• Title/Summary/Keyword: detective system

Search Result 70, Processing Time 0.025 seconds

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

A Study on the Tool Life Detection System in Cutting Process. (절삭가공중의 공구수명검출 시스템 개발에 관한 연구)

  • 김정두;최종순
    • Journal of the Korean Professional Engineers Association
    • /
    • v.21 no.4
    • /
    • pp.6-11
    • /
    • 1988
  • The study on the progress of automatic machining system has been active centering at the CNC machine tools recently to lead the applied production technology like unmaned machining to the practical level, and to make these application more efficient, they require detective method for tool wear and breakage while machining. In this study chiefly on turning, first derive cutting force about the tool surface by the cutting resistant sensor and with which change into electric signal and compare with the standards to make the tool life detection system to let know the tool life and study its application; the cutting resistance detected by the cutting resistant sensor has increased to the level of standards, the measuring system which can decide whether we change tools on the basis of comperative circuit is shown to be very reliable model for cutting tool life detection system.

  • PDF

The Dehistoricization Trend in Historical Plays: Play with History and Everyday Life History Writing (역사극의 탈역사화 경향: 역사의 유희와 일상사적 역사 쓰기)

  • Kim, Sunghee
    • Journal of Korean Theatre Studies Association
    • /
    • no.48
    • /
    • pp.51-84
    • /
    • 2012
  • In Korea, historical plays took an epoch-making turn from the previous historical plays in terms of approaches to topic and material and methods of rewriting history in the 1990s. Historical plays became dehistoricized with individual, everyday life, and faction emerging as major codes of historical plays according to mistrust in history and grand narrative as the original and disappearance of trust in the growth and totality of history. A new trend became dominant of presenting fictionality prominent instead of reproduction of history and freely playing with history outside the context. While modern historical plays were subject to the content of history, post-modern historical plays sought after new history writing to tell a new story on history within a framework of fiction. Focusing on some of the trends in post-modern historical plays since the 1990s, which include play with history, daily life-style history writing, and reproduction patterns of colonial modernity, this study examined the goals, representations, and text strategies of new history writing in three historical plays, Generation After Generation(2000) by Park Geunhyung, The Mercenaries(2000) by Park Sujin, and Chosun Detective Hong Yunshik(2007) by Sung Giwoong. In Generation After Generation, the author adopts a plot of starting with the present and tracing back to the past, breaking down the myth of racially homogeneous nation. At the same time, he discloses that the colonial history is not just by the oppressive force of Japan but also by the voluntary cooperation of Korean people. That is, we are also accountable for the colonial history of the nation. The Mercenaries contrasts the independence movement during the colonial period against the modern history developed after Liberation, thus highlighting the still continuing coloniality, namely post-colonial present. The past is presented as the "phantom of history" making its appearance according to the request of the present hoping for salvation. The author politicizes history and grants political wishes to history by summoning the history by personal memories such as fictional diaries and letters with Messiah-like images opposed to the present of collapse and catastrophe. In Chosun Detective Hong Yunshik, the author makes an attempt at the microscopic reproduction of daily life by approaching the 1930s as the modern period when capitalist daily life started to take root. The lists of signs comprising daily life in colonial Gyeongseong are divided between civilization and savagery and between modern and premodern. With the progress of narrative, however, they become mixed together and reversed in the representation system in which the latter overwhelms the former.

Quantitative Analysis and Comparison of DR and CR image quality (CR과 DR 영상화질의 정량적 비교분석)

  • Park, Hey-Suk;Seo, Jang-Yeon;Jeong, Jin-Hwa;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.31-37
    • /
    • 2007
  • The purpose of this research was to compare and analyze image quality for each Detector of CR(Computed Radiography) and DR(Digital Radiography). The results showed that CR(AGFA MD 4.0 General plate, JAPAN) was superior to DR(HOLOGIC nDirect Ray, USA) based on the quantitative values and comparison of MTF(Modulation Transfer Function), NPS(Noise Power Spectrum), Photon fluence and DQE(Detective Quantum Efficiency) which have been widely accepted for the estimation of CR and DR. Quantitative evaluations of CR and DR system were obtained and they may be very helpful for QA and QC of general X-ray systems.

  • PDF

The Study on X-ray Detection Characteristics of Radiation Detective Sensor with Changing Composition Ratio of Iodine in a-Se (a-Se에 첨가된 Iodine의 조성비 변화에 따른 X선 검출특성 연구)

  • Cha, Byung-Youl;Kang, Sang-Sik;Lee, Gyu-Hong;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.399-402
    • /
    • 2002
  • This paper is researched that electric characteristic of Digital x-ray radiography technique with changing composition ratio of Iodine. Dopant material, Iodine is evaporated with amorphous selenium. Thorugh the old papers say, doponted Iodine will be down the created trap level because of Arsenic dopant material in amorphous selenium. Arsenic material of Composition ratio in amorphous selenium is fixed with 0.3% and test sample is deposited composition of 30, 100, 300, 500, 700ppm with thermal evaporate system. Experimental measurement is performed by dark current and x-ray sensitivity in amorphous selenium based radition detector sensor. Fabricated test sample thickness is $30{\mu}m$ and injected voltage is $3{\mu}m$$6{\mu}m$$9{\mu}m$ to both electrode. Experimental results showed that the net charge of composition rate of 30ppm is 398.88 pc/mR/$cm^2$ very high. And increase of the Iodine composition ratio is tendency to the decrease of net charge. Doping changing composition of Iodine in amorphous selenium detector offered to basical information of amorphous selenium material.

