• Title/Summary/Keyword: dentistry radiation

Search Result 301, Processing Time 0.023 seconds

A Study of Temperature Changes in the Dental Tissues Irradiated by $10.6{\mu}m$ Laser Beam ($CO_2$ 레이저 광의 조사조건에 따른 치아의 치수강내 온도상승에 관한 연구)

  • Ko, D. S.;Bak, Y. H.;Shin, S. H.;Eom, H. S.;Kim, U.;Lee, C. Y.
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.210-216
    • /
    • 1990
  • This study was performed to obtain fundamental data on temperature increases in the dental tissues irradiated by IO.opm laser radiation. For this purpose a experimental facility was established. which was composed of a CO2 laser. a shutter unit and a temperature sensing device. The temperature changes in the pulp chamber of extracted molars. during and after the laser irradiation. were measured as function of laser power. the time of irradration and the thickness of the sample. An empirical formula for the maximum temperature increases, $\DeltaT_m$ was derived from the measured data as follows; $\DeltaT_m=\alphaP\Delta\tauexp(-\betad)$$ where P. $\Delta\tau$ and d are the laser power(W). irradiation time{sec) and the thickness(mm) between pulp chamber and occlusal surface. respectively. Also a theoretical calculation model based on simplified assumptions were established and the results from the calculation were compared with the measured temperature data. A fairly good agreement was obtained.obtained.

  • PDF

Orthodontic appliances and MR image artefacts: An exploratory in vitro and in vivo study using 1.5-T and 3-T scanners

  • Sonesson, Mikael;Al-Qabandi, Fahad;Mansson, Sven;Abdulraheem, Salem;Bondemark, Lars;Hellen-Halme, Kristina
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.63-71
    • /
    • 2021
  • Purpose: The aim of this study was to assess the artefacts of 12 fixed orthodontic appliances in magnetic resonance images obtained using 1.5-T and 3-T scanners, and to evaluate different imaging sequences designed to suppress metal artefacts. Materials and Methods: In vitro, study casts of 1 adult with normal occlusion were used. Twelve orthodontic appliances were attached to the study casts and scanned. Turbo spin echo (TSE), TSE with high readout bandwidth, and TSE with view angle tilting and slice encoding for metal artefact correction were used to suppress metal artefacts. Artefacts were measured. In vivo, 6 appliances were scanned: 1) conventional stainless-steel brackets; 2) nickelfree brackets; 3) titanium brackets; 4) a Herbst appliance; 5) a fixed retainer; and 6) a rapid maxillary expander. The maxilla, mandible, nasopharynx, tongue, temporomandibular joints, and cranial base/eye globes were assessed. Scores of 0, 1, 2, and 3 indicated no artefacts and minor, moderate, and major artefacts, respectively. Results: In vitro, titanium brackets and the fixed retainer created minor artefacts. In vivo, titanium brackets caused minor artefacts. Conventional stainless-steel and nickel free brackets, the fixed retainer, and the rapid maxillary expander caused major artefacts in the maxilla and mandible. Conventional stainless-steel and nickel-free brackets caused major artefacts in the eye globe (3-T). TSE with high readout bandwidth reduced image artefacts in both scanners. Conclusion: Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures(1.5-T and 3-T) when using TSE with high readout bandwidth.

Can ultra-low-dose computed tomography reliably diagnose and classify maxillofacial fractures in the clinical routine?

