• 제목/요약/키워드: device-to-device (D2D)

검색결과 1,724건 처리시간 0.031초

Effect of Using Progesterone Releasing Intravaginal Device with Ovsynch Program on Reproduction in Dairy Cattle during Summer Season

  • Alnimer, M.;Lubbadeh, W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권9호
    • /
    • pp.1268-1273
    • /
    • 2003
  • Sixty postpartum lactating Friesian cows in 3 treatments at a commercial dairy farm were used to study the effect of using progesterone supplementation with GnRH and PGF2$\alpha$ synchronization with and without timed AI on fertility during summer. Cows in treatment1($Tr_1$) and treatment2 ($Tr_1$) were fitted with progesterone releasing intravaginal device (PRID) device and injected with 10 g GnRH agonist on $51{\pm}3$ d postpartum (pp). Seven days later, PRID was removed and cows received 25 mg PGF2$\alpha$. Two days later, $Tr_1$ cows received another injection of 10 g GnRH and timed AI 16-20 h later. Control cows received only 25 mg PGF2$\alpha$ $58{\pm}3d\;pp$. $Tr_2$ and control cows were AI at detected estrus. Serum progesterone for all cows was determined on days of injection, AI and 21, 23 and 28 d postinsemination. Pregnancy rates from first AI based on serum P4 concentrations on d 21, 23 and 28 postinsemination (50, 40 and 35%) and that based on rectal palpation 40-45 d postinsemination (30, 15 and 15% for $Tr_1$, $Tr_2$ and control cows, respectively) did not differ among the three groups. Whereas, pregnancy rate at 120 d pp for $Tr_1$ (65%) was higher (p<0.05) than that in $Tr_2$ (30%) or control (30%). The overall pregnancy rate was not significantly different (90, 90 and 75% for $Tr_1$, $Tr_2$ and control, respectively). Days open for cows in $Tr_1$ ($100.3{\pm}9$) was less (p<0.03) than that in $Tr_2$ ($130.9{\pm}9$) or control ($135.1{\pm}10$). Results indicate that using PRID device with Ovsynch program had significantly increased pregnancy rate and decreased days open compared to AI at detected estrus after synchronization with GnRH, PRID and PGF2$\alpha$ or synchronization with one injection of PGF2$\alpha$.

의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구 (Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test)

  • 김형균;윤재호;최성대
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.389-394
    • /
    • 2015
  • 의료영상 검사는 정보기술 및 의료장비의 발달로 인체의 해부학적 구조를 묘사하는 능력이 날로 발전하고 있다. 그러나 상지회전이 필요한 어깨관절 의료영상 검사에서는 인체구조의 복잡성으로 정확한 자세유지가 의료영상의 진단적 가치에 매우 중요하다. 자기공명검사의 경우 긴 검사시간과 고정된 자세가 필요해 검사자의 노력과 환자의 의지만으로 재현성 있는 검사가 불가능하다. 이에 상지회전과 정량적 각도가 가능한 보조기구를 개발하여 진단적 가치가있는 의료영상 검사를 하고자하였다. 본 연구는 선행 연구의 결과를 바탕으로 보조기구를 제작하였으며, 공학용 프로그램인 CATIA 프로그램으로 3차원 모델링을 설계하여, 3D프린터로 최종 완성된 보조기구를 제작하였다. 사용된 3D 프린터는 Stratasys Objet350 Connex 모델이며, 재질은 광경화성 수지를 사용하였다. 완성된 보조기구의 크기는 $120{\times}150{\times}190mm$이며, 손잡이부의 내경은 125.9 mm 로 디자인되었다. 보조기구는 총 4개의 부품으로 바디부(외부), 손잡이부(내부), 고정단자, 연결부로 구성되었으며 바디부와 손잡이부는 원활한 회전이 가능하도록 2.1 mm의 유격이 유지되도록 하였다. 손잡이부에는 360o 눈금선을 표시하여 환자마다 관찰에 필요한 회전각도를 기록할 수 있도록 하여 추적검사나 양쪽검사에 적용할 수 있도록 하였다.

TPU 소재를 이용한 3D 프린팅 로봇 손의 제어기 설계에 관한 연구 (A Study on the Controller Design of 3D Printed Robot Hand using TPU Material)

  • 최영림;박예은;김종욱;이선희
    • 한국의류학회지
    • /
    • 제48권2호
    • /
    • pp.312-327
    • /
    • 2024
  • In this study, a rehabilitation 3D printed wearable device was developed by combining an assembly-type robot hand and an integral-type robot hand through fused deposition 3D printing manufacturing with various hardness TPU (Thermoplastic Polyurethane) filaments. The hardware configuration of the robot hand includes a controller designed with four motors, one small servo motor, and a circuit board. In the case of the assembly-type robot hand model, a 3D printed robot hand was assembled using samples printed with TPU of hardness 87A and 95A. It was observed that TPU with a hardness of 95A was suitable for use due to shape stability. For the integrated-type robot hand model, the external sample using TPU of hardness 95A could be modified through a cutting method, and the hardware configuration is the same as the assembly-type. The system structure of the 3D printed robot hand was improved from an individual control method to a simultaneous transmission method.Furthermore, the system architecture of an integrated 3D printed robotic hand rehabilitation device and the application of the rehabilitation device were developed.

