• Title/Summary/Keyword: detention

Search Result 303, Processing Time 0.025 seconds

A Study on Gathering Behaviour of Fish in the Artificial Sea-floor Area (인공해저에 대한 어류의 위집기구에 관한 연구)

  • 홍성완
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.2
    • /
    • pp.96-104
    • /
    • 2000
  • By using the offshore type submersible platform, Artificial sea floor anchored at a depth of forty meters several experimental studies have been conducted successfully during 1996. The facility consists of an artificial sea floor that floats at 7 meters below the surface, a machinery hut that projects above the surface at the center of the structure and a balance weight beneath the structure. The facility can be surfaced easily by using a water discharging pump in the water tank which is located at the center of it. To find out the behavioral character and the gathering factor of fishes around the artificial sea floor, investigations were carried out during the daytime and nighttime by direct observation and by echo-sounder. Around the testing reefs and artificial sea floor, six kinds of fishes were found by diving observation and the dominants were Scomber japonicus, Sebastes thompsoni and Oplegnathus fascitus. As Scomber japonicus was distributed around the artificial sea floor in dense small school, they were not seen elsewhere in the survey area. The artificial sea floor was concluded to act as a schooling ground far Scomber japonicus, Sebastes thompsoni and Oplegnathus fascitus. were close to the testing reefs(within 10m) in the daytime, and were thought to settle on the testing reefs at nighttime, To examine the distribution of 7shes around the artificial sea floor, an acoustic survey over a 1$\times$1km area, 0-50m in depth during the all day. Around the artificial sea floor many thin scattering fish echo(TS-54.5~ -51.5dB) and dense fish echo(TS-41~-38dB) were mainly distributed. Many scattering fish echoes, which were thought to be a mixture of small squid, pelegic crustacea and ethers, were distributed over the whole survey area. A dense fish school stayed beneath the artificial sea floor for a short duration. These phenomena were concluded to show an attraction and detention function of the artificial sea floor.

  • PDF

Development of a Water Sampling System for Unmanned Probe for Improvement of Water Quality Measurement (수질측정 방법 개선을 위한 무인 탐사체의 채수장치 개발방안)

  • Jung, Jin Woo;Cho, Kwang Hee;Kim, Min Ji
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.6
    • /
    • pp.527-534
    • /
    • 2017
  • The purpose of this study is to develop unmanned equipment that can automatically move to the desired point and measure water quality at the correct depth. For this purpose, we constructed a water sampling lift and water sampling container, an unmanned vessel equipped with a VRS-GPS, an acoustic echo sounder, and a water quality sensor. Also, we developed an automatic navigation algorithm and program, an automatic water sampling program, and a water quality map generation program. As a result of the experiment in the detention pond, the unmanned vessel sailed along the planned route with an accuracy of about 93% within the error range of 3m. In addition, the water quality sensor installed in the lift was able to acquire the water quality of the target area in real time and transmit it to the server via wireless Internet, and it was possible to monitor the water quality of each site in real time. Through field experiments, the water sampling lift was able to control the desired length with an accuracy of about 94%. The stretch length accuracy experiment of the water sampling lift was impossible to measure directly in the water, so it was replaced land-based experiment. We also found some unstable problems due to the weight of the water sampling lift and the weight of the air compressor to operate the water container. Except these two problems, we accomplished purpose of this study. An automated water quality measurement method using an unmanned vessel can be used to measure the quality of water in a difficult to access area and to secure the safety of the worker.

Analysis of Water Quality Characteristics Using Simulated Long-Term Runoff by HEC-HMS Model and EFDC Model (HEC-HMS 모형에 의한 장기유출량과 EFDC 모형을 이용한 호소 내 수질특성 분석)

