• Title/Summary/Keyword: design formula

Search Result 1,298, Processing Time 0.028 seconds

A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

  • Park, Su-Hee;Choi, Sung-Mo;Chung, Kyung-Soo
    • Steel and Composite Structures
    • /
    • v.8 no.6
    • /
    • pp.491-510
    • /
    • 2008
  • This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of this comparison showed that the test and analysis results for specimens SAH1, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative than the AIJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.

Bearing Capacity of Mid & Small dia Hellical Pile (중·소구경 헬리컬 파일의 지지력 특성)

  • Park, Jong-Bae;Park, Yong-Boo;Kwon, Young-Hwan
    • Land and Housing Review
    • /
    • v.11 no.2
    • /
    • pp.75-86
    • /
    • 2020
  • As the urban regeneration project and the old housing maintenance project are actively progressing in Korea, small-scale building construction is being carried out in downtown areas. Small buildings in the downtown area are constructed on about 4 to 10 floors, and since they are carried out in small units in residential areas, it is difficult to enter large equipment to construct existing piles, and it is more vulnerable to complaints about noise and vibration. in this study, helical piles suitable for urban areas or small sites where it is difficult to enter large equipment, such as noise and vibration. Reliability analysis was performed on the results of the static load tests and dynamic load tests conducted at the LH site and the bearing capacity calculated by the hydrostatic method and the empirical formula (N value). As a result of comparing and analyzing the design formula and the results of static load test and dynamic load tests, the correlation between the design formula of the bored pile (Road bridge design standard) formula using N value and the design formula by the modified Davisson method frequently used by method commonly European helical file practitioners.

Reverse Engineering of an Aspheric Lens Curvature (역공학을 이용한 비구면 렌즈의 형상 설계 정보 추출)

  • Kim, Han-Seob;Jeon, Jeong-Up;Park, Kyu-Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.10 s.175
    • /
    • pp.144-149
    • /
    • 2005
  • This study presents the method of extracting shape design data on any aspheric lens by reverse engineering. The design formula fur aspheric lenses is needed in almost all of the design, manufacture and measuring processes. The difficulty in designing the lens lies in the fact that it uses a complex formula for the aspheric surface, and many of the preliminary design values must be selected before actually inserting them into the formula. If the values could be extracted from an aspheric lens for which the structural design information is unknown and used in designing other lenses of similar characteristics, the difficulties in designing and measuring aspheric lens could be reduced. Therefore, in this study, the concept of reverse engineering was applied to demonstrate the method of extracting shape design information of aspheric lens from an arbitrary aspheric lens.

Application of Experimental Design to Optimize Vitamin C-90 Tabletting Performance

  • Chang, Kuei-Tu
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.67-77
    • /
    • 1994
  • The RMS statistical approach has demonstrated its potential in developing pharmaceutical dosage forms and in improving tabletting performance. Using an optimized formula, the tabletting performances of vitamin C-90 such as compressibility, disintegration time, lubrication and friability are significantly enhanced when compared with the performance of a traditional test formula. More important, this method also enables us to serve our customers better. Any customized modification of a suggested formula or any technical problem related performance etc. can be readily resolved by simple examination of the models.

  • PDF

Channel Design of Decanter-Type Centrifuge (I) - Particles′ Suspension and the Channel Size (원심분리기의 채널 설계(I) - 입자의 부유문제와 채널 크기)

  • 서용권
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.148-155
    • /
    • 2003
  • In this paper, based on the concept of solid particles' hovering problem the working formula for the channel design of a Decanter-type centrifuge were derived. The Shields' diagram and its curve-fitting formula were used in determining the criterion of particle size for the sediment. By using these formula the designer can determine the sectional configuration of the channel, such as the liquid depth, the normal pitch of the screw-blade arrangement and the bowl diameter.

Experimental study on the compressive stress dependency of full scale low hardness lead rubber bearing

  • Lee, Hong-Pyo;Cho, Myung-Sug;Kim, Sunyong;Park, Jin-Young;Jang, Kwang-Seok
    • Structural Engineering and Mechanics
    • /
    • v.50 no.1
    • /
    • pp.89-103
    • /
    • 2014
  • According to experimental studies made so far, design formula of shear characteristics suggested by ISO 22762 and JEAG 4614, representative design code for Lead Rubber Bearing(LRB) shows dependence caused by changes in compressive stress. Especially, in the case of atypical special structure, such as a nuclear power structure, placement of seismic isolation bearing is more limited compared to that of existing structures and design compressive stress is various in sizes. As a result, there is a difference between design factor and real behavior with regards to shear characteristics of base isolation device, depending on compressive stress. In this study, a full-scale low hardness device of LRB, representative base isolation device was manufactured, analyzed, and then evaluated through an experiment on shear characteristics related to various compressive stresses. With design compressive stress of the full-scale LRB (13MPa) being a basis, changes in shear characteristics were analyzed for compressive stress of 5 MPa, 10 MPa, 13 MPa, 15 MPa, and 20 MPa based on characteristics test specified by ISO 22762:2010 and based on the test result, a regression analysis was made to offer an empirical formula. With application of proposed design formula which reflected the existing design formula and empirical formula, trend of horizontal characteristics was analyzed.

