• 제목/요약/키워드: diagnostic point

검색결과 474건 처리시간 0.023초

Review on Diagnostic Criteria of Neurasthenia : Suggesting Pathway of Culture-bound dieases

  • Lee, Myeong Hun;Kim, Yunna;Cho, Seung-Hun
    • 대한약침학회지
    • /
    • 제20권4호
    • /
    • pp.230-234
    • /
    • 2017
  • Objective: Neurasthenia is a disease which consists of increased fatigue or bodily weakness and exhaustion plus pantalgia, dizziness, headache and other symtoms relevant to autonomic nerve dysfunction. There are plenty of studies investigating the history of diagnostic criteria of neurasthenia, which is influenced by diverse cultural(or social) environment. The obejective of this study is to provide review of the previous studys on the changes of neurasthenia diagnoses in the context of local area to find meanings of these transition and improve health care for psychiatric patient. Methods: Literature review was conducted on studies demonstrating diagnostic criteria of neurasthenia with cultural(or social) environment. We investigated the literature reviews or observative studies which described alteration of diagnostic criteria of neurasthenia and assessed its significance. After selecting eligible studies, the authors read the articles and summarized the meaningful contents those were significant in clinical practice. Results: Transformation of Chinese Classification of Mental Disorder(CCMD) integrated with internationally utilized DSM-IV or ICD-10 is controversial about its significance in that it had limited effect on public health care due to the variables of sociocultural context, but primarily differentiated neurasthenia from other disorders. The latter one can be the directing point of the diagnostic criteria of other culture-bound diseases, which is the traits of not outstanding mood(or affect) than other neurotic disorders. Conclusion: As diagnostic criteria of neurasthenia varies, the significance of this variation is controversial, but could be the paragon of other culture-bound diseases.

Kodak Insight 구내필름의 치아우식증 진단능에 대한 연구 (Diagnostic accuracy of Insight intraoral film on dental caries)

  • 윤영남;이상래;이병도
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.19-23
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy of Kodak Insight film with other intra-oral films in the detection of dental caries. Materials and Methods : Periapical radiographs of 99 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were made on Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Kodak Insight films and automatically processed. Six dentists examined the presence of dental caries using a five-point confidence rating scale and compared the diagnostic accuracy by ROC (Receiver Operating Characteristic) analysis and ANOVA test. Results: The sensitivity of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.84, 0.77, 0.75 and 0.79 respectively. The specificity of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.97. 0.95. 0.96 and 0.94 respectively. The mean ROC areas (Az) of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.917, 0.910, 0.894, 0.909 respectively. There was no significant differences between Az of Insight film and other films (p = 0.178). Conclusion: Theses results suggested that Kodak Insight film have the comparative diagnostic accuracy of dental caries with Ultraspeed and Ektaspeed films.

  • PDF

치아 우식증 진단시 필름 방사선사진상과 디지털 방사선영상의 비교:CCD, CMOS, PSP와 film (A comparison of film and 3 digital imaging systems for natural dental caries detection: CCD, CMOS, PSP and film)

  • 한원정
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.1-5
    • /
    • 2004
  • Purpose: To evaluate the diagnostic accuracy of occlusal and proximal caries detection using CCD, CMOS, PSP and film system. Materials and Methods : 32 occlusal and 30 proximal tooth surfaces were radiographed under standardized conditions using 3 digital systems; CCD (CDX-2000HQ, Biomedysis Co., Seoul, Korea), CMOS (Schick, Schick Inc., Long Island, USA), PSP (Digora/sup (R)/FMX, Orion Co./Soredex, Helsinki, Finland) and I film system (Kodak Insight, Eastman Kodak, Rochester, USA). 5 observers examined the radiographs for occlusal and proximal caries using a 5-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (Az). Results: Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. For occlusal caries, Kodak Insight film had an Az of 0.765, CCD one of 0.730, CMOS one of 0.742 and PSP one of 0.735. For proximal caries, Kodak Insight film had an Az of 0.833, CCD one of 0.832, CMOS one of 0.828 and PSP one of 0.868. No statistically significant difference was noted between any of the imaging modalities. Conclusion: CCD, CMOS, PSP and film performed equally well in the detection of occlusal and proximal dental caries. CCD, CMOS and PSP-based digital images provided a level of diagnostic performance comparable to Kodak Insight film.

