• 제목/요약/키워드: deviation of position

검색결과 521건 처리시간 0.024초

성인여성용 브래지어원형 개발 연구(제1보) -75A 치수를 중심으로- (A Study on the Development of Basic Brassiere Pattern for Adult Women -focusing on size 75A-)

  • 박은미;손희순
    • 한국의류학회지
    • /
    • 제25권4호
    • /
    • pp.719-730
    • /
    • 2001
  • The purpose of this study is to develop the basic patterns of adult womens brassiere therewith, provide for some basic data useful to the brassiere manufacturing which are both functional and fitting. For this purpose, 220 adults women(aged between 20 and 59) were sampled to be measured for their body sizes and tested for their brassiere wearing. The collected data were statistically processed using the SAS 6.12 for Means, Standard Deviation, etc. The results of this study can be summarized as follows; 1. In order to develop the basic patterns of adult womens brassieres, 75A size was selected out of 12 size combination(3 women per 75A size) and then, their brassiere fitting was tested. As a result, the fronts of the basic patterns were found to have such problems as undone front center, poor levelling of upper cups bottom line or lower cups top line, poor shape of upper cups outside top line and shoulder strip position. On the other hand, n the rear side of the basic patterns, the central part of the wing was slightly lifted, while the wing width and straps interval did not befit the full-cup brassiere. The result of this first brassiere fitting test showed that the functionality and aesthetics of the basic pattern brassieres were more or less satisfactory, and thus, the problems were address for the second test. In the second test, the aesthetics, breast-shaping effect and functionality of the basic pattern brassieres were much improved. 2. The basic patterns of adult womens brassieres were characterized by a round cup wired as well as a full cup embracing the entire breasts. Each basic pattern which consisted of upper and lower cups was shaped \"straight(-)\". The basic sizes adopted at the first design stage (see fig. 1-2) was 75A of which was designed as upper foundation basic pattern. At the second stage, the upper body foundation pattern were used to design lower cup, upper cup, front panel and wing in their order.(see fig. 3-5, fig. 8)5, fig. 8)

  • PDF

Determination of In-Vivo Glenohumeral Translation During Loaded and Unloaded Arm Elevation

  • Nishinaka, Naoya;Mihara, Kenichi;Suzuki, Kazuhide;Makiuchi, Daisuke;Matsuhisa, Takayuki;Tsutsui, Hiroaki;Kon, Yoshiaki;Banks, Scott A.
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2009년도 제17차 학술대회
    • /
    • pp.44-44
    • /
    • 2009
  • The purpose of this study was to investigate humeral translation relative to the glenoid invivo during loaded and unloaded shoulder abduction. CT scans of 9 healthy shoulders were acquired and 3D models were created. The subject was positioned in front of a fluoroscope and motions were recorded during active abduction. The subjects performed two trials of holding a 3kg weight and unload. 3D motions were determined using model-based 3D-to-2D registration to obtain 6 degrees of freedom kinematics. Glenohumeral translation was determined by finding the location on the humeral head with the smallest separation from the glenoid. Humeral translation was referenced to the glenoid center in the superior/inferior direction. The humerus moved an average of 2 mm, from inferior to central on the glenoid, during arm abduction for both conditions. The humeral head was centered within 1mm from the glenoid center above $70^{\circ}$. There were no statistically significant differences for both conditions. The standard deviation decreased gradually over the motion, with significantly lower variability at the end of abduction compared to the initial unloaded position. We assumed that the humeral translation to the center of the glenoid provides maximum joint congruency for optimal shoulder function and joint longevity. We believe this information will lead to better strategies to prevent shoulder injuries, enhance rehabilitation, and improve surgical treatments.

