• Title/Summary/Keyword: depth dose

Search Result 509, Processing Time 0.029 seconds

Anesthetic Effects of the Xylazine-Tiletamine/Zolazepam(Zoletil$\circledR$) Combination in Dogs (Xylazine과 Tiletamine/Zolazepam(Zoletil$\circledR$)의 투여 농도 변화가 개의 마취에 미치는 영향)

  • 김준일;장환수;장광호
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.168-171
    • /
    • 2004
  • The effects of alterations of dose of xylaznie (X) and Zoltil$\circledR$ (TZ) on canine anesthesia were examined. Experimental groups were divided into three (Group 1: X 1.1 mg/kg and TZ 10 mg/kg, Group 2: X 1.65 mg/kg and TZ 7.5 mg/kg, Group 3: X 2.2 mg/kg and TZ 5 mg/kg), and each had 5 dogs. A femoral artery was catheterized for measurement of blood pressure, and baseline value was measured. The dogs were sedated with xylazine intramuscularly, then after 10 minutes TZ were injected intravenously. Mean arterial blood pressures (MAP), duration of analgesia, mean arousal time (MAT) and mean walking time (MWT) after TZ injection were measured, and the depth of analgesia and the quality of recovery were scored. The values of MAP were recorded from the time of pre-xylazine injection to arousal. Duration of analgesia and was assessed by tail clamping test, and which were done at 10 minutes intervals after TZ injection. The decreases of MAP from 40 minutes after TZ injection were significant (p<0.05). In group 2, MAP at 20 minutes, and from 40 minutes to arousal were significantly decreased (p<0.05). In group 3, MAP were significantly decreased from 40 minutes. MAT were 62.2$\pm$9.2 minutes in group 1, 60.2$\pm$7.5 minutes in group 2, and 71.0$\pm$6.9 minutes in group 3. MAT in group 3 was significantly increased compared with group 2 (p<0.05), and the differences of MWT among each groups were not significant (p>0.05). The scores of quality of recovery were significantly lowered in group 3 compared with group 1 or group 2, which means the side effects of recovery were less occurred. Thus, it was considered that the combination X 2.2 mg/kg IM and TZ 5 mg/kg IV is more effective to surgical procedures and to prevent long and rough recovery of Zoletil anesthesia.

The Feasibility Study on the Direct Use of the MC-derived Physical Quantities to Determine the Model Parameters of RTPS with -Model-Based Photon Dose Calculation Algorithm (모델기반 광자선량 계산방식을 사용하는 전산화치료계획장치의 모델변수 결정에 있어 몬테카를로 모사법에 의해 유도된 방사선 물리량의 직접 적용 가능성에 대한 연구)

  • 강세권;박희철;배훈식;조병철
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.77-83
    • /
    • 2004
  • The commissioning of a model-based treatment planning system requires many parameters to fit the measured depth doses and transverse profiles. For the commissioning of the Pinnacle$^3$ system, through the Monte Carlo (MC) simulation, the necessary parameters, including the photon spectrum, contaminant electrons, off-axis softening and fluency of photons, were observed. Through the simulation the parameters contained valuable information, but the calculated results of the Pinnacle$^3$ using the MC-derived parameters showed discrepancies with those measured for the off-axis softening and the fluency of photons. Even though the MC calculation produces reasonable values for the commissioning, the thorough physical basis of the Pinnacle$^3$'s commissioning process is needed in order to directly use the MC derived parameters.

  • PDF

3D Lithography using X-ray Exposure Devices Integrated with Electrostatic and Electrothermal Actuators

  • Lee, Kwang-Cheol;Lee, Seung S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.4
    • /
    • pp.259-267
    • /
    • 2002
  • We present a novel 3D fabrication method with single X-ray process utilizing an X-ray mask in which a micro-actuator is integrated. An X-ray absorber is electroplated on the shuttle mass driven by the integrated micro-actuator during deep X-ray exposures. 3D microstructures are revealed by development kinetics and modulated in-depth dose distribution in resist, usually PMMA. Fabrication of X-ray masks with integrated electrothermal xy-stage and electrostatic actuator is presented along with discussions on PMMA development characteristics. Both devices use $20-\mu\textrm{m}$-thick overhanging single crystal Si as a structural material and fabricated using deep reactive ion etching of silicon-on-insulator wafer, phosphorous diffusion, gold electroplating, and bulk micromachining process. In electrostatic devices, $10-\mu\textrm{m}-thick$ gold absorber on $1mm{\times}1mm$ Si shuttle mass is supported by $10-\mu\textrm{m}-wide$, 1-mm-long suspension beams and oscillated by comb electrodes during X-ray exposures. In electrothermal devices, gold absorber on 1.42 mm diameter shuttle mass is oscillated in x and y directions sequentially by thermal expansion caused by joule heating of the corresponding bent beam actuators. The fundamental frequency and amplitude of the electrostatic devices are around 3.6 kHz and $20\mu\textrm{m}$, respectively, for a dc bias of 100 V and an ac bias of 20 VP-P (peak-peak). Displacements in x and y directions of the electrothermal devices are both around $20{\;}\mu\textrm{m}$at 742 mW input power. S-shaped and conical shaped PMMA microstructures are demonstrated through X-ray experiments with the fabricated devices.

