• Title/Summary/Keyword: deviation analysis

Search Result 3,574, Processing Time 0.033 seconds

Development of Empirical Fragility Function for High-speed Railway System Using 2004 Niigata Earthquake Case History (2004 니가타 지진 사례 분석을 통한 고속철도 시스템의 지진 취약도 곡선 개발)

  • Yang, Seunghoon;Kwak, Dongyoup
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.11
    • /
    • pp.111-119
    • /
    • 2019
  • The high-speed railway system is mainly composed of tunnel, bridge, and viaduct to meet the straightness needed for keeping the high speed up to 400 km/s. Seismic fragility for the high-speed railway infrastructure can be assessed as two ways: one way is studying each element of infrastructure analytically or numerically, but it requires lots of research efforts due to wide range of railway system. On the other hand, empirical method can be used to access the fragility of an entire system efficiently, which requires case history data. In this study, we collect the 2004 MW 6.6 Niigata earthquake case history data to develop empirical seismic fragility function for a railway system. Five types of intensity measures (IMs) and damage levels are assigned to all segments of target system for which the unit length is 200 m. From statistical analysis, probability of exceedance for a certain damage level (DL) is calculated as a function of IM. For those probability data points, log-normal CDF is fitted using MLE method, which forms fragility function for each damage level of exceedance. Evaluating fragility functions calculated, we observe that T=3.0 spectral acceleration (SAT3.0) is superior to other IMs, which has lower standard deviation of log-normal CDF and low error of the fit. This indicates that long-period ground motion has more impacts on railway infrastructure system such as tunnel and bridge. It is observed that when SAT3.0 = 0.1 g, P(DL>1) = 2%, and SAT3.0 = 0.2 g, P(DL>1) = 23.9%.

Visualization and Localization of Fusion Image Using VRML for Three-dimensional Modeling of Epileptic Seizure Focus (VRML을 이용한 융합 영상에서 간질환자 발작 진원지의 3차원적 가시화와 위치 측정 구현)

  • 이상호;김동현;유선국;정해조;윤미진;손혜경;강원석;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • In medical imaging, three-dimensional (3D) display using Virtual Reality Modeling Language (VRML) as a portable file format can give intuitive information more efficiently on the World Wide Web (WWW). The web-based 3D visualization of functional images combined with anatomical images has not studied much in systematic ways. The goal of this study was to achieve a simultaneous observation of 3D anatomic and functional models with planar images on the WWW, providing their locational information in 3D space with a measuring implement using VRML. MRI and ictal-interictal SPECT images were obtained from one epileptic patient. Subtraction ictal SPECT co-registered to MRI (SISCOM) was performed to improve identification of a seizure focus. SISCOM image volumes were held by thresholds above one standard deviation (1-SD) and two standard deviations (2-SD). SISCOM foci and boundaries of gray matter, white matter, and cerebrospinal fluid (CSF) in the MRI volume were segmented and rendered to VRML polygonal surfaces by marching cube algorithm. Line profiles of x and y-axis that represent real lengths on an image were acquired and their maximum lengths were the same as 211.67 mm. The real size vs. the rendered VRML surface size was approximately the ratio of 1 to 605.9. A VRML measuring tool was made and merged with previous VRML surfaces. User interface tools were embedded with Java Script routines to display MRI planar images as cross sections of 3D surface models and to set transparencies of 3D surface models. When transparencies of 3D surface models were properly controlled, a fused display of the brain geometry with 3D distributions of focal activated regions provided intuitively spatial correlations among three 3D surface models. The epileptic seizure focus was in the right temporal lobe of the brain. The real position of the seizure focus could be verified by the VRML measuring tool and the anatomy corresponding to the seizure focus could be confirmed by MRI planar images crossing 3D surface models. The VRML application developed in this study may have several advantages. Firstly, 3D fused display and control of anatomic and functional image were achieved on the m. Secondly, the vector analysis of a 3D surface model was defined by the VRML measuring tool based on the real size. Finally, the anatomy corresponding to the seizure focus was intuitively detected by correlations with MRI images. Our web based visualization of 3-D fusion image and its localization will be a help to online research and education in diagnostic radiology, therapeutic radiology, and surgery applications.

