• Title/Summary/Keyword: device management

Search Result 2,456, Processing Time 0.036 seconds

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.

A Study on the Water Quality Management of Modular Revetment Structure installed Low-Maintenance Constructed Wetland (플랜터형 호안구조물을 설치한 저관리형 습지의 수질 제어 기작에 관한 연구)

  • Ham, Eun Kyung;Choi, Yun Eui;Kim, Min;Chon, Jinhyung
    • Journal of Wetlands Research
    • /
    • v.17 no.2
    • /
    • pp.184-192
    • /
    • 2015
  • This study is a basic research for low maintenance constructed wetlands which can prevent water quality deterioration due to wetland soils. The purpose of this study is to analyze water quality control mechanisms of constructed wetland on the artificial ground which installed the modular revetment structure(MRS), a device that separates water and soil. This study was then conducted with two different wetland mesocosms (a treatment plot and a control). These mesocosms were monitored to analyze effects of water quality control of the MRS. A treatment plot was built, and separated into soil and water, by filling the MRS with the decomposed granite soil in the mesocosm made of rubber material. A control plot was built where the decomposed granite soils were exposed to water by leaving the soil on the bottom of the mesocosm made of rubber material. Water quality was then analyzed by using Kolmogorov-Smirnov Z examination which then showed that pH, BOD, SS, Chl-a, T-P, T-N had statistically valid difference between a container with the MRS and one without it. According to the analysis of the water quality, the temperature and the EC level came out similarly and both mesocosm showed same level on pH and DO. A treatment plot had higher levels of BOD, SS Chl-a, and T-P. A control plot's T-N value was little lower than that of the treatment plot. This study suggests method of constructed wetlands using the MRS prevents problems occurring in wetland soils: aridity of wetlands by soil erosion, eutrophication, and algal blooms due to nutrients released from wetland soil. These functions of constructed wetland with the MRS increase aesthetic, ecologic, social, and economic value of the wetland. Outcomes of this research will later enable more proficient way of stabilizing water quality and provide data for planning low maintenance constructed wetlands.

Blood Pressure of Healthy Newborns in the First Week of Life (분당 차병원에서 출생한 신생아 혈압치 비교)

  • Lee Jung-Sun;Park Shin-I;Park Hye-Won;Kim Se-Hyun;Hah Tae-Sun;Lee Jun-Ho
    • Childhood Kidney Diseases
    • /
    • v.9 no.1
    • /
    • pp.8-14
    • /
    • 2005
  • Purpose : This study was peformed to study normative blood pressure data in full-term neonates that may be used to facilitate Identification of neonatal hypertension.Methods : 383 newborns born in our hospital from May 2003 to January 2004 were enrolled in this study Using an oscillometric device(BP-88 NEXT, COLIN Corp.), their blood pressures were measured more than one time within a week after birth. According to each clinical variable such as sex, delivery mode, birth weight, gestational age and presence of maternal disease or perinatal problems, we divided the population into groups and calculated the mean blood pressures of each group. We compared mean blood pressures between the divided groups according to each clinical variable statistically.Results : Mean systolic and diastolic blood pressure of the Population was 70.8$\pm$ 10.9 mmHg and 43.4 $\pm$ 8.0 mmHg, respectively. There was no satistically significant difference in blood pressure according to clinical variables. Mean systolic pressure showed positive correlation with birth weight and gestational age(r=0.1420, 0.03130).Conclusion : Our results are almost in agreement with Zubrow's data from 695 newborns in U.S.A, 1995. Our data may be helpful for early detection and management of neonatal hypertension, thereby maintaining renal function ,and preventing possible complications of renal disease.

