• 제목/요약/키워드: deterioration degree

검색결과 306건 처리시간 0.025초

A Review on Degradation of Silicon Photovoltaic Modules

  • Yousuf, Hasnain;Khokhar, Muhammad Quddamah;Zahid, Muhammad Aleem;Kim, Jaeun;Kim, Youngkuk;Cho, Sung Bae;Cho, Young Hyun;Cho, Eun-Chel;Yi, Junsin
    • 신재생에너지
    • /
    • 제17권1호
    • /
    • pp.19-32
    • /
    • 2021
  • Photovoltaic (PV) panels are generally treated as the most dependable components of PV systems; therefore, investigations are necessary to understand and emphasize the degradation of PV cells. In almost all specific deprivation models, humidity and temperature are the two major factors that are responsible for PV module degradation. However, even if the degradation mode of a PV module is determined, it is challenging to research them in practice. Long-term response experiments should thus be conducted to investigate the influences of the incidence, rates of change, and different degradation methods of PV modules on energy production; such models can help avoid lengthy experiments to investigate the degradation of PV panels under actual working conditions. From the review, it was found that the degradation rate of PV modules in climates where the annual average ambient temperature remained low was -1.05% to -1.16% per year, and the degree of deterioration of PV modules in climates with high average annual ambient temperatures was -1.35% to -1.46% per year; however, PV manufacturers currently claim degradation rates of up to -0.5% per year.

Effect of chitosan coating combined with hypotaurine on the quality of shrimp (Litopenaeus vannamei) during storage

  • Chen, Meiyu;Hu, Lingping;Hu, Zhiheng;Zhou, Yaqi;Li, Gaoshang;Chin, Yaoxian;Hu, Yaqin
    • Fisheries and Aquatic Sciences
    • /
    • 제25권2호
    • /
    • pp.64-75
    • /
    • 2022
  • This study aimed to investigate the effect of different coating materials on the quality of shrimp (Litopenaeus vannamei) during chilled storage for 10 days. Fresh shrimp were randomly divided into five groups: the control group, the hypotaurine treatment group (2%), the chitosan group (1%), the hypotaurine + chitosan group (2% hypotaurine solution with 1% of chitosan), and the sodium metabisulfite treatment group (1.25%). Compared with other treatments, the lower accumulation of total visible counts (TVC, 5.25 Log10 CFU/g), total volatile basic nitrogen (TVB-N, 22.5 mg/100 g) and thiobarbituric acid values (TBA, 0.58 mg MDA/kg) suggested that coating of chitosan-hypotaurine could retard the microbial activity, protein degradation and lipid oxidation of shrimp. Meanwhile, results demonstrated that the chitosan coating combined with hypotaurine showed an excellent performance in inhibiting quality deterioration (pH 7.5, ∆E 7.0, hardness 393 g, and elasticity 0.69). Furthermore, the melanosis degree of shrimp was alleviated, and the sensory parameters, including appearance, odor and texture, were maintained to the acceptable level by chitosan based hypotaurine treatment during the chilled storage.

Effect of activator types on cement mortar with polymeric aluminum chloride waste residue

  • Ping Xu;Yuhao Cui;Dong Han;Minxia Zhang;Yahong Ding
    • Advances in concrete construction
    • /
    • 제15권3호
    • /
    • pp.149-159
    • /
    • 2023
  • Water glass (WG) and sodium sulfate (SS) were used to prepare polymeric aluminum chloride residue cement mortar (PACRM) by single and compound blending with polymeric aluminum chloride waste residue, respectively. The structural strength and textural characteristics examinations showed that PACRM consistency increased by incorporating WG, but decreased by incorporating SS. When WG and SS were compounded, the mortar consistency initially rose before falling. The compressive strength of PACRM increased and then decreased as WG was increased. The mechanical properties of PACRM were better enhanced by SS than WG, showing no strength deterioration. The main reason for the improved mechanical properties of polymeric aluminum chloride waste residue in the presence of activators is the increased precipitation of reactive substances, such as C-S-H gels, calcium silica, and Ca(OH)2. The density of the specimens with PACRM and the degree of aggregation of hydration products were significantly enhanced by generating more hydration products in the mortar. Further, the cracks and pores were significantly reduced, and the matrix structure was continuous and dense at 5% SS doping and 3% compound doping.

