• Title/Summary/Keyword: detective system

Search Result 70, Processing Time 0.027 seconds

A Study on the Objective Opinion of Private Investigation Service (민간조사제도 도입 반대 의견에 대한 고찰)

  • Jeng, Il-Seok;Park, Jun-Seok;Suh, Sang-Yul
    • Korean Security Journal
    • /
    • no.14
    • /
    • pp.465-484
    • /
    • 2007
  • Our society's modernization created many opportunities for us to need a private investigation service system. Variation of international environment due to joining in the OECD, opportunity of individual legal, collect evidence during judgement, prevention of damage criminal, security of business in company, free trade economy's system etc and don't need to enumerate how important of introduction of private investigation service system. In addition to there are lots of objection opinions, such as possibility of person's private life, invade of lawyer's area, confliction with investigation team, gap of wealth and poverty that make preponderance of information. So this research can be considerate from objective opinion, and can obtain conclusion just like below. First, private detective agencies that encroach on the individual rights will naturally deteriorate after the implementation of private investigation service system. Through this, the probability of civil rights encroachment will be lower, and for this to happen there needs to be a thorough maintenance of the system. Secondly, mutually beneficial solution should be found not by a conflict between two sides. Detective business sector should not cause social confusion from conflicts with other investigation organization such as police, or investigators, rather, it must get on the demand of the diversified citizen and maintain the diverse sector inter-cooperate right, and to do that law and institution must be made for the base. Thirdly, investigation used depending on the gap between wealth and poverty does not mean the actualization of the rights and interests of the citizen. If the duty of investigation sector is to find the evidence and collect or manufacture of the evidence, then the problems which the nation can't handle will be more enlarged and then finally end up with strengthening the capability of national public security demand.

  • PDF

Investigation of Physical Imaging Properties in Various Digital Radiography Systems (다양한 디지털 방사선 시스템의 물리적 영상 특성 조사)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Yoon, Yong-Su;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.363-370
    • /
    • 2017
  • We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

Characterization of Imaging and Physical Properties in Digital Radiography System (디지탈 X-선 촬영시스템의 영상 및 물리적 특성 분석)

  • Kim, Jong-Hyo;Lee, Tae-Soo;Park, Kwang-Suk;Han, Man-Cheong;Lee, Choong-Woong;Min, Byoung-Goo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.7
    • /
    • pp.112-124
    • /
    • 1989
  • In order to evaluate imaging performance of newly developed digital radiography system which requires scanning time as short as 0.7 sec and patient exposure as low as 3 mR, we have investigated its imaging and physical properties such as sensitivity characteristic, scatter fraction, detective quantum efficiency, modulation transfer function, and contrast detail diagram. The results show that the digital radiography system has linear sensitivity to the incident energy, and superior contrast resolving power with less X-ray exposure than conventional film-screen system. These performances are resulted from excellent scatter rejection capability and high detective quantum efficiency of digital radiography system.

  • PDF

Imaging Characteristics of Plastic Scintillating Fiber Screens for Digital Mammography

  • Choi, Won-Young;Walker, James K.;Jing, Zhenxue
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.165-172
    • /
    • 1996
  • A scanning slot digital mammography system Luing a plastic scintillating fiber screen (SFS) is currently being developed To improve the x-ray interaction efficiency and absorption efficiency of an SFS, high Z elements can be added into the scintillating fiber core. In this paper, we investigated theoretically the zero spatial frequency detective quantum efficiency, DQE(0), and modulation transfer function, MTF(f), of three 2 cm thick SFSs made of polystyrene, polystyrene loaded with 5% by weight of lead, and polystyrene Loaded with 10% by weight of tin scintillating fibers. X-ray interaction efficiency, scintillating light intensity distributions and line spread functions were generated using Monte Carlo simulation. DQE(0) and MTF(f) were computed for x-ray energies ranging from 15 to 50 keV. Loading high Z elements into the SFS markedly increased the DQE(0). For x-ray energies used for mammovaphy, DQE(0) values of both high Z element loaded SFSs are about a factor of three higher than the DQE(0) of an Min-R screen. At mammographic x-ray energies, MTF(f) values of all three SFSs are Venter than 50% at 25 Ip/mm spatial frequency, and were found to be dominated by the 20 um individual scintillating fiber diameter used The results show that both hiP DQE(0) and spatial resolution can be achieved with the high Z element loaded SFSs, which make these SFSs attractive for use in a scanning slot detector for digital mammography.