  • PDF

Development of Automatic Loading Equipment of Seedling Tray for Automatic Process of Raising Seedlings in Plant Factory (식물공장 육묘공정 자동화를 위한 육묘트레이 자동적재장치 개발)

  • Park, Sang-Min;Min, Young-Bong;Lee, Gong-In;Kim, Dong-Ouk;Kang, Dong-Hyun;Moon, Sung-Dong
    • Journal of agriculture & life science
    • /
    • v.45 no.5
    • /
    • pp.105-113
    • /
    • 2011
  • This study was carried out to develop an automatic loading equipment that can load seedling trays on loading position of the seedling bed driving on enclosed-type rail installed for interconnecting each process of raising seedlings in plant factory. The experiment of transferring the seedling tray by monorail pusher was carried out to figure out the required transfer force and problems during push type device of transporting the plastic seedling trays, that has completed its sowing process, which are installed onto the board of different materials. From the results of this experiment, the loading equipment which can exactly load three of the seedling trays orderly on the loading position of the seedling bed was designed and made. When three sowed trays on every board are transferred by pusher with the speed is at 30 cm/s, the maximum peak transfer force with maximum overshooting at initial transient state and the maximum transfer force at stead state are were respectively 32.8 N, 29.4 N on rubber board, 29.7 N, 22.5 N on a wooden board, 26.9 N, 19.6 N on a acrylic board, and 27.6 N, 19.1 N on an iron board. Changes in the transfer force occurred its maximum at the moment when the pusher collided with the tray, after the collision gradually decreased until it became stable. When two or three trays placed it in order of widthwise are transferred, it is occurred the overlapping of the tray's external bracket. The developed automatic loading equipment with PLC controller did not make any operation error through 100 times of tests, its maximum seedling tray loading speed was 2 sec/tray and its maximum error of transferred location of the tray was 0.5 cm.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

Development of Caregiver Guideline for Participation in Activities of Daily Living for the Elderly with Early Dementia: Focusing on the Delphi Survey (초기 치매 노인의 일상생활 참여 촉진을 위한 보호자 지침의 개발: 델파이 조사를 중심으로)

  • Kim, Seo-Eun;Koo, Seul-Gi;Park, Sang-M;Kim, Jung-Ran
    • 한국노년학
    • /
    • v.37 no.2
    • /
    • pp.461-474
    • /
    • 2017
  • The purpose of this study was to develop the caregiver guideline for participation in activities daily living for the elderly with early dementia in home including easily adaptable and professional strategies as early intervetion. The process of this study was 3 stage. First stage, the development of preliminary caregiver guideline as the first stage of this study was to translate to Korean and reclassify the items about caregiver guideline for participation from reports of foreign association or government related dementia, and it consisted of 3 areas, 128 statements for questionnaire for Delphi investigation. Second stage, the guideline was to conduct the content validity, and delete, reclassify, integrate, revise inappropriate items through 2 rounds and 16 Delphi panels. Third stage, the establishment of the final version of caregiver guideline. It consisted of 8 areas: home modification and assistive device, home activities of daily living, health management, communication, psycho-emotional support, leisure activities, social participation, general strategies. All 68 items was arranged in important order. The content validity, stability, agreement index in this study were 0.81, 0.15, 0.79 respectively. When content validity, stability was above 0.49, below 0.5 in Delphi survey with 15 panels, it was not required additional survey. The result of this study meaned that it was not required to additional Delphi survey, and the result was stable and agreeable. This developed guideline was useful and practical to maintain the elderly's with dementia independent and healthy life as education materials for their caregivers, so it will expect to decrease caregiver's burden. Lastly, it stated limitation and suggestion for further study.

A Study on the Improvement of Flexible Working Hours (유연근로시간제 개선에 대한 연구)

