• Title/Summary/Keyword: design forces

Search Result 2,246, Processing Time 0.036 seconds

Predicting the seismic behavior of torsionally-unbalanced RC building using resistance eccentricity

  • Abegaz, Ruth A.;Kim, In-Ho;Lee, Han Seon
    • Structural Engineering and Mechanics
    • /
    • v.83 no.1
    • /
    • pp.1-17
    • /
    • 2022
  • The static design approach in the current code implies that the inherent torsional moment represents the state of zero inertial torsional moments at the center of mass (CM). However, both experimental and analytical results prove the existence of a large amount of the inertial torsional moment at the CM. Also, the definition of eccentricity by engineers, which is referred to as the resistance eccentricity, is defined as the distance between the center of mass and the center of resistance, which is conceptually different from the static eccentricity in the current codes, defined as the arm length about the center of rotation. The difference in the definitions of eccentricity should be made clear to avoid confusion about the torsion design. This study proposed prediction equations as a function of resistance eccentricity based on a resistance eccentricity model with advantages of (1) the recognition of the existence of torsional moment at the CM, (2) the avoidance of the confusion by using resistance eccentricity instead of the design eccentricity, and (3) a clear relationship of applied inertial forces at the CM and resisting forces. These predictions are compared with the seismic responses obtained from time-history analyses of a five-story building structure under moderate and severe earthquakes. Then, the trend of the resistance eccentricity corresponding to the maximum edge drift is investigated for elastic and inelastic responses. The comparison given in this study shows that these prediction equations can serve as a useful reference for the prediction in both the elastic and the inelastic ranges.

Performance based design approach for multi-storey concentrically braced steel frames

  • Salawdeh, Suhaib;Goggins, Jamie
    • Steel and Composite Structures
    • /
    • v.20 no.4
    • /
    • pp.749-776
    • /
    • 2016
  • In this paper, a Performance Based Design (PBD) approach is validated for multi-storey concentrically braced frame (CBF) systems. Direct Displacement Based Design (DDBD) procedure is used and validated by designing 4- and 12-storey CBF buildings. Nonlinear time history analysis (NLTHA) is used to check the performance of the design methodology by employing different accelerograms having displacement spectra matching the design displacement spectrum. Displacements and drifts obtained from NLTHA are found to fall within the design displacement limits used in the DDBD procedure. In NLTHA, both tension and compression members are found to be resisting the base shear, $F_b$, not only the tension members as assumed in the design methodology and suggested by Eurocode 8. This is the reason that the total $F_b$ in NLTHA is found to be greater than the design shear forces. Furthermore, it is found that the average of the maximum ductility values recorded from the time history analyses for the 4-and 12-storey buildings are close to the design ductility obtained from the DDBD methodology and ductility expressions established by several researchers. Moreover, the DDBD is compared to the Forced Based Design (FBD) methodology for CBFs. The comparison is carried out by designing 4 and 12-storey CBF buildings using both DDBD and FBD methodologies. The performance for both methodologies is verified using NLTHA. It is found that the $F_b$ from FBD is larger than $F_b$ obtained from DDBD. This leads to the use of larger sections for the structure designed by FBD to resist the lateral forces.

Introduction of the Capacity Design Methodology in the Building Standard Law of Japan (개정된 일본 내진설계기준의 한계내력계산법의 소개)

  • 전대한;노필성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.861-866
    • /
    • 2002
  • This manuscript introduces the Capacity Design Methodology in the Building Standard Law of Japan revised at 2000, June. The Building Standard Law of Japan was revised into the performance-based design format following the trend of international. The structural performance was evaluated for two limiting states; soundness limit state and safety limit state. The design seismic forces were determined on taking into consideration (a)the properties of the planned building, (b)amplification by local surfaces geology, and (c)soil-structure interaction.

  • PDF

Effect of Effective Compressive Strength of Concrete Strut on Structural Concrete Design (콘크리트 스트럿의 유효강도가 콘크리트 부재의 설계에 미치는 영향)

  • 윤영묵;석철호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.241-246
    • /
    • 2000
  • In the strut-tie model design of structural concrete, the importance of the effective strength of concrete strut has been overlooked by many practitioners. The authors believe that the effective strength of concrete strut is an important factor not only in determining steel tie forces but also in verifying the nodal zone strength and geometric compatibility condition of a selected strut-tie model. This study evaluate the effect of the effective strength of concrete strut on structural concrete design by applying the different effective strut strengths to the strut-tie model design of a post-tensioned anchorage zone and a continuous concrete deep beam.

  • PDF

A Simple Design Method of Un-reinforced Masonry Wall (비보강 조적 벽체의 간이 설계법(設計法))

  • Yoon, Myung-Ho;Cho, Byoung-Hoo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.2 no.1
    • /
    • pp.45-51
    • /
    • 2002
  • The masonry structure has been widely used as the dwelling house structure in our country for a long time. The masonry structure is weak in the lateral forces such as strong wind and earthquake. But there is no regulation for it in the domestic aseismic design codes. The purpose of this study is to suggest a simple design method of un-reinforced masonry wall.

