• 제목/요약/키워드: detector

검색결과 6,157건 처리시간 0.037초

Development of Analytical Model for Optimization of Dual Layer Phoswich Detector Length for PET

  • Chung Yong Hyun;Choi Yong;Choe Yearn Seong;Lee Kyung-Han;Kim Byung-Tae
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권1호
    • /
    • pp.17-22
    • /
    • 2005
  • Small animal PET using a dual layer phoswich detector has been developed to obtain high and uniform spatial resolution. In this study, a simple analytic model to optimize the lengths of a dual layer phoswich detector was derived and validated by Monte Carlo simulation. For a small animal PET scanner with a 10㎝ ring diameter, the optimal length of the phoswich detector consisting of various crystal materials, such as LSO and LuYAP, were calculated analytically and validated using GATE. The detector module consisted of 8×8 arrays of crystals, with each phoswich detector element having a 2㎜×2㎜ sensitive area. The total crystal length was fixed to 20㎜. The optimal lengths of the phoswich detector layers, as functions of the crystal materials and order, conveniently derived by the analytic equation, showed good agreement with those estimated by the time consuming simulation. The simple analytical model can be used for the fast and accurate design of an optimal phoswich detector for small animal PET to achieve high spatial resolution and uniformity.

소급성과 신뢰구간 개념을 적용한 개별차량단위 검지기 성능평가 (Individual Vehicle Level Detector Evaluation with Application of Traceability and Confidence Interval Concepts)

  • 장진환;최동원
    • 한국ITS학회 논문지
    • /
    • 제13권5호
    • /
    • pp.11-20
    • /
    • 2014
  • 실시간 교통정보는 현장에 설치된 차량검지기가 수집하는 교통량, 속도, 점유율 자료를 기반으로 생성된다. 따라서 검지기 성능을 일정수준으로 유지시키는 것이 중요하다. 이를 위해 ITS 관리기관에서는 주기적으로 검지기에 대한 성능평가를 수행한다. 일반적으로 검지기 성능평가는 기준값을 생성하는 장비(기준장비)와 평가대상 검지기가 수집하는 자료를 상호 비교함으로써 수행된다. 여기서 유의할 점은 기준장비 수집값 역시 평가대상 검지기 자료와 같이 오차 및 불확도를 포함하고 있다는 것이다. 또한 검지기 평가가 표본집단에 대해 이루어지기 때문에 이를 모집단의 결과로 표현하기 위해서는 신뢰구간 개념이 적용되어야 한다. 그러나 현재 국내 검지기 성능평가는 합리적인 방법론 부재로 인해 기준값 불확도 및 신뢰구간 개념을 적용하지 않고 있다. 따라서 본 연구에서는 기준값 불확도 및 신뢰구간 개념을 적용한 성능평가 방법론을 제시했고, 이를 루프, 영상, 레이더 검지기 성능평가에 적용했다. Over-count, Under-count 상쇄효과를 제거하기 위해 개별차량단위 자료를 평가하였고 그 결과, 제시된 방법론이 검지기 성능평가에 효과적으로 적용될 수 있음을 입증하였다.

요중 알파나프틸아민 분석에 관한 연구 (The study on the analysis of α-naphthylamine in urine)

  • 김춘성;노재훈;배문주;김치년;임남구;원종욱
    • 한국산업보건학회지
    • /
    • 제7권1호
    • /
    • pp.49-59
    • /
    • 1997
  • This study was performed to analyze the purity of technical grade ${\alpha}$-naphthylamine, to establish optimal analytical condition of ${\alpha}$-naphthylamine in urine and to determine the urine sample of workers exposed to ${\alpha}$-naphthylamine. The purity of technical grade ${\alpha}$-naphthylamine were $96.5{\pm}2.38%$, $94.1{\pm}0.97%$, $97.0{\pm}0.02%$ by gas chromatography-mass selective detector. To analyze ${\alpha}$-naphthylamine in urine, high performance liquid chromatography-electrochemical detector and gas chromatography-electron capture detector operating conditions have been optimized by preliminary expriment. In high performance liquid chromatography-electrochemical detector, the mobile phase was consisted of acetonitrile(35%) and water(65%), and the flow rate was maintained at 1.0ml per minute. Optimal detective condition was 9.0V(10nA/V) of electrochemical detector. The recovery of sep-pak treatment method was highly estimated as pretreatment of ${\alpha}$-naphthylamine in urine. The free amine was isolated by gas chromatography-electron capture detector after basic hydrosis, sep-pak treatment, toluene elution and HFBA(heptafluoro-butyric anhydride) derivatization of urine. The recovery of ${\alpha}$-naphthylamine in urine was $98.73{\pm}3.29%$ by gas chromatography-electron capture detector. The sensitivity was more higher than that of high performance liquid chromatography-electrochemical detector. Urinary ${\alpha}$-naphthylamine was detected in only one worker among nine workers. The level of ${\alpha}$-naphthylamine in urine was 6.42 ng/ml.

