• Title/Summary/Keyword: device control

Search Result 5,526, Processing Time 0.047 seconds

Dynamics and die design in continuous and patch slot coating processes (Continuous 와 pattern slot 코팅 공정에서의 유동특성과 다이 설계)

  • Kim Su-Yeon;Shim Seo-Hoon;Shin Dong-Myeong;Lee Joo-Sung;Jung Hyun-Wook;Hyun Jae-Chun
    • Proceedings of the Korean Society of Rheology Conference
    • /
    • 2006.06a
    • /
    • pp.81-84
    • /
    • 2006
  • Slot coating process, in continuous and patch modes, has been applied for the many precise coating products, e.g., flat panel displays and second batteries. However, manufacturing uniform coating products is not a trivial task at high-speed operations because various flow instabilities or defects such as leaking, bubbles, ribbing, and rivulets are frequently observed in this process. It is no wonder, therefore, that many efforts to understand the various aspects of dynamics and coating windows of this process have been made both in academia and industry. In this study, as the first topic, flow dynamics within the coating bead in slot coating process has been investigated using the one-dimensional viscocapillary model by lubrication approximation and two-dimensional model by Flow-3D software. Especially, operability windows in both 1D and 2D cases with various slot die lip designs have been successfully portrayed. Also, effects of process conditions like viscosity and coating gap size on slot coating window have been analyzed. Also, some experiments to find minimum coating thickness and coating windows have been conducted using slot die coater implemented with flow visualization device, corroborating the numerical results. As the second topic, flow dynamics of both Newtonian and Non-Newtonian fluids in patch or pattern slot coating process, which is employed in manufacturing IT products such as secondary batteries, has been investigated for the purpose of optimal process designs. As a matter of fact, the flow control in this system is more difficult than in continuous case because od its transient or time-dependent nature. The internal die and die lip designs for patterned uniform coating products have been obtained by controlling flow behaviors of coating liquids issuing from slot. Numerical simulations have been performed using Fluent and Flow-3D packages. Flow behavior and pressure distribution inside the slot die has been compared with various die internal shapes and geometries. In the coating bead region, efforts to reduce irregular coating defects in head and tail parts of one patterned coating unit have been tried by changing die lip shapes. It has been concluded that optimal die internal design gas been developed, guaranteeing uniform velocity distribution of both Newtonian and shear thinning fluids at the die exit. And also optimal die lip design has been established, providing the longer uniform coating layer thickness within one coating unit.

  • PDF

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.

Hypothermia Effect on Apoptotic Neuronal Death in Traumatic Brain Injury Model

  • Yoo, Do-Sung;Lee, Soon-Kyu;Huh, Pil-Woo;Han, Young-Min;Rha, Hyung-Kyun;Kim, Dal-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.3
    • /
    • pp.215-220
    • /
    • 2005
  • Objective : Many researchers believe that the hypothermia shows neuro-protective effect on brain injury. To understand the molecular mechanism of the hypothermic treatment, this study investigated its effects on the expression of cell death or survival related proteins such as p53, Bcl-2 and Bax in the rat traumatic brain injury[TBI] model. Methods : Twenty rats [Spraque Dawley, $200{\sim}250g$] were subjected to the brain injury of moderate severity [$2.4{\sim}2.6atm$] using the fluid percussion injury device and five rats were received only same surgery as controls. During 30minutes after the brain injury, the hypothermia group was maintained the body temperature around $34^{\circ}C$ while the control group were maintained that of $36^{\circ}C$. Five rats in each group were sacrificed 12h or 24h after brain injury and their brain sections was analyzed for physical damages by H-E stains and the extent of apoptosis by TUNEL assay and immunohistochemical stains. The tissue damage after TBI was mainly observed in the ipsilateral cortex and partly in the hippocampus. Results : Apoptosis was observed by TUNEL assay and the Bax protein was detected in both sample which harvested 12h and 24h after TBI. In the hypothermia treatment group, tissue damage and apoptosis were reduced in HE stains and TUNEL assay. In hypothermia treatment group rat shows more expression of the Bcl-2 protein and shows less expression of the Bax protein, at both 12h and 24h after TBI. Conclusion : These results show that the hypothermia treatment is an effective treatment after TBI, by reducing the apoptotic process. Therefore, it could be suggested that hypothermia has a high therapeutic value for treating tissue damages after TBI.

