• 제목/요약/키워드: diagnostic parameters

검색결과 549건 처리시간 0.025초

The Study of Possibility of Finding a Reagent for Cancer Diagnosis by Urine NMR Measurement

  • Kim, Yong-J.
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권1호
    • /
    • pp.35-40
    • /
    • 1986
  • For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm.

  • PDF

Saccadic 안구운동 해석에 대한 통계학적인 접근 (A Statistical Approach to Analysis of Saccadic Eye Movements)

  • Kim, Nam-Gyun;Kim, Bu-Gil
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권3호
    • /
    • pp.289-292
    • /
    • 1989
  • In this study we propose an approach based on statistical method which use the whole of saccades instead of using a few points of saccades in the quantitative analyse saccades. We computed statistical parameters such as mean velocity, quadratic mean velocity, standard duration, skewness of saccades velocity, flattness factor of saccades velocity, and mean delay by considering eye velocity as a probability density function. The results abtained are the following as ; This parameters showed the same trend like that of the main sequence. They were not biased by the systematic errors due to the arbitrary threshold. They were also less sensitive to noise, which was tested through the model simulation. So they are expected to provide a more comprehensive quantitative description of the dynamic properties of saccade in the diagnostic field.

  • PDF

Tribological diagnostics of machinery

  • Myshkin, N.K.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1990년도 제11회 학술강연회초록집
    • /
    • pp.7-31
    • /
    • 1990
  • Tribologicsl diagnostics as the ensemble of means and methods of continuous monitoring of the state of friction characteristics of moving junctions is playing an ever important part in the development of friction, lubrication, and wear theory end practice. The scheme presenting the main areas of tribological diagnostics is given in Fig. I. This growing part of TD is determined by the general tendency of modern technology, expressed in an attempt to organically combine the functions of measuring, evaluating,and predicting the parameters and characteristics of the processee taking place in the operating device. The logical result of this integration in future is the closed system correcting its operation in accordance with sn established program. Unfortunately, tribotechnicsl devices are still very far from such an ideal system at the present time. While in the friction assemblies with hydrodynamic lubrication it is possible in the first approximation to realize feed-backs in the lubricant circulation system with the aid of monitoring of the pressure, temperature and filtration, in the systems operating without lubrication and with boundary lubricetion even the process of selection of the diagnostic parameters has not been completed.

  • PDF

자율 최적 성형 공정 시스템 개발 (A Concept of Self-Optimizing Forming System)

  • 박홍석;;송준엽;김동훈
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.292-297
    • /
    • 2013
  • Nowadays, a strategy of the self-optimizing machining process is an imperative approach to improve the product quality and increase productivity of manufacturing systems. This paper presents a concept of self-optimizing forming system that allows the forming system automatically to adjust the forming parameters online for guarantee the product quality and avoiding the machine stop. An intelligent monitoring system that has the functions of observation, evaluation and diagnostic is developed to evaluate the pully quality during forming process. Any abnormal variation of forming machining parameters could be detected and adjusted by an intelligent control system aiming to maintain the machining stability and the desired product quality. This approach is being practiced on the pully forming machine for evaluating the efficiency of the proposed strategy.

Micro-hardness and Young's modulus of a thermo-mechanically processed biomedical titanium alloy

  • Mohammed, Mohsin Talib;Khan, Zahid A.;M., Geetha;Siddiquee, Arshad N.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제1권3호
    • /
    • pp.117-130
    • /
    • 2014
  • This paper presents a study on the influence of different thermo-mechanical processing (TMP) parameters on some required properties such as micro-hardness and Young's modulus of a novel near ${\beta}$ alloy Ti-20.6Nb-13.6Zr-0.5V (TNZV). The TMP scheme comprises of hot working above and below ${\beta}$ phase, solutionizing treatment above and below ${\beta}$ phase coupled with different cooling rates. Factorial design of experiment is used to systematically collect data for micro-hardness and Young's modulus. Validity of assumptions related to the collected data is checked through several diagnostic tests. The analysis of variance (ANOVA) is used to determine the significance of the main and interaction effects. Finally, optimization of the TMP process parameters is also done to achieve optimum values of the micro-hardness and Young's modulus.

ECG 특징추출을 위한 파이프라인 프로세서의 설계 (Design of Pipeline Processor for ECG Feature Extraction)

  • 이경중;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제9권1호
    • /
    • pp.79-86
    • /
    • 1988
  • This paper describes the design of a hardware systenl for ECG feature extraction based on pipeline processor consistinsf of three microcomputers. ECG data is acquisited by 12 bit A/D converter with hardware QRS triggered detector. Four diagnostic parameters parameters-heart rate, morPhology, axis, and 57 segment-are used for the classification and the diagnosis of arrhythmia. The functions of the main CPU were distributed and processed with three microcomputers. Therefore the effective data process and the real time process using microcomputer can be obtained. The interconnection structure consisting of two common memory units is designed to decrease the delay time caused by data transfer between processors and designed by which the delay time can be taken Loye of one clock period.