  • Kwon, Yong-man;Seo, Ei-seok
    • Journal of Venture Innovation
    • /
    • v.4 no.2
    • /
    • pp.97-108
    • /
    • 2021
  • Labor contracts appear in form as an exchange relationship between labor products and wages, but since they transcend the level of simple barter, they can be economically identified as "trading" and can be identified as "rental." From a legal point of view, a legal device that legally supports and imposes binding force on commodity exchange relations is a contract. Such a labor contract led to a relationship in which wages were received and a certain amount of time was placed under the direction and supervision of the employer as a counter benefit to the receipt of wages. Since working hours are subordinate hours with one's labor under the disposition authority of the employer, long hours of work can be done for the health and safety of workers and furthermore, it can be an act that violates the value to enjoy as a human being. The reduction of working hours needs to be shortened in terms of productivity and enjoyment of workers' culture so that they can expand and reproduce, but users' corporate management labor and production activities should also be compatible compared to those pursued by capitalist countries. Working hours can be seen as individual time and time in society as a whole, and long hours of work at the individual level are reduced, which is undesirable at the individual level, but an increase in products due to an increase in production time at the social level can help social development. It is necessary to consider working hours in terms of finding the balance between these individual and social levels. If the regulation method of working hours was to regulate the total amount of working hours, flexibility and elasticity of working hours are a qualitative regulation method that allows companies to flexibly allocate and organize working hours within a certain range of up to 52 hours per week. Accordingly, it is necessary to shorten working hours, but expand and implement the flexible working hours system according to the situation of the company. To this end, it is necessary to flexibly operate the flexible working hours system, which is currently limited to six months, handle the selective working hours by agreement between employers and workers, and expand the target work of discretionary working hours according to the development of information and communication technology and new types based on the 4th industrial revolution.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Development of a complex failure prediction system using Hierarchical Attention Network (Hierarchical Attention Network를 이용한 복합 장애 발생 예측 시스템 개발)

  • Park, Youngchan;An, Sangjun;Kim, Mintae;Kim, Wooju
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.4
    • /
    • pp.127-148
    • /
    • 2020
  • The data center is a physical environment facility for accommodating computer systems and related components, and is an essential foundation technology for next-generation core industries such as big data, smart factories, wearables, and smart homes. In particular, with the growth of cloud computing, the proportional expansion of the data center infrastructure is inevitable. Monitoring the health of these data center facilities is a way to maintain and manage the system and prevent failure. If a failure occurs in some elements of the facility, it may affect not only the relevant equipment but also other connected equipment, and may cause enormous damage. In particular, IT facilities are irregular due to interdependence and it is difficult to know the cause. In the previous study predicting failure in data center, failure was predicted by looking at a single server as a single state without assuming that the devices were mixed. Therefore, in this study, data center failures were classified into failures occurring inside the server (Outage A) and failures occurring outside the server (Outage B), and focused on analyzing complex failures occurring within the server. Server external failures include power, cooling, user errors, etc. Since such failures can be prevented in the early stages of data center facility construction, various solutions are being developed. On the other hand, the cause of the failure occurring in the server is difficult to determine, and adequate prevention has not yet been achieved. In particular, this is the reason why server failures do not occur singularly, cause other server failures, or receive something that causes failures from other servers. In other words, while the existing studies assumed that it was a single server that did not affect the servers and analyzed the failure, in this study, the failure occurred on the assumption that it had an effect between servers. In order to define the complex failure situation in the data center, failure history data for each equipment existing in the data center was used. There are four major failures considered in this study: Network Node Down, Server Down, Windows Activation Services Down, and Database Management System Service Down. The failures that occur for each device are sorted in chronological order, and when a failure occurs in a specific equipment, if a failure occurs in a specific equipment within 5 minutes from the time of occurrence, it is defined that the failure occurs simultaneously. After configuring the sequence for the devices that have failed at the same time, 5 devices that frequently occur simultaneously within the configured sequence were selected, and the case where the selected devices failed at the same time was confirmed through visualization. Since the server resource information collected for failure analysis is in units of time series and has flow, we used Long Short-term Memory (LSTM), a deep learning algorithm that can predict the next state through the previous state. In addition, unlike a single server, the Hierarchical Attention Network deep learning model structure was used in consideration of the fact that the level of multiple failures for each server is different. This algorithm is a method of increasing the prediction accuracy by giving weight to the server as the impact on the failure increases. The study began with defining the type of failure and selecting the analysis target. In the first experiment, the same collected data was assumed as a single server state and a multiple server state, and compared and analyzed. The second experiment improved the prediction accuracy in the case of a complex server by optimizing each server threshold. In the first experiment, which assumed each of a single server and multiple servers, in the case of a single server, it was predicted that three of the five servers did not have a failure even though the actual failure occurred. However, assuming multiple servers, all five servers were predicted to have failed. As a result of the experiment, the hypothesis that there is an effect between servers is proven. As a result of this study, it was confirmed that the prediction performance was superior when the multiple servers were assumed than when the single server was assumed. In particular, applying the Hierarchical Attention Network algorithm, assuming that the effects of each server will be different, played a role in improving the analysis effect. In addition, by applying a different threshold for each server, the prediction accuracy could be improved. This study showed that failures that are difficult to determine the cause can be predicted through historical data, and a model that can predict failures occurring in servers in data centers is presented. It is expected that the occurrence of disability can be prevented in advance using the results of this study.