Development of component architecture to support IoT management (IoT 및 네트워크 관리 지원을 위한 컴포넌트 아키텍처 개발)

  • Seo, Hee Kyoung
    • Smart Media Journal
    • /
    • v.6 no.2
    • /
    • pp.42-49
    • /
    • 2017
  • It is important to realize automation services by communicating in IoT with humans, objects & objects, and forming a common network. People used web like the most powerful network way to sharing things and communication. Therefore the efficiency method communication between each device and the web in IoT could be different from ones. The best method for high quality software product in web applications is software reuse ; Modules, classes, patterns, frameworks, and business components are reusable elements of various perspectives. Components is plugged with others through well-defined interfaces, which can overcome the operation and complexity of application development. A web-based distributed environment for IoT applications is a standard architecture use information collected from various devices for developing and using applications. For that reason, the network management which manages the constituent resources for the best service control in IoT application is required as a sub-layer support service in most applications as well as individual applications. In this paper, we measure to develop a network management system based not only by components but on heterogeneous internetworks. For procedure this, we clarify a component architecture for classifying and classify also the component needed in the IOT and network domain or order the type of real network management system.

Design of Indoor Electric Moving and Lifting Wheelchair with Minimum Rotation Radius and Obstacle Overcoming (최소 회전반경 및 장애물 극복형 실내 전동 이·승강 휠체어의 설계)

  • Kim, Young-Pil;Ham, Hun-Ju;Hong, Sung-Hee;Ko, Seok-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.415-424
    • /
    • 2019
  • In this paper, a minimum rotation radius was designed and fabricated to overcome the threshold so that elderly or disabled people who have difficulty moving can move and transfer safely and conveniently in a narrow room. In the indoor environment, where the sedentary culture develops, this study aimed to provide convenience for passengers with fracture diseases, geriatric diseases, and other knee and waist diseases. First, links, seats, armrests, covers, motors, batteries, chargers, controllers, etc. were attached to the frame so that they could be moved and lifted indoors. The product design and structure were designed considering the user's environment and physical characteristics, and IoT functions were added. A driving experiment was performed to confirm the operating performance of the manufactured indoor moving and lifting wheelchair. The performance tests, such as continuous running time, turning radius, maximum actuator load, maximum lift height, sound pressure level, minimum sensing distance of the driving aid sensor, interworking of server and app programs, device compatibility, and duty cycle error rate, were performed. As a result of the test, the built-in wheelchair could achieve the performance test target of each item and operate successfully.

A CFD Study of Oil Spill Velocity from Hole in the Hull of Oil Tanker (유조선 선체 파공에 따른 원유 유출 유속의 CFD 연구)

  • Choi, Dooyoung;Lee, Jungseop;Paik, Joongcheol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.71-71
    • /
    • 2018
  • Sea pollution accidents have been occurred due to the increase of marine ship traffic. Oil spill from the hull hole induced by tanker collision results in the huge sea pollution. Proper and prompt reaction on such oil spill disaster is needed to minimize the damage. Thru-hull emergency wood plug is typically used to manually close small holes, while it is required to develop some mechanical devices for closing large holes in the hull due to huge fluid pressure. Accurate estimation of oil discharge and velocity from such holes are important to develop proper device to control hull hole damage. High resolution CFD modeling investigation on the configurations of hull hole of 7.5 m initial depth and 30 cm diameter, which was observed in the oil spill accident of the Hebei Sprit off the west coast of Korea in 2007, has been carried out to compute the oil spill velocity distribution in terms of flow depth. Friction loss due to the viscous flow and the discharge coefficient of crude oil with specific gravity SG = 0.85 and viscosity of $4-12cP(mPa{\cdot}s)$ at the temperature of $20^{\circ}C-100^{\circ}C$ are presented in terms of Reynolds number based on the results of high-resolution CFD modeling.

  • PDF

Adaptive Filter Design for Eliminating Baseline Wandering Noise of Electrocardiogram (심전도 기저선 흔들림 잡음 제거를 위한 적응형 필터 설계)

  • Choi, Chul-Hyung;Rahman, MD Saifur;Kim, Si-Kyung;Park, In-Deok;Kim, Young-Pil
    • The Journal of Korean Institute of Information Technology
    • /
    • v.15 no.12
    • /
    • pp.157-164
    • /
    • 2017
  • Mobile ECG signal measurement is a technique to measure small signals of several mV, and many studies have been conducted to remove noise including wandering scheme. Removal of the equipotential line noise caused by shaking or movement of the electrode cable is one of the core research contents for the electrocardiogram measurement. In this study, we proposed a modified step-size of combined NLMS(normalized least squares) and DLMS(delayed least squares) adaptive filter to eliminate baseline noise from ECG signals. The proposed method mainly adjusts initial filter step-size to reduce distortion of original ECG signals characteristic after eliminating baseline noise. The modified filter step-size is scaled by filter order size and distortion minimization factor. This method is suitable for portable ECG device with a small processor and less power consumption. This technique also decreases computation time which is essential for real-time filtering. The proposed filter also increase the signal to noise ratio (SNR) compared to conventional NLMS filter.