  • Gerlig Widmann;Marcel Dangl;Elisa Lutz;Bernhard Fleckenstein;Vincent Offermanns;Eva-Maria Gassner;Wolfgang Puelacher;Lukas Salbrechter
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.69-75
    • /
    • 2023
  • Purpose: Maxillofacial trauma predominantly affects young adults between 20 and 40 years of age. Although radioprotection is a legal requirement, the significant potential of dose reduction in computed tomography (CT) is still underused in the clinical routine. The objective of this study was to evaluate whether maxillofacial fractures can be reliably detected and classified using ultra-low-dose CT. Materials and Methods: CT images of 123 clinical cases with maxillofacial fractures were classified by two readers using the AOCOIAC software and compared with the corresponding results from post-treatment images. In group 1, consisting of 97 patients with isolated facial trauma, pre-treatment CT images at different dose levels (volumetric computed tomography dose index: ultra-low dose, 2.6 mGy; low dose, <10 mGy; and regular dose, <20 mGy) were compared with post-treatment cone-beam computed tomography (CBCT). In group 2, consisting of 31 patients with complex midface fractures, pre-treatment shock room CT images were compared with post-treatment CT at different dose levels or CBCT. All images were presented in random order and classified by 2 readers blinded to the clinical results. All cases with an unequal classification were re-evaluated. Results: In both groups, ultra-low-dose CT had no clinically relevant effect on fracture classification. Fourteen cases in group 2 showed minor differences in the classification code, which were no longer obvious after comparing the images directly to each other. Conclusion: Ultra-low-dose CT images allowed the correct diagnosis and classification of maxillofacial fractures. These results might lead to a substantial reconsideration of current reference dose levels.

Occupational Exposure to Physical and Chemical Risk Factors: A Systematic Review of Reproductive Pathophysiological Effects in Women and Men

  • Soleiman Ramezanifar;Sona Beyrami;Younes Mehrifar;Ehsan Ramezanifar;Zahra Soltanpour;Mahshid Namdari;Noradin Gharari
    • Safety and Health at Work
    • /
    • v.14 no.1
    • /
    • pp.17-30
    • /
    • 2023
  • The human reproductive system can be affected by occupational exposure to many physical and chemical risk factors. This study was carried out to review the studies conducted on the issue of the pathophysiological effects of occupational physical and chemical risk factors on the reproductive system of females and males. In this systematic review, the databases such as "Google Scholar," "Pub-Med," "Scopus," and "Web of Science" were used. Following the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA 2020), the studies included in our study were published between 2000 and 2021. In order to extract the required data, all sections of the articles were reviewed. Out of 57 articles we reviewed, 34 articles were related to field studies and 23 articles to clinical studies. Among them, 43 studies dealt with the pathophysiological effects of chemical agents, six studies dealt with the pathophysiological effects of physical factors, and 8 studies dealt with the pathophysiological effects of physicochemical factors on the human reproductive system. Physical (noise, heat, and radiofrequency radiation) and chemical (such as carbamate and organophosphate pesticides, benzene, toluene, xylene, formaldehyde, NO2, CS2, manganese, lead, nickel, and n-hexane) risk factors had pathophysiological effects on the human reproductive system. The presence of these risk factors in the workplace caused damage to the human reproductive system. The rate of these negative pathophysiological effects can be reduced by performing appropriate managerial, technical, and engineering measures in work environments.

Radioprotective Effect of Red Ginseng in Irradiated Mice with ${\gamma}$-ray (생쥐에서 홍삼의 감마선조사에 의한 방어효과)

  • Seung, Ka-Yeon;Lee, Heung-Man;Kim, Jong-Sang;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.31-35
    • /
    • 2010
  • Recently, the incidents of direct or indirect radiation exposure due to increase of use of radiation or radioisotope are on the increase in medical and industrial circles. If cells are irradiated, free radicals are created through biological process, and cells are directly or indirectly damaged. This research intends to explore into the effect of saponin at the level of cell (in vitro) and entity (in vivo), using red ginseng extract "saponin", as radioprotective agent. In the experiment implemented at the level of cell (in vitro), degree of cell activity was measures by adding mouse mesenchymal stem cells "C3H/10T1/2 cells" into red ginseng extract "saponin(0, 0.05, 0.2, and 0.4 g/L)", and then the optimal concentration of saponin influencing cells was calculated, in 24, 48, 72, and 96 hours after gamma irradiation at the optimal concentration of saponin, each cell survival rate was observed through XTT assay. The best time period of cultivation for the optimal activity of C3H/10T1/2 cells was as 48 hours, and the degree of optimal activity was shown at 0.05 g/L. In 48 hours after irradiation of 5 Gy to C3H/10T1/2 cells at 0.05 g/L, the degree of activity of cells increased by 10%. In the experiment implemented at the level of entity (in vivo), red ginseng extract "saponin" at a dose of 100 mg/kg/day was injected into the abdominal cavity of six-week immature mouse for two weeks. Right after the last abdominal injection, total body irradiation of gamma rays was carried out at a dose of 5 Gy and 10 Gy. And after irradiation, the blood sample was taken, and then the number of red corpuscles was counted. In result, the decrement of experimental group treated with red ginseng extract "saponin" was 2.3 times larger than that of control group. In view of the results so far achieved, it was revealed that red ginseng extract "saponin" has a radiation exposure protection effect in the experiment implemented at the level of cell (in vitro). In case of animal experiment, the decrement of number of red corpuscles decreased. Finally, it is necessary to carry out more various researches continuously.