  • PDF

Improvement of Total Chrolophill Analytical Methods for the Chlorella Products with Extended Products Types (신 제형 클로렐라제품의 총 엽록소 시혐법 개선)

  • Kim, Yoo-Kyung;Lee, Eun-Suk;Han, Jae-Gab;No, Gi-Me;Lim, Dong-Gil;Jung, Ja-Young;Park, Young-Sig
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.1
    • /
    • pp.70-75
    • /
    • 2011
  • A new and improved analytical method involving alkaline pyridine extraction was proposed to quantity chlorophyll contents in syrup and candy type chlorella products. The performance of analytical method was compared with the conventional Korea food standard method which involves acetone extraction. The application of sonication chlorophyll extraction form alkaline pyridine sample was also explored. The analytical procedure was validated by evaluating accuracy, precision and reproducibility. For liquid samples, the pyridine extraction method showed higher accuracy and precision compared to acetone extraction method. The CV values of pyridine extract method and the acetone extraction method were 18.82 and 40.0, and the accuracy to theoretical values were 106.3% and 78.1%, respectively. When sonication extraction method was applied to the pyridine extraction, the precision was improved as indicated by reduced CV values from 18.82 to 11.36. The improved performance of pyridine-sonication extraction was also validated by recovery test of chlorophyll that was previously spiked into the sample matrix. For solid matrix, the pyridine extraction method showed better performance in analysis of chlorophyll in solid food matrix (CV = 7.05) compared to conventional acetone extraction method (CV = 30.0). However, the accuracy to theoretical values of pyridine and acetone extraction methods only showed only 62.7% an 40%, respectively. The relatively low accuracy of pyridine extraction method (62.7%) was improved to 99.4% by applying additional sonication extraction method. The improved performance of applying additional sonication extraction was validated by standard deviation, CV values and accuracy to theoretical values.

A Study on the recognition and Attitude of Home Health Nursing System (가정간호사 제도에 대한 인식 및 태도 조사연구)

  • Lee Sung Ja
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.1
    • /
    • pp.132-146
    • /
    • 1998
  • This Study was attempted to provide the basic data necessary in the development and introduction of Home Health Nursing System by investigating the recognition and attitude level of Home Health Nursing System. The data were collected by means of questionaires presented to 74 patients who had been admitted in C general hospital in Chon Ju, from June 30, 1997. As the tool for this study, the questionares developed by Kim Yong. Soon, et al (1990) and Han Bok Hee(1993) were modified and supplemented for the aim of this study. The computer was used for data analysis. The items about the charateristics of the subjects and the attitude to the management plan of Home Health Nursing System were represented as the frequency and percentage. The standard deviation and calculation average were produced on the items related to definition, recognition, necessity, expected effect of the attitude of Home Health Nursing System and the items related to admission. The ANOVA test was .used according to the characteristics of variables to analyze the necessity and difference of Home Health Nursing System. The results of this study were as follows 1) The general characteristics of the subjects were as follows ; for sex, man, $58.1\%$ ; for age, 50-59 years, $29.7\%$ ; for the level of education, high school, $51.4\%$ ; $79.7\%$ of them were married; for the family forms, small family, $73.0\%$ ; and $68.9\%$ of them take the monthly income over 100 million won. 2) The characteristics related to admissions of the subjects were as follows ; for clinic, surgical department, $78.4\%$ ; addmission not more then 7days, $47.3\%$ ; for the operation-performance $71.6\%$ of them were experienced; for the admission route, via outpatients clinic, $54.1\%$ ; for waiting period to the admission day, 1-2 days, $71.6\%$. 3) The difficulties comming from the hospitalization were related mostly to the factor that they felt hospital life more inconvenient than home.(3.66) The reasons for the difficulties in the admission which was due to insufficient beds in the hospital was related to the concentration to the general hospital because of 'The Whole National Medical Insurance System'(4.05). 4) On the previous informations about the Home Health Nursing System, those who have heard of only the name were 42 $(56.8\%)$, and on the recognition of it, they thought that it is periodic treatment by the licenced nurses for the recovering pateints after early discharge(3.73). On the attitude about the necessity of Home Health Nursing System, they thought that it is necessary because of the increasing trend of a psychological disease by the change of environment and complexity of the social structure(4.24). On the expected effect of Home Health Nursing System, they answered that it is convinient for the family of the patient to take care of them(4.l8). 5) On the attitude to the management plan of the Home Health Nursing System, those who had intention to participate in the system in the case of systemic support were 42(56.8). In the visiting time, 'visit periodically' and 'visit when the patient needs' were $28(37.8\%)$ respectively. For the application of medical insurance, if possoble, they will use $(91.9\%)$; for the method of payment for the treatment, 'pay by the time required' was $23(31.1\%)$, for the subject of management, 'National public institute must operate' was $33(44.6\%)$. 6) The relationship between the general characteristics of the subjects and the necessity of Home Health Nursing System showed the notable difference in the age (F=3.508, P<0.05) and marrage state (F=5.402, P<.023).

