• Title/Summary/Keyword: diagnostic point

Search Result 475, Processing Time 0.042 seconds

Pericarditis Arisen from Liver Abscess: Report of 2 Cases (간농양에 병발한 심낭염 치험 2례)

  • 서충헌
    • Journal of Chest Surgery
    • /
    • v.14 no.2
    • /
    • pp.140-143
    • /
    • 1981
  • Thymolipoma is extremely uncommon benign mediastinal tumor consisting of fatty and thymic tissue. Only 50 verified cases have been reported in the world literatures. This one case is the first reported example of surgically treated thymolipoma associated with spontaneous pneumothorax. A thirty-two year old male patient had been in good health until two days prior to admission, when he noted sudden dyspnea associated with an aching pain over the left precordium. The dyspnea and chest pain had become progressively worse. The physical examination revealed that left hemithorax was tympanic sound on percussion and absence of breathing sound on auscultation and point of maximal impulse was located on the 4th intercostal space at the left sternal border. Emergency closed thoracostomy was performed under the impression of tension type spontaneous pneumothorax of the left lung. After closed thoracostomy, point of maximal impulse was not changed inspire of full expansion of the left lung and chest X-ray was strongly suggested pericardial effusion or cardiomegaly which couldn`t account for by clinical course and hemodynamic evidence. EKG, echocardiogram, bronchofiberoscophy, bronchogram and diagnostic thoracentesis was performed. On Dec. 8, 1980, operation was performed under the impression of mediastinal tumor in the anterior mediastinum. At left posterolateral thoractomy, a large fatty mass, measuring 35 x 27 x 13 Cm in dimension and weighing 3350 gm, was resected and multiple bullae on the apicoposterior segment of the left upper lobe was resected and continuously sutured. The pathologic diagnosis of the fatty mass was thymolipoma. The postoperative course was uneventful and discharged in good general conditions.

  • PDF

Thymolipoma associated with spontaneous pneumothorax: report of a case (자연기흉을 합병한 흉선지방종의 치험례)

  • 이철범
    • Journal of Chest Surgery
    • /
    • v.14 no.2
    • /
    • pp.135-139
    • /
    • 1981
  • Thymolipoma is extremely uncommon benign mediastinal tumor consisting of fatty and thymic tissue. Only 50 verified cases have been reported in the world literatures. This one case is the first reported example of surgically treated thymolipoma associated with spontaneous pneumothorax. A thirty-two year old male patient had been in good health until two days prior to admission, when he noted sudden dyspnea associated with an aching pain over the left precordium. The dyspnea and chest pain had become progressively worse. The physical examination revealed that left hemithorax was tympanic sound on percussion and absence of breathing sound on auscultation and point of maximal impulse was located on the 4th intercostal space at the left sternal border. Emergency closed thoracostomy was performed under the impression of tension type spontaneous pneumothorax of the left lung. After closed thoracostomy, point of maximal impulse was not changed inspire of full expansion of the left lung and chest X-ray was strongly suggested pericardial effusion or cardiomegaly which couldn`t account for by clinical course and hemodynamic evidence. EKG, echocardiogram, bronchofiberoscophy, bronchogram and diagnostic thoracentesis was performed. On Dec. 8, 1980, operation was performed under the impression of mediastinal tumor in the anterior mediastinum. At left posterolateral thoractomy, a large fatty mass, measuring 35 x 27 x 13 Cm in dimension and weighing 3350 gm, was resected and multiple bullae on the apicoposterior segment of the left upper lobe was resected and continuously sutured. The pathologic diagnosis of the fatty mass was thymolipoma. The postoperative course was uneventful and discharged in good general conditions.

