• 제목/요약/키워드: detection limit

검색결과 2,421건 처리시간 0.026초

Selective Trace Analysis of Mercury (II) Ions in Aqueous Media Using SERS-Based Aptamer Sensor

  • Lee, Chank-Il;Choo, Jae-Bum
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권6호
    • /
    • pp.2003-2007
    • /
    • 2011
  • We report a highly sensitive surface-enhanced Raman scattering (SERS) platform for the selective trace analysis of mercury (II) ions in drinkable water using aptamer-conjugated silver nanoparticles. Here, an aptamer designed to specifically bind to $Hg^{2+}$ ions in aqueous solution was labelled with a TAMRA moiety at the 5' end and used as a Raman reporter. Polyamine spermine tetrahydrochloride (spermine) was used to promote surface adsorption of the aptamer probes onto the silver nanoparticles. When $Hg^{2+}$ ions are added to the system, binding of $Hg^{2+}$ with T-T pairs results in a conformational rearrangement of the aptamer to form a hairpin structure. As a result of the reduced of electrostatic repulsion between silver nanoparticles, aggregation of silver nanoparticles occurs, and the SERS signal is significantly increased upon the addition of $Hg^{2+}$ ions. Under optimized assay conditions, the concentration limit of detection was estimated to be 5 nM, and this satisfies a limit of detection below the EPA defined limit of 10 nM in drinkable water.

Determining Potassium Bromate in the Inhalable Aerosol Fraction in Workplace Air with Ion Chromatography

  • Kowalska, Joanna;Lis, Monika;Biesaga, Magdalena
    • Safety and Health at Work
    • /
    • 제12권2호
    • /
    • pp.209-216
    • /
    • 2021
  • Background: The article presents the results of studies performed in order to develop a new method of airborne potassium bromate(V) determination at workplaces. Methods: The method is based on a collection of the inhalable fraction of potassium bromate(V) using the IOM Sampler, then extraction of bromates with deionized water and chromatographic analysis of the obtained solution. The analysis was performed using ion chromatography with conductometric detection. The tests were performed on a Dionex IonPac®AS22 analytic column (250 × 4 mm, 6 ㎛) with AG22 precolumn (50 × 4 mm 11 ㎛). Results: The method provides for potassium bromate(V) determination within the concentration range of 0.043 ÷ 0.88 mg/m3 for an air sample of 0.72 m3 in volume, i.e., 0.1-2 times the exposure limit value as proposed in Poland. The method was validated in accordance with PN-EN 482. The obtained validation data are as follows: measuring range: 3.1-63.4 ㎍/mL, limit of detection (LOD) = 0.018 ㎍/mL and limit of quantification (LOQ) = 0.053 ㎍/mL. The developed method has been tested in the work environment, on laboratory employees having contact with potassium bromate(V). Conclusion: The analytical method allowed the determination of the inhalable fraction of airborne potassium bromate(V) at workplaces and can be used to assess occupational exposure.

잠수함의 종동요각 한계예측 알고리즘 설계 (Design of Pitch Limit Detection Algorithm for Submarine)

  • 박종용;김낙완;신용구
    • 한국해양공학회지
    • /
    • 제30권2호
    • /
    • pp.134-140
    • /
    • 2016
  • An envelope protection system is a control system that allows a submarine to operate freely using its own operational envelope without exceeding the structural limit, dynamic limit, and control input limit. In this paper, an envelope protection system for the pitch angle of a submarine is designed using a dynamic trim algorithm. A linear quadratic regulator and artificial neural network are used for the true dynamics approximation. A submarine maneuvering simulation program developed using experimental data is used to validate the designed envelope protection system. Simulation results show the effectiveness of the designed envelope protection system.

A Simple Proposition for Improving Industrial Hygiene Air Sampling Methods

  • Paik, Samuel Y.;Zalk, David M.
    • Safety and Health at Work
    • /
    • 제10권3호
    • /
    • pp.389-392
    • /
    • 2019
  • When conducting an exposure assessment, the primary goal of the industrial hygienist is to fully characterize the worker's exposure during a work shift to compare it with an occupational exposure limit. This applies regardless of the duration of the work activity as an activity that is relatively short in duration can still present exposure in excess of the occupational exposure limit even when normalized over an 8-hr shift. This goal, however, is often impeded by the specification of a minimum sample volume in the published sampling method, which may prevent the sample from being collected or submitted for analysis. Removing the specification of minimum sample volume (or adjusting it from a requirement to a recommendation), in contrast, allows for a broader assessment of jobs that consist of short-duration and high-exposure activities and also eliminates the unnecessary practice of running sampling pumps in clean air to collect a specified, minimum volume.