Effcets of Initial Oxygen Concentration on Oxygen Pileup and the Diffusion of Impurities after High-energy Ion Impaltation (초기 산소 농도가 고에너지 이온 주입시 발생하는 산소 축적 및 불순물 확산에 미치는 영향)

  • 고봉균;곽계달
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.4
    • /
    • pp.48-56
    • /
    • 1999
  • In this paper, we have investigated experimentally the effects of initial oxygen concentration on oxygen pileup phenomenon and the diffusion of implanted impurities. 1.2 MeV $^{11}B^{+}$ and 2.2 MeV $^{31}P^{+}$ ions were implanted into p-type (100) Si wafers with a dose of 1${\times}10^{15}$ / $\textrm{cm}^2$. Secondary ion mass spectrometry(SIMS) measurements were carried out to obtain depth distribution profiles for implanted impurities and oxygen atoms after two-step annealing of $700^{\circ}C$(20 hours)+$1000^{\circ}C$(10 hours). Residual secondary defect distribution and annealing behabiour were also studied by cross-sectional transmission electron microscopy(TEM) observations. Oxygen pileup nearly $R_p$(projected range) were observed by SIMS measurements and considerable amount of residual secondary defect layer were observed by TEM observations. It can be seen that oxygen atoms are trapped at the secondary defects by the experimental results. Enhanced diffusions of boron and phosphorus to the bulk direction were observed with the increasing of initial oxygen concentration.

  • PDF

ELECTRON MICROSCOPIC STUDY OF THE SPILT IRRADIATION EFFECTS ON THE RAT PAROTID DUCTAL CELLS (방사선 분할조사가 타액선 도관세포에 미치는 영향에 관한 전자현미경적 연구)

  • Kim Sang Soo;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.18 no.1
    • /
    • pp.177-187
    • /
    • 1988
  • This study was designed to investigate the effects of split irradiation on the salivary ductal cells, especially on the intercalated cells of the rat parotid glands. For this study, 24 Sprague-Dawley strain rats were irradiated on the head and neck region with two equal split doses of 9Gy for a 4 hours interval by Co-60 teletherapy unit, Picker's model 4M 60. The conditions of irradiation were that field size, dose rate, SSD and depth were 12×5㎝, 222 cGy/min, 50㎝ and 1㎝, respectively. The experimental animals were sacrificed 1. 2, 3, 6, 12, hours and 1, 3, 7, days after the irradiation and the changes of the irradiated intercalated cells of the parotid glands were examined under light and electron microscope. The results were as follows: 1. By the split irradiation, the degenerative changes of intercalated cells of the parotid glands appeared at 3 hours after irradiation and the most severe cellular degeneration observed at 6 hours after irradiation. The repair processes began from 12 hours after irradiation and have matured progressively. 2. Under electron microscope, loss of nuclear membrane, microvilli and secretory granules, derrangement of chromosomes, degeneration of cytoplasm, atrophy or reduction of intracytoplasmic organelles were observed in the intercalated ductal cells after split irradiation. 3. Under light microscope, derrangement of ductal cells, widening of cytoplasms and nuclei, hyperchromatism and proliferation of ductal cells were observed in intercalated ducts after split irradiation.

  • PDF

Research of Antioxidant Activity from Plant Resources using Proton Beam(I) (양성자 빔을 이용한 식물자원의 항산화 활성에 관한 연구(I))

  • Moon, Byung-Sik;Son, Gui-Youp;Choi, Jin-Kuk;Seo, Dong-Won;Lee, Kap-Duk
    • Journal of Life Science
    • /
    • v.17 no.8 s.88
    • /
    • pp.1100-1103
    • /
    • 2007
  • In proton therapy, the Bragg peak is spread out by modulating or degrading the energy of the particles to cover a well-defined target volume at a given depth. Proton transfer plays a key role in a variety of biological, the origin of the elements, tests of the standard model along with applications in medicine, industry and chemical phenomena such as water autoionization, fast proton diffusion, acid-base neutralization. We have studied the radiolysis of various natural resources and have evaluated the antioxidant activity of radiolysis products by proton beam. The most of antioxidant activities of natural resources were decreased with increasing proton fluence. Proton beam induced antioxidant activities both in 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) assay and 2,2'-azinobis(3-ethylbenzot hialozinesulfonic acid) cation radical $(ABTS^{.+})$ assay by a dose dependent fashion.

