• 제목/요약/키워드: dentistry radiation

검색결과 301건 처리시간 0.022초

두경부 악성 종양환자에서 조기 방사선치료를 위한 구강관리법에 대한 임상적 연구 (The clinical study of oral care for early radiation therapy in the head and neck cancer patients)

  • 문원규;유재하;차인호;김형준;정영수;이천의;이종영;유미현
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권6호
    • /
    • pp.473-480
    • /
    • 2010
  • Introduction: Tooth requiring extraction before radiotherapy in head and neck cancer patients should be performed as long as possible before the initiation of radiation therapy. Conventionally, a minimum 2-week waiting primary healing period is recommended. Although the above 2-week period is ideal, it is not uncommon for the radiotherapist and cancer patient to feel an urgent need to proceed with radiotherapy despite the need for dental care. Therefore, alternative approaches for early radiotherapy, including conservative endodontic treatment and a 1-week waiting primary healing period after dental extraction at the time of radiotherapy were considered and applied based on a literature review Materials and Methods: The clinical study involved 120 head and neck cancer patients who were treated at Wonju Christian Hospital, Wonju College of Medicine, Yonsei University, from January 1995 to December 2004. Results: In the clinical study, there were no specific complications, such as, post-extraction wound infections, radiation osteitis and osteoradionecrosis over the recent 10 years despite the early radiotherapy. Conclusion: Based on the clinical study, a minimum 1-week waiting primary healing period for oral care before radiotherapy is suitable for early radiotherapy in head and neck cancer patients.

두경부 악성종양 환자에서 조기 방사선치료를 위한 구강관리법에 대한 실험적 연구 (The experimental study of oral care for early radiation therapy in the head and neck cancer patients)

  • 문원규;차인호;김형준;정영수;이천의;이종영;유미현;유재하
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권3호
    • /
    • pp.169-175
    • /
    • 2011
  • Background: Teeth requiring extraction before radiotherapy in head & neck cancer patients should be removed as long as possible before the initiation of radiation therapy. Conventionally, a minimum 2-week waiting primary healing period is recommended. Although the above 2-week period is ideal, it was not uncommon for the radiotherapist and cancer patient to feel an urgent need to process with radiotherapy despite the need for dental care. Therefore, alternative approaches for early radiotherapy, including conservative endodontic treatment and a 1-week waiting primary healing period after dental extraction at the time of radiotherapy, were considered and applied based on the experimental study Materials and Methods: Eighteen dogs were processed for histopathologic wound healing. The effect of the primary endodontic treatment and extraction before early radiotherapy was examined. Results: No specific complication, such as, post-extraction wound infection, radiation osteitis and osteoradionecrosis, were encountered despite the early radiotherapy. Conclusion: Based on the experimental study, a minimum 1-week waiting primary healing period for oral care before radiotherapy is suitable for the early radiotherapy in head and neck cancer patients.

전남 지방에서 치근단방사선사진의 참고 선량 수준 (Reference dose levels for dental periapical radiography in Chonnam Province)

  • 한미라;강병철;이재서;윤숙자;김영희
    • Imaging Science in Dentistry
    • /
    • 제39권4호
    • /
    • pp.195-198
    • /
    • 2009
  • Purpose : To establish reference doses of periapical radiography in Chonnam Province, Korea. Materials and Methods : The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. Results : The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. Conclusion : The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  • PDF

소아치과 영역에서 전산화 단층촬영술의 임상적 활용에 대한 증례보고 (A CASE STUDY ON CLINICAL APPLICATION OF COMPUTED TOMOGRAPHY IN PEDIATRIC DENTISTRY)

  • 이윤석;장기택;이상훈
    • 대한소아치과학회지
    • /
    • 제25권3호
    • /
    • pp.493-498
    • /
    • 1998
  • 1. CT에 의한 매복치의 위치결정은 적절한 치료계획의 수립을 가능하게 하여 시술시간의 단축과 인접치, 인접구조물의 손상을 줄여 시술후의 부작용을 줄일 수 있었다. 2. 매복된 영구치의 견인시 CR를 활용한 결과 개창부위의 정확한 위치결정과 예후에 대한 예측이 가능하였다. 3. 평면방사선사진의 판독후 악골내 병소가 의심되어 CT를 활용한 결과 병소의 확진이 가능하였다. 4. 소아의 CT촬영은 평면 방사선 촬영에 비해 증가된 방사선 피폭량, 높은 수가 때문에 적절한 증례의 선택이 중요하다.

