• Title/Summary/Keyword: device development

Search Result 5,566, Processing Time 0.033 seconds

A Near Range Sensing Device Using Active Laser Diodes (능동레이저 근거리 감지센서)

  • Kim, Ung-Sik;Kang, Byoung-Moo;Kim, Wan-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2336-2338
    • /
    • 1998
  • This paper describes an active laser sensing device using laser diodes and optic devices. It is able to detect near targets existed in $360^{\circ}$ directions simultaneously with effectiveness and reliability. This sensing device consists of four laser transmitters and four receivers. Only four transmitter/receiver channels of this near range sensing device are capable of $360^{\circ}$ coverage. The usefulness of this sensing device is confirmed through some experiments for the mock-up targets.

  • PDF

Software Risk Management and Cyber Security for Development of Integrated System Remotely Monitoring and Controlling Ventilators (인공호흡기 원격 통합 모니터링 및 제어 시스템 개발을 위한 소프트웨어 위험관리 및 사이버보안)

  • Ji-Yong Chung;You Rim Kim;Wonseuk Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.99-108
    • /
    • 2023
  • According to the COVID-19, development of various medical software based on IoT(Internet of Things) was accelerated. Especially, interest in a central software system that can remotely monitor and control ventilators is increasing to solve problems related to the continuous increase in severe COVID-19 patients. Since medical device software is closely related to human life, this study aims to develop central monitoring system that can remotely monitor and control multiple ventilators in compliance with medical device software development standards and to verify performance of system. In addition, to ensure the safety and reliability of this central monitoring system, this study also specifies risk management requirements that can identify hazardous situations and evaluate potential hazards and confirms the implementation of cybersecurity to protect against potential cyber threats, which can have serious consequences for patient safety. As a result, we obtained medical device software manufacturing certificates from MFDS(Ministry of Food and Drug Safety) through technical documents about performance verification, risk management and cybersecurity application.

Performance Analysis of a Flow Passage Opening Device through Low Speed Aircraft Captive Flight Tests

  • Jung, Sung-Min;Park, Jeong-Bae
    • International Journal of Aerospace System Engineering
    • /
    • v.4 no.2
    • /
    • pp.5-9
    • /
    • 2017
  • In a pressurized fuel supply system of aircraft, a flow passage opening device is required to keep fuel continuously transferred from one tank to the other. The device utilizes balancing weights in order to follow up an acceleration at special conditions such as negative g. It is very difficult to test the device in a real high-speed and high-altitude test since severe test conditions and expensive supports are needed. Therefore, this paper deals with performance analysis of a flow passage opening device through low speed aircraft captive flight tests (CFT) including roll and negative-g maneuvers. It is shown that balancing weights in the device can open the passage in accordance with fuel position.

Development of Component of Micro Thermal Device in KAIST (KAIST의 마이크로 열기관 요소 기술 개발)

  • Lee, Dae Hoon;Park, Dae-Eun;Yoon, Euisil;Kwon, Sejin
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.482-485
    • /
    • 2002
  • Development projects in KAIST rotted to the micro thermal device is introduced. Multi disciplinary research team is composed by combustion group and semiconductor group in KAIST and catalyst research center in KRICT to develop micro thermal/fluidic device and various items are on development. Among the projects, various kind of componenst that is required by the micro thermal devicesystem is introduced. Technology related to development of micro combustor, Micro igniter, micro fabrication of 3D structure, micro reactor and micro catalyst preparation is introduced.

  • PDF

A Study on the Development and Effectiveness of ISO13485:2016 Education Programs for Domestic Medical Device Manufacturers (국내 의료기기 제조업체의 ISO13485:2016 교육 프로그램 개발 및 교육 효과 연구)

  • Lee, Seul-Bi;Kang, Giho;Jang, Wonseuk;Kwon, Byeong-Ju
    • Journal of Korean Society for Quality Management
    • /
    • v.50 no.3
    • /
    • pp.503-515
    • /
    • 2022
  • Purpose: As ISO 13485 was revised in 2016, the domestic GMP (Good Manufacturing Practice) system was also revised and implemented in 2019. However, there are many problems in the domestic medical device industry because most of the small and medium-sized enterprises lack human and material resources. Accordingly, this study was conducted to provide education programs for domestic medical device companies to induce information provision and improve the company's quality management ability. Methods: First, analyze existing education. Second, based on the revised GMP system, a survey paper was produced to investigate difficulties and problems experienced by companies. Third, a two-week survey was conducted on domestic medical device manufacturers, and a total of 77 companies responded to this survey. Fourth, educational program development was conducted based on the results of the survey. Results and Conclusion: The developed education program consists of a total of five sessions. In this study, the educational program developed by grasping the needs of the company through a survey consists of a total of five sessions. The first session consisted of theoretical education and the second to fifth sessions of practical education. Through the education program developed in this study, it is expected to contribute to the overall development of medical device quality by establishing a domestic medical device manufacturing environment that secures the safety and performance of domestic medical device companies.