  • PDF

척추수술 후 증후군 환자에서 관찰된 추간관절통에 대한 고주파신경절리술 (Raiofrequency Neurotomy for Lumbar Facet Joint Pain in the Patients with Failed Back Surgery Syndrome)

  • 이정훈;심재철
    • The Korean Journal of Pain
    • /
    • 제18권2호
    • /
    • pp.151-155
    • /
    • 2005
  • Background: A significant number of patients complain of persistent pain or neurologic symptoms after lower back surgery. It is reported that facet joint pain plays a role in failed back surgery syndrome. To the best of our knowledge, there are few studies that have investigated the outcome of radiofrequency neurotomy in the patients with failed back surgery syndrome. Methods: The study group was composed of thirteen patients who were operated on due to their low back pain, and they displayed no postoperative improvement. All the patients underwent double diagnostic block of the lumbar medial branch of the dorsal rami with using 0.5% bupivacaine. The patients who revealed a positive response to the double diagnostic block were then treated with percutaneous radiofrequency neurotomy. The effect on their pain was evaluated with using a 4 point Likert scale. Results: Eleven patients revealed a positive response to the double diagnostic block. Ten patients were given percutaneous radiofrequency neurotomy. Nine patients showed sustained pain relief for 3 months after the percutaneous radiofrequency neurotomy. Conclusions: We found lumbar facet joint syndrome in the patients with failed back surgery syndrome by performing double diagnostic block and achieving pain relief during the short term follow-up after percutaneous radiofrequency neurotomy of the lumbar zygapophysial joints. This suggested that facet joint pain should be included in failed back surgery syndrome.

이동통신망의 SMS 방식을 이용한 주상변압기 무선 진단 기법 (Wireless Diagnostic Technique for Pole Transformer Using SMS of Mobile Telecommunication Network)

  • 김진철;이향범
    • 정보통신설비학회논문지
    • /
    • 제2권3호
    • /
    • pp.61-71
    • /
    • 2003
  • 본 논문에서는 이동통신망의 SMS 방식을 이용하여 소용량 변전기기인 주상 변압기의 상태를 진단함으로써 발생 가능한 변압기의 사고를 사전에 방지할 수 있는 시스템에 관하여 연구하였다. 변압기의 전류와 온도를 취득하여, 과부하 상태의 값들을 평균과 표준편차로 정리하여 보내는 방식의 무선진단에 적합한 알고리즘 및 프로토콜을 설계하였다. 이동통신망의 SMS방식을 이용하여 유선의 단점인 설치장소에 대한 장애를 없앴다. 또한, 1대의 서버로 많은 수의 변압기를 관리, 제어, 모니터링이 가능하도록 하였다.

  • PDF

고압전동기 고정자 권선의 절연열화 평가 (Assessment of Insulation Deterioration in Stator Windings of High Voltage Motor)

  • 김희동;공태식
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.711-716
    • /
    • 2012
  • To assess the insulation deterioration of stator windings, diagnostic and AC breakdown tests were performed on the eleven high voltage (HV) motors rated at 6kV. After completing the diagnostic tests, the AC overvoltage test was performed by gradually increasing the voltage applied to the stator windings until electrical insulation failure occurred, to obtain the breakdown voltage. Stator winding of motors 1, 3, and 8 failed at above rated voltage at 14 kV, 13.8kV, and 16.4kV, respectively. The breakdown voltage of three motors was higher than expected for good quality windings in 6kV motors. Based on deterioration evaluation criteria, the stator winding insulation of eleven HV motors are confirmed to be in good condition. The turning point of the current, $P_{i2}$, in the AC current vs. voltage characteristics occurred between 5kV and 6kV, and the breakdown voltage was low between 13.8kV and 16.4kV. There was a strong correlation between the breakdown voltage and various electrical characteristics in diagnostic tests including Pi2.