  • PDF

A Study on Reduction Effect of Processing Wastewater by Introduction of PACS (PACS 도입에 의한 현상시스템 폐수 감소효과에 관한 연구)

  • Ko, Shin-Kwan;Han, Dong-Kyoon;Kim, Wook-Dong;Kang, Bung-Sam;Yang, Han-Jun
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.167-175
    • /
    • 2007
  • There are some positive effects by the introduction of PACS(Picture Archiving Communication System). This study is to analyze the mutual relation between before and after of the introduction of PACS in terms of the environment effect. It is supposed to cause the reduction of developing and fixing wastewater according to the increase in the rate of a non-film. This study will also show the amount of wastewater. Target places were the department of image medicine(diagnostic radiation) of the general hospitals in Seoul and Gyeonggi-Do, which are equiped with full PACS. The authors examined questionnaires on the number of projection, the number of indirect projection, the amount of the film used, the number of radiation image CD loan, the amount of the developing and fixing solution used, the change of the amount of fixing wastewater. According to the analysis, we analyzed the change of the amount of developing and fixing solution per a film and the change of the amount of developing and fixing wastewater which is supposed to be reduced proportionally by the introduction of PACS. We got conclusion as below after analyzing 8 hospitals except the largest and the least amount of examination, film used, developing and fixing solution and the amount of developing and fixing wastewater in order to decrease the deviation from 10 general hospitals located in Seoul and Gyeonggi-Do. We compared data one year before adopting PACS Versus 3 years after adopting PACS. 1. The frequences of examination increased to 7,357.7 cases per month but the amount of film used decreased to 90%, from 42,774.4 to 4,181.88 after adopting the PACS. 2. 3 years after adopting PACS, monthly average amount of developing solution used decreased to 92% and the monthly average amount of fixing solution decreased to 86%. 3. Monthly average amount of developing solution used per film increased to 1.49 times and fixing solution increased as much as three times. 4. Monthly average wastewater for developing decreased to 88% and wastewater for fixing decreased up to 87%. 5. Monthly average wastewater for developing per film increased to 3.77 times and wastewater for fixing increased to 3.85 times. Although the amount of film used and the amount of developing and fixing wastewater affected by the reduction of the developing and fixing solution became less on the whole by introduction of PACS, they did not decrease proportionally. Moreover the amount of the developing and fixing solution used and the amount of developing and fixing wastewater per a film increased. That means the expectation for an environmental improvement differs from the actual condition.

  • PDF

Alteration Analysis of Normal Human Brain Metabolites with Variation of SENSE and NEX in 3T Multi Voxel Spectroscopy (3T Multi Voxel Spectroscopy에서 SENSE와 NEX 변화에 따른 정상인 뇌 대사물질 변화 분석)

  • Seong, Yeol-Hun;Rhim, Jae-Dong;Lee, Jae-Hyun;Cho, Sung-Bong;Woo, Dong-Chul;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.256-262
    • /
    • 2008
  • To evaluate the metabolic changes in normal adult brains due to alterations SENSE and NEX (number of excitation) by multi voxel MR Spectroscopy at 3.0 Tesla. The study group was composed of normal volunteers (5 men and 8 women) with a mean ($\pm$ standard deviation) age of 41 (${\pm}11.65$). Their ages ranged from 28 to 61 years. MR Spectroscopy was performed with a 3.0T Achieva Release Version 2.0 (Philips Medical System-Netherlands). The 8 channel head coil was employed for MRS acquisition. The 13 volunteers underwent multi voxel spectroscopy (MVS) and single voxel spectroscopy (SVS) on the thalamus area with normally gray matter. Spectral parameters were as follows: 15 mm of thickness; 230 mm of FOV (field of view); 2000 msecs of repetition time (TR); 288 msecs of echo time (TE); $110{\times}110$ mm of VOI (view of interest); $15{\times}15{\times}15$ mm of voxel size. Multi voxel spectral parameters were made using specially in alteration of SENSE factor (1~3) and 1~2 of NEX. All MRS data were processed by the jMRUI 3.0 Version. There was no significant difference in NAA/Cr and Cho/Cr ratio between MVS and SVS likewise the previous results by Ross and coworkers in 1994. In addition, despite the alterations of SENSE factor and NEX in MVS, the metabolite ratios were not changed (F-value : 1.37, D.F : 3, P-value : 0.262). However, line-width of NAA peak in MVS was 3 times bigger than that in SVS. In the present study, we demonstrated that the alterations of SENSE factor and NEX were not critically affective to the result of metabolic ratios in the normal brain tissue.