  • PDF

Fault Diagnosis for the Nuclear PWR Steam Generator Using Neural Network (신경회로망을 이용한 원전 PWR 증기발생기의 고장진단)

  • Lee, In-Soo;Yoo, Chul-Jong;Kim, Kyung-Youn
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.6
    • /
    • pp.673-681
    • /
    • 2005
  • As it is the most important to make sure security and reliability for nuclear Power Plant, it's considered the most crucial issues to develop a fault detective and diagnostic system in spite of multiple hardware redundancy in itself. To develop an algorithm for a fault diagnosis in the nuclear PWR steam generator, this paper proposes a method based on ART2(adaptive resonance theory 2) neural network that senses and classifies troubles occurred in the system. The fault diagnosis system consists of fault detective part to sense occurred troubles, parameter estimation part to identify changed system parameters and fault classification part to understand types of troubles occurred. The fault classification part Is composed of a fault classifier that uses ART2 neural network. The Performance of the proposed fault diagnosis a18orithm was corroborated by applying in the steam generator.

A Study on the Private Investigator System in U.S.A. (미국의 탐정제도에 관한 연구)

  • Kang, Young-Sook;Kim, Tae-Hwan
    • Korean Security Journal
    • /
    • no.12
    • /
    • pp.25-50
    • /
    • 2006
  • Private detectives and investigators offer many services, including executive, corporate, and celebrity protection; pre-employment verification; and individual background profiles. They also investigate computer crimes, personal injury cases, insurance claims and fraud, child custody and protection cases, missing persons cases, and premarital screening. This paper focuses on a private detective or investigator system in most developed U.S.A, but it is not easy to describe that system. Licensing requirements vary in U.S.A. Some States have few requirements, and many other States have stringent regulations. A growing number of States are enacting mandatory training programs for private detectives and investigators. Employment and need of private detectives and investigators is expected to grow faster than the average for all occupations. Thus, it is reasonable that korean government should permit private investigation service find the way to minimize the side effects of private investigation service instead of banning the service totally.

  • PDF

Early Detective Warning System of Fire in the Tunnel Road (도로터널 내 차량사고 화재조기감지 예고 시스템)

  • Yoon, Sungwook;Kim, Hyenki
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2012.05a
    • /
    • pp.291-292
    • /
    • 2012
  • 본 연구는 여러 가지 센서를 이용하여 자동차 전용 도로터널의 차량 사고시의 음향을 인식하여 사고인식률을 높이는 화재 예고 시스템에 관한 연구이다. 현행의 CCTV나 자동화재탐재설비에서 감지하는 열센서나 영상전송자료를 파악하기에 앞서, 이차적 재해 가능성을 유의미한 수준에서 미리 예고하고 대응할 수 있는 사전예고시스템을 구성하였다. 유선설치기반의 센서로 대부분 구성된 도로터널 내에서 비교적 설비가 저렴한 무선센서를 사용함으로서 기존 터널에서의 적용성을 증대시켰다.

  • PDF

Evaluation of the Performance Characteristic for Mammography by Using Edge device (유방영상에서 엣지를 이용한 물리적 영상 평가)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Lee, Eul-Kyu;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.415-420
    • /
    • 2016
  • The purpose of this study was to evaluation of the performance characteristic for mammography by using edge device that mammography equipment improves essential in the correct diagnosis for the maintenance. We measured the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using the 61267 RQA-M2 based on commission standard international electro-technical commission (IEC). As a results, spatial resolution of elenia demensions tomo and lorad selenia mammography were maintained at $10mm^{-1}$ and NPS and DQE including the low nyquist frequency indicated to $6.0mm^{-1}$. Therefore, regulary QA of mammography system should be necessary. This study can be contribute to evaluate QA for performance characteristic of mammography of DDR system.

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

Research trend analysis of the introduction at the issue of private investigation institution (민간조사제도 도입시 쟁점에 대한 연구동향 분석)

  • Seo, Jin-Seok
    • Convergence Security Journal
    • /
    • v.15 no.3_2
    • /
    • pp.11-19
    • /
    • 2015
  • This paper, so far to analyze the research trends in the issue that has been discussed for the introduction of private investigation institutions, by projecting its suggestion, want the investigation purpose of presenting the desirable introduction direction. The analyzed issue was extracted for existing research material on the introduction of private investigation institutions. Investigators pointed out issue is the name, business scope, corporate, qualification system (eligibility criteria and test), education, association establishment, regulatory agencies, has been included in the eight categories such as legislation form. For the name, I think there is a need to unify under the name "detective". For the scope of work, the amendment is difficult law, place an overview of the general business rules, more specific and detailed investigation business content, to discipline through the ordinance it is possible to be rational. Private investigation institutions, I think the need for limited operations of the corporation. For education, the new education and re-education on a regular basis I do for the private investigation workers. You must be one of the National Police Agency to the management authority. Legislative form, not to be defined by its own law, the revision of the security law, but that is to complement the provisions for private sector research system is effective.