수변공간을 활용한 오염부하 저감 및 차단 융복합 기술의 하천 적용성 평가 (Assessment of the Applicability of Convergence Technology for Reducing and Blocking Pollution Loads to Rivers through the Utilization of Waterfront Spaces)

  • 김봉균;서대석;오종민;박재로
    • Ecology and Resilient Infrastructure
    • /
    • 제3권4호
    • /
    • pp.238-246
    • /
    • 2016
  • 본 연구에서는 그동안 방치되어 왔던 하천 제방 및 둔치 등의 수변공간에 저류지, 인공습지 및 생태호안의 세가지 요소기술을 연계 활용한 수질정화시설을 제조하여 설치한 뒤 강우시 및 비강우시에 따라 성능을 분석하였다. 연구 결과에 따르면 강우시에는 SS, BOD, T-N, T-P에 대하여 평균 48.6%, 30.5%, 18.4%, 27.3%의 제거효율을 보였으며, 비강우시에는 33.2%, 28.6%, 13.7%, 17.3%로 나타났다. 그러므로 본 연구에서 수변공간을 활용하여 설치한 수질정화시설은 강우시 및 비강우시의 운전방법에 따라서 충분한 제거효율을 보이는 것으로 나타났다.

소규모 유역에서 자연방류형 단일저류지의 임계지속기간 분석 (The Analysis of Critical Duration of uncontrolled single detention facility in Small Catchment)

  • 박종영;신창동;이정식
    • 한국방재학회 논문집
    • /
    • 제5권2호
    • /
    • pp.17-28
    • /
    • 2005
  • 본 연구의 목적은 소규모 유역에서 홍수 저류시설물과 홍수 조절시설물 사이의 임계지속기간을 평가하는데 있다. 4개 소규모 유역을 통하여 수문분석을 실시하였으며, 유효우량은 NRCS 유효우량 산정방법으로 산정하였다. 홍수 저류시설물과 홍수 조절시설물의 임계지속기간은 허용방류량 고정개념을 이용하여 평가하였다. 허용방류량 고정개념을 이용한 경우 최대 저류비를 발생시키는 시간분포는 Huff 2분위 시간분포로 나타났으며, 자연방류형 단일저류지에서 홍수 조절시설물의 임계지속기간은 홍수 저류시설물의 임계지속기간과 유사한 것으로 나타났다.

분산형 저류지 생태환경복원 설계 - 신정3지구 생태환경저류지에 적용된 생태적수질정화비오톱(SSB)시스템을 중심으로 - (A Design for Ecological and Environmental Restoration of a Dispersal Detention System - a Case of Sustainable Structured wetland Biotop (SSB) System Applied to Ecological and Environmental Detention in the Housing District of Sinjeong 3-jigu -)

  • 변찬우
    • 한국환경복원기술학회지
    • /
    • 제16권1호
    • /
    • pp.181-191
    • /
    • 2013
  • The design process of ecological and environmental detention system located in the housing district of Sinjeong 3-jigu in Seoul are as follows. At stage one, a new dispersal detention was created in the neighborhood park located near the originally planned detention. From this, the amount of storage of this dispersal detention system was enlarged from $28,337m^3/d$, the initial storage amount, to $33,606m^3/d$ as the post storage amount, responsible to the amount of rainfall which happens every 100 years. In particular, the SSB (Sustainable Structured wetland Biotop) system, which was the New Excellent Technology verified by the Ministry of Environment (No. 258) was applied to enhance ecological functioning and water quality with the detention as a constructed wetland. At stage two, the treatment plans for non-point pollutant source occurred at the initial period of rain, flowing into the detention system were built for purifying the water of the retention pond at the base of the detentions, and the water-circulation system was designed at the dispersal detentions on the period of regular rainfalls. The non-point pollutant source flowing into detention site was calculated as $11,699m^3/d$ flowing down from seven small watersheds, which occurred at the initial period of rain. In particular the SSB systems improved the average efficiency of the water processing performance to BOD 60%, SS 90%, T-N 30%, T-P 60%. At stage three, the ecological network and biological diversity were strongly considered so that it brought the residents with amenity places. In particular, the dispersal detentions were successfully designed to restore the ecological habitat of endangered plant and animal species such as narrow-mouthed.

