• 제목/요약/키워드: diagnostic parameters

검색결과 549건 처리시간 0.039초

Anatomical Site Classification for Implant Insertion:ASCIi

  • Jeong, Seung-Mi;Chung, Chae-Heon;Engelke, W.
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.321-327
    • /
    • 2000
  • Statement of Problem. As a standard means of diagnostics, an orthopantomogram(OPT) permits to measure the vertical and mesiodistal dimension of available bone at the desired implant site with the help of suitable radioopaque references. Based on the clinical investigation of the dentition and the edentulous sites, information upon the width of the implant site can be obtained and documented in the dental scheme. Both findings permit together systematic primary planning for endosteal implants. Purpose of Study. Contents of the present article are the representation of a semiquantitative classification of available bone with the aim to simplify the primary phase of a systematic implant planning. Results. Thus the ASCIi- system permits a clear protocol of bone findings for the implant case with all information available during the primary appointment for treatment planning as a basis of further diagnostic and therapeutic measures. Conclusion. With the ASCIi system, important parameters such as alveolar height and sub-crestal alveolar width can be documented systematically, easily and time saving in the dental scheme as a basis for exact treatment planning.

  • PDF

Identification of Open-Switch and Short-Switch Failure of Multilevel Inverters through DWT and ANN Approach using LabVIEW

  • Parimalasundar, E.;Vanitha, N. Suthanthira
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2277-2287
    • /
    • 2015
  • In recent times, multilevel inverters are given high priority in many large industrial drive applications. However, the reliability of multilevel inverters are mainly affected by the failure of power electronic switches. In this paper, open-switch and short-switch failure of multilevel inverters and its identification using a high performance diagnostic system is discussed. Experimental and simulation studies were carried out on five level cascaded H-Bridge multilevel inverter and its output voltage waveforms were analyzed at different switch fault cases and at different modulation index values. Salient frequency domain features of the output voltage signal were extracted using the discrete wavelet transform multi resolution signal decomposition technique. Real time application of the proposed fault diagnostic system was implemented through the LabVIEW software. Artificial neural network was trained offline using the Matlab software and the resultant network parameters were transferred to LabVIEW real time system. In the proposed system, it is possible to precisely identify the individual faulty switch (may be due to open-switch (or) short-switch failure) of multilevel inverters.

디지털진단의료영상 화질평가 프로그램 개발 (Development of Image Quality Evaluation Program for Digital Diagnostic Radiography)

  • 강보선
    • 한국방사선학회논문지
    • /
    • 제2권2호
    • /
    • pp.5-10
    • /
    • 2008
  • 최근의 진단의료용 방사선영상은 대부분 디지털영상으로 변환되었으나, 영상획득을 위한 조사조건 등 영상화질에 영향을 미치는 요소들에 관련하여서는 여전히 대부분 필름-스크린 시스템의 기준을 그대로 따르고 있으며, 실정이다. 뿐만 아니라 획득된 디지털영상에 대한 객관적인 화질평가 또한 임상에서 적용되고 있지 않은 실정이다. 본 연구에서는 디지털영상의 화질을 평가함에 있어 기본이 되는 요소인 화질의 균일성, NPS(noise power spectrum), MTF(modulation transfer function), NEQ(noise equivalent quanta) 등에 대한 평가를 임상에서 활용할 수 있도록 사용자 친화적인 윈도우 환경의 디지털영상화질 평가 프로그램을 MatLab을 이용하여 개발하였다.

  • PDF

촬상소자를 이용한 맥동의 2차원 계측 (2-dimensional Measurement of Arterial Pulse by Imaging Devices)

  • 김기왕
    • 대한한의진단학회지
    • /
    • 제12권2호
    • /
    • pp.8-17
    • /
    • 2008
  • Objectives: For the traditional pulse diagnosis in Oriental Medicine, not only the pulse shape in time domain, but the width, length and depth of arterial pulse also should be measured. However, conventional pulse diagnostic systems have failed to measure the spatial parameters of the arterial pulse e.g. effective length of arterial pulse in the wrist. In fact, there are many ways to measure that kind of spatial features in arterial pulsation, but among them, the method using image sensor provides relatively cheap and simple way, therefore I tested feasibility of measuring 2-dimensional pressure distribution by imaging devices. Methods: Using widely used PC cameras and dotted balloons, the subtle oscillation of skin over the radial artery was recorded continuously, and then the displacement of every dot was calculated. Consequently, the time course of that displacements shows arterial pulse wave. Results: By the proposed method I could get pressure distribution map with 30Hz sampling rate, 21steps quantization resolution, and approximately 1mm spatial resolution. With reduced quantization resolution, $3cm{\times}4cm$ view angle could be achieved. Conclusion: Although this method has some limitations, it would be useful method for detecting 2-dimensional features of arterial pulse, and accordingly, this method provides a novel way to detect 'narrow pulse', 'wide pulse', 'long pulse', 'short pulse', and their derivatives.