전산화단층촬영검사에서 하지의 3D 혈관조영검사를 위한 새로운 고정기구의 유용성 평가 (Evaluation of Usefulness in New Immobilization Device with 3D CT Angiography for Lower Extremity)

  • 장근조;권대철
    • 한국콘텐츠학회논문지
    • /
    • 제7권4호
    • /
    • pp.184-191
    • /
    • 2007
  • 3차원 전산화단층촬영 검사에서 하지 혈관조영술을 위해서는 움직임이 없어야 한다. 표재질환의 검사는 환자의 하지가 테이블에 접촉하지 않도록 해야 한다. 새로운 고정기구를 하지 조영술을 위해 새롭게 개발 되었다. 본 연구에서는 새로운 하지조영술용 고정기구를 고안하여 개발하였다. 개발된 고정기구는 2개로 구성되었고, 폴리우레탄 레진의 재료를 이용하였다. 둔부에 위치하는 패드와 족부를 고정할 수 있도록 만들었다. 새로운 고정기구를 100명의 환자를 대상으로 전산화단층촬영영상을 획득하였으며 이들 영상을 5등급으로 구분하여 고정기구를 사용하지 않은 환자와 영상를 비교하여 평가하였다. 고정기구를 사용하여 전산화단층촬영으로 하지 혈관조영검사를 시행한 경우 매우 편안하고 움직임이 없이 혈관을 묘출하는데 효과적으로 사용됨을 확인하였다.

2단 절개 형태를 가지는 악교정 수술 장치 연구 (A Study of Orthognathic Surgical Guides with Two-stage Split Path)

  • 김민욱;박충환;노지형;정의성;박영상;김동국;서요한;우영재;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.382-389
    • /
    • 2022
  • In this study, the accuracy of the orthognathic surgical guides with single-stage split path was upgraded to realize orthognathic surgical guides with two-stage split path and simulated surgery was performed to verify its accuracy. As a result, the average error distance between the simulation model and the scan model was + 0.289 / - 0.468 mm (standard deviation 0.128), which was confirmed to be within ± 0.5 mm, which is a clinically acceptable level. Also, there was no significant difference compared with the average value of + 0.313 / - 0.456 mm (average standard deviation 0.106) of the conventional single-stage split path type device. It is judged that the use of this device can contribute to the reduction of surgical time and increase in accuracy since a separate finishing operation for bone preparation is unnecessary.

실험 계획법을 이용한 진공 차단기의 동특성 최적화 (Dynamic Responses Optimization of Vacuum Circuit Breaker Using Taghchi Method)

  • 조준연;안길영;김성태;양홍익;김규정
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권2호
    • /
    • pp.141-148
    • /
    • 2015
  • 본 연구에서는 진공 차단기(Vacuum circuit breaker)의 동적 특성을 모사하기 위해 리커다인을 이용한 다물체 동역학 해석 모델이 개발 되었다. 진공 차단기는 VI(Vacuum interrupter)를 포함한 3 개의 주회로 부와, 구동 메커니즘을 포함한 기구부로 구성된다. 이 해석적 모델의 검증을 위해, 해석 결과와 실측을 통한 실험적 결과를 비교 하였다. 일반적으로, 원활한 사고 전류 차단을 위해서는 0.9~1.1m/s 의 차단속도(Opening velocity)가 필요하다. 차단 속도의 향상을 위해, 다구찌 기법을 이용하여 진공 차단기의 설계 변수 최적화를 수행하였다. 또한 향상된 차단기의 동적 특성을 검증하기 위해, 해석 결과와 개선된 샘플의 실험적 결과를 비교 분석 하였다.

호흡보조의료기기의 사용목적 및 대상에 따른 규격적용 방안 및 성능에 관한 연구 (A Study for Application of Standard and Performance Test According to Purpose and Subject of Respiratory Medical Device)

