• Title/Summary/Keyword: diagnostic point

Search Result 479, Processing Time 0.028 seconds

Development of Automated Rapid Influenza Diagnostic Test Method Based on Image Recognition (영상 인식 기반 신속 인플루엔자 자동 판독 기법 개발)

  • Lee, Ji Eun;Joo, Yoon Ha;Lee, Jung Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.3
    • /
    • pp.97-104
    • /
    • 2019
  • To examine different types of influenza diagnostic test kits automatically, automated rapid influenza diagnostic test method based on image recognition is proposed in this paper. First, the proposed methods classify a variety of the rapid influenza diagnostic test kit based on support vector machine that analyzes the kits' feature point. Then, to improve the accuracy of test, the proposed methods match the histogram of both the target image of influenza kit and the input image of influenza kit for minimizing the effect of environment factors, such as lighting and exposure variations. And, to minimize the effect from composition of the hand-helds devices, the proposed methods extract the feature point and match point-by-point between target image of influenza kit and input image of influenza kit. Experimental results of 124 experimental group show that the proposed methods significantly have effectiveness, which shows 90% accuracy in moderate antigen, for the preliminary examination of influenza, and provides the opportunity for taking action against influenza.

Diagnostic value of eosinopenia and neutrophil to lymphocyte ratio on early onset neonatal sepsis

  • Wilar, Rocky
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.6
    • /
    • pp.217-223
    • /
    • 2019
  • Purpose: To determine the diagnostic value of eosinopenia and the neutrophil-to-lymphocyte ratio (NLR) in the diagnosis of early onset neonatal sepsis (EONS). Methods: This cross-sectional study was conducted in the Neonatology Ward of R.D. Kandou General Hospital Manado between July and October 2017. Samples were obtained from all neonates meeting the inclusion criteria for EONS. Data were encoded using logistic regression analysis, the point-biserial correlation coefficient, chi-square test, and receiver operating characteristic curve analysis, with a P value <0.05 considered significant. Results: Of 120 neonates who met the inclusion criteria, 73 (60.8%) were males and 47 (39.2%) were females. Ninety (75%) were included in the sepsis group and 30 (25%) in the nonsepsis group. The mean eosinophil count in EONS and non-EONS groups was $169.8{\pm}197.1cells/mm^3$ and $405.7{\pm}288.9cells/mm^3$, respectively, with statistically significant difference (P<0.001). The diagnostic value of eosinopenia in the EONS group (cutoff point: $140cells/mm^3$) showed 60.0% sensitivity and 90.0% specificity. The mean NLR in EONS and non-EONS groups was $2.82{\pm}2.29$ and $0.82{\pm}0.32$, respectively, with statistically significant difference (P<0.001). The diagnostic value of NLR in the EONS group (cutoff point, 1.24) showed 83.3% sensitivity and 93.3% specificity. Conclusion: Eosinopenia has high specificity as a diagnostic marker for EONS and an increased NLR has high sensitivity and specificity as a diagnostic marker for EONS.

The Use of Confidence Interval of Measures of Diagnostic Accuracy (진단검사 정확도 평가지표의 신뢰구간)

  • Oh, Tae-Ho;Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.319-323
    • /
    • 2015
  • The performance of diagnostic test accuracy is usually summarized by a variety of statistics such as sensitivity, specificity, predictive value, likelihood ratio, and kappa. These indices are most commonly presented when evaluations of competing diagnostic tests are reported, and it is of utmost importance to compare the accuracies of diagnostic tests to decide on the best available test for certain medical disorder. However, it is important to emphasize that specific point values of these indices are merely estimates. If parameter estimates are reported without a measure of uncertainty (precision), knowledgeable readers cannot know the range within which the true values of the indices are likely to lie. Therefore, when evaluations of diagnostic accuracy are reported the precision of estimates should be stated in parallel. To reflect the precision of any estimate of a diagnostic performance characteristic or of the difference between performance characteristics, the computation of confidential interval (CI), an indicator of precision, is widely used in medical literatures in that CIs are more informative to interpret test results than the simple point estimates. The majority of peer-reviewed journals usually require CIs to be specified for descriptive estimates, whereas domestic veterinary journals seem less vigilant on this issues. This paper describes how to calculate the indices and associated CIs using practical examples when assessing diagnostic test performance.