  • PDF

정상인 및 각종 갑상선 질환 환자의 혈청 Thyroxine (Determination of Serum Thyroxine Levels in Normal Korean Subjects and Various Thyroid Diseases)

  • 김동집;민병석;박용휘;김부성
    • 대한핵의학회지
    • /
    • 제3권2호
    • /
    • pp.33-38
    • /
    • 1969
  • The serum thyroxine levels were measured by method of Tetrasorb Kit in 69 subjects including 13 subjects in euthyroid state, 31 with hyperthyroidism, 5 with hypothyroidism, 13 with nontoxic diffuse goiter, and 7 with nontoxic nodular goiter. Three parameters of the thyroid function test including thyroxine ($T_4$) levels, $^{131}I$ uptake (24 hrs) values and $PB^{131}I$ conversion ratio were correlated with clinical manifestations and courses of the disease. 1. The serum $T_4$ levels in the normal subjects were in range of $6.0{\mu}g/dl\;to\;14.4{\mu}g/dl$. (The mean $9.4{\mu}g/dl$). 2. The diagnostic compatibility of the serum $T_4$ was 93.5% in hyperthyroidism, 100% both in hypothyroidism and in nontoxic diffuse goiter, 86% in nontoxic nodular goiter, or 95.8% in the entire series. (Table 1). 3. The diagnostic compatibility of $^{131}I$ uptake (24 hrs) values and $PB^{131}I$ conversion ratio were less than the serum $T_4$ levels as summarized in Tables 2 & 3. The serum $T_4$ determination by Tetrasorb Kit is a simple, accurate and very useful test of the thyroid function.

  • PDF

경동맥 죽상경화반의 고해상도 자기공명영상 (High-Resolusion Magnetic Resonance Imaging of Carotid Atherosclerotic Plaque)

  • 변우목;조재호
    • Journal of Yeungnam Medical Science
    • /
    • 제21권2호
    • /
    • pp.143-150
    • /
    • 2004
  • A thromboembolic stroke is believed to be precipitated by a rupture of vulnerable atheromatous plaques. Until recently the assessment of a further risk of stroke in high-risk patients in whom atherosclerosis has presented with a transient ischaemic attack (TIA), has been confined to a quantitative assessment of the luminal patency of the internal carotid artery. These traditional stratification parameters are no longer believed to be the most accurate predictors of a thrombo-embolism. This is because the process of vessel wall remodeling can maintain a luminal patency, and consequently, quite large friable plaques may remain unidentified. Accordingly, there is a need for an improved risk assessment. The fibrous cap of a vulnerable plaque is thinner, and an intraplaque hemorrhage and inflammation can occur during the development of atherosclerotic plaque. Several imaging methods for identifying vulnerable plaques have been developed. Recently, high resolution magnetic resonance (MR) imaging has emerged as an accurate non-invasive tool that can characterize the carotid plaque components in vivo. A High resolution carotid magnetic resonance is capable of distinguishing an intact, thick fibrous cap from a thin and ruptured cap in carotid plaque. In addition, a plaque MR can identify the active inflammation and detect a hemorrhage. High resolution carotid MR imaging is a valuable noninvasive method for quantifying the plaque components and identifying vulnerable plaque.

  • PDF

Pharmacognostical Evaluation of Leucas aspera Link.

  • Rai, Vartika;Agarwal, Manisha;Agnihotri, A.K.;Khatoon, S.;Rawat, A.K.S.;Mehrotra, S.
    • Natural Product Sciences
    • /
    • 제11권2호
    • /
    • pp.109-114
    • /
    • 2005
  • Leucas aspera Link. (Lamiaceae) is an important medicinal plant in indigenous systems of medicine in India and commonly known as 'Thumbai'. It has various ethnomedicinal values as various traditional communities find diverse medicinal properties. It is used as antipyretic, stimulant, expectorant and diaphoretic drug. The present communication deals with the detailed pharmacognostical evaluation of whole plant of L. aspera collected from five different geographical zones of the country-Uttar Pradesh, Orissa, Karnataka, West Bengal and Gujarat. The botanical characters and TLC fingerprint profile of all the samples were quite similar but some variations were observed in physicochemical parameters. However, some microscopical characters and TLC profile can be used as diagnostic characters for identification of L. aspera, for example amphistomachic leaves and two types of trichomes-abundant, non glandular, uniseriate, 1-3 celled and few glandular, 2-5 celled stalk with rounded tip. Presence of some components at $R_fs-0.56$, 0.65 and 0.76 under UV 366 and at $R_fs-0.31$, 0.43, 0.60, 0.76 and 0.82 under visible light after derivetization in TLC profile may also be used as diagnostic character.