A CLINICAL STUDY ON SUPERIORLY BASED PLATYSMA MYOCUTANEOUS CERVICAL FLAP FOR RECONSTRUCTION FOLLOWING INTRAORAL SOFT TISSUE CANCER SURGERY (구강내 연조직 암 절제후 상부기조 광경근 근피부 경부 피판을 이용한 구강내 재건에 관한 임상적 연구)

  • Park, Bong-Wook;Byun, June-Ho;Shin, Hee-Suk;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.83-91
    • /
    • 2008
  • The goal of reconstruction following ablative therapy for intraoral cancer is the restoration of form and function to permit a return to activities of daily life. Traditional reconstruction includes split thickness skin grafts, myocutaneous flaps and, more recently, various free flaps. Free flaps provide higher level of functional recovery relative to that seen with other techniques but require the complexity of the technique and microvascular anastomosis and thus, extended surgical time and occasionally a second team for harvesting. The platysma myocutaneous cervical flap is a possible alternative for intraoral reconstruction. It is thin and pliable like the tissue provided by the radial forearm free flap. It can be harvested with enough tissue to close most head and neck ablative defects. There is virtually no donor site morbidity involved. This study evaluated 7 patients affected by intraoral squamous cell carcinoma (SCC). All patients underwent the resection of intraoral SCC with neck dissection and subsequent intraoral reconstruction with the superiorly based platysma myocutaneous cervical flap. Flap-related complications occurred in 3 patients. Adjuvant radiation therapy was performed in 3 patients. Average follow-up was 24.1 months after surgery, with a range of 8 to 42 months. All patients presented self assessment of discomfort associated with intraoral recipient sites and cervical donor sites. However, the neck function measured by two-inclinometer technique was within the normal range during relatively long term follow-up period. Our study concluded that superiorly based platysma myocutaneous cervical flap is good alternative to free flaps, especially for relatively smaller defects and for the defects appropriate for the rotation arc of the flap.

The phenomenological study of self-management intervention among breast cancer survivors: Non-pharmacological approaches (유방암 생존자들의 자가관리에 대한 현상학적 연구: 비약물적 접근방법을 중심으로)

  • Heo, Seok-Mo;Heo, Narae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.270-284
    • /
    • 2016
  • The purpose of this study was to understand the essential structure and meaning of self-management intervention for breast cancer survivors by using non-pharmacological approaches. The study participants were 10 breast cancer survivors who were completing cancer treatment that involved surgery, chemotherapy, and radiation therapy. Data collected between August 2014 and February 2015 at E Hospital in S city were analyzed by using Colaizzi's phenomenological method. Outcomes were classified into seven essential themes: 1) application of comfort measures to alleviate ongoing symptoms, 2) movement to change physical conditions, 3) special herbal intake to prevent recurrence, 4) a specially designed diet plan for health self-management, 5) constant awareness of complementary and alternative medicine, 6) unmet needs treated by one's own doctor's prescription, and 7) future life toward a nature-friendly environment. The study results contribute to a deeper understanding of self-management interventions in the daily lives of Korean breast cancer survivors. In addition, results provide an essential resource, based on actual self-management styles, that will help survivors to obtain guidance and participate in appropriate programs.