Development of an IoT Device for Detecting Escherichia coli from Various Agri-Foods and Production Environments (IoT 적용 대장균 검출기 개발과 농식품 및 생산환경에 적용)

  • Nguyen, Bao Hung;Chu, Hyeonjin;Kim, Won-Il;Hwang, Injun;Kim, Hyun-Ju;Kim, Hwangyong;Ryu, Kyoungyul;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.542-550
    • /
    • 2019
  • To detect Escherichia coli from agri-food and production environments, a device based on IoT (internet of things) technology that can check test results in real time on a mobile phone has been developed. The efficiency of the developed device, which combines an incubator equipped with a UV lamp, a high-resolution camera and software to detect E. coli in the field, was evaluated by measuring the device's temperature, detection limit, and detection time. The device showed a difference between its programmed temperature setting and actual temperature of about 1.0℃. In a detection limit test performed with a single-colony inoculation, a color change to yellow and a florescent signal were detected after 12 and 15 h incubations, respectively. The incubation time also decreased along with increasing bacteria levels. When applying the developed method and device to various samples, including utensils, gloves, irrigation water, seeds, and vegetables, detection rates of E. coli using the device were higher than those of the Korean Food Code method. These results show that the developed protocol and device can efficiently detect E. coli from agri-food production environments and vegetables.

Development of Brain Tumor Detection using Improved Clustering Method on MRI-compatible Robotic Assisted Surgery (MRI 영상 유도 수술 로봇을 위한 개선된 군집 분석 방법을 이용한 뇌종양 영역 검출 개발)

  • Kim, DaeGwan;Cha, KyoungRae;Seung, SungMin;Jeong, Semi;Choi, JongKyun;Roh, JiHyoung;Park, ChungHwan;Song, Tae-Ha
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.3
    • /
    • pp.105-115
    • /
    • 2019
  • Brain tumor surgery may be difficult, but it is also incredibly important. The technological improvements for traditional brain tumor surgeries have always been a focus to improve the precision of surgery and release the potential of the technology in this important area of the body. The need for precision during brain tumor surgery has led to an increase in Robotic-assisted surgeries (RAS). One of the challenges to the widespread acceptance of RAS in the neurosurgery is to recognize invisible tumor accurately. Therefore, it is important to detect brain tumor size and location because surgeon tries to remove as much tumor as possible. In this paper, we proposed brain tumor detection procedures for MRI (Magnetic Resonance Imaging) system. A method of automatic brain tumor detection is needed to accurately target the location of the lesion during brain tumor surgery and to report the location and size of the lesion. In the qualitative assessment, the proposed method showed better results than those obtained with other brain tumor detection methods. Comparisons among all assessment criteria indicated that the proposed method was significantly superior to the threshold method with respect to all assessment criteria. The proposed method was effective for detecting brain tumor.

Improved Performance of Organic Light-Emitting Diodes Using Novel Hole-transporting Materials

  • Kim, Young-Kook;Hwang, Seok-Hwan;Kwak, Yoon-Hyun;Lee, Chang-Ho;Yi, Jeoung-In;Lee, Jong-Hyuk;Kim, Sung-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.758-761
    • /
    • 2009
  • The electroluminescent devices with the phenylnaphthyldiamine HTMs as the hole-transporting layer were more efficient than that with the biphenyldiamine HTM 1. Particularly, the life-time of the device IV using HTM 2 is about two times longer than that of the reference device III with HTM 1 within the measured current density, indicating more effective recombination at the emitting layer of device IV.

  • PDF

Development of Service Use Cases and Business Models for 4G Mobile Communications Based on Device-to-Device Communications (단말기간 직접통신(Device-to-Device) 기반 4G 이동통신 서비스 발굴 및 비즈니스 모델 개발 방법론)

  • Oh, Seul-Ki;Ryu, Seung-Wan;Park, Sei-Kwon;Shin, Dong-Cheon;Kim, Yi-Kang
    • Journal of Information Technology Services
    • /
    • v.11 no.2
    • /
    • pp.339-353
    • /
    • 2012
  • Mobile communication technology is advancing forward to deliver more connected devices and richer content and applications. The number of subscriptions continues to grow along with an explosive increase in the mobile data traffic demand. Thereby, it creates a significant network capacity shortage concerns for mobile network operators. In order to address this problem, it is essential to increase the network capacity at a low additional cost. The device-to-device (D2D) communication based proximity service is believed to have a promising future mobile communication technology that is capable to create new mobile service opportunities and offload traffic to the eNB. In addition, it is also required to develop new mobile communication services and its business models not only to accommodate the increasing mobile traffic demand but also to foster profitability of mobile business service providers such as the network providers, contents providers and platform providers. In this article, we first analyze current mobile business eco-system in the context of CPNT based value chain. Then, propose service development framework and business model creation methodologies for the device-to-device communication based services in the beyond LTE/LTE-Advanced systems.

Proposal for guided missile actuator device inspection using data acquisition device (데이터 수집 장치를 이용한 유도탄 구동장치 점검 제안)

  • Eui-Jae Jung;Tack-Keun Oh;Jung-Min Lee;Pil-joong Yoo
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.4
    • /
    • pp.423-428
    • /
    • 2023
  • In the missile actuator system, the time and position of the wings of the drive device are very important factors in the initial maneuver of the missile, and therefore, the missile actuator device must be inspected while ensuring the accuracy and real-time of motion collection data of the actuator. In this study, the difference between the design and implementation method for checking the existing actuator device and the design implementation method of the actuator device through the DAQ(Data Acquisition) device is compared, and the difference in data collection amount and real-time data collection performance is compared and tested, and the data shown through actual tests are compared. is converted into a graph, the actuator waveform is compared and analyzed, and based on the analyzed data, DAQ device inspection configuration that guarantees real-time response speed and stability during inspection of existing actuators and DAQ devices is proposed.