• Title/Summary/Keyword: diagnosis architecture

Search Result 214, Processing Time 0.027 seconds

Comparison of Prediction Accuracy Between Classification and Convolution Algorithm in Fault Diagnosis of Rotatory Machines at Varying Speed (회전수가 변하는 기기의 고장진단에 있어서 특성 기반 분류와 합성곱 기반 알고리즘의 예측 정확도 비교)

  • Moon, Ki-Yeong;Kim, Hyung-Jin;Hwang, Se-Yun;Lee, Jang Hyun
    • Journal of Navigation and Port Research
    • /
    • v.46 no.3
    • /
    • pp.280-288
    • /
    • 2022
  • This study examined the diagnostics of abnormalities and faults of equipment, whose rotational speed changes even during regular operation. The purpose of this study was to suggest a procedure that can properly apply machine learning to the time series data, comprising non-stationary characteristics as the rotational speed changes. Anomaly and fault diagnosis was performed using machine learning: k-Nearest Neighbor (k-NN), Support Vector Machine (SVM), and Random Forest. To compare the diagnostic accuracy, an autoencoder was used for anomaly detection and a convolution based Conv1D was additionally used for fault diagnosis. Feature vectors comprising statistical and frequency attributes were extracted, and normalization & dimensional reduction were applied to the extracted feature vectors. Changes in the diagnostic accuracy of machine learning according to feature selection, normalization, and dimensional reduction are explained. The hyperparameter optimization process and the layered structure are also described for each algorithm. Finally, results show that machine learning can accurately diagnose the failure of a variable-rotation machine under the appropriate feature treatment, although the convolution algorithms have been widely applied to the considered problem.

A Basic Study on The Seismic Capacity Evaluation and Repair Reinforcement in Cultural Assets : Focused on Wooden Structure Cultural Assets in Korea and Japan (문화재 내진진단과 보수·보강에 관한 기초적인 연구 -한국과 일본의 목조 건조물 문화재를 중심으로-)

  • Hong, Ji-Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.488-495
    • /
    • 2016
  • The purpose of this study is to improve the repair and reinforcement of cultural construction assets made of wood and develop seismic countermeasures. The existing regulations for the earthquake proofing of cultural assets are termed 'Regulations concerning earthquake disasters affecting cultural assets' of the cultural heritage administration, which only specifies the reporting of damage to cultural assets after the occurrence of an earthquake. Since 2013, Korea has been studying the introduction of a seismic evaluation system consisting of experts by referring to the 'Guideline for the diagnosis and reinforcement of important cultural properties in Japan. The earthquake proofing of wooden cultural assets in Japan is assessed by experts using a scoring system similar to the one in Korea, but the system in Japan is managed in three steps, viz. before, during and after the occurrence of the earthquake. In order to extend the existing management system by focusing on the repair of the damage after the occurrence of an earthquake, it is necessary for Korea to cultivate experts for the regular management of cultural assets, establish seismic criteria for them, and introduce a regular management system through a civil organization related to construction. By examining the current status of wooden cultural assets, it is necessary to develop various seismic diagnosis techniques and produce guidelines for the repair and reinforcement of individual wooden cultural construction assets following their identification.

Analysis of Magnetic Flux Leakage based Local Damage Detection Sensitivity According to Thickness of Steel Plate (누설자속 기반 강판 두께별 국부 손상 진단 감도 분석)

  • Kim, Ju-Won;Yu, Byoungjoon;Park, Sehwan;Park, Seunghee
    • Journal of Korean Society of Disaster and Security
    • /
    • v.11 no.2
    • /
    • pp.53-60
    • /
    • 2018
  • To diagnosis the local damages of the steel plates, magnetic flux leakage (MFL) method that is known as a adaptable non-destructive evaluation (NDE) method for continuum ferromagnetic members was applied in this study. To analysis the sensitivity according to thickness of steel plate in MFL method based damage diagnosis, several steel plate specimens that have different thickness were prepared and three depths of artificial damage were formed to the each specimens. To measured the MFL signals, a MFL sensor head that have a constant magnetization intensity were fabricated using a hall sensor and a magnetization yoke using permanent magnets. The magnetic flux signals obtained by using MFL sensor head were improved through a series of signal processing methods. The capability of local damage detection was verified from the measured MFL signals from each damage points. And, the peak to peak values (P-P value) extracted from the detected MFL signals from each thickness specimen were compared each other to analysis the MFL based local damage detection sensitivity according to the thickness of steel plate.