Studies of Automatic Dental Cavity Detection System as an Auxiliary Tool for Diagnosis of Dental Caries in Digital X-ray Image (디지털 X-선 영상을 통한 치아우식증 진단 보조 시스템으로써 치아 와동 자동 검출 프로그램 연구)

  • Huh, Jangyong;Nam, Haewon;Kim, Juhae;Park, Jiman;Shin, Sukyoung;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • The automated dental cavity detection program for a new concept intra-oral dental x-ray imaging device, an auxiliary diagnosis system, which is able to assist a dentist to identify dental caries in an early stage and to make an accurate diagnosis, was to be developed. The primary theory of the automatic dental cavity detection program is divided into two algorithms; one is an image segmentation skill to discriminate between a dental cavity and a normal tooth and the other is a computational method to analyze feature of an tooth image and take an advantage of it for detection of dental cavities. In the present study, it is, first, evaluated how accurately the DRLSE (Direct Regularized Level Set Evolution) method extracts demarcation surrounding the dental cavity. In order to evaluate the ability of the developed algorithm to automatically detect dental cavities, 7 tooth phantoms from incisor to molar were fabricated which contained a various form of cavities. Then, dental cavities in the tooth phantom images were analyzed with the developed algorithm. Except for two cavities whose contours were identified partially, the contours of 12 cavities were correctly discriminated by the automated dental caries detection program, which, consequently, proved the practical feasibility of the automatic dental lesion detection algorithm. However, an efficient and enhanced algorithm is required for its application to the actual dental diagnosis since shapes or conditions of the dental caries are different between individuals and complicated. In the future, the automatic dental cavity detection system will be improved adding pattern recognition or machine learning based algorithm which can deal with information of tooth status.

RELIABILITY OF SPIRAL TOMOGRAPHY FOR IMPLANT SITE MEASUREMENT OF THE MANDIBLE (하악골 매식 부위 계측을 위한 나선형 단층촬영술의 신뢰도)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.27-47
    • /
    • 1997
  • The purpose of this study was to evaluate the accuracy and usefulness of spiral tomography through the comparison and analysis of SCANORA cross-sectional tomographs and DentaScan computed tomographic images of dry mandibles taken by a SCANORA spiral tomographic machine and a computed tomographic machine. Thirty-one dry mandibles with full or partial edentulous areas were used. To evaluate the possible effect of location in the edentulous area, it was divided into 4 regions of Me (region of mental foramen), MI (the midportion between Me and M2), M2 (the midportion between mental foramen and mandibular foramen) and S (the midportion of the mandibular symphysis). A ZPC column (sized 4 mm x 5 mm) was seated on the edentulous regions of Me, MI, M2 and S using the acrylic stent. Then SCANORA spiral tomography and computed tomography were taken on the edentulous regions which contained the ZPC column. The ZPC columns and cross-sectional images of the mandible were measured in the radiographs by three observers and the differences between the two imaging modalities were analysed. The results were as follows: 1. In comparing the actual measurements of the ZPC column and measurements in the radiographs, the mean error of the DentaScan computed tomography was 0.07 mm in vertical direction and -0.06 mm in horiwntal direction, while the mean error of the SCANORA spiral tomography was 0.06 mm in vertical direction and -0.12 mm in horizontal direction. There was a significant difference between the two radiographic techniques in the horizontal measurement of the ZPC column of the symphysis region (p<0.05). But there was no significant difference in the measurements of other regions (p>0.05). 2. In measurements of the distance from the alveolar crest to the inferior border of the mandible (H), and of the distance from the alveolar crest to the superior border of the mandibular canal (Y), there was no significant difference between the two radiographic techniques (p>0.05). 3. In measurements of the distance from the lingual border of the mandible to the buccal border of the mandible (W), and of the distance from the lingual border of the mandible to the lingual border of the mandibular canal (X), there was a significant difference between the two radiographic techniques in measurements of the midportion between the mental foramen and the mandibular foramen (M2) (p<0.05). But there were no significant differences in measurements of the other regions of symphysis (S), mental foramen (Me), the first one-fourth portion between the mental foramen and the mandibular foramen (M1) (p>0.05). 4. Considering the mean range of measurements between observers, the measurements of SCANORA spiral tomography showed higher value than those of DentaScan computed tomography, except in measurements of symphysis (S). 5. On the detectability of the mandibular canal, there was no significant difference between the two radiographic techniques (p>0.05). In conclusion, SCANORA spiral tomography demonstrated a higher interobserver variance than that of DentaScan computed tomography for implant site measurements in the posterior edentulous area of the mandible. These differences were mainly the result of difficulty in the detection of the border of the mandible in SCANORA spiral tomography. But considering the cost and the radiation exposure, SCANORA spiral tomography can be said to be a relatively good radiographic technique for implant site measurement.