  • PDF

금속-절연체 전이 임계온도센서를 이용한 보상식 화재 감지기 개발 (Development of Compensation-Type Fire Detector Using Metal-Insulator-Transition Critical-Temperature Sensor)

  • 정순규;김현탁
    • 한국화재소방학회논문지
    • /
    • 제28권1호
    • /
    • pp.26-30
    • /
    • 2014
  • 보상식 화재 감지기는 일정한 온도 상승률 이상으로 빠르게 상승하는 경우에 작동하는 차동식 화재 감지기의 기능과 정온점에 이르렀을 때 작동하는 정온식 화재 감지기의 기능을 모두 가진 감지기다. 이 화재 감지기는 정온점 이하에서 발생하는 화재를 감지하지 못하는 정온식 화재 감지기의 단점과 불꽃없이 천천히 타는 현상과 같이 천천히 열이 증가하는 화재를 감지하지 못하는 차동식 화재 감지기의 단점을 보완하기 위해 개발된다. 이것을 위해 우리는 이 감지기의 센서로 금속-절연체 전이 임계온도센서를 이용했는데 이 센서의 감도를 결정하는 저항온도계수가 $55^{\circ}C$일 때 14.15%로써, 서미스터(약 0.5%)보다 큰 값이다. 이 센서는 하나의 센서가 정온점 이하에서는 차동 기능, 정온점 이상에서는 정온 기능을 모두 가진다.

이동통신을 위한 FSK동기 및 변복조기술에 관한 연구 I부. FSK 복조를 위한 Quadrature Detector 설계 (A Study on the FSK Synchronization and MODEM Techniques for Mobile Communication Part I :Design of Quadrature Detector for FSK Demodulation.)

  • 김기윤;최형진
    • 대한전자공학회논문지TC
    • /
    • 제37권3호
    • /
    • pp.1-8
    • /
    • 2000
  • 본 논문에서는 현재 이동통신 시스템의 한 형태로 단말기의 하드웨어 구현이 간단하고 IC제작이 경제적 이어서 무선호출시스템 등에 많이 사용되고 있는 FSK 신호 복조를 위한 Quadrature Detector의 디지털 시뮬레이션 모델을 구현하였다. Quadrature Detector는 아날로그 소자로서 입력신호의 주파수에 따라 다른 위상 변화값이 비선형적으로 출력되어 지금까지 시뮬레이션을 통한 정확한 시스템 특성 분석이 어려웠었다. 이에 본 논문에서는 Quadrature Detector를 이용한 FSK 신호의 복조과정을 전개하고 디지털 시뮬레이션 을 수행하여 최적 성능을 도출하였다. 먼저 Quadrature Detector의 시뮬레이션을 위해 RLC 탱크회로 (Tank Circuit)로 구성된 PSN(Phase Shift Network)의 아날로그 전달함수를 First Order Hold 이론을 이용하여 디지털 전달함수로의 등가변환을 유도하였다. 또한 4FSK신호에 대한 Quadrature Detector의 복조신호 출력 형태가 4-level 신호인데, 이를 2개의 비교기(Comparator)만을 사용할 경우 최적 성능을 얻기 위한 임계레벨 결정과 동작 파라메터 Q값 설정방법을 제안하였으며 BER 분석을 통해 검증하였다

  • PDF

Feasibility Study of Beta Detector for Small Leak Detection inside the Reactor Containment