Implementation of point-of-care platforms for rapid detection of porcine circovirus type 2

  • Chiao-Hsu Ke;Mao-Yuan Du;Wang-Ju Hsieh;Chiu-Chiao Lin;James Mingjuh Ting;Ming-Tang Chiou;Chao-Nan Lin
    • Journal of Veterinary Science
    • /
    • v.25 no.2
    • /
    • pp.28.1-28.11
    • /
    • 2024
  • Background: Porcine circovirus type 2 (PCV2) infection is ubiquitous around the world. Diagnosis of the porcine circovirus-associated disease requires clinic-pathological elements together with the quantification of viral loads. Furthermore, given pig farms in regions lacking access to sufficient laboratory equipment, developing diagnostic devices with high accuracy, accessibility, and affordability is a necessity. Objectives: This study aims to investigate two newly developed diagnostic tools that may satisfy these criteria. Methods: We collected 250 specimens, including 170 PCV2-positive and 80 PCV2-negative samples. The standard diagnosis and cycle threshold (Ct) values were determined by quantitative polymerase chain reaction (qPCR). Then, two point-of-care (POC) diagnostic platforms, convective polymerase chain reaction (cPCR, qualitative assay: positive or negative results are shown) and EZtargex (quantitative assay: Ct values are shown), were examined and analyzed. Results: The sensitivity and specificity of cPCR were 88.23% and 100%, respectively; the sensitivity and specificity of EZtargex were 87.65% and 100%, respectively. These assays also showed excellent concordance compared with the qPCR assay (κ = 0.828 for cPCR and κ = 0.820 for EZtargex). The statistical analysis showed a great diagnostic power of the EZtargex assay to discriminate between samples with different levels of positivity. Conclusions: The two point-of-care diagnostic platforms are accurate, rapid, convenient and require little training for PCV2 diagnosis. These POC platforms can discriminate viral loads to predict the clinical status of the animals. The current study provided evidence that these diagnostics were applicable with high sensitivity and specificity in the diagnosis of PCV2 infection in the field.

Diagnostic Potential of Strain Ratio Measurement and a 5 Point Scoring Method for Detection of Breast Cancer: Chinese Experience

  • Parajuly, Shyam Sundar;Lan, Peng Yu;Yun, Ma Bu;Gang, Yang Zhi;Hua, Zhuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1447-1452
    • /
    • 2012
  • Aim: To evaluate the differential diagnostic potential of lesion stiffness assessed by the sonoelastographic strain index ratio (SR) and elastographic color scoring system (UE) for breast lesions. Materials and Methods: Three hundred and forty two breast masses (158 benign and 184 malignant) from 325 consecutive patients (mean age 44.2 years; range 16-81)who had been scheduled for a sonographically guided core biopsy were examined proposed by Itoh et al, with scoring 1-3=benign and 4-5=malignant. Strain and area ratios of each lesion were calculated within the same machine. Histological diagnosis was used as the reference standard. The area under the curve (AUC) and cut-off point were obtained by receiver operating curve and the cross table Fischer Test was carried out for assessing diagnostic value. Sensitivity, specificity, PPV, NPV, accuracy and false-discovery rates were compared. Results: The mean strain ratios for benign and malignant lesions were 1.87 and 7.9 respectively. (P<0.0001). When a cutoff point of 3.54 was used, SR had a sensitivity of 94.6%, a specificity 94.3%, a PPV of 95.1%, an NPV of 93.7% and an accuracy of 94.4%. The AUC values were 0.90 for the 5 point scoring system (UE) and 0.96 for the strain index ratio. The overall diagnostic performance was SR method was better (P<0.05). Conclusions: Strain ratio measurement could be another effective predictor in elastography imaging besides 5 the point scoring system for differential diagnosis of breast lesions.

