• Title/Summary/Keyword: dental unit

Search Result 496, Processing Time 0.027 seconds

Bench-Curing Acrylic Resins (ACRYLIC RESIN의 BENCH-CURING에 관하여)

  • Kim, Hyun-Mi
    • Journal of Technologic Dentistry
    • /
    • v.12 no.1
    • /
    • pp.103-106
    • /
    • 1990
  • The purpose of this study was to determine if homogeneity of the resin associated with benchcuring could be obtained in the curing unit as the water increased from room temperature to curing temperature. The results of the experiment were as follows : 1. Long periods of bench-curing are not necessary. 2. Bench-curing can take place in the water bath of the curing unit. When this procedure is used, the water should be far enough below the temerature at which active polymerization of the resin proceeds to allow the bench-curing to occur.

  • PDF

Current trends in intravenous sedative drugs for dental procedures

  • Yoon, Ji-Young;Kim, Eun-Jung
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.2
    • /
    • pp.89-94
    • /
    • 2016
  • Anxiety and phobia in dental procedures are common deterrents for patients visiting the dental care unit. For these individuals, procedural sedation may aid in completion of dental treatments. In most cases, the patients are conscious during sedation, thereby allowing spontaneous ventilation. Intravenous sedation (IVS) is widely used during dental treatment to relieve patient anxiety. IVS is the most effective route of administration to achieve this goal, but it requires advanced training, more than that provided during undergraduate education. During IVS, rapid onset, repetitive drug administration, easy titration, and rapid recovery from sedation can be achieved. However, conscious sedation during IVS can result in deep sedation that can cause respiratory and cardiovascular depression. Therefore, the characteristics of intravenous sedatives should be known. The purpose of this review is to discuss the characteristics and usage of intravenous sedatives currently used for dental procedures.

Three-dimensional functional unit analysis of hemifacial microsomia mandible-a preliminary report

  • Choi, Ji Wook;Kim, Byung Hoon;Kim, Hyung Soo;Yu, Tae Hoon;Kim, Bong Chul;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.28.1-28.7
    • /
    • 2015
  • Background: The aim of this study was to present three-dimensional (3D) structural characteristics of the mandible in the hemifacial microsomia. The mandible has six distinct functional units, and its architecture is the sum of balanced growth of each functional unit and surrounding matrix. Methods: In order to characterize the mandibular 3D architecture of hemifacial microsomia, we analyzed the mandibular functional units of four hemifacial microsomia patients using the 3D reconstructed computed tomography (CT) images. And we compared the functional unit size between affected and non-affected side. Results: The length of condyle and angle showed significant differences between affected and non-affected sides. However, the length of mandibular body showed insignificant differences. The size differences between affected and non-affected side were observed at the condyle, angle, and body in descending order. Conclusions: This preliminary study suggests that the main etiopathogenic units are condyle and angle in the hemifacial microsomia mandible. Further investigation with the increased number of subjects will be helpful to establish treatment modality by etiopathogenic targeting of hemifacial microsomia.

A retrospective comparison of clinical outcomes of implant restorations for posterior edentulous area: 3-unit bridge supported by 2 implants vs 3 splinted implant-supported crowns

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.223-235
    • /
    • 2022
  • PURPOSE. To compare the clinical outcomes of two types of implant restoration for posterior edentulous area, 3-unit bridge supported by 2 implants and 3 implant-supported splinted crowns. MATERIALS AND METHODS. The data included 127 implant-supported fixed restorations in 85 patients: 37 restorations of 3-unit bridge supported by 2 implants (2-IB), 37 restorations of 3 implant-supported splinted crowns (3-IC), and 53 single restorations (S) as controls. Peri-implantitis and mechanical complications that occurred for 14 years were analyzed by multivariable Cox regression model. Kaplan-Meier curves and the multivariable Cox regression model were used to analyze the success and survival of implants. RESULTS. Peri-implantitis occurred in 28.4% of 2-IB group, 37.8% of 3-IC group, and 28.3% of S control group with no significant difference. According to the implant position, middle implants (P2) of the 3-IC group had the highest risk of peri-implantitis. The 3-IC group showed a lower mechanical complication rate (7.2%) than the 2-IB (16.2%) and S control group (20.8%). The cumulative success rate was 52.8% in S (control) group, 62.2% in 2-IB group, and 60.4% in 3-IC group. The cumulative survival rate was 98.1% in S (control) group, 98.6% in 2-IB group, and 95.5% in 3-IC group. There was no significant difference in the success and survival rate according to the restoration type. CONCLUSION. The restoration type was not associated with the success and survival of implants. The risk of mechanical complications was reduced in 3 implant-supported splinted crowns. However, the middle implants of the 3 implant-supported splinted crowns had a higher risk of peri-implantitis.