  • PDF

Proton Beam Dosimetry Intercomparison

  • Fukumura, Akifumi;Kanai, Tatsuaki;Kanematsu, Nobuyuki;Yusa, Ken;Maruhashi, Akira;Nohtomi, Akihiro;Nishio, Teiji;Shimbo, Munefumi;Akagi, Takashi;Yanou, Toshihiro;Fukuda, Shigekazu;Hasegawa, Takashi;Kusano, Yohsuke;Masuda, Yasutaka
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.252-254
    • /
    • 2002
  • A new protocol for dosimetry in external beam radiotherapy is published by the Japan Society of Medical Physics (JSMP) in 2002. The protocol deals with proton and heavy ion beams as well as photon and electron beams, in accordance with IAEA Technical Report Series No. 398. To establish inter-institutional uniformity in proton beam dosimetry, an intercomparison program was carried out with the new protocol. The absorbed doses are measured with different cylindrical ionization chambers in a water phantom at a position of 30-mm residual range for a proton beam, that had range of 155 mm and a spread out Bragg peak (SOBP) of 60-mm width. As a result, the intercomparison showed that the use of the new protocol would improve the +/- 1.0 % (one standard deviation) and 2.7 % (maximum discrepancy) differences in absorbed doses stated by the participating institutions to +/- 0.3% and 0.9 %, respectively. The new protocol will be adopted by all of the participants.

  • PDF

정상인에서 요천추 코르셋 착용이 엉덩관절을 펼 때 배곧은근과 엉덩관절 폄근의 수축 개시시간에 미치는 영향 (The Effect of a Lumbosacral Corset on the Onset of Rectus Abdominis and Hip Extensor Activity During Hip Extension in Healthy Subjects)

  • 박철홍;권오윤;조상현
    • 한국전문물리치료학회지
    • /
    • 제9권3호
    • /
    • pp.23-37
    • /
    • 2002
  • This study examined the muscle recruitment order during extension of the hip joint in normal subjects, and evaluated whether the external support obtained from wearing a lumbosacral corset had an effect on muscle recruitment leading to increased lumbar stability. The subjects were 40 normal adults (32 male, 8 female) with no history of low back pain and no pathological findings in the nervous or musculoskeletal systems. All subjects extended their hip joints under 3 positions (prone, sidelying, standing). During extension, the onsets of contraction of the rectus abdominis, gluteus maximus, and semitendinosus muscles were measured. Electromyographic activity was measured using a surface electrode, and the muscle contraction onset time was designated as the point exceeding a threshold of 25 ms, using a mean plus twice of the standard deviation. To compare the average order of muscle contraction onset time, a Freedman two-way analysis of variance by ranks was used. The relative difference between muscle contraction onset time wearing and not wearing a lumbosacral corset was measured using a paired t-test. A difference in the average muscle contraction onset order for the rectus abdominis, gluteus maximus, and semitendinosus muscles was observed (p<.05) among three positions. However, wearing a lumbosacral corset did not. change the contraction order. In addition, wearing a lumbosacral corset produced a significant difference (p<.05) in the relative onset time between the rectus abdominis and gluteus maximus in the standing position, but no difference was observed for the other muscles or positions. In the future, patients suffering from low back pain should be compared with normal subjects to determine the effectiveness of a lumbosacral corset in changing muscle recruitment order.

  • PDF

Technological Achievements and Economic Development: The Significance of Technological Achievement Gap in Selected East and South Asian Countries

