• Title/Summary/Keyword: detector peptides

Search Result 5, Processing Time 0.019 seconds

Roles of the Peptide Transport Systems and Aminopeptidase PepA in Peptide Assimilation by Helicobacter pylori

  • Ki, Mi Ran;Lee, Ji Hyun;Yun, Soon Kyu;Choi, Kyung Min;Hwang, Se Young
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.10
    • /
    • pp.1629-1633
    • /
    • 2015
  • Peptide assimilation in Helicobacter pylori necessitates a coordinated working of the peptide transport systems (PepTs) and aminopeptidase (PepA). We found that H. pylori hydrolyzes two detector peptides, L-phenylalanyl- L-3-thiaphenylalanine (PSP) and L-phenylalanyl- L-2-sulfanilylglycine (PSG), primarily before intake and excludes their antibacterial effects, whereas Escherichia coli readily transports them with resultant growth inhibition. PSP assimilation by H. pylori was inhibited by aminopeptidase inhibitor bestatin, but not by dialanine or cyanide-m-chlorophenylhydrazone, contrary to that of E. coli. RT- and qRT-PCR analyses showed that H. pylori may express first the PepTs (e.g., DppA and DppB) and then PepA. In addition, western blot analysis of PepA suggested that the bacterium secretes PepA in response to specific inducers.

Characteristics of Peptide Assimilation by Helicobacter pylori: Evidence for Involvement of Cell Surface Peptidase

  • YUN SOON-KYU;CHOI KYUNG-MIN;UHM CHANG-SUB;PARK JEONG-KYU;HWANG SE-YOUNG
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.4
    • /
    • pp.899-902
    • /
    • 2005
  • Peptide assimilation by Helicobacter pylori was investigated using L-phenylalanyl-3-thia-phenylalanine (PSP) as a detector peptide; the release of thiophenol upon enzymatic hydrolysis of PSP was spectrophotometrically detected with the aid of 5,5'-dithiobis[2-nitrobenzoic acid] (DTNB). By adding PSP to whole-cell suspension, thiophenol was produced progressively, resembling that found in Esherichia coli or Staphylococcus aureus. Interestingly, the rate of thiophenol production by H pylori in particular was markedly reduced when cells were pretreated with trypsin, indicating surface exhibition of peptidase. According to the competitive spectrophotometry using alanyl-peptides, H pylori did not appear to assimilate PSP through the peptide transport system. No discernible PSP assimilation could be ascertained in H pylori cells, unless provided with some additives necessary for peptidase activity, such as $Ni^{2+}\;or\;Mg^{2+}$ and an appropriate concentration of potassium or ammonium salts. These observations strongly suggest that, regardless of a presumptive peptide transport system, peptide assimilation of H. plori appears to be highly dependent upon milieu conditions, due to unique peptidase exhibition on the cell surface.

Stability Test and Quantitative and Qualitative Analyses of the Amino Acids in Pharmacopuncture Extracted from Scolopendra subspinipes mutilans

  • Cho, GyeYoon;Han, KyuChul;Yoon, JinYoung
    • Journal of Pharmacopuncture
    • /
    • v.18 no.1
    • /
    • pp.44-55
    • /
    • 2015
  • Objectives: Scolopendra subspinipes mutilans (S. subspinipes mutilans) is known as a traditional medicine and includes various amino acids, peptides and proteins. The amino acids in the pharmacopuncture extracted from S. subspinipes mutilans by using derivatization methods were analyzed quantitatively and qualitatively by using high performance liquid chromatography (HPLC) over a 12 month period to confirm its stability. Methods: Amino acids of pharmacopuncture extracted from S. subspinipes mutilans were derived by using O-phthaldialdehyde (OPA) & 9-fluorenyl methoxy carbonyl chloride (FMOC) reagent and were analyzed using HPLC. The amino acids were detected by using a diode array detector (DAD) and a fluorescence detector (FLD) to compare a mixed amino acid standard (STD) to the pharmacopuncture from centipedes. The stability tests on the pharmacopuncture from centipedes were done using HPLC for three conditions: a room temperature test chamber, an acceleration test chamber, and a cold test chamber. Results: The pharmacopuncture from centipedes was prepared by using the method of the Korean Pharmacopuncture Institute (KPI) and through quantitative analyses was shown to contain 9 amino acids of the 16 amino acids in the mixed amino acid STD. The amounts of the amino acids in the pharmacopuncture from centipedes were 34.37 ppm of aspartate, 123.72 ppm of arginine, 170.63 ppm of alanine, 59.55 ppm of leucine and 57 ppm of lysine. The relative standard deviation (RSD %) results for the pharmacopuncture from centipedes had a maximum value of 14.95% and minimum value of 1.795% on the room temperature test chamber, the acceleration test chamber and the cold test chamber stability tests. Conclusion: Stability tests on and quantitative and qualitative analyses of the amino acids in the pharmacopuncture extracted from centipedes by using derivatization methods were performed by using HPLC. Through research, we hope to determine the relationship between time and the concentrations of the amino acids in the pharmacopuncture extracted from centipedes.