Design and Manufacture of a Hand-made Vehicle Based on a Formula (포뮬러 형태의 자작자동차 설계 및 제작)

  • Lee, Soo Jin;Jeong, Wonsun;Kim, Geunbi;Kim, Seong Keol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.5
    • /
    • pp.568-575
    • /
    • 2015
  • A hand-made vehicle with a formula (VF-1) was designed and manufactured with the aim of realizing a lightweight and high-performance vehicle. The driver's body weight and stiffness of the frame were considered. The vehicle was equipped with a one-cylinder Exiv 250 engine with intake manifold potting for realizing weight reduction, high performance, and low cost. The suspension system for the formula was designed through the analyses and tests of vehicle motion and equipment. In a steering system, anti-Ackerman geometry was introduced to increase the transverse force during cornering. A full electric paddle shift system was adopted to decrease the braking distance. For protection against the distortion and warping of the frame, tungsten inert gas (TIG) welding technology was used.

Estimation of stormwater interception ratio for evaluating LID facilities performance in Korea

  • Choi, Jeonghyeon;Lee, Okjeong;Lee, Jeonghoon;Kim, Sangdan
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.19-28
    • /
    • 2019
  • To minimize the impact of urbanization, accurate performance evaluation of Low Impact Development (LID) facilities is needed. In Korea, the method designed to evaluate large-scale non-point pollution reduction facilities is being applied to LID facilities. However, it has been pointed out that this method is not suitable for evaluating the performance of relatively small-scale installed LID facilities. In this study, a new design formula was proposed based on the ratio of LID facility area and contributing drainage area, for estimating the Stormwater Interception Ratio (SIR) for LID facilities. The SIR was estimated for bio-retentions, infiltration trenches and vegetative swales, which are typical LID facilities, under various conditions through long-term stormwater simulation using the LID module of EPA SWMM. Based on the results of these numerical experiments, the new SIR formula for each LID facility was derived. The sensitivity of the proposed SIR formula to local rainfall properties and design variables is analysed. In addition, the SIR formula was compared with the existing design formula, the Rainfall Interception Ratio (RIR).

Ergonomic Improvement of Operation Console for Pilot Aptitude Research Equipment (조종적성 검사/연구 장비 운용 Console의 인간공학적 개선)

  • Kim, Sungho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.42-49
    • /
    • 2018
  • Pilot Aptitude Research Equipment (PARE) is a simulator developed to measure or research pilot aptitude and train for student pilots. Design of an ergonomic PARE operation console is required to operate the equipment effectively. This study carried out five steps : (S1) operator questionnaire survey, (S2) anthropometric design formula development, (S3) usability evaluation, (S4) improvement design, and (S5) validation considering both Physical User Interface (PUI) and Graphic User Interface (GUI) of PARE operation console. The operator questionnaire surveyed needs for each PUI and GUI part of the console from two PARE actual operators. In terms of PUI, the anthropometric design formula was developed by using design variables, body dimensions, target population characteristics, and reference posture related to the PARE console. In terms of GUI, the usability evaluation was conducted by three usability testing experts with a 7-point scale (1 : very low, 4 : neutral, 7 : very high) on GUI of the PARE operation console by seven usability criteria. The improved PARE operation console was designed to reflect the optimal values of design variables calculated from design formula, the results from usability testing, and the operator's needs. The improvement effect was observed by 20 people who had experience with the PARE operation console. As a result of the validation, monitor visibility and cockpit visibility for the improved PUI design and visibility and efficiency for the improved GUI design were significantly increased by more than 90% respectively. The improved design of the PARE operation console in this study can contribute to enhance operation performance of the PARE.

Preliminary design and cost estimation of helicopters (회전익 항공기의 기본설계 및 가격예측 연구)

  • Lee, Choong-Yun;Ko, Kwang-Ho;Jung, Sung-Nam;Yu, Yung-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.4
    • /
    • pp.309-314
    • /
    • 2010
  • In this work, the helicopter price estimation formula from Harris & Scully is revised and updated for more accurate prediction of the current prices of helicopters which can be applied in the preliminary design stage. As many as 74 helicopter price and sizing data after the year 1997 are newly included to the out-dated coefficients in the cost estimation formula. In addition, the updated price estimation formula is added to Tishchenko's preliminary sizing method for price consideration in the preliminary design stage. Sikorsky's S-76C+ helicopter is used along with other various helicopters for comparison and validation of the sizing code as well as the new updated price estimation formula.