• 제목/요약/키워드: desalination

검색결과 479건 처리시간 0.024초

Classification of Soil Desalination Areas Using High Resolution Satellite Imagery in Saemangeum Reclaimed Land

  • Lee, Kyung-Do;Baek, Shin-Chul;Hong, Suk-Young;Kim, Yi-Hyun;Na, Sang-Il;Lee, Kyeong-Bo
    • 한국토양비료학회지
    • /
    • 제46권6호
    • /
    • pp.426-433
    • /
    • 2013
  • This study was aimed to classify soil desalination area for cultivation using NDVI (Normalized difference vegetation index) of high-resolution satellite image because the soil salinity affects the change of plant community in reclaimed lands. We measured the soil salinity and NDVI at 28 sites in the Saemangeum reclaimed land in June 2013. In halophyte and non-vegetation sites, no relation was found between NDVI and soil salinity. In glycophyte sites, however, we found that the soil salinity was below 0.1% and NDVI ranged from 0.11 to 0.57 which was greater than the other sites. So, we could distinguish the glycophyte sites from the halophyte sites and non-vegetation, and classify the area that soil salinty was below 0.1%. This technique could save the time and labor to measure the soil salinity in large area for agricultural utilization.

Sensitivity analysis and Taguchi application in vacuum membrane distillation

  • Upadhyaya, Sushant;Singh, Kailash;Chaurasia, Satyendra Prasad;Baghel, Rakesh;Singh, Jitendra Kumar;Dohare, Rajeev Kumar
    • Membrane and Water Treatment
    • /
    • 제9권6호
    • /
    • pp.435-445
    • /
    • 2018
  • In this work, desalination experiments were performed on vacuum membrane distillation (VMD). Process parameters such as feed flow rate, vacuum degree on permeate side, feed bulk temperature and feed salt concentration were optimized using sensitivity analysis and Taguchi method. The optimum values of process parameters were found to be 2 lpm of feed flow rate, $60^{\circ}C$ of feed bulk temperature, 5.5 kPa of permeate-side pressure and 5000 ppm of salt concentration. The permeate flux at these conditions was obtained as $26.6kg/m^2{\cdot}hr$. The rejection of salt in permeate was found to be 99.7%. The percent contribution of various process parameters using ANOVA results indicated that the most important parameter is feed bulk temperature with its contribution of 95%. The ANOVA results indicate that the percent contribution of permeate pressure gets increased to 5.384% in the range of 2 to 7 kPa as compared to 0.045% in the range of 5.5 to 7 kPa.

하수방류수의 전처리 조건별 FO막의 운전성능평가 (Evaluation of FO membrane performance for each type of pre-treatment from WWTP secondary effluents)

  • 정준원;김지훈;김건엽;박준영;김형수;김형숙
    • 상하수도학회지
    • /
    • 제30권2호
    • /
    • pp.131-137
    • /
    • 2016
  • The development of alternative water resources has emerged as an effective method for solving drought of water resources due to extreme weather and increase in water consumption. Recently, in Korea, there has been active research on reverse osmosis desalination technology, wastewater reuse using forward osmosis membranes, and the forward osmosis(FO)-reverse osmosis(RO) hybrid process combining these two technologies. In this study, the basic performance of FO membranes manufactured by three domestic and international manufactures such as Microfilter Co., Ltd., Toray Chemical Korea Inc., and Hydration Technologies Inc., were investigated for wastewater reuse. In addition, as an experiment to select feed solution, the selected membranes were operated 48 consecutive hours using three secondary effluents pretreated by the UF membrane with a pore size of $0.1{\mu}m$ and auto strainer with pore sizes of $1{\mu}m$ and $100{\mu}m$ as feed solution. Although there was not much difference in the operating performance. Thus, the treated water using the $100{\mu}m$ auto strainer was selected as feed solution applied to the assessment.