Comparison between Source-induced Dissociation and Collision-induced Dissociation of Ampicillin, Chloramphenicol, Ciprofloxacin, and Oxytetracycline via Mass Spectrometry

  • Lee, Seung Ha;Choi, Dal Woong
    • Toxicological Research
    • /
    • v.29 no.2
    • /
    • pp.107-114
    • /
    • 2013
  • Mass spectrometry (MS) is a very powerful instrument that can be used to analyze a wide range of materials such as proteins, peptides, DNA, drugs, and polymers. The process typically involves either chemical or electron (impact) ionization of the analyte. The resulting charged species or fragment is subsequently identified by the detector. Usually, single mass uses source-induced dissociation (SID), whereas mass/mass uses collision-induced dissociation (CID) to analyze the chemical fragmentations Each technique has its own advantages and disadvantages. While CID is most effective for the analysis of pure substances, multiple-step MS is a powerful technique to get structural data. Analysis of veterinary drugs ampicillin, chloramphenicol, ciprofloxacin, and oxytetracycline serves to highlight the slight differences between SID and CID. For example, minor differences were observed between ciprofloxacin and oxytetracycline via SID or CID. However, distinct fragmentation patterns were observed for ampicllin depending on the analysis method. Both SID and CID showed similar fragmentation spectra but different signal intensities for chloramphenicol. There are several factors that can influence the fragmentation spectra, such as the collision energy, major precursor ion, electrospray mode (positive or negative), and sample homogeneity. Therefore, one must select a fragmentation method on an empirical and case-by-case basis.

Levels of common salivary protein 1 in healthy subjects and periodontal patients

  • Heo, Seok-Mo;Lee, Sol;Wang, HongTao;Jeong, Jeong Hyeok;Oh, Sang Wook
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.5
    • /
    • pp.320-328
    • /
    • 2016
  • Purpose: Human saliva, as a vital part of the immune defense system, contains a number of distinct proteins and peptides. Recently human common salivary protein 1 (CSP1) has been identified as an abundant salivary protein and may play a role in promoting the binding of cariogenic bacteria to salivary pellicles. However, nothing else is known regarding the role of CSP1 in periodontology. The aim of this study was to quantify and compare CSP1 levels between healthy subjects and periodontal patients. Methods: This controlled clinical study was conducted in periodontally healthy individuals and patients with chronic periodontitis Chonbuk National University Hospital, with Institutional Review Board approval. Whole saliva samples were collected from 36 healthy subjects and 33 chronic periodontitis patients and analyzed. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis and immune blotting were conducted to ensure that anti-CSP1 monoclonal antibody (mAb) binds to CSP1 in human saliva. A sandwich enzyme-linked immunosorbent assay (ELISA) system was house-fabricated using mAb-hCSP1#14 and mAb-hCSP1#4 as a capture and a detector mAb, respectively. The CSP1 concentrations in saliva from 36 healthy subjects and 33 periodontal patients were quantified using the CSP1 sandwich ELISA system, and the results were analyzed using the Student's t-test. Results: Immunoblot analysis using mAb-hCSP1 as a probe confirmed that CSP1 in human saliva existed as a single band with a molecular weight of approximately 27-kDa. The quantification of CSP1 concentrations by CSP1 ELISA showed that the median values (25th to 75th percentiles) of periodontal patients and healthy subjects were 9,474 ng/mL (range, 8,434.10,139 ng/mL) and 8,598 ng/mL (range, 7,421.9,877 ng/mL), respectively. The Student's t-test indicated the presence of a statistically significant difference between the 2 groups (P=0.024). Conclusions: The presence of a significant difference in CSP1 levels between healthy subjects and periodontal patients suggests that CSP1 may be a potential biomarker for the detection or screening of periodontitis patients.