  • PDF

THE EFFECT OF LOW DIETARY CALCIUM AND IRRADIATION ON MANDIBLE IN RATS (저칼슘식이와 방사선조사가 백서 악골에 미치는 영향의 실험적 연구)

  • Lee Sun-Ki;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.229-250
    • /
    • 1993
  • This study was performed to investigate the morphological and structural changes of bone tissues and the effects of irradiation on the mandibular bodies of rats which were fed low calcium diets. In order to carry out this experiment, 160 seven-week old Sprague-Dawley strain rats weighing about 150 gm were selected and equally divided into one normal diet group of 80 rats and one low calcium diet group with the remainder. These groups were then subdivided into two groups, 40 were assigned rats for each subdivided group, exposed to radiation. The Group 1 was composed of forty non-irradiated rats with normal diet, Group 2 of forty irradiated rats with normal diet, Group 3 forty non-irradiated rats with low calcium diet, and Group 4 forty irradiated rats with low calcium diet. The two irradiation groups received a single dose of 20 Gy on the jaw area only and irradiated with a cobalt-50 teletherapy unit. The rats with normal and low calcium diet groups were serially terminated by ten on the 3rd, the 7th, the 14th, and the 21st day after irradiation. After termination, both sides of the dead rats mandible were removed and fixed with 10% neutral formalin. The bone density of mandibular body was measured by use of bone mineral densitometer(Model DPX -alpha, Lunar Corp., U.SA). Triga Mark ill nuclear reactor in Korea Atomic Research Institute was used for neutron activation and then calcium contents of mandibular body were measured by using a 4096 multichannel analyzer (EG and G ORTEC 919 MCA, U.SA). Also the mandibular body was radiographed with a soft X-ray apparatus(Hitex Co., Ltd., Japan). Thereafter, the obtained microradiograms were observed by a light microscope and were used for the morphometric analysis using a image analyzer(Leco 2001 System, Leco Co., Canada). The morphometric analysis was performed for parameters such as the total area, the bone area, the inner and outer perimeters of the bone. The obtained results were as follows: 1. In the morphometric analysis, total area and outer perimeter of the mandibular bodies of Group 3 were a little smaller than that of Group 1. The mean bone width and bone area were much smaller than that of Group 1 and the inner perimeter of Group 3 was much longer than that of Group 1. The total area and outer perimeter of Group 2 and Group 4 showed little difference. The mean bone width and bone area of Group 4 were smaller than that of Group 2 and the inner perimeter of Group 4 was longer than that of Group 2. 2. The remarkable decreases of the number and thickness of trabeculae and also the resorption of endosteal surface of cortical bone could be seen in the microradiogram of Group 3, Group 4 since the 3rd day of experiment. On the 21st day of experiment, the above findings could be more clearly seen in Group 4 than in Group 3. 3. The bone mineral density of Group 3 was lesser than that of Group 1 and the bone mineral density of Group 4 was lesser than that of Group 2 on the 7th, 14th, 21st days. The irradiation caused the bone mineral density to be decreased regardless of diet. In the case of Groups with low calcium diet, the bone mineral density was much decreased on the 21st day than on the 3rd day of experiment. 4. The calcium content in mandible of Group 3 was smaller than that of Group 1 throughout the experiment. roup 4 showed the least amount of calcium content. The irradiation caused the calcium content to be decreased regardless of diet. In the case of Groups with low calcium diet, the calcium content was much decreased on the 21st day than on the 3rd day of experiment. In conclusion, the present study demonstrated that morphological changs and decrease of bone mass due to resorption of bone by low calcium diet, and that the resorption of bone could be found in the spongeous bone and endosteal surface of cortical bone. So the problem of resorption of bone must be considered when the old and the postmenopausal women are taken radiotherapy because the irradiation seems to be accelerated the resorption of osteoporotic bone.

  • PDF