Magnetic Sector SIMS의 Sample Holder 위치에 따르는 RSF (Relative Sensitivity Factor) 변화 검증

  • 홍성윤;이종필;홍태은;윤명노;민경열;이순영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.192-192
    • /
    • 1999
  • SIMS(Secondary Ion Mass Spectrometry)는 다른 표면 분석장비와 비교하여^g , pp m,^g , pp b 단위의 미량분석이 가능한 장비로서, 특히 depth Profiling을 위한 dynamic SIMS는 Mass Spectrometer의 종류에 따라 Quadrupole SIMS (Q-SIMS)와, Magnetic Sector SIMS (M-SIMS)로 분류된다. 한편, Q-SIMS와 달리 M-SIMS의 경우, Transmission을 높여 주기 위해 Sample Holder에 수 keV의 bias를 걸어 주는데, 이로 인하여 분석 원소에 대한 Sensitivity가 향상되어 지는 반면, RSF의 변화와 같은 분석상의 Artifact가 발생하게 된다. 일반적으로 Q-SIMS의 경우에는 RSF의 RSD(Relative Standard Deviation)가 1%이내에서 보고되고 있지만 M-SIMS에 있어서는 이러한 Deviation이 M-SIMS보다 크게 나타난다. 이 차이는 주로 Sample Holder와 Immersion Lens 사이에 형성되는 Magnetic Field의 왜곡과 Spectrometer의 문제로부터 발생한다. 본 논문에서는 Sample Holder의 종류 및 holder so window 위치에 따라 RSF의 차이를 측정하고 그 data를 RS/1 통계 Package를 이용하여 계량적으로 검증하였으며, 그 차이의 원인과 대책을 제시하고자 한다. 실험에 사용된 Sample은 Si(100) p-type Wafer에 Boron을 이온 주입하여 제작하였다. 이온 주입 장비는 Varian E-500HP이며, 5.0E13 ions/cm2의 dose양을 80keV의 Energy로 각각 7도와 22도의 Tilt와 Twist Angle로 이온 주입을 하였다. SIMS분석에 사용된 Sample Holder는 각각 3 Hole, 9 Hole Type HOlder이며, 분석은 Cameca IMS-6f를 사용하여 B에 대한 Matrix Peak으로 28Si++를 얻었다. 실험 결과 3 Hole Type Sample Holder의 경우 RSF의 RSD는 5.84%, 9Hle Type Sample Holder의 경우는 14.3%로 나타났으나 분석 Window의 위치에 따르는 Grouping을 실시한 결과, 3 Hole Type Sample Holder의 경우 1.2%, 9Hole Type Sample Holder의 경우 9.8%로 RSF의 변화가 감소하였다. 이러한 Deviation은 Sample Holder를 Mount시킬 때 세 개의 Screw를 이용하여 Immersion Lens와의 평형을 잡아주기 때문에 발생하며, 이 Munting을 정확히 해줌으로써 RSF의 변화를 줄일 수 있으나, 실제로 완벽한 Mounting이 불가능하기 때문에 RSF를 일정하게 하기 위해서는 Sample Holder so Window의 취치를 일정하게 설정한 후 분석을 실시해야 한다고 판단된다.

  • PDF

Effect of chloroform extract of traditional Dicranopteris linearis leaves against paracetamol- and CCl4-induced liver toxicity in rats

  • Din, Syafawati Shamsahal;Mamat, Siti Syariah;Ismail, Noor Aisyah;Zainulddin, Wan Noraziemah Wan;Zabidi, Zalina;Yahya, Farhana;Kamisan, Farah Hidayah;Mohtarrudin, Norhafizah;Othman, Fezah;Suhaili, Zarizal;Zakaria, Zainul Amiruddin
    • CELLMED
    • /
    • v.2 no.4
    • /
    • pp.34.1-34.5
    • /
    • 2012
  • The present study aimed to determine the hepatoprotective activity of the chloroform extract of D. linearis leaves (CEDL) using the paracetamol (PCM)- and carbon tetrachloride ($CCl_4$)-induced liver injury models in rats. The rats received $dH_2O$ (negative control), 200 mg/kg of silymarin (positive control) or CEDL (50, 250 and 500 mg/kg) orally once daily for 7 days and then were subjected to the hepatotoxic induction on the $7^{th}$ day. The samples (i.e. blood and liver) were collected and underwent biochemical and microscopical analysis, respectively. From the data obtained, both inducers caused significant (p < 0.05) increase in the levels of AST and ALT when compared to the control group, which were significantly (p < 0.05) reduced by CEDL in a generally dose-dependent manner. These biochemical findings were supported by the histopathological analysis and histological scoring. In conclusion, CEDL possesses potential hepatoprotective activity, which could be associated with its flavonoid and tannin contents with the mechanisms of hepatoprotection linked to either its antioxidant or anti-inflammtory/immunomodulating activities. Further in-depth studies are required to identify the responsible bioactive compound.

