• Title/Summary/Keyword: diagnostic point

Search Result 475, Processing Time 0.04 seconds

Ultrasound-guided Distance Measurements of Vertebral Structures for Lumbar Medial Branch Block (초음파 유도하에서의 요추부 후관절 내측지 차단술을 위한 주요 척추 구조물의 거리 측정)

  • Moon, Jin Cheon;Shim, Jae Kwang;Jo, Kwang Yun;Yoon, Kyung Bong;Kim, Won Oak;Yoon, Duck Mi
    • The Korean Journal of Pain
    • /
    • v.20 no.2
    • /
    • pp.111-115
    • /
    • 2007
  • Background: Selective diagnostic blocks of the medial branches of the dorsal primary ramus are usually performed under the guidance of fluoroscopic or computed tomography. Recently, however, ultrasound guidance has been suggested as an altemative method. In this study, the distances between the vertebral structures were measured and compared with the values measured using magnetic resonance imaging (MRI) to assess the clinical feasibility of using ultrasound-guided block in Korean patients. Methods: Five male and 15 female patients were enrolled in this study. The target point of the medial branch block in our study was the groove at the base of the superior articular process, We measured the depth from the skin to the target point at the transverse process (d-TP) and to the most superficial point of the superior articular process (d-AP). Results: The d-TP and d-AP values measured under ultrasound guidance were concordant with the values measured using MRI. Conclusions: The images of the bony landmarks obtained under ultrasound examination could be useful for ultrasound-guided lumbar medial branch block.

BioMEMS-EARLY DISEASE DETECTION (BioMEMS 기반의 조기 질병 진단 기술에 관한 연구)

  • Singh, Kanika;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2781-2784
    • /
    • 2007
  • Early detection of a disease is important to tackle treatment issues in a better manner. Several diagnostic techniques are in use, these days; for such purpose and tremendous research is going on to develop newer and newer methods. However, more work is required to be done to develop cheap and reliable early detection techniques. Micro-fluidic chips are also playing key role to deliver new devices for better health care. The present study focuses on a review of recent developments in the interrogation of different techniques and present state-of-the-art of microfluidic sensor for better, quick, easy, rapid, early, inexpensive and portable POCT (Point of Care testing device) device for a particular study, in this case, bone disease called osteoporosis. Some simulations of the microchip are also made to enable feasibility of the development of a blood-chip-based system. The proposed device will assist in early detection of diseases in an effective and successful manner.

  • PDF

Internet-Based Control and Monitoring System Using LonWorks Fieldbus for HVAC Application

  • Hong, Won-Pyo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1205-1210
    • /
    • 2004
  • The 4-20mA analog signal used in the various industrial fields to interface sensor in distributed process control has been replaced with relatively simple digital networks, called "fieldbus, and recently by Ethernet. Significant advances in Internet and computer technology have made it possible to develop an Internet based control, monitoring, and operation scheduling system for heating, ventilation and air-conditioning (HVAC) systems. The seamless integration of data networks with control networks allows access to any control point from anywhere. Field compatible field devices become so-called "smart" devices, capable of executing simple control, diagnostic and maintenance functions and providing bidirectional serial communication to higher level controller. The most important HVAC of BAS has received nationwide attention because of higher portion of more than 40% in building sector energy use and limited resources. This paper presents the Internet-based monitoring and control architecture and development of LonWorks control modules for AHU (air handling units) of HVAC in viewpoint of configuring BAS network. This article addresses issues in architecture section, electronics, embedded processors and software, and internet technologies.

  • PDF

Diagnostic Study of Problems under Asymptotically Generalized Least Squares Estimation of Physical Health Model

  • Kim, Jung-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.5
    • /
    • pp.1030-1041
    • /
    • 1999
  • This study examined those problems noticed under the Asymptotically Generalized Least Squares estimator in evaluating a structural model of physical health. The problems were highly correlated parameter estimates and high standard errors of some parameter estimates. Separate analyses of the endogenous part of the model and of the metric of a latent factor revealed a highly skewed and kurtotic measurement indicator as the focal point of the manifested problems. Since the sample sizes are far below that needed to produce adequate AGLS estimates in the given modeling conditions, the adequacy of the Maximum Likelihood estimator is further examined with the robust statistics and the bootstrap method. These methods demonstrated that the ML methods were unbiased and statistical decisions based upon the ML standard errors remained almost the same. Suggestions are made for future studies adopting structural equation modeling technique in terms of selecting of a reference indicator and adopting those statistics corrected for nonormality.

  • PDF

Analysis of Surface flashover Depending on Gap Distance in Epoxy Region (에폭시 연면거리에 따른 파괴전압 분석)

  • Yoon, Jae-Hun;Lee, Sueng-Su;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.400-400
    • /
    • 2009
  • In a wide variety of high-voltage applications surface flashover plays major role in the system's performance and yet has not been studied in great detail for atmospheric conditions with modem diagnostic tools. surface flashover for both direct current and pulsed voltages in considered. within the setup, parameters such as geometry, material characteristics of the applied voltage can be altered. This paper review surface flashover of insulator, primarily in atmosphere. It discusses theories and models relating to surface flashover and experimental results. surface flashover of insulators in atmosphere generally is initiated by the emission of electrons from the cathode triple junction point (the region where the electrode, insulator, air). the electrode material was copper, and a AC voltage was applied between the electrodes. these results were compared with the surface flashover characteristic of epoxy.