  • Kim, Yon-Soo;Kim, Soo-Jun;Kim, Hung-Soo
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.707-720
    • /
    • 2011
  • For the lake case, the detention phenomenon of water body occurs and stays for a long time. Especially, following the layer of water depth direction, the lake body and water quality problems are different from the water quality of river. So according to time, the stream and water quality can be simulated by the 3-Dimensional Model, which can divide water layer for reservoir or lake. The water quality simulation result will become more reliability. For this study, the 3-Dimension Model - EFDC was used to simulate water quality of Unam reservoir in the Sumjin Dam. The HEC-GeoHMS and HEC-HMS Rainfall - Runoff Model based on GIS were used to estimate long-term runoff, and input data was constructed to the observed water level, meteorological data, water temperature, T-N and T-P. In order to apply the EFDC model, water depth was divided into 3 layers and 5,634 grids were extracted. After constructing the grid net, the water quality change of Unam reservoir in time and space was simulated. Overall, long term runoff simulation reflected the actual observed runoff well, through the water quality simulation, according to the pollution factors, the behavior characteristics can be checked, and the simulated water quality can be properly reflected. The function of EFDC has been confirmed, which water quality can be properly simulated. In the near future, to establish countermeasures for Intake Facilities of Watershed and Management, this support which some basic tools can be applied is in expectation.

An approximate study on flood reduction effect depending upon weir or gate type of lateral overflow structure of washland (강변저류지 월류부에서 월류제 또는 수문 형식에 따른 홍수저감효과에 관한 개략적 연구)

  • Ahn, Tae Jin
    • Journal of Wetlands Research
    • /
    • v.15 no.4
    • /
    • pp.573-583
    • /
    • 2013
  • Construction of large-scale structures such as dams would be suggested actively to cope with change of flood characteristics caused by climate change. However, due to environmental, economic and political issues, dams are not ideally constructed. Thus flood damage reduction planning projects would get started including washland or detention pond for sharing the flood in basin. The washland made artificially by human being is an area of floodplain surrounded by bank to be intentionally inundated by overflowing through overflow structure adjacent to main channel during flood season. Flood reduction capacity at just downstream of each washland could be affected by type, length, and crest elevation of overflow structure in addition to shape of design hydrograph, storage volume of washland, etc.. In this study flood reduction effects of washland are estimated for overflow weir type and gate type to compare the results of flood reduction respectively subjected to given hydrograph in sample site, the Cheongmicheon stream. It has been shown that even if gate type at overflow structure could yield more flood reduction than overflow weir type, economic aspect such as initial cost, operation cost and maintenance cost should be considered to select the type of overflow structure because flood reduction rate by gate type could not be significant value from engineering point of view.

A Study on Adjustment of Operational Factor in A2O process (A2O공정 운전인자 조정에 대한 연구)

  • Yoo, Ho-Sik;Lee, Byonghi
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.3
    • /
    • pp.33-41
    • /
    • 2015
  • An alternative was investigated to maximize the treatment efficiency of wastewater treatment plant without large scale expansion. 79% of detention time was required for enough nitrogen control. As aeration time was extended, nitrification was processed, but opposite trend was seen in phosphorus. High concentration of $NO_3-N$ interrupted PAOs activity not to absorb phosphorus. An alternative was devised for selective use of anaerobic or anoxic zone. Trisection was suggested for alternative use of center room. The result was relatively successful. The concentration of phosphorus was reduced with reduction of nitrogen. Extended anaerobic condition seemed to stimulate denitrification. Valve connection of internal return from aeration tank will make it possible to use middle room alternatively. This method will be a good alternative for seasonal variation of water temperature.

A Study of the Summary Trial System's Reform Measures (현행 즉결심판제도의 개선방안 연구)

  • Kwak, Young-Kil
    • Korean Security Journal
    • /
    • no.13
    • /
    • pp.47-70
    • /
    • 2007
  • The criminal procedure is based upon two ideal values, or 'speedy trial and economy of litigation' and 'finding truth and guarantee of human rights', which are conflicting each other. The so called summary trial system, a simplified procedure through which a judge handles clearly obvious and minor offences in a quick and efficient manner, has its essential purpose of termination lawsuits promptly and freeing suspects or defendants from criminal procedure at the earliest possible moment. But its excessive emphasis on this purport is very likely to result in insufficient examination and inadequate protection of suspects' or defendants' rights. Therefore, the summary trial system needs a variety of safeguards to prevent these feasible - but undesirable - effects. From this point of view, we should objectively review the current summary trial system. The main object of this study is to investigate what problems the system has both in institution and in practice, and to suggest legal measures, including the abolition of it, to improve the simplified procedure. In conclusion, the summary trial system should be maintained because it has still more merits than faults. And these defects will be able to be overcome by reform measures ; for example, the introduction of the right to opt between the summary procedure and the formal trial, the abolition of detention and so on.

