• 제목/요약/키워드: development of measurement tool

검색결과 526건 처리시간 0.028초

자종공무마모계측시스템개발 (System Development for Automatic Tool Wear Measurement)

  • Kim, Y.I.
    • 한국정밀공학회지
    • /
    • 제11권6호
    • /
    • pp.185-199
    • /
    • 1994
  • This study has been performed to present a new automatic tool wear measurement by digital image processing. The purpose of this paper is to develop an automatic tool wear measuring system based on the image processing which can be applied to the quasi-real time measurement of the characteristics of insert tip in turning. Tool wear monitoring is one of the key-problems, for the development of control systems of modern unmanned factory which are not completely solved now. In oredr words at present complete qualitative and quantitative information on tool wear morphology is required, at least on the following aspects : flank wear, its dimensions and distribution on the maximum and mean values on VB pqrqmeter in the various zones of the wearland. crater wear, its main dimensions and values of KT parameters. This research has been performed to this technique made possible by designing a proper lighting system to the worn tool with following features : The flank wear is measured by observing the active cutting part from a proper direction and by lighting the wearland by a diffuser optic system. The crater wear is visualized by lighting the tool by a He-Ne gas laser system developed in this study. By means of this system it is research to evaluate classical parameters of tool wear and to have complete information about tool wear morphology.

  • PDF

투약과 수혈간호의 간호과정 적용 평가도구 개발 (Development of the Nursing Process Based Performance Measurement Tool for Medication Management and Blood Transfusion)

  • 김금순;김진아;권소희;송말순
    • 임상간호연구
    • /
    • 제16권1호
    • /
    • pp.177-196
    • /
    • 2010
  • Purpose: This study was conducted to develop the nursing process based performance measurement tool and the evidence based care standards for nursing care in medication management and blood transfusion. Methods: The care standards and performance measurement tool were drafted through comprehensive review of relevant literature, national guidelines, hospital protocols, and standards of recognized international accrediting bodies. The proposed care standards and performance measurement tool were reviewed by the panel of experts and refined based on the panel's suggestions. Final care standards and performance measurement tool were validated by surveying the hospital nurses. Results: All items of the performance measurement tool for medication management and blood transfusion were evaluated appropriate. All contents of care standards and the measurable elements except the evaluation of discharge education were appropriate. The performance measurement tool developed in this study was found to be acceptable as a tool to evaluate quality of nursing care in medication management and blood transfusion. Conclusion: The outcomes of this study including the performance measurement tool and evidence based care standards would be the important indicators to monitor whether necessary nursing care is implemented and be the useful primary resources to improve quality of nursing care services.

환자간호의 질 평가를 위한 돌봄(caring) 측정도구의 개발 (Development of a Measurement Tool of Caring to Evaluate Quality of Nursing Care)

  • 이병숙
    • 대한간호학회지
    • /
    • 제26권3호
    • /
    • pp.653-667
    • /
    • 1996
  • It is important to find indicators of quality nursing care to establish the excellence of nursing practice and for the development of nursing as a profession. Caring is one of the indicators which can represent professional nursing care. The purpose of this study was to develop a measurement tool of caring that could be used as an instrument for the evaluation of quality of nursing care. The Target population for the developed tool of caring is the adult patient. The mearsurement tool of caring was developed through the following steps. (1) A list of caring behaviors was made using qualitative researches on caring that has been done in Korea. (2) Caring behaviors in nurses were selected using the list of caring behaviors developed from Watson's 10 factors of caring. (3) Items for the measurement tool of caring were developed using the caring behaviors of nurses (4) Content validity of the developed items was evaluated by an expert panel. (5) The mearsurement tool of caring was developed after a pilot study (6) Internal consistency, and construct validity of the developed tool were verified. (7) The mearsurement tool of caring with the items verified for the internal consistency and construct validity was confirmed. As a result of the study, a mearsurement tool of caring, composed of 27 items with 3 factors, was developed. The Reliability coefficient of the tool was. 9578. The tool is a 5 point Likert scale. The factors of the tool and the number of items for each factor are, 1) accessibility and availablility, 15 items ; 2) emotional support and giving information, 8 items ; 3) providing a protective environment, 4 items.