  • PDF

A Study on Improving Private Investigation Work Efficiency to Missing Cases (탐정의 실종사건 조사업무 효율성 제고방안에 관한 연구)

  • Kim Sang Min;Sun Jun Ho;Yeom Keon Ryeong
    • Industry Promotion Research
    • /
    • v.8 no.4
    • /
    • pp.241-250
    • /
    • 2023
  • In investigating missing persons cases, the focus is on strengthening the efficiency of detectives' work in investigating missing persons cases. Disappearance cases are seen as a problem that directly affects social safety and individual well-being. The research has the following structure. The introduction presents the necessity, scope, and methodology of the study. Next, we analyze the definition, causes, types and actual conditions of disappearance cases. In terms of problems in the process of handling missing persons cases, the initial response process, problems in the response of related agencies after reporting, problems due to the prolongation of the case, and problems due to legal restrictions are analyzed. In the plan to improve the work efficiency of detectives for disappearance cases, the revitalization of public interest investigation networks, strengthening of capacity related to disappearance case investigation, professional public interest detective certification system, and establishment of exception provisions for detective activities are discussed. In the conclusion, we present what is necessary for the activities of public interest detectives specializing in missing persons cases.

The introduction of a criminal case arbitration on premise the civil and commercial arbitration (민상사(民商事) 중재제도(仲裁制度)를 전제(前提)로 한 형사중재제도(刑事仲裁制度)의 도입방안(導入方案))

  • Nam, Seon-Mo
    • Journal of Arbitration Studies
    • /
    • v.19 no.3
    • /
    • pp.93-119
    • /
    • 2009
  • Nowadays the number of crimes is increasing rapidly and society is getting more and more dangerous. Recently the criminal aspect of our society, the intelligence, diversity, localized area, as well as for the crime victims also difficult to predict the damage recovery is not easy to change their level of pain and are also serious. This phenomenon is increasingly expected to intensify, the proper response is a factory. The more so if the victim of murder. The criminal mediation working on the operational adjustments Borrower payment, Construction charges, investments and financial transactions due to interpersonal conflicts that occurred as a fraud, embezzlement, breach of trust property crimes such accused, individuals between the defamatory, offensive, encroachment, violating intellectual property rights and private Disputes about the complaint case and other criminal disputes submitted to mediation to resolve it deems relevant to the case who are accused. But the core of a detective control adjustment, adjust the members' representative to the region, including front-line player or a lawyer appointed by the attorney general at this time by becoming parties to this negative view may be ahead. Some scholars are criticizing the current criminal justice system for the absence of proper care for the criminal victims, as an alternative to the traditional criminal justice system. The introduction of the summary trial and related legal cases, the command structure, compensation system, crime victims' structural system can be seen as more classify, crime subject to victim's complaint, By case with a criminal misdemeanor in addition to disagree not punish criminal, minor offense destination, traffic offenders, regular property crime, credit card theft, intellectual property rights violators can be seen due to more categories can try. They sued in law enforcement, Prosecution case has been received and if any one party to the criminal detective Arbitration request arbitration by the parties can agree to immediately contact must be referred to arbitration within 15 days of when the arbitration case will be dismissed. These kinds of early results of the case related to, lawyers are involved directly in the arbitration shall be excluded. Arbitration system is the introduction of criminal justice agencies working to help resolve conflicts caused by adjustment problems will be able to. This article does not argue that we should stick to the traditional justice system as a whole. Instead it argues that the restrictive role of the traditional justice is to be preserved.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Basic Study of the Improvement of PSD Output by Inclined Light Input (PSD의 출력특성향상을 위한 경사 입력광의 특성해석에 대한 기본연구)

  • Kweon, Hyun-Kyu;Park, Chang-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.4
    • /
    • pp.53-58
    • /
    • 2010
  • In this paper, the output characteristics of PSD(Position Sensetive Detector) used in measurement system are described. Most of the precision measurment systems are accomplished by a laser diode(LD), a photo diode(PD) and PSD(Position Sensetive Detector), which are used in reflection of mirror or projection of infrared spectrometer. But it is especially restricted by resolution of PD and PSD in nano-measurement. A new inclined light methods into the PSD are employed in the surface measurement system for increasing the resolution. As the results, we can know that the output characteristics of detective senser (PSD) become more than 2 or 3 times by changing inclined angle(range: 5 degree) compared with common angle. In addition, the experiment results are confirmed that the change of inclined angle is not affecting to the linearity and repeating.

Construction and Performance Evaluation of Digital Radiographic System (이동형 디지털 X선 촬영장치의 구축 및 성능평가)

  • Cho, Hyo-Min;Nam, So-Ra;Lee, Chang-Lae;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.144-148
    • /
    • 2007
  • Current digital radiography systems are rapidly glowing in clinical applications. The purpose of this study was to evaluate the characteristics of a mobile digital radiographic system. The performance of the mobile DR system was evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on a LISTEM Mobix-1000 generator and a Teleoptic PRA Alpha-R4000 detector. Imaging characteristics were measured for these two systems using the IEC-61267 defined RQA5 (kVp: 74, additional filtration: 21 mmAl) radiographic condition. The MTF at 10% was measured as 2.4 cycles/mm and the DQE(0) values for radiation exposure 0.19, 0.5, and 1.3 mR were measured as 54%, 55%, and 76%, respectively. The NPS curves gradually decreased at high spatial frequencies. This high DQE at low frequencies, may be useful for low frequency information. The results suggested that mobile DR system could be integrated with emergency ambulance system in teleradiologic imaging applications.

  • PDF