Image enhancement of digital periapical radiographs according to diagnostic tasks

  • Choi, Jin-Woo;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.31-35
    • /
    • 2014
  • Purpose: This study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Materials and Methods: Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. Results: There were significant differences between the image quality of the processed images and that of the original images (P< 0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P< 0.01). Conclusion: Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

Robust Damage Diagnostic Method Using Short Time Fourier Transform and Beating (단시간 푸리에 변환과 맥놀이를 이용한 강건한 결함 진단법)

  • Lee, Ho-Cheol
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1108-1117
    • /
    • 2005
  • A robust damage detection method using short-time Fourier transform and beating phenomena is presented as an estimating tool of the healthiness of large structures. The present technique makes use of beating phenomena that manifest themselves when two signals of similar frequencies are added or subtracted. Unlike most existing methods based on vibration signals, the present approach does not require an analytic model for target structures. Furthermore, the main advantage of the proposed method compared to the competing diagnostic method using vibration data is its robustness. The proposed method is not affected by the amplitude of exciting signals and the location of exciting points. From a measuring view point. the location of sensing point have no influence on the performance of the present method. With a view to verifying the effectiveness of this method. a series of experiments are made and the results show its possibility as a robust damage diagnostic method.

A Diagnostic Technique for Distribution Transformers using Top Oil Temperature (최상부 유온을 이용한 배전용 변압기의 진단 기법)

  • Choe, Do-Hyeok;Yun, Yong-Han;Min, Gyeong-Rae;Kim, Jae-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.5
    • /
    • pp.242-251
    • /
    • 2000
  • In this paper, we argued the possibility of the diagnostic technique for distribution transformers using the top oil temperature rising above the ambient temperature. The proposed diagnostic technique used the reference top oil temperature rising at rated current. We determined the emergency value of the transformer using the limitation of the top oil temperature rising and calculated the loss of life. The top oil temperature rises because of the load currents. In this point, the proposed diagnostic technique was explained. The proposed system measures the load current, top oil temperature and ambient temperature. With the diagnostic device, we tested the top oil temperature rising of t재 transformers. Then the loss of life was calculated by the top oil temperature.

  • PDF

Design of Arrhythmia Automatic Diagnostic System Using Decision Table (판정테이블을 이용한 부정맥 자동진단 시스템 설계에 관한 연구)

  • 정기삼;이재준
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.63-70
    • /
    • 1991
  • Design of Arrhythmia Automatic Diagnostic System Using Decision Table We have developed an arrhythmia automatic diagnostic system using decision table which is based on the criteria of Minnesota code. This system is divided into two Parts. One is wave detection algorithm using significant point extraction method, the other is arrhythmia diag- nostic algorthm. The proposed system allows physicians to diagnose more accurately by pro- viding the objective information about a lot of computer -processed ECG data.

  • PDF

Radiofrequency Facet Joint Denervation in the Treatment of Low Back Pain: Relationship with the Diagnostic Block (요부 후지낵측지 고주파 열응고술: 진단적 차단과의 연관성)

  • Shim, Jae-Chol;Seung, Ik-Sang
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.218-224
    • /
    • 2001
  • Background: Response to diagnostic blocks does not consistently predict the outcome of interventional facet denervation. We investigated the relationship between pain relief by the percutaneous radiofrequency denervation of the lumbar zygapophysial joints with the result of facet joint diagnostic local anesthetic injection in patients with back pain originating from the lumbar zygapophysial joint. Methods: There were 35 patients enrolled, with ranging in age from 25 to 76 years ($52.6{\pm}12.7$ years, mean ${\pm}$ SD). We studied 7 men (20%) and 28 women (80%). All patients underwent double diagnostic block of $L_{3/4}$, $L_{4/5}$ and $L_5-S_1$ facet joint with 0.5% bupivacaine. The 35 patients fell into the following group. (1) Group A (n = 16): those who felt clear relief (pain free with Likert scale) from the double diagnostic block (2) Group B (n = 19): 11 patients who were always equivocal in their response to the double diagnostic block and 8 patients who were either pain free or equivocal in their response to the double diagnostic block. All 11 patients were done the facet joint denervation. The effect on the pain was evaluated with 4 point Likert scale 1, 6 and 12 weeks after the procedure. We evaluated the relationship between the pain response to diagnostic block and the pain relief with facet joint denervation. Results: Significant correlation was observed between the response to diagnostic block and pain relief with facet denervation (P < 0.05). We found no correlation between the categories of spinal operation and pain response to facet denervation (P value > 0.05). Conclusions: A satisfactory result of lumbar facet joint denervation can be obtained in many patients, especillay in patients whose pain were relieved by the diagnostic double facet joint block. It may be said that facet joint denervation for mechanical low back pain using radiofrequency thermocoagulation is a safe, easy, and repeatable technique.

  • PDF