  • PDF

Attitude of the Korean dentists towards radiation safety and selection criteria

  • Lee, Byung-Do;Ludlow, John B.
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.179-184
    • /
    • 2013
  • Purpose: X-ray exposure should be clinically justified and each exposure should be expected to give patients benefits. Since dental radiographic examination is one of the most frequent radiological procedures, radiation hazard becomes an important public health concern. The purpose of this study was to investigate the attitude of Korean dentists about radiation safety and use of criteria for selecting the frequency and type of radiographic examinations. Materials and Methods: The study included 267 Korean dentists. Five questions related to radiation safety were asked of each of them. These questions were about factors associated with radiation protection of patients and operators including the use of radiographic selection criteria for intraoral radiographic procedures. Results: The frequency of prescription of routine radiographic examination (an example is a panoramic radiograph for screening process for occult disease) was 34.1%, while that of selective radiography was 64.0%. Dentists' discussion of radiation risk and benefit with patients was infrequent. More than half of the operators held the image receptor by themselves during intraoral radiographic examinations. Lead apron/thyroid collars for patient protection were used by fewer than 22% of dental offices. Rectangular collimation was utilized by fewer than 15% of dental offices. Conclusion: The majority of Korean dentists in the study did not practice radiation protection procedures which would be required to minimize exposure to unnecessary radiation for patients and dental professionals. Mandatory continuing professional education in radiation safety and development of Korean radiographic selection criteria is recommended.

Insights into the state of radiation protection among a subpopulation of Indian dental practitioners

  • Binnal, Almas;Rajesh, Gururaghavendran;Denny, Ceena;Ahmed, Junaid;Nayak, Vijayendra
    • Imaging Science in Dentistry
    • /
    • 제43권4호
    • /
    • pp.253-259
    • /
    • 2013
  • Purpose: Radiographs is an integral part of patient management in dentistry, despite their detrimental effects. As the literature pertaining to radiation protection among Indian dental practitioners is sparse, exploring such protection is needed. Materials and Methods: All private dental practitioners in Mangalore, India were included in the study. A structured, pre-tested, self-administered questionnaire was employed to assess the knowledge, attitudes, practices, previous training, perceptions towards the need to spread awareness, and willingness to gain and implement knowledge about radiation hazards and protection. Information regarding each respondent's age, gender, education, and type and duration of practice was collected. Results: Overall, 87 out of 120 practitioners participated in the study. The mean knowledge, attitude, and practice scores were $9.54{\pm}2.54$, $59.39{\pm}7.01$, and $5.80{\pm}3.19$, respectively. Overall, 25.3% of the respondents had undergone training in radiation protection, 98.9% perceived a need to spread awareness, and 94.3% were willing to improve their knowledge. Previous training showed a significant correlation with age, sex, and duration of practice; attitude was significantly correlated with education and type of practice; and knowledge scores showed a significant correlation with type of practice. Conclusion: Although the knowledge and practices of respondents were poor, they had a positive attitude and were willing to improve their knowledge. Age, sex, and duration of practice were associated with previous training; education and type of practice with attitude scores; and type of practice with knowledge scores. The findings of this study suggest a policy is needed to ensure the adherence of dental practitioners to radiation protection guidelines.