Initial Experience of the Emergency Bypass System ($EBS^{(R)}$) for the Patients with Cardiogenic Shock due to an Acute Myocardial Infarction (급성 심근경색으로 인한 심인성 쇼크 환자에 대한 경피적 순환 보조장치($EBS^{(R)}$) 적용의 초기경험)

  • Ryu, Kyoung-Min;Kim, Sam-Hyun;Seo, Pil-Won;Ryu, Jae-Wook;Kim, Seok-Kon;Kim, Young-Hwa;Park, Seong-Sik
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.329-334
    • /
    • 2008
  • Background: Percutaneous cardiopulmonary support. (PCPS) has the potential to rescue patients in cardiogenic shock who might otherwise die. PCPS has been a therapeutic option in a variety of the clinical settings such as for patients with myocardial Infarction, high-risk coronary intervention and postcardiotomy cardiogenic shock, and the PCPS device is easy to install. We report our early experience with PCPS as a life saving procedure in cardiogenic shock patients due to acute myocardial infarction. Material and Method: From January 2005 to December 2006, eight patients in cardiogenic shock with acute myocardial infarction underwent PCPS using the CAPIOX emergency bypass system($EBS^{(R)}$, Terumo, Tokyo, Japan). Uptake cannulae were inserted deep into the femoral vein up to the right atrium and return cannulae were inserted into the femoral artery with Seldinger techniques using 20 and 16-French cannulae, respectively. Simultaneously, autopriming was performed at the $EBS^{(R)}$ circuit. The $EBS^{(R)}$ flow rate was maintained between $2.5{\sim}3.0L/min/m^2$ and anticoagulation was performed using intravenous heparin with an ACT level above 200 seconds. Result: The mean age of patients was $61.1{\pm}14.2$ years (range, 39 to 77 years). Three patients were under control of the $EBS^{(R)}$ before percutaneous coronary intervention (PCI), three patients were under control of the $EBS^{(R)}$ during PCI, one patient was under control of the $EBS^{(R)}$ after PCI, and one patient was under control of the $EBS^{(R)}$ after coronary bypass surgery. The mean support time was $47.5{\pm}27.9$ hours (range, 8 to 76 hours). Five patients (62.5%) could be weaned from the $EBS^{(R)}$ after $53.6{\pm}27.2$ hours. (range, 12 to 68 hours) of support. All of the patients who could successfully be weaned from support were discharged from the hospital. There were three complications: one case of gastrointestinal bleeding and two cases of acute renal failure. Two of the three mortality cases were under cardiac arrest before $EBS^{(R)}$ support, and one patient had an intractable ventricular arrhythmia during the support. All of the discharged patients are still surviving at $16.8{\pm}3.1$ months (range, 12 to 20 months) of follow-up. Conclusion: The use of $EBS^{(R)}$ for cardiogenic shock caused by an acute myocardial infarction could rescue patients who might otherwise have died. Successfully recovered patients after $EBS^{(R)}$ treatment have survived without severe complications. More experience and additional clinical investigations are necessary to elucidate the proper installation timing and management protocol of the $EBS^{(R)}$ in the future.