Effects of Local Anesthetics on Rotational Mobility of n-(9-Anthroyloxy)stearic Acid in Neuronal Membranes

  • Jang, Hye-Ock;Lee, Chang;Choi, Min-Gak;Shin, Sang-Hun;Chung, In-Kyo;Yun, Il
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.3
    • /
    • pp.119-124
    • /
    • 2003
  • To elucidate the molecular mechanism of pharmacological action of local anesthetics, we studied membrane actions of tetracaine, bupivacaine, lidocaine, prilocaine and procaine. Fluorescence polarization of n-(9-anthroyloxy)stearic acid (n-AS) was used to examine the effects of these local anesthetics on differential rotational mobility of different positions of the number of synaptosomal plasma membrane vesicle (SPMV) phospholipid carbon atoms. The four membrane components differed with respect to 3, 6, 9 and 16-(9-anthroyloxy)stearic acid (3-AS, 6-AS, 9-AS and 16-AP) probes, indicating that differences in the membrane fluidity might be present. Degrees of the rotational mobility of 3-AS, 6-AS, 9-AS and 16-AP were different depending on depth of hydrocarbon interior. In a dose-dependentmanner, tetracaine, bupivacaine, lidocaine, prilocaine and procaine decreased anisotropy of 3-AS, 6-AS, 9-AS and 16-AP in the hydrocarbon interior of the SPMV. These results indicate that local anesthetics have significant disordering effects on hydrocarbon interior of the SPMV, thus affecting the transport of $Na^+$ and $K^+$ in nerve membranes and leading to anesthetic action.

SIMS Depth Profiling Analysis of Cl in $TiCl_4$ Based TiN Film by Using $ClCs_2^+$ Cluster Ions

  • Gong, Su-Jin;Park, Sang-Won;Kim, Jong-Hun;Go, Jung-Gyu;Park, Yun-Baek;Kim, Ho-Jeong;Kim, Chang-Yeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.161-161
    • /
    • 2012
  • 질화티타늄(Titanium Nitride, TiN)은 화학적 안정성이 우수하고, N/Ti 원소 비율에 따라 열전도성 및 전기전도성이 변화하는 특성을 가지고 있어서 Metal Insulator Silicon (MIS) 나 Metal Insulator Metal (MIM) capacitor의 metal electrode 물질로 적용되고 있다. $TiCl_4$$NH_3$ gas를 이용하여 $500^{\circ}C$ 이상의 고온 조건에서 Chemical Vapor Deposition (CVD) 법으로 TiN 박막을 증착하는 방식이 가장 널리 사용되고 있으나, TiN 박막 내의 Chlorine (Cl) 원소가 SiO2 두께와 누설전류 밀도를 증가시키는 요인으로 작용하므로 Cl의 거동 및 함량 제어를 통한 전기적인 특성의 향상 평가가 요구되고 있다[1-3]. 본 실험에서는 $SiO_2$ 위에 TiN을 적층 한 구조에서 magnetic sector type의 Secondary Ion Mass Spectrometry (SIMS)를 이용하여 Cl 원소의 검출도 개선 방법을 연구하였다. 일반적인 $Cs^+$ 이온을 이용하여 $Cl^-$ 이온을 검출할 경우에는 TiN 하부에 $SiO_2$가 존재함에 따른 charging effect와 mass interference가 발생되는 문제점이 관찰되었다. 이를 개선하기 위해 Cl과 Cs 원소가 결합된 $ClCs^+$ cluster ion을 검출하는 방법을 시도하였으나, Cl- 이온 검출 방식에 비해 오히려 낮은 검출도를 나타내었으나 Cl 원소가 속하는 halogen 족 원소의 높은 전자 친화도 특성을 이용한 $ClCs_2^+$ cluster ion을 검출하는 방법[4]을 적용한 경우에는 $ClCs^+$ 방식에 비해 검출도가 3order 개선되는 결과를 확보하였으며, 이 결과를 토대로 Cl dose ($atoms/cm^2$) 와 Rs (ohm/sq) 간의 상관 관계에 대해 고찰하고자 한다.

  • PDF