Development of a standardized mucositis and osteoradionecrosis animal model using external radiation

  • Seo, Mi Hyun;Lee, Min Young;Eo, Mi Young;Lee, Suk Keun;Woo, Kyung Mi;Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권4호
    • /
    • pp.240-249
    • /
    • 2020
  • Objectives: Although the side effects of radiation therapy vary from mucositis to osteomyelitis depending on the dose of radiation therapy, to date, an experimental animal model has not yet been proposed. The aim of this study was to develop an animal model for assessing complications of irradiated bone, especially to quantify the dose of radiation needed to develop a rat model. Materials and Methods: Sixteen Sprague-Dawley rats aged seven weeks with a mean weight of 267.59 g were used. Atraumatic extraction of a right mandibular first molar was performed. At one week after the extraction, the rats were randomized into four groups and received a single dose of external radiation administered to the right lower jaw at a level of 14, 16, 18, or 20 Gy, respectively. Clinical alopecia with body weight changes were compared and bony volumetric analysis with micro-computed tomography (CT), histologic analysis with H&E were performed. Results: The progression of the skin alopecia was different depending on the irradiation dose. Micro-CT parameters including bone volume, bone volume/tissue volume, bone mineral density, and trabecular spaces, showed no significant differences. The progression of osteoradionecrosis (ORN) along with that of inflammation, fibrosis, and bone resorption, was found with increased osteoclast or fibrosis in the radiated group. As the radiation dose increases, osteoclast numbers begin to decrease and osteoclast tends to increase. Osteoclasts respond more sensitively to the radiation dose, and osteoblasts are degraded at doses above 18 Gy. Conclusion: A standardized animal model clinically comparable to ORN of the jaw is a valuable tool that can be used to examine the pathophysiology of the disease and trial any potential treatment modalities. We present a methodology for the use of an experimental rat model that incorporates a guideline regarding radiation dose.

Patient radiation dose and protection from cone-beam computed tomography

  • Li, Gang
    • Imaging Science in Dentistry
    • /
    • 제43권2호
    • /
    • pp.63-69
    • /
    • 2013
  • After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from $19{\mu}Sv$ to $1073{\mu}Sv$ and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.

치과 임상에서 MRI의 활용 (Application of MRI in dentistry: Radiation free image)

  • 전국진
    • 대한치과의사협회지
    • /
    • 제57권11호
    • /
    • pp.700-707
    • /
    • 2019
  • On account of the dentistry mainly deals with hard tissues such as teeth and bones, CBCT and CT are common imaging modality in clinics. Recently, insurance coverage of MRI has been extended to head and neck region. In addition, unlike CBCT or CT, ionizing radiation is not used, the demand for MRI is gradually increasing in dentistry. Even though, many dentists still think that MRI is a difficult diagnostic tool and they are not confident when to use it. Therefore, the objective of this manuscript is to help the dental clinicians to access easily on MRI by introducing the overview, application and precautions of this imaging tool.

  • PDF

Postoperative irradiation after implant placement: A pilot study for prosthetic reconstruction

  • Doh, Re-Mee;Kim, Sungtae;Keum, Ki Chang;Kim, Jun Won;Shim, June-Sung;Jung, Han-Sung;Park, Kyeong-Mee;Chung, Moon-Kyu
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.363-371
    • /
    • 2016
  • PURPOSE. On maxillofacial tumor patients, oral implant placement prior to postoperative radiotherapy can shorten the period of prosthetic reconstruction. There is still lack of research on effects of post-implant radiotherapy such as healing process or loading time, which is important for prosthodontic treatment planning. Therefore, this study evaluated the effects of post-implant local irradiation on the osseointegration of implants during different healing stages. MATERIALS AND METHODS. Custom-made implants were placed bilaterally on maxillary posterior edentulous area 4 weeks after extraction of the maxillary first molars in Forty-eight Sprague-Dawley rats. Experimental group (exp.) received radiation after implant surgery and the other group (control) didn't. Each group was divided into three sub-groups according to the healing time (2, 4, and 8 week) from implant placement. The exp. group 1, 2 received 15-Gy radiation 1 day after implant placement (immediate irradiation). The exp. group 3 received 15-Gy radiation 4 weeks after implant placement (delayed irradiation). RESULTS. The bone mineral density (BMD) was significantly lower in the immediate irradiation groups. BMD was similar in the delayed irradiation group and the control group. The irradiated groups exhibited a lower bone-to-implant contact ratio, although the difference was not statistically significant. The irradiated groups also exhibited a significantly lower bone volume and higher empty lacuna count than the control groups. No implant failure due to local irradiation was found in this study. CONCLUSION. Within the limits of this study, the timing of local irradiation critically influences the bone healing mechanism, which is related to loading time of prostheses.