Diagnosis of the growth status and actual condition of the remaining old trees in the village - Focused on Hyeongok-myeon in Gyeongju-si - (마을 내 잔존 노거수의 생육현황 및 실태진단 - 경주시 현곡면을 중심으로 -)

  • Kim, Young-Hun;Deng, Bei-Jia;Chen, Geng;You, Ju-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.6
    • /
    • pp.109-123
    • /
    • 2020
  • The purpose of this study is to provide basic data for the establishment of future countermeasures by diagnosing the growth status and actual condition of undesignated old trees distributed in Hyeongok-myeon, Gyeongju, Gyeongsangbuk-do. The number of old trees surveyed was 2 weeks in Gajeong-ri, 2 weeks in Haguri, 3 weeks in Nae-Tae-ri, 1 week in Nawon-ri, 6 weeks in Oryu-ri, 3 weeks in Sangguri, and 2 weeks in Sohyeon-ri, The trees species composition was 6 trees Celtis sinensis Pers., 1 Diospyros lotus L. trees, 4 trees Salix chaenomeloides Kimura trees, 2 Styphnolobium japonicum L. trees, and 7 Zelkova serrata (Thunb.) Makino trees. Growth status is 7.1~22.0m in height, 14.6~25.1m in long axis, 10.2~19.2m in short axis, root diameter is 76.0~236.4cm, diamter at breast height is 67.0~220.0cm, soil acidity is pH4.9~7.0, soil The hardness was measured to be 4.0-27.0mm. The result grade of the scoring data of health information is represented by monitoring generally, monitoring critically, and absolute monitoring, and it was confirmed that out of the 20 trees population in Hyeongok-myeon, the general monitoring grade was 7 weeks, the major monitoring grade was 13 weeks, and there was no absolute monitoring grade. Accordingly, the number of old trees of the general surveillance level was maintained at the current level, and ecological surgical operations were introduced for the major surveillance level, but the case of village forests should be different, and sequential treatments were the old tree urgently needed. The level and bark of the target tree, the state of the crown, the root exposure, the presence of pests and pests, the vitality and the ground condition, the degree of pollution are normal, poor, or very poor, operation and protection management, soil improvement, removal of cover, and disinfection were urgently needed for the old trees with the surveyed data. In order to compensate for these matters, continuous monitoring and management measures for the old number should be sought.

Computational Analysis of Tumor Angiogenesis Patterns Using a Growing Brain Tumor Model

  • Shim, Eun-Bo;Kwon, Young-Keun;Ko, Hyung-Jong
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.1
    • /
    • pp.17-24
    • /
    • 2004
  • Tumor angiogenesis was simulated using a two-dimensional computational model. The equation that governed angiogenesis comprised a tumor angiogenesis factor (TAF) conservation equation in time and space, which was solved numerically using the Galerkin finite element method. The time derivative in the equation was approximated by a forward Euler scheme. A stochastic process model was used to simulate vessel formation and vessel elongation towards a paracrine site, i.e., tumor-secreted basic fibroblast growth factor (bFGF). In this study, we assumed a two-dimensional model that represented a thin (1.0 mm) slice of the tumor. The growth of the tumor over time was modeled according to the dynamic value of bFGF secreted within the tumor. The data used for the model were based on a previously reported model of a brain tumor in which four distinct stages (namely multicellular spherical, first detectable lesion, diagnosis, and death of the virtual patient) were modeled. In our study, computation was not continued beyond the 'diagnosis' time point to avoid the computational complexity of analyzing numerous vascular branches. The numerical solutions revealed that no bFGF remained within the region in which vessels developed, owing to the uptake of bFGF by endothelial cells. Consequently, a sharp, declining gradient of bFGF existed near the surface of the tumor. The vascular architecture developed numerous branches close to the tumor surface (the brush-border effect). Asymmetrical tumor growth was associated with a greater degree of branching at the tumor surface.

  • PDF

Usefulness of Narrow Band Imaging Endoscopy in the Diagnosis of Head and Neck Cancer : A Prospective Study (두경부암 진단의 새로운 내시경 진단방법 협대역 영상(Narrow Band Imaging, NBI)의 유용성-전향적 연구)

  • Park, Jae-Hong;Kim, Jae-Wook;Lee, Yong-Man;Yoo, Hye-Jin;Tae, Kee-Yeun;Oh, Cheon-Whan;Chang, Hyuck-Soon;Lee, Seung-Won
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.2
    • /
    • pp.210-214
    • /
    • 2011
  • Background and Objectives : Narrow Band Imaging(NBI) is a novel optical technique that enhances the visualization of superficial microvascular architecture which is commonly increased and founded as an irregular shape in a neoplastic lesion. The aim of this study is the evaluation of the usefulness of NBI in the diagnosis of Head and Neck Cancer. Subjects and Methods : From December 2009 to January 2011, 31 consecutive patients who were diagnosed with head and neck malignancy were enrolled in this prospective study. The malignant findings of NBI were demarcated brownish lesion or increased intraepithelial papillary capillary loops(IPCLs) with or without irregularity. Results : There were 29 cases(93.5%) of well demarcated brownish lesion, 26 cases(83.9%) of increased IPCLs and 4 cases(12.9%) of satellite lesions. Diagnostic accuracy of endoscopic examination was increased from 83.9% to 93.5%, when NBI was applied to the conventional endoscopy(p>0.05). Conclusion : NBI is a powerful and safe screening test, which can be performed in out patient clinic without any supplementary procedure.