  • Ali, Tariq Mahmood
    • STI Policy Review
    • /
    • 제8권1호
    • /
    • pp.113-156
    • /
    • 2017
  • Although technological progress is considered a key element for economic growth and development of a country, strong empirical evidence in this regard is not available yet. Therefore, to establish the empirical link between technology progress and economic development, it is advisable to carry out a time series analysis. In this regard, the Technology Achievement Index (TAI) of 100 top economies has been developed to examine the position of countries' technological progress for the 21 years spanning 1995 to 2015. Countries have been ranked on their TAI which is based on four pillars; technology creation, diffusion of older innovations, diffusion of recent innovations, and development of human skills. As well, this current study re-calculates the Humane Development Index (HDI) of 100 top economies for the 21 years from 1995 to 2015. Ranking of countries' HDI values reflects three dimensions: A long lifespan (life expectancy index), knowledge (Education Index) and a decent standard of living (Gross National Income Index, or GNI). The Standard Deviation (SD) technique has been used to investigate the technological gap between individual countries and groups of countries or regions. For a more meaningful assessment, technological gaps from the maximum achievement value (i.e., one of the countries under study) are presented as well. To investigate the impact of technological progress on economic development, this study introduces a model in which the HDI is used as the dependent variable and the TAI and Gross Capital Formation (GCF) are used as independent variables. The HDI, TAI and GCF are used in this model as proxy variables for economic development, technological progress and capital respectively. Econometric techniques have been used to show the impact of technological progress on economic development. The results show that long-term associations exist between technology progress and economic development; the impact of technology progress on economic development is 13.2% while the impact is 4.3% higher in eight selected East South Asian countries, at 13.5%, than in eight selected highly developed countries (9.2%).

Feature Extraction and Evaluation for Classification Models of Injurious Falls Based on Surface Electromyography

  • Lim, Kitaek;Choi, Woochol Joseph
    • 한국전문물리치료학회지
    • /
    • 제28권2호
    • /
    • pp.123-131
    • /
    • 2021
  • Background: Only 2% of falls in older adults result in serious injuries (i.e., hip fracture). Therefore, it is important to differentiate injurious versus non-injurious falls, which is critical to develop effective interventions for injury prevention. Objects: The purpose of this study was to a. extract the best features of surface electromyography (sEMG) for classification of injurious falls, and b. find a best model provided by data mining techniques using the extracted features. Methods: Twenty young adults self-initiated falls and landed sideways. Falling trials were consisted of three initial fall directions (forward, sideways, or backward) and three knee positions at the time of hip impact (the impacting-side knee contacted the other knee ("knee together") or the mat ("knee on mat"), or neither the other knee nor the mat was contacted by the impacting-side knee ("free knee"). Falls involved "backward initial fall direction" or "free knee" were defined as "injurious falls" as suggested from previous studies. Nine features were extracted from sEMG signals of four hip muscles during a fall, including integral of absolute value (IAV), Wilson amplitude (WAMP), zero crossing (ZC), number of turns (NT), mean of amplitude (MA), root mean square (RMS), average amplitude change (AAC), difference absolute standard deviation value (DASDV). The decision tree and support vector machine (SVM) were used to classify the injurious falls. Results: For the initial fall direction, accuracy of the best model (SVM with a DASDV) was 48%. For the knee position, accuracy of the best model (SVM with an AAC) was 49%. Furthermore, there was no model that has sensitivity and specificity of 80% or greater. Conclusion: Our results suggest that the classification model built upon the sEMG features of the four hip muscles are not effective to classify injurious falls. Future studies should consider other data mining techniques with different muscles.

스마트폰 IMU와 WPS를 결합한 복합 측위 방법론 (Hybrid Algorithmic Framework Using IMU and WPS for Smart Phone Positioning Systems)

  • 김재훈;강석연
    • 한국통신학회논문지
    • /
    • 제38C권8호
    • /
    • pp.663-673
    • /
    • 2013
  • 무선인터넷과 이동통신 기술의 발달 및 스마트폰의 급속한 확산으로 인해 사용자의 현재 및 과거의 위치 정보를 사용하여 다양한 부가정보를 제공하는 위치기반 서비스에 대한 관심이 급증하고 있다. 위치기반 서비스의 본격적인 활성화를 위해서는 정확한 측위가 기본이 된다. GPS (Global Positioning System)과 WPS (Wi-Fi Positioing System)가 상용화 되면서 측위 기술에 일대 혁신을 가져왔으나 실내환경에서 많은 제약을 가졌다. 이에 관성센서(IMU: Inertia Motion Unit)를 사용한 네비게이션 (Navigation)기술을 실내환경에서 응용하려는 시도가 정밀 측위의 관점에서 논의되고, 관성센서의 장착이 스마트폰에 일상화 되면서 실내 정밀 측위 확산의 시초를 갖게 되었다. 본 논문에서는 IMU와 WPS를 결합하여 각각의 단점을 극복하고 측위 품질을 혁신적으로 향상 시킬 수 있는 알고리즘 프레임워크를 제안한다. 본 연구를 위해 스마트폰에서 구현되는 측위 테스트 프로그램을 구현하고 이를 적용할 실질적인 실내외 테스트베드를 구성하여 활용하였으며 이로서 대규모로 확장 적용할 수 있는 기반을 구성했다는 면에서 충분한 의미를 지닌다.