  • PDF

공구감시 시스템의 보정장치 개발과 평가에 관한 연구 (Development and Evaluation of Automatic Tool Compensation System)

  • 정상화;신현성;차경래
    • 한국공작기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.93-99
    • /
    • 2002
  • In general, manufacturing error is originated from bad material, machine tool defection and tool breakage. When the manufacturing process is stable, the most of error come from the tool wear. In common on-machine measurement teaching probe and touch sensor are widely used however in this paper the electric touch point type automatic tool compensation system is developed the performance of it is validated and effective operating is proposed.

의료기관 사회적 책임활동 측정 도구개발 및 타당화 (Development and Validation of the Hospital's CSR Measurement Tool)

  • 조경원;사공미;조민제
    • 보건의료산업학회지
    • /
    • 제12권2호
    • /
    • pp.149-162
    • /
    • 2018
  • Objectives : This study aimed to develop tools to measure the social responsibility activities of hospitals using ISO 26000 and to verify the validity and reliability of the developed tools. We verified the content and structural validity, as well as the internal consistency of the proposed measurement tool for hospitals' social responsibility. Methods : We conducted an online survey on hospitals/employees from Feb 26 to Mar 12, 2018, and analyzed selected 197 respondents from the survey by removing incomplete responses. Results : The developed hospitals' CSR (HSR) measurement tool consists of 36 items with 5 factors: "consumer issues", "labor practices", "community involvement & development", "fair operating practice", and "environment". Analysis revealed high reliability with Cronbach' alpha of 0.981. Conclusions : It was verified that the developed HSR tool fully reflected hospital characteristics. This tool can be used to diagnose hospitals' social responsibility and to support strategic decision on social responsibility.

DBB를 이용한 5축 복합가공기의 오차 측정 시스템 개발에 관한 연구 (The Development of An Error Measurement System of 5-Axis Mill & Turn Machine Tool by Double Ball Bar Test)

  • 김태한;정윤교;고해주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.243-244
    • /
    • 2006
  • In this paper, the development of an error measurement system of 5-axis mill & turn machine tool presented by double ball bar test, which has been widely used to measure the overall accuracy of machining center. and the reliability of an error measurement system of 5-axis mill & turn machine tool was secured by the direct cutting test.

  • PDF

머시닝센터용 자동공구보정시스템의 개발 (Development of an Automatic Tool Compensation System for M/C)

  • 정상화;신현성;김현욱
    • 한국공작기계학회논문집
    • /
    • 제10권4호
    • /
    • pp.48-54
    • /
    • 2001
  • The tool wear that is developed by long-term machining in mold manufacturing with machining center makes a severe influence to the accuracy and the surface roughness. in this reason, tool-wear supervising system which has guaranteed high accuracy and high speed is needed to improve the measurement quality. Touching probe and touch sensor are widely used to measure the tool profile at on-machine measurement. In this paper, using the newly developed electric touch point measuring system, the Automatic Tool Compensation System is developed to correct the error of tool diameter resulted from the wear, and the operating method of this system is also provided.

  • PDF

병원 위탁급식 품질관리를 위한 품질평가도구 개발 (The Development of a Quality Measurement Tool for a Contract-Managed Hospital Foodservice)