Advanced Membrane Systems for Seawater Desalination. Kinetics of Salts Crystallization from RO Brines Promoted by Polymeric Membranes

  • Curcio, Efrem;Obaidani, Sulaiman Al;Macedonio, Francesca;Profio, Gianluca Di;Gualtieri, Silvia;Drioli, Enrico
    • 멤브레인
    • /
    • 제17권2호
    • /
    • pp.93-98
    • /
    • 2007
  • The reliability of innovative membrane contactors technology (i.e. Gas/Liquid Membrane Contactors, Membrane Distillation/Crystallization) is today increasing for seawater desalination processes, where traditional pressure-driven membrane separation units are routinely operated. Furthermore, conventional membrane operations can be integrated with membrane contactors in order to promote possible improvements in process efficiency, operational stability, environmental impact, water quality and cost. Seawater is the most abundant aqueous solution on the earth: the amount of dissolved salts covers about 3% of its composition, and six elements (Na, Mg, Ca, K, Cl, S) account for more than 90% of ionic species. Recent investigations on Membrane Distillation-Crystallization have shown the possibility to achieve significant overall water recovery factors, to limit the brine disposal problem, and to recover valuable salts (i.e. calcium sulphate, sodium chloride, magnesium sulphate) by combining this technology with conventional RO trains. In this work, the kinetics of $CaSO_4{\cdot}2H_2O,\;NaCl\;and\;MgSO_4{\cdot}7H_2O$ crystallization is experimentally investigated in order to improve the design of the membrane-based crystallization unit.

Dynamic Economic Dispatch and Control of a Stand-alone Microgrid in DongAo Island

  • Ma, Yiwei;Yang, Ping;Guo, Hongxia;Wang, Yuewu
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1432-1440
    • /
    • 2015
  • A dynamic economic dispatch and control method is proposed to minimize the overall generating cost for a stand-alone microgrid in DongAo Island, which is integrated with wind turbine generator, solar PV, diesel generator, battery storage, the seawater desalination system and the conventional loads. A new dispatching strategy is presented based on the ranking of component generation costs and two different control modes, in which diesel generator and battery storage alternate to act as the master power source to follow system power fluctuation. The optimal models and GA-based optimization process are given to minimize the overall system generating cost subject to the corresponding constraints and the proposed dispatch strategy. The effectiveness of the proposed method is verified in the stand-alone microgrid in DongAo Island, and the results provide a feasible theoretical and technical basis for optimal energy management and operation control of stand-alone microgrid.

이중관 삼중흐름 열교환에 의한 LNG 기화시스템의 열적 해석 (Thermal Analysis of Double-tube Triple-flow LNG Vaporization System)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권7호
    • /
    • pp.839-844
    • /
    • 2003
  • As sea water is being used as only heat source of LNG open rack vaporizer, serious problem has been risen in LNG terminal by the lack of heating energy source for LNG vaporization due to the temperature drop of sea water in winter. In this paper the new double-tube triple-flow(TRIDEX) vaporizer was suggested to solve the problem and the system was thermally analysed. LPG(liquefied petroleum gas) and sea water were introduced as the heat sources for LNG TRIDEX vaporizer. The flow patterns of TRIDEX vaporizer are as follows: LNG flow in the annular space, PG(petroleum gas) flow in the inner tube, and sea water flow in the outside of the double pipe. The overall LNG vaporization system was consisted of TRIDEX vaporizer, LPG vaporizer and PG heater. LPG in TRIDEX was directly dispersed in the sea water desalination unit, so that LPG turns to be gas phase for the reuse in TRIDEX vaporizer. New TRIDEX vaporizer system for LNG evaporation was analysed as much more effective than the present single tube one in the case of colder temperature of sea water in winter.

역삼투막 공정에서 Direct Osmosis의 역방향 Flux 기초특성 (Characteristics of Reverse Flux by using Direct Omosis in RO Membrane Process)