  • PDF

Radial Basis Function 네트워크를 이용한 PVC 분류 (Classification of PVC(Premature Ventricular Contraction) using Radial Basis Function network)

  • 이전;이경중
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.439-442
    • /
    • 1997
  • In our research, we will extract diagnostic parameters by LPC method and wavelet transform. Then, we will design artificial neural network which is based on RBF that can express input features in terms of fuzzy. Because PVC(Premature Ventricular Contraction) has possibility to cause heart attack, the detection of PVC is a very significant problem. To deal with this problem, LPC method which gives different coefficients or different morphologies and wavelet transform which has superior localization nature of time-frequency, are used to extract effective parameters or classification of normal and PVC. Because RBF network can allocate an input feature to the membership degree of each category, total system will be more flexible.

  • PDF

AR 모델을 이용한 심음의 진단적 특성에 관한 연구 (Research on diagnostic property of heart sound using AR model)

  • 김형석;백승화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2486-2488
    • /
    • 1998
  • In this paper, Prameters esimated t using AR model in order to approach linearly the heart sound which include the nonlinear characteristic from the characteristics based on a statistical theory. The parameters which is figured out using AR model is a very important information which show the characteristic heart sound In this paper parameters estimated using autocorrelation method and order selected by proposed Akaike[6] method. Compared the similirities of the spectrums between estimated by using AR model and estimated by using FFT method.

  • PDF

한의학적 활용을 위한 임피던스 심장기록법의 연구동향 (A Review on Impedance Cardiography and Its Oriental Medical Application)

  • 고영일;이현수;박영재;박영배
    • 대한한의진단학회지
    • /
    • 제10권2호
    • /
    • pp.67-78
    • /
    • 2006
  • Objectives : To review the method, validity and reliability of Impedance Cardiography and to study its oriental medical application. Method : The papers reviewed in this study were searched through internet search engines such as Springer, Science Direct, and China National Knowledge Infrastructure. Conclusion : In this study, the methodological limitations, validity and reliability of impedance cardiography were examined. Impedance Cardiography is recognized as a highly accurate non-invasive tool to assess hemodynamic parameters. The ability of impedance cardiography to assess hemodynamic parameters in non-invasive way is very suitable for researches on the effect of oriental medical therapeutics or the validation of oriental medical diagnostic.

  • PDF

기능성 소화불량 환자의 한방치료 전후의 주관적 평가지표와 Electrogastrography Parameters를 이용한 객관적 지표의 변화 관찰 (Clinical Observation of Changes in Subjective Evaluation Index and Electrogastrography Parameters of Patients with Functional Dyspepsia before and after Oriental Medical Interventions)

  • 한가진;김진성;류봉하
    • 대한한방내과학회지
    • /
    • 제32권4호
    • /
    • pp.584-598
    • /
    • 2011
  • Objectives : Functional dyspepsia is a type of disease characterized by bothersome postprandial fullness, early satiation, epigastric pain and burning without structural gastrointestinal disease. The aim of this study was to analyze the characteristics of functional dyspepsia patients and evaluate changes in symptoms, quality of life, and electrogastrography parameters before and after oriental medical interventions. Methods : We recruited forty-six functional dyspepsia patients who visited gastroenterology clinic in the oriental medicine hospital of Kyung Hee University between November 2009 and February 2011. Patients were assessed for their frequency of dyspepsia (based on short form-Leeds Dyspepsia Questionnaire: SF-LDQ), quality of life (based on functional dyspepsia-related quality of life questionnaire: FD-QoL), gastric motility (based on electrogastrography: EGG) on the first visit. Then, the effect of oriental medical interventions was evaluated using EGG on the second visit. Results : The majority of patients had symptoms of nausea and indigestion. The largest decrease in EGG parameters was found in the indigestion group. The frequency of regurgitation and postprandial EGG power % bradygastria showed a significant correlation. Also, significant correlations were found between some items of FD-QoL and some EGG parameters. Compared to the EGG parameters before oriental medical interventions, some parameters after treatment had positive results, implying the improvement of gastric motility disorder. We also found improvement of EGG parameters in both digestant medicinal group and digestant combined with qi-tonifying medicinal group. Conclusions : The results of this study suggest that clinical application of EGG can be an objective diagnostic tool in functional dyspepsia patients visiting oriental medical hospital.