  • 양일선;김현아;이영은;박문경;박수연
    • 대한지역사회영양학회지
    • /
    • 제8권3호
    • /
    • pp.319-326
    • /
    • 2003
  • The purposes of this study were: a) to develop the a quality measurement tool for the contract-managed hospital foodservice, and b) to evaluate their performance with the developed quality measurement tool, and c) to verify the reliability and validity of the quality measurement tool. The developed quality measurement tool comprised two parts, which were foodservice management and medical nutrition care service. The foodservice management part was classified into six functional categories which were Menu, Procurement and Storage, Production and Distribution, Facility and Utility, Sanitation and Safety, and Management and Evaluation. The medical nutrition care service part indicated the medical nutrition care provided. Quality measurement tool had 91 standards and 324 indicators. The quality measurement tools were distributed to the hospital foodservice manager employed by the foodservice company. The 324 indicators were measured by foodservice manager on the 5-Likert-type scales, and then adapted to a 100 point scale. The SPSS Ver. 11.0 was used for statistical analysis. The categories whose scores were evaluated as being high were Procurement', General Sanitation', Personal sanitation' and Waste' and the categories whose scores were evaluated as being low were Diet Order Manual', Standard Recipe', Appropriateness (Facility and Utility)', Check (Facility and Utility)'and Information Management'. All the categories of medical nutrition service were evaluated as having seriously low scores. Therefore, it was necessary for the contract-managed hospital foodservice to improve its performance in the area of medical nutrition care service. For the verification of the developed quality measurement tool, the reliability obtained by calculating Cronbach's α was 0.8747, and the content validity was also proved by scrutiny of the modification of the Professional group's techniques. (Korean J Community Nutrition 8(3) : 319∼326, 2003)

개인의료정보 프라이버시 염려 측정도구 개발 및 타당도 검증 (Development and Validation of Privacy Concern Measurement Tool in Personal Medical Information)

  • 이기호;정영철;한경석;송태민
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제3권6호
    • /
    • pp.197-208
    • /
    • 2014
  • 정보사회에 있어서 개인정보보호는 가장 중요한 윤리적 이슈 중 하나이다. 특히 업무특성상 진료를 목적으로 민감한 개인의 의료정보를 수집, 저장 및 처리하고 있는 의료기관의 경우 정보 유출시 개인의 사생활에 심각한 피해를 야기할 수 있다. 본 연구는 의료기관 소비자 관점에서 개인의료정보에 대한 일반적인 고객의 염려를 측정하기 위한 개인의료정보 프라이버시 염려 측정도구를 개발하고 타당도를 검증하는 것이다. 이를 위해 선행연구를 기초로 개인의료정보 프라이버시 염려 측정도구를 개발하였으며, 개발된 측정도구에 대한 탐색적 요인분석과 확인적 요인분석을 실시하여 신뢰도와 타당도를 검증하였다. 본 연구를 통해 개발된 측정도구는 국민의 개인의료정보보호에 대한 염려수준 및 관심 영역을 파악하여 적절한 개인정보보호 정책을 수립하는 데 유용하게 활용될 것으로 기대되며, 의료기관의 경우 의료서비스 소비자가 우려하는 해당 의료기관의 개인의료정보보호 문제점 및 그 수준을 파악하여 합리적인 대책을 도출하는 데 유용할 것으로 기대된다.

권역심뇌혈관질환센터의 공익성 측정도구 개발 (Development and Validation of the Measurement Tool of Public Benefits in Regional Cardiocerebrovascular Center)

  • 이건세;신은영;정효선;이정현;김희숙;임영실;김영택Kun
    • 보건행정학회지
    • /
    • 제23권4호
    • /
    • pp.434-444
    • /
    • 2013
  • Background: Regional Cardiocerebrovascular Centers (RCC) were established for the prevention and treatment of cardiocerebrovascular disease and funded by the Ministry of Health and Welfare. The purpose of this study was to develop and validate the measurement tool of public benefits in RCC. Methods: Through the intensive literature review, experts surveys and their repetitive feedback, we selected the 46 items about the public benefits in RCC. Development of measurement tool involved content validity test using Content Validity Index (CVI), construct validity test through factor analysis and reliability test. Results: Thirty-five items were selected by content validity test, which CVI was 0.08 or higher. Through the construct validity test, 32 items in 7 factors were derived. And Cronbach's alpha was 0.951. Finally, public benefits measurement tool is composed of 32 items in 7 factors which are comprehensiveness of health care services, market complement, emergency care, cost, governance, quality improvement, and government control. Conclusion: Though we developed the measurement tool of public benefits in RCC, it would be utilized to measure the public benefits of various health agencies.