  • PDF

A Study on Fault Detection of Off-design Performance for Smart UAV Propulsion System (스마트 무인기용 가스터빈 엔진의 탈설계 영역 구성품 손상 진단에 관한 연구)

  • Kong, Chang-Duk;Kho, Seong-Hee;Choi, In-Soo;Lee, Seung-Heon;Lee, Chang-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.245-249
    • /
    • 2007
  • In this study a model-based diagnostic method using the Neural Network was proposed for PW206C turbo shaft engine and performance model was developed by SIMULINK. Fault and test database to build the NN was obtained at various off-design operating range such as flight altitude, flight Mach number and gas generator rotational speed variation. According to the fault detection analysis results, it was confirmed that the proposed fault detection method could find well the fault of compressor, compressor turbine and power turbine at on-design point as well as off-design point conditions.

  • PDF

A Study on fault Detection of Off-design Performance for Smart UAV Propulsion System (스마트 무인기용 가스터빈 엔진의 탈설계 영역 구성품 손상 진단에 관한 연구)

  • Kong, Chang-Duk;Kho, Seong-Hee;Ki, Ja-Young;Lee, Chang-Ho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.3
    • /
    • pp.29-34
    • /
    • 2007
  • In this study a model-based diagnostic method using the Neural Network was proposed for PW206C turbo shaft engine and performance model was developed by SIMULINK. Fault and test database to build the NN was obtained at various off-design operating range such as flight altitude, flight Mach number and gas generator rotational speed variation. According to the fault detection analysis results, it was confirmed that the proposed fault detection method could find well the fault of compressor, compressor turbine and power turbine at on-design point as well as off-design point conditions.

High-accuracy quantitative principle of a new compact digital PCR equipment: Lab On An Array

  • Lee, Haeun;Lee, Cherl-Joon;Kim, Dong Hee;Cho, Chun-Sung;Shin, Wonseok;Han, Kyudong
    • Genomics & Informatics
    • /
    • v.19 no.3
    • /
    • pp.34.1-34.6
    • /
    • 2021
  • Digital PCR (dPCR) is the third-generation PCR that enables real-time absolute quantification without reference materials. Recently, global diagnosis companies have developed new dPCR equipment. In line with the development, the Lab On An Array (LOAA) dPCR analyzer (Optolane) was launched last year. The LOAA dPCR is a semiconductor chip-based separation PCR type equipment. The LOAA dPCR includes Micro Electro Mechanical System that can be injected by partitioning the target gene into 56 to 20,000 wells. The amount of target gene per wells is digitized to 0 or 1 as the number of well gradually increases to 20,000 wells because its principle follows Poisson distribution, which allows the LOAA dPCR to perform precise absolute quantification. LOAA determined region of interest first prior to dPCR operation. To exclude invalid wells for the quantification, the LOAA dPCR has applied various filtering methods using brightness, slope, baseline, and noise filters. As the coronavirus disease 2019 has now spread around the world, needs for diagnostic equipment of point of care testing (POCT) are increasing. The LOAA dPCR is expected to be suitable for POCT diagnosis due to its compact size and high accuracy. Here, we describe the quantitative principle of the LOAA dPCR and suggest that it can be applied to various fields.

Study of threshold and opacity in three-dimensional CT volume rendering of oral and maxillofacial area (구강악안면영역의 3차원 CT 영상 재형성시 역치 및 불투명도에 대한 연구)

  • Choi, Mun-Kyung;Lee, Sam-Sun;Huh, Kyung-Hoe;Yi, Won-Jin;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • Purpose: This study was designed to determine a proper threshold value and opacity in three-dimensional CT volume rendering of oral and maxillofacial area. Materials and Methods: Three-dimensional CT data obtained from 50 persons who were done orthognatic surgery in department of oral and maxillofacial radiology of Seoul National University retrospectively. 12 volume rendering post-processing protocols of combination of threshold(100HU, 150HU, 221HU, 270HU) and opacity (58%, 80%, 90%) were applied. Five observers independently evaluated image quality using a five-point range scale. The results were analyzed by receiver operating characteristic curves, ANOVA and Kappa value. And three oromaxillofacial surgeons chose the all images that they thought proper clinically in the all of images. Results: Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. The highest diagnostic accuracy appear with 100HU and 58% opacity. and the lowest diagnostic accuracy appear with 221HU and 58% opacity that are being used protocol in department of oral and maxillofacial radiology of Seoul National University. But, no statistically significant difference was noted between any of the protocols. And the number of proper images clinically that chosen by three oromaxillofacial surgeons is the largest in the cases of protocol 8 (221HU, opacity 80%) and protocol 11 (270HU, opacity 80%) in one after the other. Conclusion: Threshold and opacity in volume rendering can be controled easily and these can be causes of making an diagnostic accuracy. So we need to select proper values of these factors.

