

  • Lee, Hwan Seong;Lee, Junyeop;Han, Ji Han;Chae, Han
    • Journal of Oriental Neuropsychiatry
    • /
    • v.30 no.2
    • /
    • pp.59-69
    • /
    • 2019
  • Objectives: Case report is a description of medical experience that contains a patient's information and treatments. It has been used to determine the effectiveness and side effect of the treatments. Case report can be used for medical, scientific, or educational purposes. The objective of this study was to evaluate the quality of case reports published in Journal of Oriental Neuropsychiatry from 2013 to 2017 using CARE and CARES guideline. Methods: Case reports were selected from Journal of Oriental Neuropsychiatry and their quality assessed using CARE guideline and CARES guideline. The items of CARE and CARES guideline were assessed as 'Sufficient', 'Not sufficient', 'Not reported', 'Not applicable'. The outcome was analyzed using case reports and items. Results: 26 case reports were selected. For CARE guideline, 'Sufficient' percentage was min at 22.2%, max at 46.4% with a median of 39.3%. Sum of 'Sufficient', 'Not sufficient' percentage was min at 59.3%, max at 85.7% with a median of 75.0%. Items 'Timeline', 'Diagnostic assessment', 'Follow up and outcomes', 'Informed consent' were not reported in more than 50% of all case reports. Items 'Keywords', 'Abstract', 'Introduction', 'patient information', 'Diagnostic assessment', 'Therapeutic interventions', 'Follow up and outcomes' were not sufficiently reported in more than 50% of all case reports. For CARES guideline, 'Sufficient' percentage was min at 0%, max at 50% with a median of 0%. Sum of 'Sufficient', 'Not sufficient' percentage was min at 33.3%, max at 100% with a median of 92.9%. Items of herbal prescription 'herb', 'decoction', 'use', items of acupuncture treatment 'materials', 'techniques', items of moxibustion treatment 'materials', 'techniques' were not sufficiently reported in more than 50% of all case reports. Conclusions: The reporting rate of items was good. But the quality of reporting was low. Also, particular items were not reported frequently. Therefore, there is a need to improve the quality of case reports in Journal of Oriental Neuropsychiatry.

The Study of Neck Lateral Projections Using for Al Compensation Filter (Al compensation filter를 이용한 경부 측방향촬영에 관한 고찰)

  • Jang, Young-Ill;Lee, Seong-Gil
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.11-15
    • /
    • 1992
  • For improving the image quality in case of neck Lateral projections, the Al compensation filter were used and conclusion that, it could be got the high image quality able to observe the shadow of cervical spine, hyoid bone, trachea, soft tissue simultaneously.

  • PDF

A Study on Sensitivity Analysis in Ridge Regression (능형 회귀에서의 민감도 분석에 관한 연구)

  • Kim, Soon-Kwi
    • Journal of Korean Society for Quality Management
    • /
    • v.19 no.1
    • /
    • pp.1-15
    • /
    • 1991
  • In this paper, we discuss and review various measures which have been presented for studying outliers, high-leverage points, and influential observations when ridge regression estimation is adopted. We derive the influence function for ${\underline{\hat{\beta}}}\small{R}$, the ridge regression estimator, and discuss its various finite sample approximations when ridge regression is postulated. We also study several diagnostic measures such as Welsh-Kuh's distance, Cook's distance etc.

  • PDF

A case-by-case version of CB statistic in biased estimation

  • Ahn, Byoung Jin
    • Journal of Korean Society for Quality Management
    • /
    • v.19 no.2
    • /
    • pp.40-51
    • /
    • 1991
  • The $C_B$ statistic, a generalization of Mallows's $C_L$ statistic, is developed to determine the shrinkage parameter. Since not all cases in a data set play an equal role in forming $C_B$, a subdivision of $C_B$ into individual components for each case is developed. This subdivision is useful both as an aid in understanding $C_B$ and as a diagnostic procedure.

  • PDF

Diagnostic X-ray Spectra Detection by Monte Carlo Simulation (진단용 X-선 스펙트럼의 몬테칼로 전산모사 측정)

  • Baek, Cheol-Ha;Lee, Seung-Jae;Kim, Daehong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.289-295
    • /
    • 2018
  • Most diagnostic devices in the medical field use X-ray sources, which emit energy spectra. In radiological diagnosis, the quantitative and qualitative analyses of X-rays are essential for maintaining the image quality and minimizing the radiation dose to patients. This work aims to obtain the X-ray energy spectra used in diagnostic imaging by Monte Carlo simulation. Various X-ray spectra are simulated using a Monte Carlo simulation tool. These spectra are then compared to the reference data obtained with a tungsten anode spectral model using the interpolating polynomial (TASMIP) code. The X-ray tube voltages used are 50, 60, 80, 100, and 110 kV, respectively. CdTe and a-Se detector are used as the detectors for obtaining the X-ray spectra. Simulation results demonstrate that the various X-ray spectra are well matched with the reference data. Based on the simulation results, an appropriate X-ray spectrum, in accordance with the tube voltage, can be selected when generating an image for diagnostic imaging. The dose to be delivered to the patient can be predicted prior to examination in the diagnostic field.

Research of Developing of Standards for Electronic Thermometers (전자식체온계 기준규격 개발 연구)

  • Kim, E.J.;Lee, M.J.;Lee, B.Y.;Park, K.G.;Kim, D.S.;Lee, I.S.;Park, H.D.;Jeong, H.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.123-128
    • /
    • 2010
  • The thermometers is widely used in diagnostic medical devices, and the safety and accurate performance of these devices are important in the diagnosis and monitoring of personal health. Especially, the accuracy of infra-red thermometer is highly emphasized. Here two typical thermometers are utilized for this purpose: the electronic thermometers measure body temperature by contacting to subject while infra-red thermometers measure by no contacting to subject. Therefore, the evaluating items of each thermometer are different, and the standard for each temperature is highly needed. But, there have been no international standards of each thermometer such as IEC. In this paper, we developed the standards of electronic and infra-red thermometer based on national standards such as KS, ASTM, EN, JIS and FDA guidance. The new standards focused on the safety and suitable performance for health care. This standards were applied to enact and revise the electronic medical device standards. So it can be applied to evaluate the safety and performance on technical file review. We predict that this standard will improve the quality of diagnostic medical devices (thermometers) and increase the international competitive power of domestic product.