  • PDF

Impact of Pulmonary Vascular Compliance on the Duration of Pleural Effusion Duration after Extracardiac Fontan Procedure (수술 전 폐혈관 유순도가 심장 외 도판을 이용한 Fontan 수술 후 늑막 삼출 기간에 미치는 영향)

  • Yun Tae-Jin;Im Yu-Mi;Song Kwang-Jae;Jung Sung-Ho;Park Jeong-Jun;Seo Dong-Man;Lee Moo-Song
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.579-587
    • /
    • 2006
  • Background: Preoperative risk analysis for Fontan candidates is still less than optimal in that patients with apparently low risks may have poor surgical outcome; prolonged pleural drainage, protein losing enteropathy, pulmonary thromboembolism and death. We hypothesized that low pulmonary vascular compliance (PVC) is a risk factor for prolonged pleural effusion drainage after the Fontan operation. Material and Method: A retrospective review of 96 consecutive patients who underwent the Extracardiac Fontan procedures (median age: 3.9 years) was performed. Fontan risk score (FRS) was calculated from 12 categorized preoperative anatomic and physiologic variables. PVC $(mm^2/m^2{\cdot}mmHg)$ was defined as pulmonary artery index $(mm^2/m^2)$ divided by total pulmonary resistance $(W.U{\cdot}/m^2)$ and pulmonary blood flow $(L/min/m^2)$ based on the electrical circuit analogue of the pulmonary circulation. Chest tube indwelling time was log-transformed (log indwelling time, LIT) to fit normal distribution, and the relationship between preoperative predictors and LIT was analyzed by multiple linear regression. Result: Preoperative PVC, chest tube indwelling time and LIT ranged from 6 to 94.8 $mm^2/mmHg/m^2$ (median: 24.8), 3 to 268 days (median: 20 days), and 1.1 to 5.6 (mean: 2.9, standard deviation: 0.8), respectively. FRS, PVC, cardiopulmonary bypass time (CPB) and central venous pressure at postoperative 12 hours were correlated with LIT by univariable analyses. By multiple linear regression, PVC (p=0.0018) and CPB (p=0.0024) independently predicted LIT, explaining 21.7% of the variation. The regression equation was LIT=2.74-0.0158 PVC+0.00658 CPB. Conclusion: Low pulmonary vascular compliance is an important risk factor for prolonged pleural effusion drainage after the extracardiac Fontan procedure.

Interpretation on Making Techniques of Some Ancient Ceramic Artifacts from Midwestern Korean Peninsula: Preliminary Study (한반도 중서부 출토 일부 고대 세라믹 유물의 제작기술 해석: 예비 연구)

