• 제목/요약/키워드: diagnostic parameters

Search Result 565, Processing Time 0.036 seconds

Effect of the Sensor Location on Magnetocardiography (심자도 센서의 위치 효과에 대한 연구)

  • Lim, Hyun-Kyoon;Kim, Ki-Woong;Kwon, Hyuk-Chan;Lee, Yong-Ho
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Magnetocardiography (MCG) is a non-contact, non-invasive, and harmless diagnostic tool to detect the abnormal electrical conductivities of the heart caused by the various coronary artery disease or cardiac muscular disease. The purpose of this study is to identify whether MCG signals and MCG parameter values vary depending on the location of sensor assembly. It will be an important reference for the standard measurement. Four healthy male subjects (33.3$\pm$6.3 years) participated in this study. Basal recording was made at 20 mm apart from the chest surface. All subjects were requested to take a regular breathe while MCG was taken. The gap between the chest surface and the bottom of the sensor assembly was 20, 40, 60, and 80 mm. Recording was made using 64 channel MCG system (Axial type, first order gradiometer) developed by Korea Research Institute of Standards and Science (KRISS). After resting for two minutes in a supine position on the bed in magnetically shielded room, MCG were recorded for 30 s. As the sensor location is getting away from the chest surface signal, the amplitude of R and T wave peak decreases to 70% (at 40 mm gap), 50% (at 60 mm), and 37% (at 80 mm) of the reference strength measured (y = $1.3903e^{-0.0169x}$, $R^2$ = 0.99; where y=amplitude remained after reduction, x=distance between chest surface and sensor location). The regression equations may be used as a good reference to calculate how much strength will be decreased by the distance. In MCG parameters, most values of parameters were decreased as the gap was increased. As an example, the current moment at T-wave peak reduced to 52% (at 40 mm gap), 33% (at 60 mm), and 19% (at 80 mm). However, the difference caused by the gap could be reduced by considering the distance when the MCG parameters were calculated. The study results can be used as a useful reference to design the baseline and the sensor location.

  • PDF

Diagnosis of Pulmonary Arterial Hypertension in Children by Using Cardiac Computed Tomography

  • Shyh-Jye Chen;Jou-Hsuan Huang;Wen-Jeng Lee;Ming-Tai Lin;Yih-Sharng Chen;Jou-Kou Wang
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.976-984
    • /
    • 2019
  • Objective: To establish diagnostic criteria for pulmonary arterial hypertension (PAH) in children by using parameters obtained through noninvasive cardiac computed tomography (CCT). Materials and Methods: We retrospectively measured parameters from CCT images of children from a single institution in a multiple stepwise process. A total of 208 children with mean age of 10.5 years (range: 4 days-18.9 years) were assessed. The variables were classified into three groups: the great arteries; the ventricular walls; and the bilateral ventricular cavities. The relationship between the parameters obtained from the CCT images and mean pulmonary arterial pressure (mPAP) was tested and adjusted by the children's body size. Reference curves for the pulmonary trunk diameter (PTD) and ratio of diameter of pulmonary trunk to ascending aorta (rPTAo) of children with CCT images of normal hearts, adjusted for height, were plotted. Threshold lines were established on the reference curves. Results: PTD and rPTAo on the CCT images were significantly positively correlated with mPAP (r > 0.85, p < 0.01). Height was the body size parameter most correlated with PTD (r = 0.91, p < 0.01) and rPTAo (r = -0.69, p < 0.01). On the basis of the threshold lines on the reference curves, PTD and rPTAo both showed 88.9% sensitivity for PAH diagnosis, with negative predictive values of 93.3% and 92.9%, respectively. Conclusion: PTD and rPTAo measured from CCT images were significantly correlated with mPAP in children. Reference curves and the formula of PTD and rPTAo adjusted for height could be practical for diagnosing PAH in children.

Modified analytical AI evolution of composite structures with algorithmic optimization of performance thresholds

  • ZY Chen;Yahui Meng;Huakun Wu;ZY Gu;Timothy Chen
    • Steel and Composite Structures
    • /
    • v.53 no.1
    • /
    • pp.103-114
    • /
    • 2024
  • This study proposes a new hybrid approach that utilizes post-earthquake survey data and numerical analysis results from an evolving finite element routing model to capture vulnerability processes. In order to achieve cost-effective evaluation and optimization, this study introduced an online data evolution data platform. The proposed method consists of four stages: 1) development of diagnostic sensitivity curve; 2) determination of probability distribution parameters of throughput threshold through optimization; 3) update of distribution parameters using smart evolution method; 4) derivation of updated diffusion parameters. Produce a blending curve. The analytical curves were initially obtained based on a finite element model used to represent a similar RC building with an estimated (previous) capacity height in the damaged area. The previous data are updated based on the estimated empirical failure probabilities from the post-earthquake survey data, and the mixed sensitivity curve is constructed using the update (subsequent) that best describes the empirical failure probabilities. The results show that the earthquake rupture estimate is close to the empirical rupture probability and corresponds very accurately to the real engineering online practical analysis. The objectives of this paper are to obtain adequate, safe and affordable housing and basic services, promote inclusive and sustainable urbanization and participation, implement sustainable and disaster-resilient buildings, sustainable human settlement planning and management. Therefore, with the continuous development of artificial intelligence and management strategy, this goal is expected to be achieved in the near future.