  • 강일모;독고석
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.399-405
    • /
    • 2011
  • In a desalination technology using RO membranes, chemical cleaning makes damage for membrane surface and membrane life be shortened. In this research cleaning technology using direct osmosis (DO) was introduced to apply it under the condition of high pH and high concentration of feed. When the high concentration of feed is injected to the concentrate side after release of operating pressure, then backward flow occurred from treated water toward concentrated for osmotic pressure. This flow reduces fouling on the membrane surface. Namely, flux of DO was monitored under pH 3, 5, 10 and 12 conditions at feed concentrations of NaCl 40,000 mg/L, 120,000 mg/L and 160,000 mg/L. As a result, DO flux in pH 12 increased about 21% than pH 3. DO cleaning was performed under the concentrate NaCl 160,000 mg/L of pH 12 during 20 minutes. Three kinds of synthetic feed water were used as concentrates. They consisted of organic, inorganic and seawater; chemicals of SiO2 (200 mg/L), humic acid (50 mg/L) sodium alginate (50 mg/L) and seawater. As a result, fluxes were recovered to 17% in organic fouling, 15% in inorganic fouling and 14% of seawater fouling after cleaning using DO under the condition of concentrate NaCl 160,000 mg/L of pH 12.

정수압방식 동력회수장치의 구동동력 절감량 해석 (An analysis on power regeneration of hydrostatic pressure exchanger)

  • 함영복;최준혁;정헌술;박상진;박중호;윤소남
    • 유공압시스템학회논문집
    • /
    • 제4권3호
    • /
    • pp.7-12
    • /
    • 2007
  • This paper presents an energy saving hydrostatic pressure exchanger for sea water desalination equipment. In a reverse osmosis(RO) system for desalinating sea water, more than 70 percent of the supplied sea water, brines which were impassable through RO membrane are bypassed, resulting in high energy losses. In this paper, a hydrostatic pressure exchanger consisting of an embedded water hydraulic piston motor and a water hydraulic piston pump was proposed and investigated in order to recover the energy of the bypassed brines. The pressurized brines are supplied to the embedded water hydraulic piston motor as power sources and the water hydraulic piston pump is driven by the output torque of the embedded water hydraulic piston motor as well as electric motor. Consequently, the energy of the bypassed brines can be recovered. To examine the electric energy saving characteristics of the hydrostatic pressure exchanger, a simulation model was constructed using commercial software and experiments were conducted. Through the results of simulation and experiment, the feasibility of the electric energy saving effect of the proposed hydrostatic pressure exchanger was investigated.

  • PDF

온도와 압력 변화가 압력지연삼투 공정 성능에 미치는 영향 (Effect of the Temperature and Pressure on Pressure Retarded Osmosis Performance)

  • 심진우;남숙현;구재욱;김은주;윤영한;황태문
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.321-325
    • /
    • 2016
  • The Pressure Retarded Osmosis (PRO) is the next generation desalination technique and is considered as a eco-friendly energy. This was conducted to evaluate the effect of the temperature and pressure on the PRO performance. The flux of the permeation was measured under different operating conditions and estimated the power density. An improvement of PRO performance is depend on increasing solution temperature and optimum pressure. The effect of increasing feed solution temperature has stronger impact on the PRO performance comparing to the draw solution temperature. The reason of the results was due to the change of osmotic power, viscosity, water permeability and structure parameter(s).

해수담수화 공정에서 역삼투막의 유기 막오염에 대한 SWRO 막의 화학세정 효율 평가 (Evaluation on Chemical Cleaning Efficiency of Organic-fouled SWRO Membrane in Seawater Desalination Process)

  • 박준영;홍성호;김지훈;정우원;남종우;김영훈;전민정;김형수
    • 상하수도학회지
    • /
    • 제25권2호
    • /
    • pp.177-184
    • /
    • 2011
  • Membrane fouling is an unavoidable phenomenon in operation of seawater reverse osmosis (SWRO) and major obstacle for economic and efficient operation. When fouling occurs on the membrane surface, the permeate flux is decreased, on the contrary, the trans-membrane pressure (TMP) is increased, therefore operation and maintaining costs and potential damage of membranes are able to the pivotal risks of the process. Chemical cleaning process is essential to prevent interruptions for effective RO membrane filtration process. This study focused on proper chemical cleaning condition for polyamide RO membranes of 4 companies. Several chemical agents were applied for chemical cleaning under numbers of operating conditions. Additionally, a monitoring tool of FEEM as autopsy analysis method is adapted for the prediction of organic bio-fouling.