A Study on Hybrid material of Making Dental restorations by CAD/CAM System (치과 CAD/CAM용 복합소재를 이용한 치과보철물의 제작에 대한 연구)

  • Choi, Beom-Jin
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.86-94
    • /
    • 2014
  • In recent years, perhaps the biggest driver in new material development is the desire to improve crown and bridge esthetics compared to the traditional PFM or all-metal restorations. As such, zirconia, leucite-containing glass ceramic and lithium disilicate glass ceramic have become prominent in the dental practice. Each material type performs differently regarding strength, toughness, ease of machining and the final preparation of the material prior to placement. For example, glass ceramic are typically weaker materials which limits its use to single-unit restorations. On the other hand, zirconia has a high fracture toughness which enables multi-unit restorations. This material requires a long sintering procedure which excludes its use for fast chair side production. Developed hybrid material of CAD/CAM is contained nano ceramic elements. This new material, called a Resin Nano Ceramic is unique in durability and function. The material is not a resin or composite. It is also not a pure ceramic. The material is a mixture of both and consists of ceramic. Like a composite, the material is not brittle and is fracture resistant. Like a glass ceramic, the material has excellent polish retention for lasting esthetics. The material is easily machined chair side or in a dental lab, polishes quickly to an esthetic finish and if necessary, can be useful restoratives.

Three-dimensional evaluation of the internal adaptation of single and three-unit fixed dental restoration by CAD/CAM milling system (CAD/CAM 밀링 시스템을 활용한 단일 치관과 3본 교의치의 3D 적합도 평가)

  • Kim, So-Ri;Kim, Chong-Myeong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • Purpose: The purpose of this paper was to evaluate the occurrence of errors regarding adaptation by conducting a three-dimensional assessment comparing the bridge type dental restoration after the cutting process, which has multiple abutments, with a single type dental restoration. Methods: By using ten identical files obtained by scanning the master model, thirty designs were created consisting of ten maxillary right first premolars and ten maxillary right first molars with single crown abutments, along with ten bridge designs with the identical abutment. A 5-axis milling machine was used to produce the design file. The produced denture prostheses were scanned using a silicone replica for a STL file. An evaluation was conducted using 3D analysis software on the master model and each of the thirty data files. Results: The RMS value of the pre-molar (14) was $38.4{\pm}4{\mu}m$ for single and $54.7{\pm}6{\mu}m$ for bridge abutment; therefore, a statistically significant difference was observed for single and bridge designs although both shared the same abutment form (P<.05). Also, the RMS value of the molar (16) was $47.6{\pm}2{\mu}m$ and $56.6{\pm}5{\mu}m$ for the single and bridge designs, respectively, thereby presenting a statistically significant difference (P<.05). Conclusion: As a result, dental prosthesis fabricated using the single method presented better internal adaptation outcomes.

Comparison the fit of three-unit metal framework fabricated by wax milling method and digital light projection method (왁스 밀링 방법 및 디지털 광 프로젝션 방법으로 제작된 3본 금속 구조물의 적합도 비교)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.41 no.1
    • /
    • pp.9-19
    • /
    • 2019
  • Purpose: This study was conducted to comparative evaluate the marginal and internal gap of three-unit metal frameworks(Co-Cr) fabricated by wax milling method and digital light projection method of CAD/CAM systems. Methods: All the specimens were fabricated by three different fabrication methods: conventional wax up with casting(CWC), milled wax block with casting(MWC), digital light projection with casting(DLPC) (n=10 each). The marginal and internal fits of specimens were examined using a replica technique. The light-body silicone thickness was measured at 8 reference points(each abutment: 16 measurements). All measurements were conducted by a stereomicroscope. Digital photo were taken at $150{\times}$ magnification and then analyzed using a measurement software. The Mann-Whitney test was used for analyzing the results. Results: Statistically significant differences were found between the fabrication methods(p<0.001). The mean(SD) is ${\mu}m$ for fabrication methods, the mean marginal fit were recorded respectively, CWC 63(38), MWC group 50(33), DLPC 103(54) and the mean internal fit CWC 96(47), MWC group 116(41), DLPC 138(66). Conclusion : The marginal and internal fit were statistically different according to the fabrication methods(p<0.001). In all fabrication methods, the greatest misfit was found the occlusal area of all specimens.