Study on Influence Analysis of Radioactive Terror Scenarios by Weather Conditions (기상조건에 따른 방사능테러 시나리오 영향 분석)

  • Kim, Tae Woo;Jeon, Yeo Ryeong;Chang, Sunyoung;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.719-725
    • /
    • 2018
  • After 9/11 attacks in the U.S, Terrorism has increased the number of unspecified casualties through multi-use facility terror attacks compared to the past. The subsequent London bombings and the self-destruction of Pakistan increased people's fear and social anxiety. As international events have been held in Korea recently, awareness and concern over radioactive terrorism and security management of radioactive materials are increasing. In this paper, we compared the results of different meteorological conditions using HotSpot Code. After creating a possible terror scenario in Korea, sources likely to be use in RDD and Dirty bomb were investigated. The meteorological condition was selected by comparing the Pasquill-Gifford stability class with the most stable condition F and the most unstable condition A. The result value of the A and F condition through simulation were shown not to cause citizens to die from acute effects due to radiological effects. The range of radioactivity is different according to the wind speed and the meteorological stability, and the degree of radioactivity dilution is different according to meteorological conditions. Analysis results are expected to be used for initial response in the event of a radioactive terrorist attack.

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Transportation and City Gas: Design and Operation Guideline (고품질화 바이오가스 이용 기술지침 마련을 위한 연구(III): 도시가스 및 수송용 - 기술지침(안) 중심으로)

  • Moon, HeeSung;Kwon, Junhwa;Park, Hoyeon;Jeon, Taewan;Shin, Sunkyung;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.67-73
    • /
    • 2019
  • In this study, to optimize the production and utilization of biogas for organic waste resources, the precision monitoring of on-site facilities and the energy balance by facility were analyzed, and the solutions for field problems were investigated, and the design and operation guidelines for pretreatment facilities and generators were presented. Gas pre-treatment is required to solve frequent failures and efficiency degradation in operation of high quality refining facilities, and processing processes such as desulfurization, dehumidification, deoxidization, dust treatment, volatile organic compounds, etc. Since these processes are substances that are also eliminated from the high-quality process, quantitative guidelines are not presented in the gas pretreatment process, but are suggested to operate during the processing process as a qualitative guideline. In particular, dust, siloxane, and volatile organic compounds are the main cause of frequent failure of high-quality processes if they are not removed from the gas pretreatment process. Design of the biogas high-quality process. The operation guidelines provide quality standards [Methane content (including propane) of 95% or more] with 90% or more utilization of the total gas generation, two systems, and a margin of 10% or more. It also proposed installing gas equalization tank, installing thermal automatic control system for controlling equalization of auxiliary fuel, installing dehumidification device at the back of high quality for removing moisture generated in the process of gas compression, installing heat-resisting facilities to prevent freezing of facilities in winter and reducing efficiency, and installing membrane facilities in particular.

Professional Certification of Medical Technologists in Korea, Japan, and United States of America (한국, 일본, 미국 임상병리사 전문자격)

  • Koo, Bon-Kyeong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.1-14
    • /
    • 2019
  • The names of medical technologist in Korea, Japan, and the United State of America vary depending on the medical system, educational system, and work areas. Conventionally, jobs equal or similar to medical technologist (commonly known as clinical laboratory technologist, medical laboratory technologist, clinical laboratory scientist, and medical laboratory scientist), histotechnologist, cytotechnologist, and genetic technologist. Jobs, such as extracorporeal technologist, medical electrophysiology technologist, and medical sonographer, allow other allied health professionals including medical technologists, to obtain their qualification. The work areas of medical technologists are classified into clinical pathologic technology, pathologic technology, clinical genetics technology, nuclear medicine in vitro technology, and clinical physiologic technology. New titles of Korean specialized medical technologists refer to certification systems, such as CLMJ, CMAJ, ASCP, IAC, ABRET, and ARMDS. Currently, there are eight types of specialized medical technologists under the cooperation of specialized academic societies. They are hematology, transfusionology, chemistry, immunology, microbiology, histology, cytology, nuclear medicine. It can be further divided into 20 categories according to the work areas such as mass spectrometry, infection control, Pathologists' Assistant, flow cytometry, HLA, cytogenetics, molecular genetics, cardiopulmonary physiology, neurophysiology (EEG/EMG/PSG/etc.), cardiac sonography, neurosonography (TCD/carotid), and medical device quality manager.