특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구 (Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System)

  • 이수경;홍대화
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.85-90
    • /
    • 2011
  • 본 연구는 국내 고층건물 특별피난계단의 부속실에 설치되는 급기가압 제연시스템에서 화재 발생 시 피난을 위하여 출입문이 개방되었을 경우 형성되는 방연풍속의 특성을 FDS를 이용하여 해석하였고, 해석 결과를 분산분석으로 기류의 특성에 따른 측정 방안을 분석하고자 한다. 부속실과 같은 구획공간의 설계 조건에서 급기댐퍼에서 토출되는 보충량은 심한 와류를 형성하고 형성된 와류의 범위 안에 출입문이 존재할 경우 비정상적인 기체의 유동이 출입문지점에 발생한다는 것을 선행연구를 통하여 확인할 수 있었다. 국가화재안전기준 NFSC 501A에서 방연풍속을 측정할 때에는 출입문의 개방에 따른 개구부를 대칭적으로 균등 분할하는 10 이상의 지점에서 측정하는 풍속의 평균치로 할 것으로 정하고 있으나 이러한 조건에서는 출입구 상부 지점에 기류의 유입 현상을 파악하기 어렵고 풍속의 편차가 심하기 때문에 측정점을 공기조화설비의 시험조정 평가 기술기준에서 제시하는 64점 이상으로 세분화하여 측정하여야 할 것이다.

Study on the Effect of Air Circulator on Temperature Distribution in an Oyster Mushroom Farm

  • Jeong, Won Geun;Lim, Hack Kyu;Kim, Tae Han
    • Journal of Biosystems Engineering
    • /
    • 제38권2호
    • /
    • pp.81-86
    • /
    • 2013
  • Purpose: Recently, domestic and abroad consumption of mushroom has been increasing. Especially, oyster mushroom has been the most consumed product, sharing one third of the mushroom market. The air temperature differences between relative positions of the mushroom farms were needs to be minimal. However, in reality, the air temperature differences ranged from 2 to $5^{\circ}C$. Because of this, the mushrooms are non-uniform growth as well as decrease in both quality and quantity. Although air circulators have been employed by oyster mushroom farms to minimize air temperature differences, no experiments have been performed to illustrate the effect of the air circulators. Methods: This experiment is designed to analyze the effect of the air circulation by constructing a prototype air circulator and measuring the air temperature when the circulator was position at different heights (50 cm, 150 cm, 200 cm) from the floor in the center. Result: The horizontal plane air temperature of the first growing bed when the air circulator was installed 50cm above the floor in the center, once not using the air circulators and the other time using the air circulators, yielded the air temperature differences of $8.6^{\circ}C$ and $1.8^{\circ}C$ and deviations of 2.82 and 0.60, respectively. The third growing bed's air temperature differences were $10.0^{\circ}C$, $1.6^{\circ}C$ and deviations 3.28, 0.64, each respectively. These outcomes proved that the use of air circulators minimized the air temperature difference and deviation. The use of air circulators helped minimize the air temperature differences and the derivations in oyster mushroom farm. Conclusion: The use of air circulators helped balance the air temperature distribution in oyster mushroom farm.

복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고- (A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF