• Title/Summary/Keyword: design low-flow

Search Result 1,016, Processing Time 0.032 seconds

The Feasibility Analysis of Urban Public Rental Housing in Korea (도심형 공공임대주택의 사업타당성 분석)

  • Kim, Ok-Yeon;Kim, Yong-Tai;Kim, Yong-Soon
    • Land and Housing Review
    • /
    • v.6 no.3
    • /
    • pp.117-127
    • /
    • 2015
  • Korean government has launched a new public rental housing policy for younger generation suffering from instable housing conditions in CBD area. This paper is to analyze the financial feasibility of urban public rental housing projects, based on its cash flows. Urban rental housing projects should find out the way to reduce costs and to secure cheap land, because of the high land price in CBD area and complex relationship of legal rights. Project types are categorized by the land acquisition method and district characteristics. For 10 sample projects, financial feasibility was analyzed. Cash flows were calculated on the design plan and 16 scenarios were made by combining 4 important variables. The variables are increase rate of land price, increase rate of monthly rents, ratio of public and market rents, and the interest rate of National Housing Fund. The findings are as follows. Government land rent-type can reduce initial costs because it is not necessary to buy land. However, total NPV is lowered at the time of liquidation due to the land return. Private land acquisition-type require more initial costs. But the NPV at liquidation time increases with land disposal. To improve financial feasibility, acquisition-type should be preferred in high land-price area and rent-type should be preferred in low land-price area. Among influencing variables, the rate of increase in land price and the ratio of public and market rents turned out to be the most important. Although the ratio of public and market rents can be controllable, high ratio will cause the burden of tenants. Therefore, interest rate adjustment of National Housing Fund is more desirable.

Transparent Monopole Antenna on the Front Glass of an Automobile for FM Band (자동차 전면 글래스용 FM 대역 투명 모노폴 안테나)

  • Lee, Juhyung;Jung, Chang Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.7
    • /
    • pp.477-483
    • /
    • 2018
  • A transparent antenna designed on the front glass of an automobile operating in the FM broadcast band(88~108 MHz) is proposed. A transparent antenna designed on the front glass of the automobile to avoid space limitation is typically positioned as a roof-mounted shark-fin antenna. An antenna designed on the front glass can reasonably solve the problems of low reception sensitivity and radiated interference from antennas for other service bands. The front glass has a unique closed-line structure, and this structure causes the surface current to flow to the front glass's surroundings; thus, the first resonance is caused before the broadcast band. Through the use of this closed-line structure, the surface current distribution is controlled, and an antenna for which the first resonance is operating in the frequency-modulated(FM) band can be designed. Moreover, the use of a micro-metal-mesh film that is a transparent electrode, suitable for designing a radio frequency device, enables the antenna to minimize visual perception through its transparency. The measured reflection coefficient($S_{11}$) of the antenna is less than -6 dB, and the average peak gain is -0.9 dB in the FM band. Experiments show that the transparent antenna on the front glass offers both the space and design freedom required to develop future automotive antennas.

Design and Implementation of a Dynamic Instrumentation Framework based on Light-weight Dynamic Binary Translation (경량 동적 코드 변환 기법을 이용한 동적 인스트루멘테이션 기법 설계 및 구현)

  • Kim, Jeehong;Lee, Dongwoo;Kim, Inhyeok;Eom, Young Ik
    • Journal of KIISE
    • /
    • v.41 no.11
    • /
    • pp.892-899
    • /
    • 2014
  • Dynamic binary instrumentation is a code insertion technique for debugging a program without scattering its execution flow, while the program is running. Most dynamic instrumentations are implemented using dynamic binary translation techniques. Existing studies translated program codes dynamically by parsing the machine code stream to intermediate representation (IR) and then applying compilation techniques for IRs. However, they have high overhead during translation, which is a major cause of difficulty in applying the dynamic binary translation technique to the program which requires high responsiveness. In this paper, we introduce a light-weight dynamic binary instrumentation framework based on a novel dynamic binary translation technique which has low overhead while translating the program code. In order to reduce the translation overhead, our approach adopts a tabular-based address translation and exploits a translation bypassing scheme, which stores the translated address of a frequently called library function in advance. It then accesses the translated address and executes function codes without code translation when calling the function. Our experiment results demonstrated that the proposed approach outperforms the prior dynamic binary translation techniques from 2% up to 65%.

