• Title/Summary/Keyword: design comparison

Search Result 6,432, Processing Time 0.035 seconds

Detailing in the Pi(${\pi}$)-Shaped RC Rahmen Bridge According to the Design Methods (설계방법에 따른 ${\pi}$형 RC 라멘교의 배근상세)

  • We, Jeung-Bok;Lee, Seung-Hun;Eom, Jang-Sub;Jin, Chi-Sub
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.213-216
    • /
    • 2006
  • The designer has difficulty due to inadequacy of provisions in the domestic design code and lack of understanding for behavior of D-region. The reinforced concrete pi(${\pi}$)-shaped RC rahmen bridge consists of various failure mechanisms as the crushing or splitting from compression concrete, and shearing failure under the loading plate. However, predicting those failure mechanisms is very difficult. In this study, the pi(${\pi}$)-shaped RC rahmen bridge is analyzed and designed by using strut-tie model. Adequacy for the application of strut-tie model is verified by comparison with the way used in current design practice. As a result that designing the structures should be maked a comparison between strut-tie model and current conventional design method.

  • PDF

Design of Wound Rotor Synchronous Machine for ISG and Performance Comparison with Interior Permanent Magnet Synchronous Machine (ISG용 권선형 동기기의 설계 및 IPMSM과 특성 비교)

  • Lee, Dongsu;Jeong, Yun-Ho;Jung, Sang-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.37-42
    • /
    • 2013
  • This paper deals with Wound Rotor Synchronous Motor (WRSM) purposely designed for Integrated Starter and Generator (ISG) installed in 42V automotive electrical system. Not only design objective and specifications of WRSM, but its adaptive design to minimize torque ripple and back-EMF Total Harmonics Distortion (THD) are considered. Furthermore, design characteristics of designed prototype have been investigated numerically in terms of torque, back EMF, loss, and efficiency, which are verified by performance comparison with Interior Permanent Magnet Synchronous Machine based on Finite Element Analysis (FEA).

Development of a Batch-mode-based Comparison System for 3D Piping CAD Models of Offshore Plants (Aveva Marine과 SmartMarine 3D간의 해양 플랜트 3D 배관 CAD 모델의 배치모드 기반 비교 시스템 개발)

  • Lee, Jaesun;Kim, Byung Chul;Cheon, Sanguk;Cho, Mincheol;Lee, Gwang;Mun, Duhwan
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.1
    • /
    • pp.78-89
    • /
    • 2016
  • When a plant owner requests plant 3D CAD models in the format that a shipbuilding company does not use, the shipyard manually re-models plant 3D CAD models according to the owner's requirement. Therefore, it is important to develop a technology to compare the re-modeled plant 3D CAD models with original ones and to quantitatively evaluate similarity between two models. In the previous study, we developed a graphic user interface (GUI)-based comparison system where a user evaluates similarity between original and re-modeled plant 3D CAD models for piping design at the level of unit. However, an offshore plant consists of thousands of units and thus a system which compares several plant 3D CAD models at unit-level without human intervention is necessary. For this, we developed a new batch model comparison system which automatically evaluates similarity of several unit-level plant 3D CAD models using an extensible markup language (XML) file storing file location and name data about a set of plant 3D CAD models. This paper suggests system configuration of a batch-mode-based comparison system and discusses its core functions. For the verification of the developed system, comparison experiments for offshore plant 3D piping CAD models using the system were performed. From the experiments, we confirmed that similarities for several plant 3D CAD models at unit-level were evaluated without human intervention.

A COMPARISON STUDY OF SPACE RADIATION DOSE ANALYSIS PROGRAMS: SPENVIS SECTORING TOOL AND SIGMA II

  • Chae Jongwon
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.347-350
    • /
    • 2004
  • A space radiation analysis has been used to evaluate an ability of electronic equipment boxes or spacecrafts to endure various radiation effects, so it helps design thicknesses of structure and allocate components to meet the radiation requirements. A comparison study of space radiation dose analysis programs SPENVIS Sectoring Tool (SST) and SIGMA II is conducted through some structure cases, simple sphere shell, box and representative satellite configurations. The results and a discussion of comparison will be given. A general comparison will be shown for understanding those programs. The both programs use the same strategy, solid angle sectoring with ray-tracing method to produce an approximate dose at points in representative simple and complex models of spacecraft structures. Also the particle environment data corresponding to mission specification and radiation transport data are used as input data. But there are distinctions between them. The specification of geometry model and its input scheme, the assignment of dose point and the numbers, the prerequisite programs and ways of representing results will be discussed. SST is a web-based interactive program for sectoring analysis of complex geometries. It may be useful for a preliminary dose assessment with user-friendly interfaces and a package approach. SIGMA II is able to obtain from RSICC (Radiation Safety Information Computational Center) as a FOR-TRAN 77 source code. It may be suitable for either parametric preliminary design or detailed final design, e.g. a manned flight or radiation-sensitive component configuration design. It needs some debugs, recompiling and a tedious work to make geometrical quadric surfaces for actual spacecraft configuration, and has poor documentation. It is recommend to vist RSICC homepage and GEANT4/SSAT homepage.

  • PDF

Comparison of Design Standards for Seismic Design of Steel Liquid Storage Tanks (강재 액체저장탱크의 내진설계를 위한 설계기준 분석)

  • Bae, Doobyong;Park, Jang Ho;Oh, Chang Kook
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.195-202
    • /
    • 2016
  • In this study, it is carried out to analyze the international design standards such as Eurocode 8, API 650, NZSEE and etc for the seismic design of steel liquid storage tanks. From the comparison and analysis, the data for the required parameters and factors are provided for the establishment of Korean seismic design standard for steel liquid storage tanks. The simplified mechanical models have been presented for the seismic design of steel liquid storage tanks in all design standards and the parameters of mechanical models in design standards have similar values. Although the models for the seismic design of steel liquid storage tanks are similar in design standards, design approaches are given differently in accordance with the design methods, allowable stress design or limit state design. Therefore it is not easy to compare seismic forces presented in design standards directly. After comparison of design standards, it is concluded that establishment of Korean design standard for the seismic design of steel liquid storage tanks is necessary.

Optimum Design of Retaining Wall with Seismic Constraints (내진제약조건(耐震制約條件)을 갖는 옹벽(擁壁)의 최적설계(最適設計))

  • Kim, Kee-Dae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.2
    • /
    • pp.95-102
    • /
    • 2003
  • In this paper, optimum design is considered over the retaining wall with seismic constraints. The sequential linear programming method(SLP) is used as a rational approach to this optimum design. To make a comparison between the seismic design and the normal design, retaining wall with 4~7m height were adopted. It is shown that the seismic design is more expensive (over 30%) than the normal design for the construction cost.

  • PDF