  • PDF

Atrial Myxoma; Report of 4 Cases (심방 점액종 -4례 보고-)

  • An, Hyuk
    • Journal of Chest Surgery
    • /
    • v.12 no.1
    • /
    • pp.23-29
    • /
    • 1979
  • Hyuk An, M.D.Atrial myxoma constitutes the most significant of all cardiac neoplasm. About 75% occur in the left atrium and 25% in the right. They may cause severe and progressive disease mimicking valvular heart disease. But recently attention to differential point in the clinical features along with various diagnostic techniques have allowed pre-operative diagnosis in the most cases. From April, `77 to Aug., `78, three cases of left atrial myxoma and one case of right atrial myxoma were operated in Seoul National University Hospital. Pre-operative diagnosis was established with echocardiography and cardiac angiography. In all cases, tumors were resected with cardiopulmonary bypass successfully, and discharged with good results.

  • PDF

Redesigning Taguchi Sensor

  • Hossein-Babaei Faramarz;Park, Won-Kyu
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.1
    • /
    • pp.11-15
    • /
    • 2005
  • The configuration of the main components and the physical structure of the Taguchi sensor, the first ceramic gas sensor mass produced, has remained virtually unaltered since its appearance 40 years ago. This device owns an excellent combination of the quality factors but is non-selective. The research efforts carried out to enhance the selectivity in this resistive gas sensor are briefly reviewed. A novel design, Capillary-attached Gas Sensor (CGS), is introduced, which employs the same ceramic components used for the fabrication of a classical Taguchi sensor but in altered geometries. CGS presents remarkable advantages from the view point of selectivity over the original design. While the steady state response of a CGS has the same significance as that of the Taguchi sensor, its transient response presents valuable diagnostic information. Fabrication and test of a prototype CGS is reported.

Efficient Implementing of DNA Computing-inspired Pattern Classifier Using GPU (GPU를 이용한 DNA 컴퓨팅 기반 패턴 분류기의 효율적 구현)

  • Choi, Sun-Wook;Lee, Chong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1424-1434
    • /
    • 2009
  • DNA computing-inspired pattern classification based on the hypernetwork model is a novel approach to pattern classification problems. The hypernetwork model has been shown to be a powerful tool for multi-class data analysis. However, the ordinary hypernetwork model has limitations, such as operating sequentially only. In this paper, we propose a efficient implementing method of DNA computing-inspired pattern classifier using GPU. We show simulation results of multi-class pattern classification from hand-written digit data, DNA microarray data and 8 category scene data for performance evaluation. and we also compare of operation time of the proposed DNA computing-inspired pattern classifier on each operating environments such as CPU and GPU. Experiment results show competitive diagnosis results over other conventional machine learning algorithms. We could confirm the proposed DNA computing-inspired pattern classifier, designed on GPU using CUDA platform, which is suitable for multi-class data classification. And its operating speed is fast enough to comply point-of-care diagnostic purpose and real-time scene categorization and hand-written digit data classification.

Analysis of Surface Flashover Depending on Insulator Gap Distance in Vacuum (진공에서 절연체의 연면거리에 따른 파괴전압 분석)

  • Yoon, Jae-Hun;Lim, Jong-Nam;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1471_1472
    • /
    • 2009
  • In a wide variety of high-voltage applications surface flashover plays major role in the system's performance and yet has not been studied in great detail for vacuum conditions with modern diagnostic tools. surface flashover for both direct current and pulsed voltages in considered. within the setup, parameters such as geometry, material characteristics of the applied voltage can be altered. This paper review surface flashover of insulator, primarily in vacuum. It discusses theories and models relating to surface flashover and experimental results. surface flashover of insulators in vacuum generally is initiated by the emission of electrons from the cathode triple junction point (the region where the electrode, insulator, vacuum). the electrode material was copper, and a AC voltage was applied between the electrodes. these results were compared with the surface flashover characteristic of insulator at results, surface flashover influenced only insulator surface condition. and increasing vacuum pressure was risen breakdown voltage.

  • PDF

Traumatic Aneurysm of the Pericallosal artery - A Case Report - (뇌량주위동맥에 발생한 외상성 뇌동맥류 - 증례보고 -)

  • Seo, Eui Kyo;Joo, Jin Yang
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.12
    • /
    • pp.1427-1429
    • /
    • 2001
  • Traumatic intracranial aneurysms are rare, compromising less than 1% of intracranial aneurysms. The case of 20-year-old man suffered from delayed frontal intracerebral hematoma, subarachnoid hemorrhage and intraventricular hemorrhage from traumatic pericallosal aneurysm 12 days after head injury is presented. Traumatic pericallosal artery aneurysm is always near the falcine edge, is unrelated to arterial branching point. Sudden movement of brain and artery causes vessel wall injury against the stationary edge of the falx. Because of high mortality rate of ruptured traumatic aneurysm, clinical suspicion must be focused on the prompt diagnostic work-up and early treatment.

  • PDF