갱년기장애 및 폐경기증후군 변증진단 도구의 진단결과 도출을 위한 변증별 절단점 연구 (A Clinical Study on the Pattern-Specific Cut-Point for the Pattern Identification Diagnostic Tool for Climacteric and Postmenopausal Syndrome)

  • 이인선;김종원;전수형;지규용;강창완
    • 대한한방부인과학회지
    • /
    • 제32권2호
    • /
    • pp.29-49
    • /
    • 2019
  • Objectives: This study was a methodological study to verify the reliability and validity and to make a diagnosis of a diagnostic tool for climacteric and postmenopausal syndrome pattern identification (CaPSPI). Methods: This study was conducted from June 1, 2018 to October 18, 2018 with ${{\bigcirc}{\bigcirc}}$ University Korean Medicine Hospital IRB's approval (2018-3). To make a diagnosis using CaPSPI, we decided the cut-points for the tool. Three professors of ${{\bigcirc}{\bigcirc}}$Korean Medical University conducted pattern identification diagnosis. The result is marked from 0 to 3, 0 is 'No', 1 is 'Slightly Yes', 2 is 'Yes' and 3 is 'Very Yes'. And if two or more professors' diagnoses are the same, we took the diagnoses as a diagnostic criteria. The decision of pattern by three experts converted to 0-1 scores in two ways. In "method 1", if the diagnosis was zero points, the score was 0 (have no such identification), and the rest was 1 (have such identification). In "method 2", if the diagnosis was zero or 1 point, the score was 0, and the rest was 1. After that, intraclass correlation was calculated for experts agreement. And logistic regression was conducted. A response variable was the results of the experts' diagnosis and an explanatory variable was the results of the pattern identification diagnostic tool. Results: The diagnosis of the three experts showed excellent concordance of more than 0.794 and showed a significant correlation with the diagnostic tool. Both 'Method 1' and 'Method 2' showed statistically significant effects with the diagnosis of 3 experts and the results of the diagnostic tool. The frequency of cumulative pattern identification diagnosis in 'Method 1' and 'Method 2' were found to be 578 occasions and 203 occasions, respectively. The average number of pattern held by participants in 'Method 1' and 'Method 2' were found to be 5.26 and 1.85, respectively. In both "Method 1" and "Method 2," the yield frequency of liver qi depression was the highest, and the frequency of kidney yin deficiency and liver-kidney yin deficiency was relatively high. Conclusions: Based on the above results, it is thought that, in diagnosis using CaPSPI of menopausal women, 'method 1' could be used for the health diagnosis and prevention, 'method 2' could be used for the pattern diagnosis. On the conclusion, CaPSPI is thought to be available for pattern diagnosis of menopause women.

간이형 상시 GIS 진단장치 (Simplified GIS Diagnostic SYSTEM)

  • 정재기;최윤종;강창익;장훈기;곽희섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.74-77
    • /
    • 2006
  • This research is focused on the development of GIS Diagnostic SYSTEM to prevent accidents beforehand by inspecting the internal defects of GIS (Gas Insulated Switchgear) which is a main power-facility for substations. GIS Diagnostic SYSTEM is categorized as 'Real time on-line test type' and 'Portable test type' depending on the types of testing, it uses PD(partial discharge) which mostly incurs in GIS internal defects, to inspect. As of now, mostly foreign equipments are imported for use due to the lack of the technology localization, and these are installed and operated on only some parts of highly-graded GIS power-facilities such as in 76skv or 345kv for its being expensive. Furthermore, other than foreign equipments being costly, it also has a weak point of very long unavailability in case of Diagnostic system break-down while using, because it takes a comparatively long period of corrective maintenance precesses. We have localized to develop personal real-time multi -functional GIS Diagnostic system which can test on all GIS power-facility comprehensively and economically therefore overcome all these problems mentioned above, a market expansion is expected from the decrease of price and replacing the import equipments in the future. As the equipment was developed to be Personal for the simple ways of installing and utilizing, it can be operated without any complex cable installation like other existing GIS Diagnostic system requires, therefore also decrease the cost of cable installation.