Knowledge Based Recommender System for Disease Diagnostic and Treatment Using Adaptive Fuzzy-Blocks

  • Navin K.;Mukesh Krishnan M. B.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제18권2호
    • /
    • pp.284-310
    • /
    • 2024
  • Identifying clinical pathways for disease diagnosis and treatment process recommendations are seriously decision-intensive tasks for health care practitioners. It requires them to rely on their expertise and experience to analyze various categories of health parameters from a health record to arrive at a decision in order to provide an accurate diagnosis and treatment recommendations to the end user (patient). Technological adaptation in the area of medical diagnosis using AI is dispensable; using expert systems to assist health care practitioners in decision-making is becoming increasingly popular. Our work architects a novel knowledge-based recommender system model, an expert system that can bring adaptability and transparency in usage, provide in-depth analysis of a patient's medical record, and prescribe diagnostic results and treatment process recommendations to them. The proposed system uses a set of parallel discrete fuzzy rule-based classifier systems, with each of them providing recommended sub-outcomes of discrete medical conditions. A novel knowledge-based combiner unit extracts significant relationships between the sub-outcomes of discrete fuzzy rule-based classifier systems to provide holistic outcomes and solutions for clinical decision support. The work establishes a model to address disease diagnosis and treatment recommendations for primary lung disease issues. In this paper, we provide some samples to demonstrate the usage of the system, and the results from the system show excellent correlation with expert assessments.

신경회로망을 이용한 스마트 무인기용 가스터빈 엔진의 성능진단에 관한 연구 (A Study on Performance Diagnostic of Smart UAV Gas Turbine Engine using Neural Network)

  • 공창덕;기자영;이창호;이승현
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.213-217
    • /
    • 2006
  • PW206C 터보 축 엔진을 위해 신경회로망을 이용한 지능형 성능 진단 프로그램이 제안되었다. 이 엔진은 항공우주연구원에서 개발 중에 있는 틸트 로터 타입 스마트 무인기의 추진시스템으로 선정되었다. 1개의 은닉층, 입력층, 출력층을 가지는 BPN(Back Propagation Network)이 신경회로망을 훈련시키기 위해 이용되었다. 입력층은 7개의 뉴런을 가지는데 SHP, MF, P2, T2, P4, T4 및 T5와 같은 측정파라미터이며 출력층은 6개의 뉴런으로 구성되어 있으며 각각은 압축기, 압축기 터빈, 동력 터빈의 유량 함수 및 효율이다. 신경망을 훈련하고 테스트하기 위한 데이터 베이스는 가스터빈 성능모사 프로그램을 이용하여 구성하였다. 훈련된 신경망을 PW206C 터보 축 엔진의 진단에 적용한 결과 제안된 진단 알고리즘이 압축기 오염과 압축기 터빈의 침식과 같은 단일 손상을 탐지하는데 유용함을 확인하였다.

  • PDF

환경적 요인과 연관된 진동 파라메터를 진단하기 위한 이동평균 예측 진단 모듈 개발 (Development of Moving Average Prediction Diagnostic Module for Vibration Parameter Influenced by Environmental Factors)

  • 오세도;김영진;이태휘
    • 대한기계학회논문집A
    • /
    • 제37권6호
    • /
    • pp.797-804
    • /
    • 2013
  • 본 논문에서는 환경 요인에 영향을 받아 평균이동이 발생하는 진동 파라메터에 대한 진단 방법을 연구하였다. 양산라인에서는 측정 시점에 따라 변화되는 환경요인에 대응되어 측정된 진동 파라메터의 평균이 변화될 수 있다. 이러한 경우 기존에 널리 사용되는 고정된 관리한계선을 사용하는 진단 기법을 사용할 경우 시간이 흐름에 따라 오분류가 발생한다. 이 한계점을 극복하기 위해 저자들은 회귀분석을 활용해 평균 변화의 주요 원인이 되는 환경요인간의 함수관계를 규명하고, 이를 평균이동의 예측에 활용해 각 진단 시점별로 경계 상한과 하한을 유연하게 변경하는 방법론을 제안한다. 제안된 방법론은 적용 과정에서 필요한 모수의 설정 시 레퍼런스 데이터 평가를 통해 합리적인 모수를 추정하는 것이 가능하고, 환경이 변화되는 각 시점에서 데이터에 대해 유연한 진단을 보장한다. H사의 디젤엔진 생산라인의 엔진 진동 검사 데이터를 활용하여 본 논문의 방법론에 대한 검증을 실시하였으며 만족스러운 결과를 도출하였다.