  • Lee, Chan Hee;Jin, Hong Ju;Choi, Ji Soo;Na, Geon Ju
    • Journal of Conservation Science
    • /
    • v.32 no.2
    • /
    • pp.273-291
    • /
    • 2016
  • Some ceramic artifacts representing time-wise from comb pattern pottery in the Neolithic Age to white porcelain in Joseon Dynasty were selected from 7 sites in the north and south area of Charyeong Mountain Range in order to making techniques interpretation and development process of ancient ceramics through physicochemical and mineralogical quantitative analysis. Studied pottery samples in the Prehistoric times showed trace of ring piling in soft-type, and pottery in the Three Kingdoms Period had both soft and hard-type but kettle-ware and storage-ware were made with ring piling, but table-ware was made by wheel spinning. Different from pottery after the Three Kingdom Period when refinement of source clay was high, pottery in the Neolithic Age and in the Bronze Age exhibited highly mineral content in sandy source clay, which showed a lot of larger temper than source clay. Groundmass of celadon and white porcelain almost did not reveal primary minerals but had high content of minerals by high temperature firing. Ceramic samples showed some different in major and minor elements according to sites irrespective of times. Geochemical behaviors are very similar indicating similar basic characteristics of source clay. However, loss-on-ignition showed 0.01 to 12.59wt.% range with a large deviation but it rapidly decreased moving from the Prehistoric times to the Three Kingdom Period. They have correlation with the weight loss due to firings, according to burning degree of source clay and detection of high temperature minerals, estimated firing temperatures are classified into 5 groups. Pottery in the Neolithic Age and in the Bronze Age belongs from 750 to $850^{\circ}C$ group; pottery in the Three Kingdom Period are variously found in 750 to $1,100^{\circ}C$ range of firing temperature; and it is believed celadon and white porcelain were baked in high temperature of 1,150 to $1,250^{\circ}C$. It seems difference between refinement of source clay and firing temperature based on production times resulted from change in raw material supply and firing method pursuant to development of production skill. However, there was difference in production methods even at the same period and it is thought that they were utilized according to use purpose and needs instead of evolved development simply to one direction.

The Study on the Confidence Building for Evaluation Methods of a Fracture System and Its Hydraulic Conductivity (단열체계 및 수리전도도의 해석신뢰도 향상을 위한 평가방법 연구)

  • Cho Sung-Il;Kim Chun-Soo;Bae Dae-Seok;Kim Kyung-Su;Song Moo-Young
    • The Journal of Engineering Geology
    • /
    • v.15 no.2 s.42
    • /
    • pp.213-227
    • /
    • 2005
  • This study aims to assess the problems with investigation method and to suggest the complementary solutions by comparing the predicted data from surface investigation with the outcome data from underground cavern. In the study area, one(NE-1) of 6 fracture zones predicted during the surface investigation was only confirmed in underground caverns. Therefore, it is necessary to improve the confidence level for prediction. In this study, the fracture classification criteria was quantitatively suggested on the basis of the BHTV images of NE-1 fracture zone. The major orientation of background fractures in rock mass was changed at the depth of the storage cavern, the length and intensity were decreased. These characteristics result in the deviation of predieted predicted fracture properties and generate the investigation bias depending on the bore hole directions and investigated scales. The evaluation of hydraulic connectivity in the surface investigation stage needs to be analyze by the groundwater pressures and hydrochemical properties from the monitoring bore hole(s) equipped with a double completion or multi-packer system during the test bore hole is pumping or injecting. The hydraulic conductivities in geometric mean measured in the underground caverns are 2-3 times lower than those from the surface and furthermore the horizontal hydraulic conductivity in geometric mean is six times lower than the vertical one. To improve confidence level of the hydraulic conductivity, the orientation of test hole should be considered during the analysis of the hydraulic conductivity and the methodology of hydro-testing and interpretation should be based on the characteristics of rock mass and investigation purposes.

Analysis of Diflubenzuron in Agricultural Commodities by Multiresidue Method (동시 다성분 분석법에 의한 농산물 중 Diflubenzuron 분석)

  • Park, Sun-Hee;Han, Chang-Ho;Kim, Ae-Kyung;Shin, Jae-Min;Lee, Jae-Kyoo;Park, Young-Hae;Kim, Ji-Min;Hwang, Lae-Hong;Chang, Min-Su;Song, Mi-Ok;Park, Ju-Sung;Yun, Eun-Sun;Kim, Mu-Sang;Jung, Kweon
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.269-277
    • /
    • 2014
  • The multiclass pesticide multiresidue method for the simultaneous determination of diflubenzuron in agricultural products was conducted by using HPLC-UVD. The method was validated through the guidelines of linearity, specificity, limit of detection (LOD), limit of quantification (LOQ), accuracy and precision with pesticide-free spinach, Korean cabbage, eggplant, squash, sweet pepper, cucumber, Korean melon. The calibration curve of diflubenzuron was linear over the concentration range of 0.05-5 mg/kg with correlation coefficient of above 0.99999. The limit of detection and quantification was 0.008 and 0.02 mg/kg. Mean recoveries of diflubenzuron for each sample were 77.5-105.6%. Relative standard deviation (RSD) in recoveries were all less than 20%. The intra-day and inter-day precision (RSD) were 0.4-1.9% and 0.7-1.9%, respectively. The result of validation indicated that this method was accurate and rapid assay.