  • PDF

상악동의 점막비후에 대한 WATERS방사선사진과 파노라마방사선사진 및 전산화단층사진의 진단능 비교 (Comparison of Waters′ radiography, panoramic radiography, and computed tomography in the diagnosis of antral mucosal thickening)

  • 현영민;이삼선;최순철
    • 치과방사선
    • /
    • 제28권1호
    • /
    • pp.261-269
    • /
    • 1998
  • With the CT findings as gold standard, the sensitivity, the specificity, and the diagnostic accuracy of Waters' radiography and Waters' radiography with panoramic radiography were compared in the diagnosis of antral mucosal thickening of 16 patients. Three oral radiologists and three non-oral radiologists interpreted the Waters' radiographs and after 4 weeks, interpreted the Waters' radiographs and panoramic radiographs simultaneously. The interpretation point was the existence or the non-existence of the mucosal thickening on the medial, the posterolateral, the floor, and the roof of maxillary sinus. The obtained results were as followed : 1. In oral radiologist group, the sensitivity, specificity and diagnostic accuracy of Waters' film were 0.7250, 0.8489 and 0.7578 respectively. 2. The sensitivity and the diagnostic accuracy in oral radiologist group were higher than those of non-oral radiologist group (P<0.05), but there was no significant difference between two groups in the specificity (P>0.05), 3. There was no significant difference of the diagnostic abilities except the specificity in oral radiologist group between Waters' radiography and Waters' radiography with panoramic radiography (P>0.05). 4. The sensitivity and the diagnostic accuracy were the highest in the case of medial wall interpretation, the specificity was the highest in the posterolateral wall. 5. In the posterolateral wall and the floor, the sensitivity and the diagnostic accuracy of oral radiologist group were higher than those of non-oral radiologist group (P<0.05).

  • PDF

Diagnostic accuracy of clinical tests to rule out elbow fracture: a systematic review

  • Giorgio Breda;Gianluca De Marco;Pierfranco Cesaraccio;Paolo Pillastrini
    • Clinics in Shoulder and Elbow
    • /
    • 제26권2호
    • /
    • pp.182-190
    • /
    • 2023
  • Elbow traumas represent a relatively common condition in clinical practice. However, there is a lack of evidence regarding the most accurate tests for screening these potentially serious conditions and excluding elbow fractures. The purpose of this investigation was to analyze the literature concerning the diagnostic accuracy of clinical tests for the detection or exclusion of suspected elbow fractures. A systematic review was performed using the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines. Literature databases including PubMed, Cumulative Index to Nursing and Allied Health Literature, Diagnostic Test Accuracy, Cochrane Library, the Web of Science, and ScienceDirect were searched for diagnostic accuracy studies of subjects with suspected traumatic elbow fracture investigating clinical tests compared to imaging reference tests. The risk of bias in each study was assessed independently by two reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 checklist. Twelve studies (4,485 patients) were included. Three different types of index tests were extracted. In adults, these tests were very sensitive, with values up to 98.6% (95% confidence interval [CI], 95.0%-99.8%). The specificity was very variable, ranging from 24.0% (95% CI, 19.0%-30.0%) to 69.4% (95% CI, 57.3%-79.5%). The applicability of these tests was very high, while overall studies showed a medium risk of bias. Elbow full range of motion test, elbow extension test, and elbow extension and point tenderness test appear to be useful in the presence of a negative test to exclude fracture in a majority of cases. The specificity of all tests, however, does not allow us to draw useful conclusions because there was a great variability of results obtained.