  • Jang, JaeYeong;Schaarschmidt, Thomas;Kim, Yong Kyun
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.154-159
    • /
    • 2018
  • Background: To prevent small leakage accidents, a real-time and direct detection system for small leaks with a detection limit below that of existing systems, e.g. $0.5gpm{\cdot}hr^{-1}$, is required. In this study, a small-size beta detector, which can be installed inside the reactor containment (CT) building and detect small leaks directly, was suggested and its feasibility was evaluated using MCNPX simulation. Materials and Methods: A target nuclide was selected through analysis of radiation from radionuclides in the reactor coolant system (RCS) and the spectrum was obtained via a silicon detector simulated in MCNPX. A window was designed to reduce the background signal caused by other nuclides. The sensitivity of the detector was also estimated, and its shielding designed for installation inside the reactor CT. Results and Discussion: The beta and gamma spectrum of the silicon detector showed a negligible gamma signal but it also contained an undesired peak at 0.22 MeV due to other nuclides, not the $^{16}N$ target nuclide. Window to remove the peak was derived as 0.4 mm for beryllium. The sensitivity of silicon beta detector with a beryllium window of 1.7 mm thickness was derived as $5.172{\times}10^{-6}{\mu}Ci{\cdot}cc^{-1}$. In addition, the specification of the shielding was evaluated through simulations, and the results showed that the integrity of the silicon detector can be maintained with lead shielding of 3 cm (<15 kg). This is a very small amount compared to the specifications of the lead shielding (600 kg) required for installation of $^{16}N$ gamma detector in inside reactor CT, it was determined that beta detector would have a distinct advantage in terms of miniaturization. Conclusion: The feasibility of the beta detector was evaluated for installation inside the reactor CT to detect small leaks below $0.5gpm{\cdot}hr^{-1}$. In future, the design will be optimized on specific data.

주사전자현미경용 전자검출기 (The Electron Detector in Scanning Electron Microscope)

  • 이상욱;전종업;한상훈
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.513-517
    • /
    • 2004
  • The nature of the signals collected by an SEM(Scanning Electron Microscope) in order to form images are all dependent on the detector used to collect them, and the quality of an acquired image is strongly influenced by detector performance. Therefore, the development of detector with high performance is very important in pulling up the resolution of SEM. In this article, electron beam-specimen interactions, the detection principle of secondary electrons and backscattered electrons, and the structure of a conventional detector are described. The structure of an experimental apparatus for the future study on our hopeful novel electron detector is presented as well.

  • PDF

SEM용 전자검출기의 제작 및 성능평가 (Manufacture and Performance Estimation of Electron Detector for SEM)

  • 김지원;전종업;부경석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1282-1287
    • /
    • 2007
  • The nature of the signal collected by an SEM(Scanning Electron Microscope) in order to form images are all dependent on the detector used to collect them, and the quality of an acquired images is strongly influenced by detector performance. Therefore, the development of detector with high performance is very important for improving on the resolution of SEM. This paper presents the manufacture of secondary electron detector and the optimal position of electron detector through numerical analysis in SEM.

  • PDF

경수로 제어봉구동장치제어계통의 영점위상탐지기 성능개선에 관한 연구 (Study for improvement of zero-cross detector of control element drive mechanism control system in PWR)

  • 김병문;이병주;한상준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.609-611
    • /
    • 1996
  • Zero-Cross Detector makes pilot signal to control the power to CEDM(Control Element Drive Mechanism). Existing Zero-Cross Detectors has had a problem which can cause unexpected reactor trip resulted from fluctuating frequency of input signal coming from M/G Set. The existing Zero-Cross Detector can't work properly when power frequency is varying because it was designed to work under stable M/G Set operation, and produces wrong pilot signal and output voltage. In this report the Zero-Cross Detector is improved to resolve voltage fluctuating problem by using new devices such as digital noise filtering circuit, variable cycle compensator and alarm circuit. And through the performance verification it shows that new circuit is better than old one. If suggested detector is applied to plant, it is possible to use it under House Load Operation because stable voltage can be generated by new Zero-Cross Detector.

  • PDF

직접수열 부호분할 다중접속 계통에서의 비모수 의사잡음 부호 획득 (Nonparametric PN code acquisition in DS/CDMA systems)

  • 송익호;이성로
    • 대한전자공학회논문지TC
    • /
    • 제37권6호
    • /
    • pp.372-372
    • /
    • 2000
  • 이 논문에서는 직접수열 부호분할 다중접속 계통에서 의사잡음 부호를 획득하는데 알맞은 비모수 방식을 제안한다. 이 방식에서는 매개변수를 쓰지 않기 때문에 시간에 따라 바뀌는 간섭의 분산을 추정하는 과정 없이 검파기의 문턱값을 결정할 수 있다. 이제까지의 검파기와 제안한 검파기의 성능을 수식 결과와 모의 실험 결과로 견주어보았다. 이 결과로부터 간섭의 분산을 정확히 추정할 수 없을 때에는, 제안한 검파기를 쓰는 직접수열 부호분할 다중접속 계통의 성능이 이제까지의 검파기를 쓸 때보다 좋음을 보였다.