  • PDF

The Comparison of Knee Joint Displaying between The Anteroposterior Weight Bearing View and the Metatarsophalangeal View with Osteoarthritis Patients (골관절염 환자의 촬영방법에 대한 고찰 : AP-WB(Weight-bearing AP), MTP(semiflexed) 촬영법의 비교 고찰을 중심으로)

  • Jeon, Ju-Seob;Park, Hwan-Sang;Moon, Il-Bong;Moon, Ju-Wan;Choi, Nam-Kil;Kim, Chang-Bok;Eun, Sung-Jong
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • Objective : The aim of this study was to compare the knee joint displaying between the anteroposterior weight bearing(AP-WB) View and the metatarsophalangeal(MTP) view for assessing joint space narrowing(JSN) and osteophytes in osteoarthritis patients. Subjects and Materials : Two hundreds of twenty patients(38 men) who came rheumatoid caused by knee pain, had both AP-WB and MTP views taken on a day. Radiographs were evaluated independently by 13 experienced observers(3 orthopedics surgeon, 2 rheumatogist, 3 radiologist, 5 radiological technologist) They assessed JSN and osteophytes using by PACS monitor JSN was scored by the optic evaluation to the nearest at the narrowest point in medial compartments of the tibiofemoral joint in both knees. Osteophytes were graded 0 to 3(bad 0, not bad 1, good 2 and very good 3) according to a standard atlas. All exam was using by Philips(Buckey Diagnostic-TH) X-ray material. Exposure condition was 60 kv, 8 mAs and 100 cm focus to film distance. Results : JSN was scored $1.32{\pm}0.050$ in AP-WB view, $2.51{\pm}0.046$ in MTP view. MTP view of JSN score is higher to AP-WB view significantly(p<0.05). Osteophytes scored $2.14{\pm}0.054$ in AP-WB view, $2.10{\pm}0.054$ in MTP view. There was no difference(p<0.05) between MTP view and AP-WB view in osteophytes. But MTP view was more reproducible than AP-WB view Conclusions : Joint space narrowing is most important factor to diagnosis with knee joint Osteoarthritis patients. This study was summarized as follows; In comparision of JSN, MTP view was more widely displayed than AP-WB view. In comparision of Osteophytes, there was no difference between MTP view and AP-WB view. It was concluded MTP view was more useful method to diagnosis of knee joint Osteoarthritis patients.

  • PDF

A Study on the Introduction of Performance Certification System of Inspection and Diagnostic Equipment for Infrastructure (시설물 진단장비의 성능인증제 도입에 관한 연구)

  • Hong, Sung-Ho;Kim, Jung-Gon;Cho, Jae-Young;Kim, Do-Hyoung;Kim, Jung-Yeol;Kim, Young-Min
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.104-115
    • /
    • 2022
  • Purpose: Infrastructure inspection and its diagnostics technique have been rapidly developing recently. Therefore, it is important to secure the reliability of diagnostic equipment, and this paper deals with inspection of diagnostic equipment, introduction to a certification system and development plans for infrastructure. Method: Several certification systems are established and introduction plans are reviewed through experts by synthesizing the contents of certification research for existing infrastructure diagnosis equipment. In addition, the revision of the law for introduction of the system is reviewed, detailed operation regulations are prepared and phased development plans are reviewed, which are based on the operation scenario. Result: Inspection and certification plans were constructed through four routes in order to consider infrastructure inspection and diagnostic equipment in use, and new diagnostic equipment using state-of-the-art technology. Furthermore, market confusion depending on the introduction of a new certification system is minimized and reliability is secured by transforming a simple inspection system in the short term into a formal certification system in the long term. The law amendments according to the introduction of the system were reviewed and detailed operation regulations were developed. Also, phased development plans, which are based on the long-term development scenario including manpower, infrastructure and specifications, were presented. Conclusion: It is important to secure reliability through the distribution and certification of diagnostic equipment using 4th industrial technology to strengthen the safety management of infrastructure at the national level since the infrastructure is various in type and increasingly large in size. It is also essential to train human resources who can use new technology with inspection and diagnosis system in order to enhance the safety management of all infrastructures. Moreover, it is necessary to introduce a regular inspection system for infrastructure that combines loT technology in the long-term point of view and to promote the introduction by giving active incentives to institutions that actively accept it.