  • PDF

Analysis of Hydraulic Characteristics for the Design Parameters of Culvert Outlet Facilities in Detention Pond (저류지 암거방류시설 설계인자의 수리학적 특성 분석)

  • Lee, Jae Joon;Jang, Joo Young;Lee, Hoo Sang;Jang, Hyun Min
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.213-213
    • /
    • 2011
  • 근래 이상기후에 의한 강우량 증대와 도시화에 따른 첨두유출량의 증대 및 도달시간의 단축은 기존의 유수지만으로 도시홍수를 대처하는데 그 한계점에 다다르게 되었다. 1990년대에 들어 각종 우수유출 저감시설의 활용으로 이상의 문제를 해결하고자 하는 노력들이 시작되었으며, 현재 신규개발지에 저류지와 같은 우수유출저감시설 설치를 법제도적으로 의무화 하고 있어, 전국적으로 천여개소의 저류지가 시설되어 있거나 계획 중에 있다. 저류지는 개발로 인해 증가된 첨두유출량을 개발전의 상태로 저감시키기 위하여 임시 또는 상시 저류하거나 저류능력 이상의 유출량에 대해서는 암거방류시설을 통해 하류부의 하천 또는 하도로 방류시키는 역할을 수행하는 수공구조물로서 일반적으로 저류지 계획 및 설계는 첨두유출량 증가분에 대해 초점을 맞추고 있을 뿐 방류시설에 대한 구체적인 설계는 이루어지지 않고 있는 실정이다. 또한 현재 국내에는 저류지 방류시설로 주로 사용되는 암거에 관한 설계규정이나 기법은 미미한 상태로, 한국도로공사(1991)에서 발표한 "도로배수계획"을 이용하고 있으며, 이는 미국 연방도로국(FHWA, 1985)에서 발표한 설계기법을 그대로 인용하고 있다. 즉, 지형 또는 현장 여건에 따라 암거 흐름의 8형식 중 하나의 형식으로 결정하고, 그 형식에 따라 관련도표를 이용한 시산법 또는 도식해법을 적용하여 유입부 상류수위를 산정함으로써 암거설계가 이루어진다. 하지만 이러한 암거설계 방식은 도로 배수암거에 적합한 것으로 저류지 배수암거에 적용하기에는 무리가 있다고 본다. 따라서, 본 연구에서는 저류지의 일반적인 특성상 암거흐름 8형식 중 Class-II군의 암거 상류부 수위가 잠수된 조건 즉, 평상시 저류지가 일정수위 이상의 저류량을 유지하고 있는 상태에서 저류지 암거방류시설의 대표적인 설계인자인 암거직경, 암거경사, 암거경사, 하류단 수위조건의 변화에 따른 상류부 수위변화를 유량별로 분석해 보았다. 방류 암거의 개수를 고려하기 위하여 암거상류부 수위와 암거직경의 관계해석 시 암거단면적을 이용하여 분석하였으며, 각각의 유량별로 상류부 수위와 암거단면적의 관계를 회귀식으로 제시하였다. 암거상류부 수위와 암거경사의 관계를 분석한 결과 암거경사가 5~20%로 변화할 때 암거상류부 수위의 변화는 2~5%정도의 매우 작은 변화를 보임을 확인할 수 있었으며, 암거길이의 경우는 해석 조건의 특성상 상류부 수위에 영향이 전혀 나타나지 않았다. 암거상류부 수위와 암거하류단 수위의 관계에서 암거상류부 수위는 암거하류단 수위가 암거직경과 퇴사위 높이의 합보다 암거하류단의 수위가 높아지는 시점부터 암거하류단 수위에 비례해서 증가되는 결과를 알 수 있었다.

