• Title/Summary/Keyword: detective voltage

Search Result 7, Processing Time 0.023 seconds

An Implementation of Temperature Independent Bias Scheme in Voltage Detector (온도에 무관한 전압검출기의 바이어스 구현)

  • Moon, Jong-Kyu;Kim, Duk-Gyoo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.34-42
    • /
    • 2002
  • In this paper, we propose a temperature independent the detective voltage source in voltage detector. The value of a detective voltage source is designed to become m times of silicon bandgap voltage at zero absolute temperature. By properly choosing the temperature coefficient of diode, the temperature coefficient of a concave voltage nonlinearities generated by the ${\Delta}V_{BE}$ section of diode between base and emitter of transistors with a different area can be summed with convex nonlinearities the $V_{BE}$ voltage to achieve the near zero temperature coefficient of the detective voltage source. We designed that the value of a detective voltage can be varied by ${\Delta}V_{BE}$, the $V_{BE}$multiplier circuit and resistor. In order to verify the performance of a proposed detective voltage source, we manufactured the voltage detector IC for 1.9V which is fabricated in $6{\mu}m$ Bipolar technology and measured the operating characteristics, the temperature coefficient of a detective voltage. To reduce the deviation of a detective voltage in the IC process step, we introduced a trimming technology, ion implantation and an isotropic etching. In manufactured IC, the detective voltage source could achieve the stable temperature coefficient of 29ppm/$^{\circ}C$ over the temperature range of -30$^{\circ}C$ to 70$^{\circ}C$. The current consumption of a voltage detector constituted by the proposed detective voltage source is $10{\mu}A$ from 1.9V-supply voltage at room temperature.

A Study on the Algorithm for Fault Discrimination in Transmission Lines using Advanced Computational Intelligence(ACI) (ACI 기법을 이용한 송전선로 고장 종류 판별에 관한 연구)

  • Park Jae Hong;Lee Jong Beom
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.619-621
    • /
    • 2004
  • This paper presents the rapid and accurate algorithm for fault discrimination in transmission lines. When faults occur in transmission lines, fault discrimination is very important. If high impedance faults occur in transmission lines, it cannot be detected by overcurrent relays. The method using current and voltage cannot discriminate high impedance fault. Because of this reason this paper uses voltage and zero sequence current, and the proposed algorithm uses fuzzy logic method. This algorithm uses voltage and zero sequence current per period in case of faults. Single line ground fault and three-phase fault can be detective using voltage. Two-line ground fault and line to line fault and high impedance can be detected using zero sequence current. To prove the performance of the algorithm, it test algorithm with signal obtained from ATPDraw simulation.

  • PDF

The Study on X-ray Detection Characteristics of Radiation Detective Sensor with Changing Composition Ratio of Iodine in a-Se (a-Se에 첨가된 Iodine의 조성비 변화에 따른 X선 검출특성 연구)

  • Cha, Byung-Youl;Kang, Sang-Sik;Lee, Gyu-Hong;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.399-402
    • /
    • 2002
  • This paper is researched that electric characteristic of Digital x-ray radiography technique with changing composition ratio of Iodine. Dopant material, Iodine is evaporated with amorphous selenium. Thorugh the old papers say, doponted Iodine will be down the created trap level because of Arsenic dopant material in amorphous selenium. Arsenic material of Composition ratio in amorphous selenium is fixed with 0.3% and test sample is deposited composition of 30, 100, 300, 500, 700ppm with thermal evaporate system. Experimental measurement is performed by dark current and x-ray sensitivity in amorphous selenium based radition detector sensor. Fabricated test sample thickness is $30{\mu}m$ and injected voltage is $3{\mu}m$$6{\mu}m$$9{\mu}m$ to both electrode. Experimental results showed that the net charge of composition rate of 30ppm is 398.88 pc/mR/$cm^2$ very high. And increase of the Iodine composition ratio is tendency to the decrease of net charge. Doping changing composition of Iodine in amorphous selenium detector offered to basical information of amorphous selenium material.

  • PDF

Survey of Technical Parameters for Pediatric Chest X-ray Imaging by Using Effective DQE and Dose (유효검출양자효율과 선량을 이용한 소아 흉부 X-선 영상의 기술적인 인자에 관한 조사)

  • Park, Hye-Suk;Kim, Ye-Seul;Kim, Sang-Tae;Park, Ok-Seob;Jeon, Chang-Woo;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.163-171
    • /
    • 2011
  • The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kVp in 10 kVp increments at the FDD of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at the same effective dose. The results showed that the eDQE was largest at 60 kVp when compares the eDQE at different tube voltage. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing FDD because of the greater effective modulation transfer function (eMTF). However, most of major hospitals in Korea employed a short FDD of 100 cm with an anti-scatter grid for the chest radiological examination of a 15 month old infant. As a result, the entrance surface air kerma (ESAK) values for the hospitals of this survey exceeded the Korean DRL (diagnostic reference level) of $100{\mu}Gy$. Therefore, appropriate technical parameters should be established to perform pediatric chest examinations on children of different ages. The results of this study may serve as a baseline to establish detailed reference level of pediatric dose for different ages.

DEVELOPMENT OF THE SOLAR EUV TELESCOPE ENGINEERING MODEL FOR A SATELLITE (인공위성 탑재용 극자외선 태양망원경(EUVT) EM 개발)

  • 이선민;장민환;이은석
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.4
    • /
    • pp.327-338
    • /
    • 2003
  • The aim of this paper is to describe the results of the study on the extreme-ultra-violet (EUV) solar telescope, which is designed to. a possible satellite mission. Since the EUV band can not be observed on the ground, the observation in EUV should be performed in space using a satellite or a rocket. Design of the Extreme-Ultra-Violet solar Telescope (BUVT) in this study is based on "Designing a small-sized engineering model of solar EUV telescope for a Korean satellite" (Han et al. 2001). Our EUVT design is satisfied with the requirements for a satellite in size and input voltage. The major goal of the study is to confirm if we can detect the specific wavelength (58.4nm to 62.9nm) with the EUVT. We describe re-designing of the EUVT to decrease a shelter ratio. Also we describe the technics in the optic system and the detector, which were used to manufacture the EUVT. We explain the detective program, which is to calculate the amount of the solar radiation, and the image data processing system.ng system.

A study on a moving characteristics of charged particle in uniform electric field of Charged Particle type Display (대전입자형 디스플레이의 균등전계내 대전입자의 거동특성에 관한 연구)

  • Lee, Dong-Jin;Kim, Young-Cho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.6
    • /
    • pp.1186-1190
    • /
    • 2009
  • In this paper, we studied on a characteristic of movement of charged particle in equal electric field. In order to fabricate a panel, we used positive charged toner particles of black and negative one of yellow. Panel was biased rectangle pulse without any overshoot. Also, panel's optical characteristics with contrast ratio and viewing angle is measured with RT-200. Response time was measure by using incident laser and detective photodiode. The distribution of m/q of particles by driving in panel throughout the contrast ratio and response time. As a results, driving voltage, contrast ratio, and response time are decided by m/q of charged particles and when m/q of charged particles in panel have regular distribution, it is induce improvement driving characteristics.

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.