준설오니의 토량 산출 및 성분분석 (Estimation of soil Quantity and Environmental Effect on Dredged Soil)

  • 신은철;오영인
    • 한국토양환경학회지
    • /
    • 제5권2호
    • /
    • pp.13-21
    • /
    • 2000
  • 유수지는 생활하수 및 정수 처리된 하수를 바다에 방류하기 전에 하수방류가 조수의 영향으로 역류하는 것을 막기 위해 설치된 일종의 하수 저류시설이다. 본 연구에서는 현장에서 준설한 시료에 대하여 실내시험을 실시하여 유수지 하상 오니가 포함하고 있는 실토사의 적정량을 산출하였다. 또한, 준설오니를 임시 저장한 슬러지 저장 연못에서 시료를 채취하여 실내시험을 실시하여 준설용적을 산출하였다. 본 연구결과, 준설오니의 비중은 2.17∼2.29로 일반적인 점토보다 상당히 낮은 값으로, Gypsum과 유사한 값을 나타내었다. 또한, 함수율은 300∼700%의 범위를 나타내었다. 준설토로부터 물을 제거함에 따른 유실용적은 전체용적의 78.2∼87.5%의 범위로, 준설오니의 실토사 적정토량은 12.5∼21.9%의 범위를 나타내었다. 유수지 준설오니와 고화처리시료에 대한 중금속함량(크롬, 아연, 구리, 카드뮴, 수은, 비소, 납)시험결과 국내 관계법령 중 가장 엄격한 해양오염방지법 기준에 모두 만족하는 결과를 나타내었다.

  • PDF

신양천 하천수정화 연못시스템의 처리수준 및 연못반응 (Treatment Level and Reactions of a Treatment Pond System Purifying Sinyang Stream Water)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제8권6호
    • /
    • pp.1-12
    • /
    • 2005
  • Treatment level and pond reactions of a pond system were examined from May to October 2002. The system was constructed in July 2000 for purifying water of Sinyang stream that flows into Koheung Estuarine Lake located in the southern part of the Korean Peninsula. The system was composed of a primary and a secondary pond in series and established on the rice field near the lake. Water pumped from the stream was funneled into the primary pond, whose effluent was discharged into the secondary pond by gravity flow. Effluent from the secondary pond was funneled into wetlands. About 130 $m^3$/day of water was pumped into the primary pond and detention time of the primary and secondary pond was about 2 days. DO from the surface to the 1.0 m depth of the primary and secondary pond was in the rage of 5.2 to 11.0 mg/L and 4.3 to 0.7 mg/L, respectively. DO at the bottom layer of the primary pond was 0 mg/L and that of the secondary pond ranged 3.0~4.7 mg/L. The primary pond functioned as a facultative pond and the secondary as an aerobic one. The temperature difference between the surface and bottom layers of the ponds in August was about $2.5^{\circ}C$ and that in May and October was about $1.0^{\circ}C$. Thermocline was observed in the primary pond during the high ambient temperature of August. The sludge depth of the primary pond in May, August, and October was 2.4, 1.9, and 2.2 cm, respectively. That of the secondary pond was 1.2, 1.0, and 1.1 cm, respectively. SS, $BOD_5$, T-N, and T-P concentrations in influent averaged 16.64, 6.71, 6.21, and 0.23 mg/L and those in effluent from the primary pond averaged 11.48, 4.97, 4.81, and 0.17 mg/L, respectively. The removal rates of the primary pond for SS, $BOD_5$, T-N and T-P were 31%, 26%, 22%, and 24%, respectively. Average concentrations of SS, $BOD_5$, T-N, and T-P in effluent from the secondary pond were 9.81, 4.07, 4.03, and 0.14 mg/L, respectively and the abatement rates of the secondary pond for SS, $BOD_5$, T-N and T-P were 20%, 12%, 13%, and 15%, respectively. SS, $BOD_5$, T-N and T-P concentrations in effluent from the primary pond were significantly low(p=0.001) when compared with those from the secondary one.

월지 조성 목적의 중의성(重意性) 고찰 (Various Meanings of Wolji Pond Construction in Shilla Dynasty)

  • 홍광표
    • 한국전통조경학회지
    • /
    • 제34권3호
    • /
    • pp.67-77
    • /
    • 2016
  • 본 연구는 월지의 조성목적이 단순히 정원을 조성하기 위해서라는 기존의 이론에 대한 문제제기로부터 시작되었다. 본 연구에서는 월지조성에 대한 기존의 이론에 대하여 논의한 후, 월지조성의 또 다른 목적을 저류지로 상정하고 이것에 대하여 검증하였다. 연구결과는 다음과 같다. 첫째, 월지조성에 대하여 제기한 두 가지 의문에 대하여 논의한 결과 월지가 처음부터 정원으로 만들어졌을 가능성 보다는 저류지로서 조성하였을 것이라는 가능성을 진단하였다. 둘째, 위치와 지형적 측면으로 볼 때, 월지는 북천으로부터 유입된 물이나, 범람한 물, 또는 용출수가 형성하는 지천이나 수로가 자연스럽게 월지 쪽으로 흐르도록 지형적 조건이 형성되어 있으며, 월지는 이렇게 형성된 물이 남천으로 유입되는 유로의 종점에 위치하고 있어 물을 저류한 후 유출하기에 유리한 조건을 갖추고 있다는 것을 확인하였다. 셋째, 수리적 측면에서 볼 때, 북천은 제방이 축조되기 이전에는 범람이 일어날 가능성이 상존하였으며, 이러한 홍수피해는 구황동원지에서 한번, 다시 월지에서 한번 잡아주어 왕경중심부로 피해가 확산되지 않도록 하였던 것으로 보인다. 넷째, 도시계획적 측면에서 볼 때, 월지가 조성되기 이전에 월지일대는 도시기능이 들어서지 않았다는 것을 확인하였으며, 월지가 조성되고 난 이후에 도로 등의 개설을 통해 도시계획이 완성되었다는 것을 확인하였다. 다섯째, 월지의 입수장치와 출수장치 그리고 월지 서측의 수직석단은 월지가 저류지로서의 기능을 충분히 할 수 있도록 한 시설이었다는 것을 확인하였다. 여섯째, 저류용량으로 볼 때, 월지는 당시로서는 엄청난 량의 물을 저류할 수 있는 시설이었다는 것을 확인하였다.