식육중의 잔류 항생.항균제의 검정에 관한 연구(I) -생물학적 검정법- (A Study on the Determination of Residual Antibiotics and synthetic antibacterial agents in Meat(I) -Microbiological Assay-)

  • 류재천;송윤선;박종세;장준식;신보승언
    • 한국식품위생안전성학회지
    • /
    • 제8권1호
    • /
    • pp.1-8
    • /
    • 1993
  • 육류중에 잔류하는 항생물질 및 항균제를 검출하기 위해 본 실험에서는 3종의 균주 Bacillus subtilis ATCC 6633, Micrococcus luteus ATCC 9341, BAcillus cereus var. mycoides ATCC 11778을 사용하여 실험하였다. 시료의 clean-up은 항생·항균제의 물리화학적 성질을 고려하여 우선 McIlvaine buffer를 가하여 homogenize하고 hexane으로 defatting 시킨 후, chloroform으로 추출한 액과 Sep-Pak C18과 Bakerbond SPE carboxylic acid column에 흡착시킨 후 추출한 액을 각각 시험용액 A, B, C,로 하였다. 각 test solution을 paper disk를 사용하여 함균 배지에 올려놓고 overnight culture 후 inhibition pattern을 통해 여러 종류의 항생·항균제를 계통적으로 검출하였다. 본 실험에서 macrolide계와 tetracycline계 등은 0.1ppm 이하의 detection limit을 보였으며, penicillinrP는 0.001ppm이하의 높은 detection limit을 나타내므로서 시료중에 잔류하는 극미량까지도 검출할 수 있었다. 본 방법은 식육중의 잔류 항생·항균제를 동시에 간단하게 계통적으로 분류하는데 있어 좋은 방법이라고 생각되며 항생·항균제의 체계적인 1차 screening 수단으로서 유용한 방법이라 사료된다.

  • PDF

제주도 연안 해양환경 중 유기린계 농약의 잔류 (Residue of Organophosphorus Pesticides in the Coastal Environment on the Cheju Island)

  • 김정호;오윤근;박병윤
    • 한국환경과학회지
    • /
    • 제8권4호
    • /
    • pp.503-507
    • /
    • 1999
  • To study the residue of organophosphorus pesticides in the ocean environment on the Cheju island, EPN[O-ethyl-O-4-nitrophenyl phenylphosphonothioate] and monocrotophos [Dimethyl-1-methyl-2-methyl carba-moylvinylphosphate] of organophosphorus pesticides are surveyed on coastal environment of Cheju city and Wimi in May and October 1996. The qualified limit detection of EPN and monocrotophos are 0.005ng/mL and 0.006ng/mL in the water by GC-FPD, respectively. The qualified limit detection of EPN and monocrotophos are 0.010ng/g and 0.012ng/g in the solid such as sediment and sea organism by GC-FPD, respectively. EPN and monocrotophos are not detected in seawater and sedimnet. Moreover EPN and monocrotophos are neither detected in seaweed cava (Ecklonia cava), Agar (Gelidium amansii), turban sell(Batillus cornutus) and sea urchin(Anthocidaris Crassispina). EPN, monocrotophos used in the farm on the Cheju island are not residued in the coastal environment in the Cheju island.