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

INDUSTRIAL MATHEMATICS IN ULTRASOUND IMAGING

  • JANG, JAESEONG;AHN, CHI YOUNG
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.20 no.3
    • /
    • pp.175-202
    • /
    • 2016
  • Ultrasound imaging is a widely used tool for visualizing human body's internal organs and quantifying clinical parameters. Due to its advantages such as safety, non-invasiveness, portability, low cost and real-time 2D/3D imaging, diagnostic ultrasound industry has steadily grown. Since the technology advancements such as digital beam-forming, Doppler ultrasound, real-time 3D imaging and automated diagnosis techniques, there are still a lot of demands for image quality improvement, faster and accurate imaging, 3D color Doppler imaging and advanced functional imaging modes. In order to satisfy those demands, mathematics should be used properly and effectively in ultrasound imaging. Mathematics has been used commonly as mathematical modelling, numerical solutions and visualization, combined with science and engineering. In this article, we describe a brief history of ultrasound imaging, its basic principle, its applications in obstetrics/gynecology, cardiology and radiology, domestic-industrial products, contributions of mathematics and challenging issues in ultrasound imaging.

Analysis of Surface flashover Depending on Gap Distance in Epoxy Region (에폭시 연면거리에 따른 파괴전압 분석)

  • Yoon, Jae-Hun;Lee, Sueng-Su;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.400-400
    • /
    • 2009
  • In a wide variety of high-voltage applications surface flashover plays major role in the system's performance and yet has not been studied in great detail for atmospheric conditions with modem diagnostic tools. surface flashover for both direct current and pulsed voltages in considered. within the setup, parameters such as geometry, material characteristics of the applied voltage can be altered. This paper review surface flashover of insulator, primarily in atmosphere. It discusses theories and models relating to surface flashover and experimental results. surface flashover of insulators in atmosphere generally is initiated by the emission of electrons from the cathode triple junction point (the region where the electrode, insulator, air). the electrode material was copper, and a AC voltage was applied between the electrodes. these results were compared with the surface flashover characteristic of epoxy.

  • PDF

Photoionization Models for Planetary Nebulae: Comparison of Predictions by NEBULA and CLOUDY

  • Lee, Seong-Jae;Hyung, Siek
    • Journal of the Korean earth science society
    • /
    • v.29 no.5
    • /
    • pp.419-427
    • /
    • 2008
  • The Galactic planetary nebulae emit many strong recombination and forbidden lines. By analyzing such lines, the physical condition of the planetary nebulae has been inferred using the strategically important diagnostic line ratios. In order to fully understand the physical condition of a planetary nebula and to derive its chemical abundances, the photoionization model codes, e.g., CLOUDY and NEBULA, were employed for an analysis of gaseous nebular spectra. For the well-studied, relatively simple planetary nebula NGC 7026, theoretical investigation was done with about the same input parameters in models. The predictions made by both codes seem to be in good accord. However, the predicted physical conditions, such as electron temperature and density, are slightly different. Especially, the electron temperatures are predicted to be higher in CLOUDY, which may cause a problem in chemical abundance determination. Our analysis shows that the main discordance may occur due to the diffuse radiation.

A Fault Diagnosis on the Rotating Machinery Using MTS (MTS 기법을 이용한 회전기기의 이상진단)

  • Park, Won-Sik;Lee, Hae-Jin;Lee, Jeong-Yun;Kim, Dong-Seop;O, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.770-773
    • /
    • 2007
  • As higher reliability and accuracy on production facilities are required to detect incipient faults, a diagnostic system for predictive maintenance of the facility is highly recommended. In this paper, it presents a study on the application of vibration signals to diagnose faults for a Rotating Machinery using the Mahalanobis Distance-Taguchi System. RMS, Crest Factor and Kurtosis that is known as the Statistical Methods and the spectrum analysis are used to diagnose faults as parameters of Mahalanobis distance.

  • PDF

Assay of Trace Gold Ion in a Skin Cell Using a Stripping Voltammetry

  • Ly, Suw-Young;Lee, Jin-Hui;Yi, Jae-Hun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.15-21
    • /
    • 2011
  • Threelectrodes systems were used in stripping voltammetry (SW) and cyclic voltammetry (CV) instead of the expensive platinum and Ag/AgCl reference electrodes. Moreover, the electrolyte solution was used with deep seawater, which can reduce water pollution, is more eco-friendly, and has a lower cost. The analytical optimum parameters measured via CV and SW and with working ranges were obtained from 10 to 80 ug/L using fluorine immobilized on a graphite pencil electrode (FE). Under the optimum conditions, the analytical detection limit of 6.30 ug/LAu was obtained. The results of the study can be applied to diagnostic assay for natural minerals and human finger tissue.