도시유출해석을 위한 도시수문 모니터링 기법 적용 (Application of Urban Hydrologic Monitoring System for Urban Runoff Analysis)

  • 서규우
    • 한국방재학회 논문집
    • /
    • 제5권2호
    • /
    • pp.37-44
    • /
    • 2005
  • 본 연구의 대상유역인 동의대 시험유역은 공간적으로 주위가 산의 능선으로 둘러싸여 유역내의 유출은 거의 대부분 단일 유출구로만 유출이 이루어지며, 부산지방의 도시유역의 특징인 경사지형의 특성을 잘 반영하고 있다. 유역기초자료 및 기상관측장비(EMS)와 자동수위관측장비(AWS)를 통해 수집된 각종 수문자료들과 유역상세자료들을 조사하여 ILLUDAS 모형과 SWMM 모형, HEC-HMS 모형의 기본입력자료로 사용하여 시험유역 유출특성을 검토하고, HEC-HMS 모형에 대한 검정 및 검증을 통해 시험유역 저류지설계에 사용한다. HEC-HMS 모형에 소하천 설계기준인 30년 설계강우를 설정하고 불투수율의 변화양상에 따라 설계홍수량을 산정하고, 유출누가곡선상에서 저류지의 용량을 결정하였다. 시험유역의 최종 유출부 상류에 $54,000m^3$의 가상 저류지를 설계하였고, 저류지 설계 후 유출양상을 검토해본 결과 유출의 첨두량이 감소함을 확인할 수 있었다. 이는 저류지설계로 도시지역의 유출이 감소됨으로서 도시홍수방재에 있어서 적용성이 있음을 확인할 수 있었다.

생태적 축산폐수 처리 및 재활용 연못시스템의 폐수처리수준 (Treatment Level of a Pond System for Ecological Treatment and Recycling of Animal Excreta)

  • 양홍모;이종욱
    • 한국환경농학회지
    • /
    • 제17권1호
    • /
    • pp.70-75
    • /
    • 1998
  • 실험결과 최종처리수의 $BOD_5$를 30mg/l 이하로 유지하는 것이 충분히 가능하다. 최종처리수의 총질소와 총인은 축산폐수처리시설의 방류수 수질기준보다 월등히 낮다. 연못상층에서 조류(Algae)가 성장하면서 질소와 인을 흡수하기 때문이다. 연못시스템은 질소와 인을 동시에 제거하는 장점이 있다. 최종처리수의 평균 SS가 $30mg/{\ell}$ 보다 다소 높아 2차처리 수준의 방류수 수질기준을 충족시키지 못하는 경우가 발생할 수 있으나 연못상층의 조류(Algae) 성장에 원인이 있어 문제가 되지 않는다. 2차연못과 3차연못의 SS는 거의 조류가 차지하고 있다. 조류를 회수하여 사료로 사용하거나 처리수를 유기농업 관수로 이용하여 조류를 비료로 이용하는 재활용 방법이 바람직하다. 실험 연못시스템의 모델은 연못의 수, 연못의 종류, 각 연못의 크기, 유입폐수의 $BOD_5$ 부하량을 적절히 조절하면 액상폐수(뇨${\cdot}$오수)뿐아니라 분${\cdot}$${\cdot}$오수를 동시에 처리할 수 있다. 국내 여건에서는 중소규모 축산시설의 폐수를 처리하는데 연못시스템이 적합하며, 토지확보가 가능하면 대형 축산폐수 공동처리시설로 사용할 수 있다. 대부분 축산농가에 설치되어 있는 간이정화조와 산화구를 연못시스템으로 대치하여 이들의 낮은 처리효율의 문제점을 해결할 수 있다고 사료된다. 다른 처리기법에 비해 연못시스템은 관리운영에 적은 인력과 경비가 소요하여 노동력이 부족한 농촌지역에 적합하다.

  • PDF