  • PDF

흡착관/열탈착 GC/MS 방법에 의한 모사시료 중의 미량 페놀 분석에 관한 평가 (Evaluation of the Measurement of Trace Phenols by Adsorption/Thermal Desorption/Gas Chromatography/Mass Spectrometry (ATD/GC/MS) in Artificial Air)

  • 허귀석;이재환;황승만;정필갑;유연미;김정우;이대우
    • 한국대기환경학회지
    • /
    • 제18권2호
    • /
    • pp.127-137
    • /
    • 2002
  • Phenolic compounds in air are toxic even at their low concentrations. We had evaluated a total of five phenolic compounds (Phenol, o-Cresol, m-Cresol, 2-Nitrophenol and 4-Chloro-3-methylphenol) in artificial air using a combination of ATD/GC/MS. To compare the adsorption efficiency of these phenolic compounds, three adsorbents (Tenax TA, Carbotrap and Carbopack B) were tested. Tenax TA adsorbent was most effective of all the adsorbents used for the efficiency test. Five phenolic compounds were found to be very stable on adsorbent tubes for 4 days at room temperature. Detection limit of five phenolic compounds ranged from 0.05 to 0.08 ppb (when assumed to collect 10 L air). The calibration curve was linear over the range of 22∼ 164 ng. The reproducibility was less than 4%. Sampling of duplicate pairs (DPs) was made to demonstrate duplicate precision and sampling efficiency.

ICP/AES에 의한 먹는물의 무기원소 분석 (Elemental Analysis of Drinking Water with ICP/AES)

  • 박계헌;신형선;한정희
    • 자원환경지질
    • /
    • 제29권1호
    • /
    • pp.21-24
    • /
    • 1996
  • Inductively coupled plasma atomic emission spectrophotometer (ICP/AES) is a versatile modern instruments for the multi-element analysis, but quantitative analysis using ICP/AES with normal pneumatic nebulizer is not applicable for the measurement of elemental concentrations in water down to the drinkining water standard level except a few elements because of poor detection limits. However, the detection limit can be lowered enough to measure drinking water standard, if ultrasonic nebulizer and/or hydride vapor generator is attached. This method is tested with groundwater samples from Tajeon area. It is confirmed that the elemental concentrations in these samples are within the limit of drinking water standard for the most elements. However, uranium concentration is very high in some samples compared with the concentrations suggested by Environmental Protection Agency of U.S.A. There is no standard concentration level to this element in Korea and it should be prepared immediately.

  • PDF

토양 중의 비휘발성 산성 유기 Priority Pollutants 동시분석에 관한 연구 (Simultaneous Analysis of Semi-Volatile Organic Acid Priority Pollutants in Soil)

  • 이승석;박교범;이성근
    • 대한화학회지
    • /
    • 제38권3호
    • /
    • pp.246-253
    • /
    • 1994
  • 미국 환경청이 지정한 129종의 priority pollutants 중 11종의 비휘발성 산성 유기화합물을 대상물질로 선정하여 토양시료 중의 극미량 분석방법을 연구하였다. 분석방법으로 기체크로토그래프/질량분석기- SIM(selected ion monitoring)법을 검출방법으로 정하고, 토양시료의 추출 및 농축방법으로 사용한 초음파 추출법(sonication extraction)과 Soxhlet(Soxhlet extraction)을 비교 연구하였다. 각 화합물의 회수율, 상대표준편차 및 method detection limit를 측정하여 EPA분석법을 대체할 수 있는지의 가능성을 조사하였다.

  • PDF

Electrochemical Behavior of Norfloxacin and Its Determination at Poly(methyl red) Film Coated Glassy Carbon Electrode

  • Huang, Ke-Jing;Xu, Chun-Xuan;Xie, Wan-Zhen
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권5호
    • /
    • pp.988-992
    • /
    • 2008
  • A poly(methyl red) film-modified glassy carbon electrode (PMRE) was fabricated for determination of norfloxacin (NFX). The electrochemical behavior of NFX was investigated and a well-defined oxidation peak with high sensitivity was observed at the film electrode. PMRE greatly enhanced the oxidation peak current of NFX owing to the extraordinary properties of poly(methyl red) film. Based on this, a sensitive and simple voltammetric method was developed for measurement of NFX. A sensitive linear voltammetric response for NFX was obtained in the concentration range of $1\;{\times}\;10^{-6}\;-\;1\;{\times}\;10^{-4}$ mol/L and the detection limit was $1\;{\times}\;10^{-7}$ mol/L using linear sweep voltammetry (LSV). The proposed method possessed advantages such as low detection limit, fast response, low cost and simplicity. The practical application of this new analytical method was demonstrated with NFX pharmaceuticals.