  • PDF

Development of Drift Design Method for High-rise Buildings Considering Characteristics of Member Forces (부재력 특성을 고려한 설계변수를 사용한 고층건물 변위조절설계법 개발)

  • 서지현;박효선
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.2
    • /
    • pp.215-222
    • /
    • 2004
  • Drift design methods using resizing techniques have been presented as a practical drift control methods of high-rise buildings. Most drift design methods using the resizing techniques have adopted the cross-sectional area as the design variables for all structural members in a structure. However, the cross-sectional area is not always governing sectional property for the structural members, but the governing sectional property of each member is dependent on the characteristics of member forces. In this paper, a drift design method using the sectional property related to the governing displacement participation factor as the design variable of each member is presented and applied to the drift design of 20-story steel frame-shear wall system. It can be noted from example test that drift design method considering member characteristics shows similar or somewhat better results in the view point of structural weights and the accuracy of displacement estimation.

Design of Six-Component F/T Sensor with Flexible Fixed Ends (유연한 고정단을 가진 6축 F/T 센서의 설계)

  • Lee, Bong-Hee;Joo, Jin-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.771-780
    • /
    • 2010
  • This paper describes the design process of a six-component force/torque (F/T) sensor. The new six-component F/T sensor having leaf spring ends has been developed using a cross beam structure as the basic sensing element. Fundamental strain analysis of both ends fixed beam having a leaf spring structure is performed by finite element analysis. In order to obtain similar output sensing strains from the six component loads and minimize coupling strains, the optimal location of strain gages is determined and the strain gages are connected so that the bridge circuits with four strain gages would be balanced. Using leaf spring ends instead of rigid fixed ends, remarkable increment in output sensing strain can be achieved for two component forces. Several modifications in design result in a similar sensing strain of approximately $400\;{\mu}m/m$ for the six-component forces and moments, and a reduced coupling strain of $0\;{\mu}m/m$ between the forces and moments.

Comparison of Modeling Methods of a Pile Foundation in Seismic Analysis of Bridge Piers (교각의 내진설계를 위한 말뚝기초의 모델링 기법 비교)

  • 김나엽;김성렬;전덕찬;김명모
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.6
    • /
    • pp.25-32
    • /
    • 2002
  • In the seismic designing of bridges, the pile foundation of bridge piers generally have been modeled to have a fixed end for its convenience and conservative designing. The fixed-end assumption, however, produces very conservative results in terms of the pier forces. Therefore, many other design methods are evolved to consider the flexibility of the pile foundation. In this study, the response spectrum analysis was performed for a bridge pier having a pile foundation. The shear force, moment, and displacement, which occurred at the pier column under an earthquake loading, were compared to analyze the effects of the modeling method, soil condition and the input earthquake response spectrum. In most cases, the fixed-end model gives larger design forces than flexible foundation models. However, when a long period earthquake is applied to the bridge pier on a soft clay foundation, it is found that the flexible foundation models give larger design forces than the fixed-end model. In the end, the reliability of several flexible foundation models was verified by comparing their results with those of a numerical analysis that considers the soil-structure interaction phenomenon in a rigorous manner.

Evaluation of Fluid Forces Acting on Offshore Structures Placed in the Vicinity of Underwater Shoal (수중 천퇴 인근에 설치된 해양구조물에 작용하는 유체력 결정에 대한 고찰)

  • Chun, In-Sik;Min, In-Ki;Sim, Jae-Seol
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.2
    • /
    • pp.136-145
    • /
    • 2007
  • When waves propagating over an underwater shoal break at the top of the shoal, wave heights are drastically decreased in the downstream breaking zone, but a secondary current shooting downstream with strong velocity can be induced by the breaking waves themselves. In the case that an offshore structure is placed in the breaking zone, the estimation of wave farce purely based on the visible wave height may cause an under-design of the structure. Thus, for the safe design of the structure, the breaking wave induced current should be necessarily considered in the comprehensive estimation of design load. In the present study, Boussinesq equation model to calculate the wave height distribution and breaking wave induced current was set up and applied to the scheme of a hydraulic model test previously undertaken. Based on the results of the Boussinesq model, fluid forces acting on the model structure were calculated and compared with the experimental results. The importance of the breaking wave induced current was quantitatively assessed by comparing fluid forces with or without current.

A Study on Container Securing System for Optimum Arrangement (최적 적재를 위한 컨테이너 시큐어링 시스템 개발에 관한 연구)

  • Shin, Sang-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.27 no.4
    • /
    • pp.397-402
    • /
    • 2003
  • Generally, container arrangement has been carried out based on the Classification guidelines. However, guidelines provide only container securing forces for the given container arrangement and Classification requirements of the forces. In order to design container arrangement additional information is needed such as container securing forces and arrangement that accounts for lashing bridges, vertical lashing, vertical center of gravity (VCG), and maximum stack weight. Trial and error method using the existing guidelines requires excessive amount of calculation time and cannot provide accurate results of the calculations. In order to fulfill this need, a new container securing system has been established based on the equilibrium conditions that include lashing bridges and vertical lashing. An optimization algorithm has been developed for the new system since current optimization methods such as genetic algorithms and evolution strategies are unsuitable for the container securing problems, which involve equality constraint. Design variables are container weights of tier and objective function is either total container weight or VCG of a stack. The newly developed system provides optimum arrangement of containers for both maximum stack weight and maximum VCG. It also greatly reduces time for designing container arrangement.