• Title/Summary/Keyword: depth dose

Search Result 505, Processing Time 0.03 seconds

Commissioning Experience of Tri-Cobalt-60 MRI-guided Radiation Therapy System (자기공명영상유도 Co-60 기반 방사선치료기기의 커미셔닝 경험)

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2015
  • The aim of this study is to present commissioning results of the ViewRay system. We verified safety functions of the ViewRay system. For imaging system, we acquired signal to noise ratio (SNR) and image uniformity. In addition, we checked spatial integrity of the image. Couch movement accuracy and coincidence of isocenters (radiation therapy system, imaging system and virtual isocneter) was verified. Accuracy of MLC positioing was checked. We performed reference dosimetry according to American Association of Physicists in Medicine (AAPM) Task Group 51 (TG-51) in water phantom for head 1 and 3. The deviations between measurements and calculation of percent depth dose (PDD) and output factor were evaluated. Finally, we performed gamma evaluations with a total of 8 IMRT plans as an end-to-end (E2E) test of the system. Every safety system of ViewRay operated properly. The values of SNR and Uniformity met the tolerance level. Every point within 10 cm and 17.5 cm radii about the isocenter showed deviations less than 1 mm and 2 mm, respectively. The average couch movement errors in transverse (x), longitudinal (y) and vertical (z) directions were 0.2 mm, 0.1 mm and 0.2 mm, respectively. The deviations between radiation isocenter and virtual isocenter in x, y and z directions were 0 mm, 0 mm and 0.3 mm, respectively. Those between virtual isocenter and imaging isocenter were 0.6 mm, 0.5 mm and 0.2 mm, respectively. The average MLC positioning errors were less than 0.6 mm. The deviations of output, PDDs between mesured vs. BJR supplement 25, PDDs between measured and calculated and output factors of each head were less than 0.5%, 1%, 1% and 2%, respectively. For E2E test, average gamma passing rate with 3%/3 mm criterion was $99.9%{\pm}0.1%$.

Comparative Analysis between Preoperative Radiotherapy and Postoperative Radiotherapy in Clinical Stage I and II Endometrial Carcinoma (자궁내막암 환자에서 수술 전 방사선치료와 수술 후 방사선치료의 성적 비교 분석)

  • Keum Ki Chang;Lee Chang Geol;Chung Eun Ji;Lee Sang Wook;Kim Woo Cheol;Chang Sei Kyung;Oh Young Taek;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.377-383
    • /
    • 1995
  • Purpose : To obtain the optimal treatement method in patients with endometrial carcinoma(clinical stage FIGO I, II) by comparative analysis between preoperative radiotherapy (pre-op RT) and postoperative radiotherapy (post-op RT). Material and Methods : A retrospective review of 62 endometrial carcinoma patients referred to the Yonsei Cancer Center for radiotherapy between 1985 and 1991 was undertaken. Of 62 patients, 19 patients(Stagel : 12 patients. Stagell;7 patients) received pre-op RT before TAH(Total Abdominal Hysterectomy) and BSO (Bilateral Salphingoophorectomy) (Group 1) and 43 patients(Stage 1;32 patients, Stage 2; 11 patients) received post-op RT after TAH and BSO (Group 2). Pre-op irradiation was given 4-6 weeks prior to surgery and post-op RT administered on 4-5 weeks following surgery. All patients except 1 patient(Group 2: ICR alone) received external irradiation. Seventy percent(13/19) of pre-op RT group and 54 percent(23/42) of post-op RT group received external pelvic irradiation and intracavitary radiation therapy(ICR). External radiation dose was 39.6-55 Gy(median 45 Gy) in 5-6. 5weeks through opposed AP/PA fields or 4-field box technique treating daily, five days per week, 180 cGy per fraction. ICR doses were prescribed to point A(20-39.6 Gy, median 39 Gy) in Group 1 and 0.5cm depth from vaginal surface (18-30 Gy,median 21 Gy) in Group 2. Results : The overall 5 year survival rate was $95{\%}$. No survival difference between pre-op and post-op RT group.($89.3{\%}$ vs $97.7{\%}$, p>0.1) There was no survival difference by stage, grade and histology between two groups. The survival rate was not affected by presence of residual tumor of surgical specimen after pre-op RT in Group 1 (p>0.1), but affected by presence of lymph node metastasis in post-op RT group(P<0.5). The complication rate of pre-op RT group was higher than post-op RT. ($16{\%}$ vs $5{\%}$) Conclusion : Post-op radiotherapy offers the advantages of accurate surgical-pathological staging and low complication rate.

  • PDF

Analysis of Relative Output Factors for Cyberknife: Comparison of Son Chambers, Diode Detector and Films (사이버나이프 출력인자 분석: 전리함, 다이오드 검출기 및 필름)

  • Jang Ji-Sun;Shin Dong-Oh;Choi Byung-Ock;Lee Tae-Kyu;Choi Ihl-Bohng;Kim Moon-Chan;Kwon Soo-Il;Kang Young-Nam
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • The accuracy of the dosimetry in the Cyberknife system is accomplishing important role from all processes of the stereotactic radiosurgery. In this study, we estimated relative output factors for Cyberknife. All measurements were peformed by six different detectors: diode detector, X-Omat V film, Gafchromic EBT film, 0.015 cc, 0.125 cc and 0.6 cc ionization chamber The diode detector and three ionization chambers peformed using water phantom at 80 cm SSD and 1.5 cm depth. When the film measurements were peformed, the water phantom was replaced with a solidwater phantom. Each collimator normalized with respect to the output factor of the largest collimator (60 mm). For the collimators over than 30 mm, the output factors from the different detectors showed a good agreement within 0.5% except 0.6 cc ion chamber For the collimators less than 15 mm, there were substantial differences In the output factors among different detectors. That is, the value of output factor for the 5 mm collimator of a diode and Gafchromic film was each $0.656{\pm}0.009$ and $0.777{\pm}0.013$. In the ion chamber and diode detector, those difference were due to the presence of large dose gradients and lack of electronic equilibrium in narrow megavoltage x-ray beams Therefore, the Gafchromic EBT film were considered more accurate than the others detectors.