BPEL Engine Generator for adding New Functions to BPEL based on Attribute Grammar and Aspect-Oriented Programming (속성문법과 관점지향 프로그래밍 기법을 이용한 BPEL에 새로운 기능을 추가하는 BPEL 엔진 생성기)

  • Kwak, Dongkyu;Kim, Jongho;Choi, Jaeyoung
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.5
    • /
    • pp.209-218
    • /
    • 2015
  • BPEL is used in various domains since it can describe the flow of works according to conditions and rules, and it can call web services in service-oriented computing environments. However, new functions that are not provided by BPEL grammar are required in specific domains. Generally, when new functions are required, the domain-specific language should be newly defined and developed, which requires high development cost. In this regard, a new function needs to be defined and added instead of developing domain-specific language with the new functions added. However, such methods only allow an addition of a single function, and it is difficult to design and add new functions according to the needs. This paper defines XAS4B document, which extends the BPEL grammar function through XML schema in order to add new functions, and proposes BPEL engine generator that generates BPEL engine with the new functions added by processing the document. The XAS4B document enables the creation of a new grammar added to BPEL using XML schema. It also shows the process of adding new functions to BPEL engine using AspectJ, JAVA implementation of aspect-oriented programming. The proposed system can add new functions using AspectJ without modifying BPEL engine. This allows the provision of new functions at low cost in various domains.

Analysis of Building Energy by the Typical Meteorological Data (표준기상데이터(부산지역) 적용에 따른 건축물에너지 분석)

  • Park, So-Hee;Yoo, Ho-Chun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.202-207
    • /
    • 2008
  • Measures for coping with energy shortage are being sought all over the world. Following such a phenomenon, effort to use less energy in the design of buildings and equipment are being conducted. In particular, a program to evaluate the performance of a building comes into the spotlight. However. indispensable standard wether data to estimate the exact energy consumption of a building is currently unprepared. Thus, after appling standard weather data for four weather factors which were used in previous researches to Visual DOE 4.0, we compared it with the result of the existing data and evaluated them. For the monthly cooling and heating load of our target building, we used revised data for June, July, August, and September during which cooling load is applied. When not the existing data but the revised data was used, the research shows that an average of 14.9% increased in June, August, and September except for July. Also, in a case of heating load, the result by the revised data shows a reduction of an average of 11.9% from October to April during which heating load is applied. In particular, the heating loads of all months for which the revised data was used were more low than those of the existing data. In the maximum cooling and heating load according to load factors, the loads by residents and illumination for which the revised data was used were the same as those of the existing data, but the maximum cooling loads used by the two data have a difference in structures such as walls and roofs. Through the above results, the research cannot clearly grasp which weather data influences the cooling and heating load of a building. However, in the maximum loads by the change of weather data in four factors (dry-bulb temperature, web-bulb temperature, cloud amount, and wind speed) among 14 weather factors, the research shows that 5.95% in cooling load and 27.56% in heating load increased, and these results cannot be ignored. In order to make weather data for Performing energy performance evaluation for future buildings, the flow of weather data for the Present and past should be obviously grasped.

  • PDF

Application of CFD Simulation to Cooling System Design of Agricultural Products Processing Center Workplace (농산물산지유통센터 작업장의 냉방 설계를 위한 CFD 시뮬레이션 적용)

  • Kwon, Jin-Kyung;Lee, Sung-Hyun;Moon, Jong-Pil;Lee, Su-Jang;Kim, Keyong-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.195-202
    • /
    • 2010
  • Cooling air-conditioning of APC (Agricultural Products processing Center) workplace is important to improve the working environment in the summer season. As existing cooling systems for air-conditioning of whole workplace are inefficient because of their high equipment operating costs, relatively inexpensive cooling system is required. The objectives of this study were to simulate the thermal flow fields in APC workplace having the positive and negative pressure type fan and pad systems and spot cooling system by using CFD software (FLUENT, 6.2) and estimate the cooling effectiveness of respective cooling systems. The results showed that the negative pressure type fan and pad system was inappropriate for the present APC workplace because of excessive outside air influx from open gateway and the positive pressure type fan and pad system created relatively low temperature field but non-uniform velocity field at worker positions. The spot cooling system could supply cool air to worker positions with relatively constant air velocity and temperature.