  • 박준현;호예지;이덕희;최재순
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권5호
    • /
    • pp.215-221
    • /
    • 2019
  • The respiratory medical device is a medical device that delivers optimal oxygen or a certain amount of humidification to a patient by delivering artificial respiration to a patient through a machine when the patient has lost the ability to breathe spontaneously. These include respirators for use in chronic obstructive pulmonary disease and anesthesia or emergency situations, and positive airway pressure devices for treating sleep apnea, and as the population of COPD (chronic obstructive pulmonary disease) and elderly people worldwide surge, the market for the respiratory medical devices it is getting bigger. As the demand for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, the boundaries between the items are blurred due to the purpose, intended use, and method of use overlapping similar items in a respiratory medical device. In addition, for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, in this study, we propose clear classification criteria for the respiratory medical devices according to the purpose, intended use, and method of use and provide safety and performance evaluation guidelines for those items to help quality control of the medical devices. And to contribute to the rapid regulating and improvement of public health. This study investigated the safety and performance test methods through the principles of the respiratory medical device, national and international standards, domestic and international licensing status, and related literature surveys. The results of this study are derived from the safety and performance test items in the individual ventilator(ISO 80601-2-72), the International Standard for positive airway pressure device (ISO 80601-2-70), The safety and performance of humidifiers (ISO 80601-2-74) and the safety evaluation items related to home healthcare environment (IEC 60601-1-11), In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers and importers, certified test inspection institutions, academia, etc., the final guidelines were established through revision and supplementation. Therefore, in this study, we propose guidelines for evaluating the safety and performance of the respiratory medical device in accordance with growing technology development.

InGaAs 양자점 레이저 다이오드와 양자우물 레이저 다이오드의 특성 비교 (Comparisons of lasing characteristics of InGaAs quantum-dot and quantum well laser diodes)

  • 정경욱;김광웅;유성필;조남기;박성준;송진동;최원준;이정일;양해석
    • 한국진공학회지
    • /
    • 제16권5호
    • /
    • pp.371-376
    • /
    • 2007
  • 분자선 에피택시(molecular beam epitaxy, MBE)로 성장된 InGaAs 양자점 레이저 다이오드(quantum dot laser diode, QD-LD)와 InGaAs 양자우물 레이저 다이오드(quantum well laser diode, QW-LD)의 특성을 비교하였다. 펄스 입력전류 하에서 문턱전류밀도(threshold current density, $J_{th}$), 특성온도(characteristic temperature, $T_0$), 온도에 따른 발진파장의 변화도($d{\lambda}/dT$)를 측정한 결과, 양자우물 레이저 다이오드는 $J_{th}\;=\;322\;A/cm^2,\;T_0\;=\;55.2\;K,\;d{\lambda}/dT\;=\;0.41\;nm/^{\circ}C$로 측정되었으며, 양자점 레이저 다이오드는 $J_{th}\;=\;116\;A/cm^2,\;T_0\;=\;81.8\;K,\;d{\lambda}/dT\;=\;0.33\;nm/^{\circ}C$로 측정되었다. 양자점 레이저 다이오드는 양자우물 레이저 다이오드와 비교하였을 때, 문턱전류밀도 및 발진 광 파워가 상대적으로 우수한 결과를 보여주었다.

TCAD Based Power Semiconductor Device e-Learning Tool

  • Landowski, Matthew M.;Shen, Z. John
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.643-646
    • /
    • 2010
  • An interactive web-based teaching tool for a power semiconductor course at the University of Central Florida is presented in this paper. A novel approach is introduced using Technology Aided Design Tools (TCAD) to generate time-lapsed 2D semiconductor device cross-section embedded in a webpage using $Adobe^{(R)}$ Flash (web design tool) platform to create interactive movies that demonstrate complex device physical phenomenon. Students can step through the interactive movies forward, backward, pausing, or looping. Each step represents a giving bias condition. Current-voltage plots are represented along with the semiconductor device and a visual point is placed on the IV curve to indicate the current bias conditions. The changes are then reflected in the 2D cross-section movie area and the IV plot. This tool was implemented in a classroom setting to augment the lectures or for discovery learning.

Hydrazine Doped Graphene and Its Stability

  • Song, MinHo;Shin, Somyeong;Kim, Taekwang;Du, Hyewon;Koo, Hyungjun;Kim, Nayoung;Lee, Eunkyu;Cho, Seungmin;Seo, Sunae
    • Applied Science and Convergence Technology
    • /
    • 제23권4호
    • /
    • pp.192-199
    • /
    • 2014
  • The electronic property of graphene was investigated by hydrazine treatment. Hydrazine ($N_2H_4$) highly increases electron concentrations and up-shifts Fermi level of graphene based on significant shift of Dirac point to the negative gate voltage. We have observed contact resistance and channel length dependent mobility of graphene in the back-gated device after hydrazine monohydrate treatment and continuously monitored electrical characteristics under Nitrogen or air exposure. The contact resistance increases with hydrazine-treated and subsequent Nitrogen-exposed devices and reduces down in successive Air-exposed device to the similar level of pristine one. The channel conductance curve as a function of gate voltage in hole conduction regime keeps analogous value and shape even after Nitrogen/Air exposure specially whereas, in electron conduction regime change rate of conductance along with the level of conductance with gate voltage are decreased. Hydrazine could be utilized as the highly effective donor without degradation of mobility but the stability issue to be solved for future application.