  • PDF

The Effect of Doxapram on Cardiopulmonary Function in Dogs under Total Intravenous Anesthesia with Remifentanil and Propofol (개에서 Remifentanil과 Propofol에 의한 완전 정맥 내 마취 시 Doxapram 투여가 심폐기능에 미치는 효과)

  • Yun, Sungho;Kwon, Youngsam
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.491-498
    • /
    • 2015
  • We investigated the effect of constant rate infusion (CRI) with doxapram on cardiopulmonary function during total intravenous anesthesia (TIVA) with remifentanil and propofol CRI in dogs. Fifteen male Beagle dogs were randomly divided into 3 groups. All groups were premedicated with medetomidine ($20{\mu}g/kg$, IV) and anesthetized by remifentanil/propofol CRI for one and half hour. At the initiating of the anesthesia, different doses of doxapram for each group were administrated as the followings; D1 group - doxapram 0.25 mg/kg bolus followed by doxapram $8.33{\mu}g/kg/min$, D2 group - doxapram 2 mg/kg bolus followed by doxapram $66.66{\mu}g/kg/min$, control group - normal saline. The anesthetic depth for surgery was well maintained in all groups throughout the anesthetic periods. The respiratory rate was significantly higher in D2 group than that of control group (p < 0.05). The values of $PaO_2$ and $SaO_2$ were significantly increased in both D1 and D2 groups compared with control group (p < 0.05). High dose of doxapram (D2 group) significantly decreased the level of $PaCO_2$ compared with control group (p < 0.05). The values of systolic, mean and diastolic arterial pressure were significantly increased in doxapram 2 group (p < 0.05). There were no significant differences in the values of heart rate and pH of arterial blood. Therefore, doxapram CRI may be useful to alleviate the suppression of cardiopulmonary function including hypoxia and hypotension during TIVA with remifentanil and propofol in dogs.

Taxonomical Classification and Genesis of Jeju Series in Jeju Island (제주도 토양인 제주통의 분류 및 생성)

  • Song, Kwan-Cheol;Hyun, Byung-Geun;Moon, Kyung-Hwan;Jeon, Seung-Jong;Lim, Han-Cheol;Lee, Shin-Chan
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.2
    • /
    • pp.230-236
    • /
    • 2010
  • Jeju Island is a volanic island which is located about 96 km south of Korean Peninsula. Volcanic ejecta, and volcaniclastic materials are widespread as soil parent materials throughout the island. Soils on the island have the characteristics of typical volcanic ash soils. This study was conducted to reclassify Jeju series based on the second edition of Soil Taxonomy and to discuss the formation of Jeju series in Jeju Island. Morphological properties of typifying pedon of Jeju series were investigated, and physico-chemical properties were analyzed according to Soil survey laboratory methods manual. The typifying pedon has dark brown (10YR 3/3) silt clay loam A horizon (0~22 cm), strong brown (7.5YR 4/6) silty clay BAt horizon (22~43 cm), brown (7.5YR 4/4) silty clay Bt1 horizon (43~80 cm), brown (7.5YR 4/6) silty clay loamBt2 horizon (80~105 cm), and brown (10YR 5/4) silty clay loam Bt3 horizon (105~150 cm). It is developed in elevated lava plain, and are derived from basalt, and pyroclastic materials. The typifying pedon contains 1.3~2.1% oxalate extractable (Al + 1/2 Fe), less than 85%phosphate retention, and higher bulk density than 0.90 Mg $m^{-3}$. That can not be classified as Andisol. But it has an argillic horizon from a depth of 22 to 150 cm, and a base saturation (sum of cations) of less than 35% at 125 cm below the upper boundary of the argillic horizon. That can be classified as Ultisol, not as Andisol. Its has 0.9% or more organic carbon in the upper 15 cm of the argillic horizon, and can be classified as Humult. It dose not have fragipan, kandic horizon, sombric horizon, plinthite, etc. in the given depths, and key out as Haplohumult. A hoizon (0~22 cm) has a fine-earth fraction with both a bulk density of 1.0 Mg $cm^{-3}$ or less, and Al plus 1/2 Fe percentages (by ammonium oxalate) totaling more than 1.0. Thus, it keys out as Andic Haplohumult. It has 35% or more clay at the particle-size control section, and has thermic soil temperature regime. Jeju series can be classified as fine, mixed, themic family of Andic Haplohumults, not as ashy, thermic family of Typic Hapludands. In the western, and northern coastal areas which have a relatively dry climate in Jeju Island, non Andisols are widely distributed. Mean annual precipitation increase 110 mm, and mean annual temperature decrease $0.8^{\circ}C$ with increasing elevation of 100m. In the western, and northern mid-mountaineous areas Andisols, and non Andisols are distributed simultaneously. Jeju series distributed mainly in the western and northern mid-mountaineous areas are developed as Ultisols with Andic subgroup.