Aerodynamic Characteristics and Galloping Possibility of Ice Accreted Transmission Conductors by Wind Tunnel Tests (풍동실험을 통한 착빙 가공송전선의 공력 특성 측정 및 갤러핑 발생 분석)

  • Lee, Dooyoung;Goo, Jaeryang;Park, Sooman;Kim, Donghwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.79-88
    • /
    • 2017
  • In this paper, the wind tunnel test for the measurement of aerodynamic characteristics of transmission conductors with asymmetric sections is described. A single conductor model and bundled conductor models with ice accreted shapes are tested both in steady and turbulent flow, and the aerodynamic coefficients are acquired. Transmission conductor galloping is a kind of wind-induced vibration which is characterized by primarily vertical oscillation with a very low frequency and a high amplitude. It is well known that transmission conductor galloping is generally caused by moderately strong, steady winds when a transmission conductor has an asymmetric cross-section shaped by accreted ice. Galloping should be considered from the design stage of overhead lines because it can cause severe wear and fatigue damage to attachments as well as transmission conductors. It is reported that there have been normally 20 events of galloping per year in Korea, which may be followed by serious consequences in the electric power system. Therefore, this research is performed to measure aerodynamic characteristics of ice accreted transmission conductors to understand and control transmission conductor galloping so that it would help to prevent unexpected failures and reduce the maintenance costs caused by galloping.

A Comparative Study on Power System Harmonics for Offshore Plants (해양플랜트 전력시스템의 고조파 비교분석에 관한 연구)

  • Kim, Deok-Ki;Lee, Won-Ju;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.900-905
    • /
    • 2016
  • The field of power system harmonics has been receiving a great deal of attention recently. This is primarily due to the fact that non-linear (or harmonic-producing) loads comprise an ever-increasing portion of what is handled at a typical industrial plant. The incidence rate of harmonic-related problems is low, but awareness of harmonic issues can still help increase offshore power plant system reliability. On the rare occasion that harmonics become a problem, this is either due to the magnitude of harmonics produced or power system resonance. This harmonic study used an electrical configuration for the offloading scenario of a Floating LNG (FLNG) unit, considering power load. This electrical network configuration is visible in the electrical network load flow study part of the project. This study has been carried out to evaluate the performance of an electric power system, focusing on the harmonic efficiency of an electrically driven motor system to ensure offshore plant safety. In addition, the design part of this study analyzed the electric power system of an FLNG unit to improve the safety of operation and maintenance.

A LQR Controller Design for Performance Optimization of Medium Scale Commercial Aircraft Turbofan Engine (II) (중형항공기용 터보팬 엔진의 성능최적화를 위한 LQR 제어기 설계 (II))

  • 공창덕;기자영
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.3
    • /
    • pp.99-106
    • /
    • 1998
  • The performance of the turbofan engine, a medium scale civil aircraft which has been developing in Rep. of Korea, was analyzed and the control scheme for optimization the performance was studied. The dynamic and real-time linear simulation was performed in the previous study The result was that the fuel scedule of the step increase overshoot the limit temperature(3105 $^{\cire}R$) of the high pressure turbine and got small surge margine of the high pressure compressor. Therefore a control scheme such as the LQR(Linear Quadratic Regulator) was applied to optimizing the performance in this studies. The linear model was expected for designing controller and the real time linear model was developed to be closed to nonlinear simulation results. The system matrices were derived from sampling operating points in the scheduled range and then the least square method was applied to the interpolation between these sampling points, where each element of matrices was a function of the rotor speed. The control variables were the fuel flow and the low pressure compressor bleed air. The controlled linear model eliminated the inlet temperature overshoot of the high pressure turbine and obtained maximum surge margins within 0.55. The SFC was stabilized in the range of 0.355 to 0.43.

  • PDF

Performance Characteristics of the 300 MW Integrated Gasification Combined Cycle Plant according to Ambient Temperature (대기온도에 따른 300 MW 석탄가스화복합발전 성능특성)

  • Kim, Young-Mook;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.14 no.3
    • /
    • pp.29-34
    • /
    • 2018
  • In this study, the output and thermal efficiency of Taean Integrated Gasification Combined Cycle Plant were calculated by using the manufacturer's basic design data and the performance correction factor for each atmospheric temperature, and the actual performance was measured at summer and winter representative points. The results were compared with the calculated values to verify their validity. The thermal efficiency is the highest at around $15^{\circ}C$ and lower at lower temperature and higher temperature. This is similar to that of natural gas Combined Cycle Power Plant, but the thermal efficiency has drastically decreased due to the increase of power consumption of the air separation unit at relatively high temperature. The output is highest in the range of 5 to $15^{\circ}C$, and is kept almost constant at below $5^{\circ}C$ and declines above $15^{\circ}C$. The reason why the output does not increase at low temperatures is that the torque limit of the shaft is activated by the increase of the flow rate due to the nitrogen injection of the gas turbine combustor. In order to improve the performance in the future, efforts should be made to improve the power generation output and to reduce the power consumption of the air separation unit in summer.

  • PDF