• Title/Summary/Keyword: dew sensor

Search Result 15, Processing Time 0.023 seconds

A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구)

  • 임재한;여명석;양인호;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

Implementation of Flooding Routing Protocol for Field sever using Weather Monitoring System (국지기상 모니터링용 필드서버를 위한 플러딩 라우팅 프로토콜의 구현)

  • Yoo, Jae-Ho;Lee, Seung-Chul;Chung, Wan-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.1
    • /
    • pp.233-240
    • /
    • 2011
  • A field server was developed by using ubiquitous sensor network technology to monitor the abrupt weather variation in local or mountain area. The data transmissions between deployed field servers in local terrain are very important technology in disaster prevention monitoring system. Weather related information such as temperature, humidity, illumination, atmospheric pressure, dew point and meteorological data are collected from the designated field at a regular interval. The received information from the multiple sensors located at the sensor field is used flooding routing protocol transmission techniques and the sensing data is transferred to gateway through multi-hop method. Telosb sensor node are programmed by nesC language in TinyOS platform to monitor the weather parameters of the local terrain.

Design of WSN based Field Server for Local Weather Monitoring (국지기상 모니터링을 위한 WSN 기반 필드서버 제작)

  • An, Seong-Mo;Kim, Jae-Gyeong;Yoo, Jae-Ho;Jung, Sang-Joong;Chung, Wan-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.493-500
    • /
    • 2011
  • Recently, there has been an increase in the number of disaster victims locally due to climate change and a variety of frequently occurring natural disasters. The damage caused by abrupt weather change in local area by typical weather forecasting techniques is very limited and difficult. Recently local area weather monitoring system using wireless sensor network technology has been very actively studied. Thus an IEEE 802.15.4-based weather field server to measure and monitor the local weather changes was designed and developed in this study. The proposed weather field server utilizes a wireless sensor node and weather sensors to collect weather information such as temperature, humidity, illumination, dew point, barometric pressure, and water level. The integrated weather sensor board was designed to respond quickly to weather changes, and provide feedback to the server PC. Each weather information is analyzed in the server PC to establish a program to monitor and analyze the local area or the area of abrupt climate change in order to provide warning signals in case of disaster events in local.

Coastal and Marine Environment Monitoring System using Flooding Routing Protocol (플러딩 라우팅 프로토콜을 이용한 연안.해양 환경모니터링 시스템)

  • Yoo, Jae-Ho;Lee, Seung-Chul;Kim, Jong-Jin;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.180-183
    • /
    • 2011
  • Recently, environmental problems have been deteriorating rapidly. Therefore, there is an urgent need to establish policies and research in the conservation of the global environment. Many researchers are studied in environment systems to prevent and reduce pollution of water, air and soil actively. In this paper, several parameters such as temperature, humidity, illumination, barometric pressure, dew point, water quality data, and air conditions are collected and transmitted thorough wireless sensor network. The field server is located in the coastal and marine area so that any abrupt changes can be detected quickly. In addition, WSN based flooding routing protocol for efficient data transmission is designed to support and monitor information of climate and marin factors.

  • PDF

Humidity Sensitive Properties of Copolymers of Polystyrene Contains Phosphonium Salts (포스포늄 염을 포함한 폴리스티렌 공중합체의 감습 성질)

  • Paek, Jee-Seon;Gong, Myoung-Seon
    • Korean Journal of Materials Research
    • /
    • v.5 no.6
    • /
    • pp.715-722
    • /
    • 1995
  • Vinylbenzyl triphenyl phosphonium chloride (VTPC) was prepared for the humid membrane. The humidity sensitive memo)lane was composed of copolymers, which have differnet content of VTPC and styrene (VTPC : ST=1 : 0.7 : 3, 5 : 5, 3 : 7). The changes in electrical properties of copolymers with relative humidity were measured. It was found that the impedance decreased with an increase of the content of VTPC in the humid membrane, and the Impedance also decreased with an increase of thickness of humid membrane. The copolymer derived from same equip of VTPC and ST showed 12M$\Omega$-100M$\Omega$ at 70%RH-90%RH, which was required for the current humidity sensor operating at high humidity or dew point. The temperature dependence coefficient at a temperature range 15$^{\circ}C$∼35$^{\circ}C$ was found to be -0.5%RH/$^{\circ}C$ and the hysterisis fabled within the range ${\pm}$2%RH. The response time was found to be 40seconds for varing relative humidity from 75% RH to 95%RH and vice versa.

  • PDF