노화 시계를 이용한 알츠하이머병 환자의 후성유전학적 연령 예측 (Epigenetic Age Prediction of Alzheimer's Disease Patients Using the Aging Clock)

  • 김진영;조광원
    • 통합자연과학논문집
    • /
    • 제16권2호
    • /
    • pp.61-67
    • /
    • 2023
  • Human body ages differently due to environmental, genetic and pathological factors. DNA methylation patterns also differs depending on various factors such as aging and several other diseases. The aging clock model, which uses these differences to predict age, analyzes DNA methylation patterns, recognizes age-specific patterns, predicts age, and grasps the speed and degree of aging. Aging occurs in everyone and causes various problems such as deterioration of physical ability and complications. Alzheimer's disease is a disease associated with aging and the most common brain degenerative disease. This disease causes various cognitive functions disabilities such as dementia and impaired judgment to motor functions, making daily life impossible. It has been reported that the incidence and progression of this disease increase with aging, and that increased phosphorylation of Aβ and tau proteins, which are overexpressed in this disease and accelerates epigenetic aging. It has also been reported that DNA methylation is significantly increased in the hippocampus and entorhinal cortex of Alzheimer's disease patients. Therefore, we calculated the biological age using the Epi clock, a pan-tissue aging clock model, and confirmed that the epigenetic age of patients suffering from Alzheimer's disease is lower than their actual age. Also, it was confirmed to slow down aging.

물 시멘트비와 이산화탄소 농도에 따른 콘크리트의 장기 탄산화에 관한 해석적 연구 (According to Water Cement Ratio and Internal Temperature and Humidity, An Analytical Study on the Carbonation of Long-Term Concrete)

  • 이준해;박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.188-189
    • /
    • 2020
  • In the field of architecture, concrete and steel bars are the most common and popular combinations. The relationship between the two in a structure is a complementary good that increases in utility when consuming both materials at the same time. However, the combination of the two, which has been perceived as semi-permanent, often faces repairs or reconstruction without its lifespan reaching decades. There are a number of deterioration factors at work for the reason for this phenomenon. Among them, the neutralization of concrete in particular refers to the process in which calcium hydroxide inside concrete reacts with carbon dioxide and loses alkalinity, which creates a corrosive environment for rebars inside concrete, causing serious damage to concrete. In this study, we intend to use a multi-physical analysis program using finite element analysis method to analyze the degree of carbonation according to the internal temperature and concentration of carbon dioxide in concrete, thereby contributing to the prediction of long-term neutralization of concrete and the research related to measures for neutralization of concrete.

  • PDF

강관철근을 보강한 합성기둥의 3시간 가열 후 잔존 압축력 실험평가 (Evaluation of Residual Strength and Behavior of Reinforced STG 800 Welded Square Composite Column after Fire 3 Hour)

  • 김선희;염경수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.242-243
    • /
    • 2021
  • The concrete inside the steel tube of CFT columns enables them to have great strength and ductility. CFT columns are also excellent in fire-resistance because explosive heat upon a fire can be contained in the tube by the concrete debris. However, the studies to evaluate the residual strength of CFT columns after a fire have not been conducted enough. The studies to evaluate the residual strength of CFT columns after a fire are indispensable because it is the barometer of the damage of composite columns caused by a fire and the degree of repair and reinforcement work for the columns after a fire. Accordingly, the purpose of this study is to evaluate the deterioration of load capacity and structural behavior of square CFT columns with the same shapes and boundary conditions before and after a fire. The study also evaluates the influential factors of the CFT columns reinforced to secure the residual strength after a fire.

  • PDF

pH Swing법을 활용한 이산화탄소 반응경화형 시멘트 경화체의 CO2 고정화 성능 및 기계적 물성 개선 (Improving the CO2 Sequestration Capability and Mechanical Properties of CO2 Reactive Cement Paste Using pH Swing Method)

  • 조성민;김경률;배성철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.115-116
    • /
    • 2023
  • This study aims to investigate and improve the carbon dioxide sequestration capability and the mechanical properties of non-hydraulic low calcium silicate cement especially designed for CO2 reaction and ordinary Portland cement subjected to the carbonation curing facilitating pH swing method. Nitric acid (HNO3) was utilized as an liquid for the mixing of cement paste to enhance the initial dissolution of Ca ions from the cements by promoting low pH environment and prevent the direct precipitation of Ca with the anion, owing to the high solubility of Ca(NO3)2 in water. The results presented that the higher the concentration of HNO3, the higher the compressive strength and CO2 sequestration (until 0.1 M). Ca dissolution caused by the harsh acid attack onto the anhydrous cement particle lead to the higher carbonation reaction degree, forming abundant CaCO3 crystals after the reaction. However, cement paste mixed with excessively high concentration of HNO3 presented deterioration due to the too harsh pH environment and abundant NO3- ions which are known to retard the reaction of cement.