Ultrasonographic Guidance in Acute Achilles Tendon Rupture (급성 아킬레스 건 파열에서의 초음파 이용)

  • Lee, Tae-Hoon;Lee, Hee-Dong;Kim, Hak-Jun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.8 no.1
    • /
    • pp.26-30
    • /
    • 2015
  • There are many traumatic foot and ankle problems in orthopaedic fields. Though it is not life-threatening problems, a delay in accurate diagnosis and treatments can danger limb function and therefore correct diagnosis can prevent long-term complications. Achilles tendon rupture is relatively common injury for active sports people. Ultrasonography is cost-effective, irradiation -free, effective for evaluation of soft tissues and dynamic analysis. It has been growing importance in Achilles tendon rupture. Ultrasonography is a diagnostic tool in Achilles tendon rupture. Physical examination and patient history is needed to diagnose Achilles tendon without image, but it is missed up by 20% in private clinic. Discontinuity of normal fibrillar architecture seen on an ultrasonographic image is diagnostic for Achilles tendon rupture, and can be accentuated by the performance of dorsi-flexion and plantar flexion, while observing in real time. And ultrasonography is a reliable method for serial observation after surgical treatment or conservative treatment.

  • PDF

Wireless Digital Stethoscope Diagnosis System using Heart Rate (심박수를 이용한 무선 디지털 청진 진단시스템)

  • Park, Kee-Young;Lee, Jong-Ha;Cho, Sook-Jin;Lee, Chul-Hee;Jung, Eui-Bung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.237-243
    • /
    • 2014
  • Heart sounds of patient's chest could be heard using an analog stethoscope. However, auscultation of a heart sound can be diagnosed differently by each doctor hearing it. Therefore the condition of each patient is determined by the subjective comments based on the hearing ability of a physician who has years of experience. In this paper, through analysis of heart sound and heart rate of the patient's condition, we will define minutely how to diagnose the condition of patient using a wireless digital stethoscope diagnostic system. And it is possible to perform an objective medical diagnosis by applying LCR (Level Crossing Rate) and to show the relationship of a disease using this system.

Whether Pinhole Scan or Single Photon Emission Computed Tomography (SPECT) in the Diagnosis of Bone and Joint Diseases (골격계진단에 있어서 핀홀스캔의 우월성)

  • Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 1996
  • Since the publication of the first bone scintiscans in 1962 three decades have elapsed. The bone scan has made great strides during this period, becoming one of the most commonly used nuclear imaging tests. In spite of the progress, however, the specificity of bone scan has remained relatively low. As the result it is a common practice to seek additional information from radiograph, CT scan and MR image, which is euphemistically termed as "image fusion or co-location." The basic reason is the inapplicability of the classical piecemeal analysis to interpreting planar and SPECT bone scans. Such analysis has its base on the observation of elemental features of morphology, which include the size, shape, contour, location, topography and internal architecture. The physiochemical profile may well also be included. Understandably, however, the miniatured images of the planar bone scan cannot provide these features in acceptable detail and the same holds true even with SPECT Images which are but sliced views of the reconstructed planar scans. Fortunately pinhole scanning has the capacity to portray both the morphological and chemical profiles of bone and joint diseases in greater detail through true magnification. The magnitude of pinhole scan resolution is practically comparable to that of radiography as far as gross anatomy is concerned. Thus, we feel strongly that pinhole scanning is a potential breakthrough of the long-lamented low specificity of bone scan. This presentation will discuss the fun-damentals, advantages and disadvantages and the most recent advances of pinhole scanning. It high-lights the actual clinical applications of pinhole scanning in relation to the diagnosis of infective and inflammatory diseases of bone and joint.

  • PDF

Design of Network-Based Induction Motors Fault Diagnosis System Using Redundant DSP Microcontroller with Integrated CAN Module (DSP 마이크로컨트롤러를 사용한 CAN 네트워크 기반 유도전동기고장진단 시스템 설계)

  • Yoon, Chung-Sup;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.80-86
    • /
    • 2005
  • Induction motors are a critical component of many industrial processes and are frequently integrated in commercially available equipment. Safety, reliability, efficiency, and performance are some of the major concerns of induction motor applications. Fault tolerant control (FTC) strives to make the system stable and retain acceptable performance under the system faults. All present FTC method can be classified into two groups. The first group is based on fault detection and diagnostics (FDD). The second group is includes of FDD and includes methods such as integrity control, reliable stabilization and simultaneous stabilization. This paper presents the fundamental FDD-based FTC methods, which are capable of on-line detection and diagnose of the induction motors. Therefore, our group has developed the embedded distributed fault tolerant and fault diagnosis system for industrial motor. This paper presents its architecture. These mechanisms are based on two 32-bit DSPs and each TMS320F2407 DSP module processes the stator current, voltage, temperatures, vibration signal of the motor.