  • PDF

A Study on Development of Safety Management Evaluation Index for Shipping Company (해운선사 안전관리 평가지표 개발에 관한 연구)

  • Kim, Hwa-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.6
    • /
    • pp.629-636
    • /
    • 2013
  • There is no safety evaluation index with marine accidents and information of ship's safety management result for good grasp of safety management level of shipping company and effective monitoring. In this paper, we proposed a SMEI(Safety Management Evaluation Index) for evaluation of shipping companies. The SMEI is consist of MAR(marine accidents ratio), SSMR(ship safety management ratio) and SAP(safety advantage point) through brainstorming of the expert group and AHP(analysis hierarchy process)in previous study. And weights of SMEI are calculated using experts's opinions through the Delphi method. We also verified the validity of proposed SMEI to 119 Korean shipping companies with 916 ocean-going ships of Korean flag, which grouped three part (small, mid and big) by number of ship and gross tonnage. And we found out 19 shipping companies, 8 companies in group1 & group2 respectively and 3 companies in group 3, with score below 1.0 by SMEI. In these companies, there are no marine accidents in recent 3 years and appeared low frequency remarkably in the detention and mojor non-conformity by data analysis.

Improvement and Application of Pump Station Operating System and Economic Analysis of the Application (빗물펌프장 운영시스템 개선 및 적용과 경제효과분석)

  • Joo, Jin- Gul;Yoo, Do-Guen;Yang, Jae-Mo;Jung, Dong-Hwi;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • In low-lying districts of urban areas, pump stations were built to protect flooding by the heavy rain. Particularly, the automatic pump operation system was installed for efficiency in the pump stations of Seoul. However, the effective pump operation is difficult under existing operating system because the system only performs operation by reservoir depth. This study would like to improve the real time operating system suggested by Jun et al.(2007) and to apply the system Gasan 1 pump station in Seoul. For various design rainfall events, maximum water levels simulated by the suggested system were 10~70cm lower than results by the existing system. And overflow volume at upstream manholes were 50% reduced. We converted the flood control effects by establishment of the suggested system to economic indicators. To obtain the same effect, approximately 4.9 billion won needs to expand pump capacities or 3.2~6.9 hundreds million won needs to construct storm water detention on upstream area. The suggested system could improve the flood control stability by efficient operation of the existing pump station.

A Study on Degradation of Nitrogen Compounds by Biofilm Reactor Packed with Porous Media (다공성 담체를 이용한 생물막 반응조의 질소화합물 분해에 관한 연구)

  • Cho, Hae-Mi;Kim, So-Yeon;Yoon, Ji-Hyun;Han, Gee-Bong
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.776-780
    • /
    • 2007
  • A biofilm reactor packed with porous media was investigated for nitrogen removal of synthetic wastewater. The effect of different loading rates on the nitrification was sustained to be steady state with stable efficiency of 50~60% in the range of $0.0083{\sim}0.017gNH_4-N/gMLVSS{\cdot}day$ of F/MN ratio and $1{\sim}2kgNH_4-N/m^3{\cdot}day$ of media volumetric loading rate. However, nitrification efficiency was rapidly decreased to 25~30% as F/MN ratio and media volumetric loading rate were increased to the range of $0.025{\sim}0.034gNH_4-N/gMLVSS{\cdot}day$ and $3{\sim}4kgNH_4-N/m^3{\cdot}day$, respectively. Also the consumption rate of alkalinity was higher under 8 hours of HRT than unter 6 hours of HRT. Accordingly the influent loading rate variation by detention time with influent flow influenced more on the nitrification efficiency than the influent loading rate variation by the influent concentration did. The temperature effect on the nitrification showed 25% higher in summer than in winter as the results reported by other researchers who reported that the nitrification efficiency in biofilm showed 20% increase from 55% to 75% when the temperature was raised from $20^{\circ}C$ to $25^{\circ}C$. Denitrification with sulfur-media showed 90% removal efficiency under steady-state with no effect from the increase of influent concentration and empty bed contact time (EBCT) change such as EBCT was decreased from 8.4 hr to 4.3 hr and $NO_3-N$ loading rate was changed within the range of $0.1{\sim}0.4kgNO^3-N/m^3{\cdot}day$. Accordingly Denitrification with sulfur-media is feasible for post denitrification at the concentration less than $80mgNO^3-N/L$.