  • PDF

제니핀을 첨가한 아교의 접착 특성과 물성 변화 연구 (A Study on Adhesion Characteristics and Physical Properties of Animal Glue Added Genipin)

  • 이준호;유지아;정용재
    • 보존과학회지
    • /
    • 제34권3호
    • /
    • pp.157-166
    • /
    • 2018
  • 본 연구에서는 아교의 접착 특성 향상을 위해 가교제(Cross-linking Agent)를 첨가하는 방법으로 젤라틴 결합력을 증대하였다. 제니핀 첨가 아교는 물성 측정, 구조 분석, 색잔류도, 용출도, 파단강도를 측정하였으며, 수분과 자외선에 대한 내수성과 내광성을 비교하였다. 연구 결과 겔강도와 점도는 제니핀 첨가량에 따라 증가하였다. 구조분석 결과, 젤라틴에서는 구조적으로 안정된 콜라겐의 3중 구조의 흡수 피크가 관찰되었다. 색잔류도 결과, 명도가 낮아지기 때문에 피막이 관찰되는 것으로 판단된다. 용출량은 $50^{\circ}C$ 증류수에서 제니핀 첨가량이 증가할수록 용출된 아교 양이 증가하였고 파단강도는 제니핀 첨가량에 따라 증가하였다. 내수성과 내광성은 제니핀 첨가에 따른 열화 전 후 양상이 나타나지 않았다. 본 연구 결과를 바탕으로 제니핀 첨가 아교의 접착 특성을 확인할 수 있었으며 아교에 적용 가능한 실험 방법을 고찰하였다. 제니핀을 첨가한 후에도 아교 고유의 특성인 유연성, 재용해성, 접착력, 경화속도가 사라지지 않고 향상되기 때문에 균질한 아교가 확보된다면 문화재 보존 및 아교 제작에 적용이 가능할 것으로 기대한다.

관망에서의 소독부산물 변화와 관련 영향인자들의 상관관계 분석 (Variation of Disinfection-by-Prodcut in Distribution System and Evaluation of Correlation between Disinfection-by-Product and Physico-Chemical Parameters)

  • 송영일;안수나;안성윤;서대근;조혁진;이재성;최일환;신창수;이희숙
    • 대한환경공학회지
    • /
    • 제38권2호
    • /
    • pp.63-70
    • /
    • 2016
  • 수돗물 공급과정에서의 소독부산물 발생현황과 이와 관련된 수질 인자와의 상관성을 조사하여 소독부산물 발생특성을 규명하고자 K-water에서 관리하는 정수장의 수돗물 공급과정 5개 계통에 대하여 조사를 실시하였다. 수돗물 공급과정에서의 공급계통별 Water age 및 노후관 공급계통을 구분하여 조사대상을 선정하였으며, 소독부산물인 트리할로메탄 (THMs) 및 할로아세틱에시드 (HAAs), 유기물 항목으로서 BDOC 및 DOC를 포함하여 7개 항목에 대해 월 1회 조사하였다. 조사결과 노후관계통 및 Water age가 길수록 공급과정 내 유기물 농도가 높아지는 경향성을 확인할 수 있었다. 소독부산물과 관련 영향인자들의 상관관계를 분석한 결과 계통별 잔류염소 감소와 Water age간 상관관계가 매우 높은 것으로 나타났다. 또한 Water age와 THMs 생성간의 결정계수값이 매우 높아 THMs 생성에 Water age가 중요한 인자임을 알 수 있었다. 잔류염소 감소율이 THMs 증가에 미치는 영향 또한 매우 높게 나타났으며, Water age가 길어질수록 수온과 THMs 생성에 미치는 영향은 증가하는 것으로 나타났다. 이와 반면 HAAs는 THMs와는 달리 Water age, 잔류염소, 수온과의 상관관계 조사결과 결정계수 값이 낮게 나타났다.

대공간 막 구조물 지붕의 수밀성능 확보를 위한 유지관리 지표 연구 (Technical Index for the Maintenance of Watertightness of the Roof of a Large-Span Membrane Structure)

  • 오상근;김동범;이선규
    • 한국건축시공학회지
    • /
    • 제11권1호
    • /
    • pp.51-59
    • /
    • 2011
  • 최근 막 구조물의 수요 증가에 따라 막 구조물의 구조 및 재료적 연구의 진행은 막 구조물을 하나의 독립된 구조물로써 인정받을 만큼 활발히 진행되고 있지만, 유지 관리 측면의 연구의 경우 아직까지 이에 미치지 못한 상황이다. 특히 유지관리 측면에의 연구 중 지붕구조의 수밀성 및 누수에 관한 연구는 해외에서 일부만을 다루고 있어 국내 실정에 맞는 유지관리 지표 개발이 요구되고 있다. 이에 본 연구에서는 막 구조물 지붕부의 막재 및 접합부, 지붕 형태에 따른 누수취약부에 대해서의 하자 사례 조사를 통하여 누수 요인 및 열화 인자를 분석하였고, 이를 AHP기법을 활용하여 중요도를 부여하여, 막 구조물에서 필요한 유지관리 지표를 제안하였으며, 이를 바탕으로 막 구조물 지붕의 장기적으로 수밀성 확보를 위한 설계 및 시공단계서의 수밀성 평가 지표, 준공 후 사용과정에서의 점검 관리 지표를 제안하였다.