Clinical report on the improvement of the symptoms of pneumonia by the aqueous extract of Platycodon grandiflorum (24년생 장생도라지 약침액(藥鍼液)의 폐렴 증상 개선효과에 대한 임상례)

  • Kim, Sook-Kyeng;Choi, Sung-Gwun;Lim, Hyi-Jeong;Moon, Ik-Ryoul;Park, Hyeong-Seon;Oh, Su-Jin
    • Journal of Pharmacopuncture
    • /
    • v.4 no.3
    • /
    • pp.59-67
    • /
    • 2001
  • Objective: The purpose of this report is to prove the clinical effect of Platycodon grandiflorum aqueous extract on pneumoniae patients. Methods: We used the aqueous extract of Platycodon grandiflorum to treat two pneumoniae patients. It was injected into five acupuncture points, which was Chondol(天突:CV22) 1 point, Pyesu(肺兪 : BL13) 2 point, and Kworumsu(厥陰兪: BL14) 2 point. Results & conclusions: We have used the aqueous extract of 24-year-old JK for treating the patients suffering from lung diseases, and have experienced the actual effects. Of the treated, two pneumonia-involved patients showed apparent improvement in simple chest X-ray and clinical symptoms. The patients were treated with JK (Jang-saeng platycodon) aqueous extract 25 and 22 times individually. The results were as follows. 1. The symptoms including coughing, phlegm, and fever were improved in two cases. 2. The lung infiltration in simple chest X-ray decreased and the WBC count was kept within normal range in two cases. 3. Side effect such as itching was not found in the process of JK aqueous extract treatment. 4. The criteria for pneumonia are fever, coughing with purulent phlegm, pleural chest pain, the evidence of new infiltration in simple chest X-ray, sign of lung sclerosis in auscultation, increase of WBC count, etc. But they may not be the proper objective diagnostic standards. So we had trouble in statistic process and numerical interpretation. Putting these results together, the JK aqueous extract is considered to be effective in treating patients for pneumonia, and the continuous research and accumulation of data is needed.

Effects Analysis of Stimulating Lung Ear Reflex Point by Facial Appearance Analysis of Bio-signals (생체신호의 얼굴 발현 분석을 통한 폐 이혈 반사점 자극의 효과 분석)

  • Kim, Bong-Hyun;Cho, Dong-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2812-2818
    • /
    • 2013
  • Medicine such as Korean oriental medicine and alternative medicine is inferior to western medicine in diagnostic skills and treatment regimen but despite going through a lot of in western medicine preference to that is situations. Likewise, in Korean oriental medicine and alternative medicine have been closely linked to that effect not proven scientifically to be solved is regarded as the biggest drawback. In this paper, auricular therapy that is often used in alternative medicine to help strengthen the internal organs function which whether the conduct of stimulating ear is effective or not by applying to ocular inspection of Korean oriental medicine is proposed. For this purpose, lung ear reflex points to stimulate were performed after the right cheek color by measuring stimulation before comparison and analysis of the experiments. In addition, in order to examine this first analysis of the human body to the lungs and the elements of image analysis is to study. Experimental result, derived b value increased to a value of the right cheek and the results by lung ear to stimulate reflex point.