A System for Describing Cis-Regulatory Machinery Unit

  • Kaminuma, Tsuguchika;Takai-Igarashi, Takako;Yukawa, Masumi;Tanaka, Yoshitomo;Tanaka, Hiroshi
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2005.09a
    • /
    • pp.427-430
    • /
    • 2005
  • Studies on cellular pathways and networks are now one of the most actively researched topics in all fields of biomedicine ranging from developmental biology to etiology. Many databases have been developed and quantitative simulation models have been proposed. One of the eventual goals of pathway/network studies is to integrate different types of pathway/network models and databases to simulate overall cellular responses. A bottleneck to this goal is modeling gene expression since the mechanism of this process is not yet fully unveiled. We are developing a small scale computer program called CiRMU (Cis-Regulatory Machinery Unit model) for describing, viewing, analyzing, and modeling the process of gene expression. A prototype system is being designed and implemented for analyzing functions of nuclear receptors.

  • PDF

The Associations between the Term of Establishment, the Scale, the Payment System and the Salary, and Productivity of Dental Laboratories in Seoul (서울시 소재 일부 치과기공소의 개업연한, 규모, 임금제도 및 임금수준과 생산성과의 관계)

  • Kim, Eum-Sook
    • Journal of Technologic Dentistry
    • /
    • v.18 no.1
    • /
    • pp.73-94
    • /
    • 1996
  • This study was aimed for evaluating the validity of relative-productivity index on the basis of working hour(RPHW index) designed by author as new productivity index and drawing up a plan of bettering productivity to cope with financial difficulty of dental laboratories. Fortyeight dental laboratories extracted by cluster-sampling method form all the dental laboratories in Seoul were subjected for this study. And in each of them, the term of establishment which was divied into three group as short-term, mid-term and long-term group, the scale of dental laboratory which as divided into two group by number of dental technician as small-scale group and large-scale group, the salary system which was composed of salary criteria, pay according to ablility criteria and collectiveagree, the salary level, simple labor productivity index(SLP index), relative-productivity index on the basis of worker number(ROWN) and relative-productivity index on the basis of working hour(RPWH index) were surveyed through the self-administractive questionaires. The results as follows : Most of dental laboratories(93.6%) were managed by non-professional managers. The establishment rate per year of dental laboratory was the increase. The mean number of employees of dental laboratories was $7.00{\pm}3.90$ person. The ratio of smallscale group(under the 5 employees) was 42.6% and as the term of establishment was shorter, the ratio of small-scale group was higher. The mean establishment area of dental laboratories was $24.49{\pm}10.97$ unit and the mean establishment area per head of dental laboratories was $4.05{\pm}3.90$ unit. The estabilshment area and area per head were not significantly associted with the term of establishment, but as the term of establishment was shorter, the estabkishment area per head was slightly wider. The establishment area per head in small-scale group was significantly wider than large-scale group(over the 6 emplayees) The salary criteria(54.4%), pay according to ability(79.2)m ability criteria(77.1%) and collectiveagree(79.2%) as salary systems were used in the most of all dnetal laboratoies. The all salary systems were not significantly associated with the term of establishment and the scale of dental laboratories. The monthly mean salary level of dental laboratoies was $125.64{\pm}31.06$ milion won. The monthly salary level was not significantly associated with the term of establishment and the scale of dental laboratores. But the monthly salary level in the short-term group and the small-scale group were slightly lower than others. The SLP index, the RPWN index and the RPWH index of dental laboratories were $132.16{\pm}48.41$, $382.41{\pm}128.76$ and $76.06{\pm}25.11$, respectively. The SLP, the RPWN and the RPWH of dental laboratories were not significantly associated with the term SLP, the RPWN and the RPWH of dental laboratories were significantly associated with the area of dental laboratory and the salary level. Except for only the association salary criteria among salary system with RPWH of dental laboratories, all other salary system were not associated with the SLP, the RPWN and the RPWH of dental laboratories.

  • PDF