• 제목/요약/키워드: dental stone

검색결과 182건 처리시간 0.03초

한국인의 연영증가에 따른 치아교모도에 관한 연구 (STUDY ON THE DEGREE OF TEETH ATTRITION WITH AGE INCREASE OF THE KOREAN)

  • 이명종
    • 대한치과의사협회지
    • /
    • 제10권7호
    • /
    • pp.445-450
    • /
    • 1972
  • The author collected 93 male stone model and 93 female stone model of upper and lower jaw of the koreans as samples and studied the degree of attrition with age increase. Determining the degree of attrition, each normal cusp were given 40 points and calibrated into percentage. The percentage score were examined and analized, and came to the following conclusions. 1) Increased age were found graudually higher the degree of attrition at 10 to 20 age,. The degree of attrition presented localized disappearance of marginal-ridges and marginal grooves. At 30 up to 40 age, about 40 to 50% of the degree of attrition were found gradually on cusp ridges and grooves At 50 to 60 age, it was found about 70 to 80% of attrition. 2) Male score was slightly higher than female. 3) There was no significant difference between male and female score.

  • PDF

드릴 반경 설정이 보철물 가공에 미치는 영향 (Effect of drill radius setting on prosthesis machining)

  • 김총명;김소리;조미향
    • 대한치과기공학회지
    • /
    • 제40권1호
    • /
    • pp.1-8
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the trueness and fitness of machined prostheses according to drill radius setting in CAD software. Methods: For this study, standard abutment were replicated in Type IV stone. The stone abutment were scanned using a dental scanner. The CAD design software was designed using scanned abutment data. When designing, the drill radius was set to 0.3 mm and 0 mm, respectively, and saved. The saved design data was milled using a milling machine (n=13). The inner surface of the milled crown was scanned. The trueness and fitness were measured using the inner scan data of prostheses. Independent t-tests were performed to identify significant differences in each data. Results: Trueness values of the data saved with 0.3 mm and 0 mm drill radius were $18.9{\pm}2.3{\mu}m$ and $19.1{\pm}0.9{\mu}m$, respectively. There was no statistically significant difference between the groups. Fitness values of the data saved with 0.3 mm and 0 mm drill radius were $65.5{\pm}0.8{\mu}m$ and $33.8{\pm}1.0{\mu}m$, respectively. There was a statistically significant difference between the groups (p<.05). Conclusion : Setting the drill radius is important to produce clinically good fit prostheses.

Development of Novel Dental Chews for Dogs Considering Breed Variations in Anatomical Features of Dentition

  • Noh, Hyun-woo;Kang, Seon-mi;Seo, Kangmoon
    • 한국임상수의학회지
    • /
    • 제34권6호
    • /
    • pp.429-433
    • /
    • 2017
  • The purpose of this study was to find anatomical variation of each small breed dog's dentition for designing more effective dental chews. Small breed dogs were volunteered for dental impressions with dental stone and alginate under tiletamine-zolazepam, tramadol, and medetomidine intravenous anesthesia. Twenty-two criteria were measured to compare dental impressions. Twenty-five dogs (9 Malteses, 8 Miniature Poodles, and 8 Shih-Tzus) were recruited. Statistically, Shih-Tzus had smaller teeth and shorter interdental spaces than those of Maltese and Miniature Poodles. Grossly, the distance between upper teeth and lower teeth was wider in Shih-Tzus. Shih-Tzu had different dental anatomy in comparative to Miniature Poodle and Maltese. It was recommended to design the dental chew considering these differences.

Accuracy of casts produced from conventional and digital workflows: A qualitative and quantitative analyses

  • Abduo, Jaafar
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.138-146
    • /
    • 2019
  • PURPOSE. Comparing the accuracy of casts produced from digital workflow to that of casts produced from conventional techniques. MATERIALS AND METHODS. Whole arch alginate (ALG) and polyvinyl siloxane (PVS) impressions were taken with stock trays and custom trays, respectively. The ALG impressions were poured with type III dental stone, while the PVS impressions were poured with type IV dental stone. For the digital workflow, IOS impressions were taken and physical casts were produced by 3D printing. In addition, 3D printed casts were produced from images obtained from a laboratory scanner (LS). For each technique, a total of 10 casts were produced. The accuracies of the whole arch and separated teeth were virtually quantified. RESULTS. Whole arch cast accuracy was more superior for PVS followed by LS, ALG, and IOS. The PVS and ALG groups were inferior in the areas more susceptible to impression material distortion, such as fossae and undercut regions. The LS casts appeared to have generalized errors of minor magnitude influencing primarily the posterior teeth. The IOS casts were considerably more affected at the posterior region. On the contrary, the IOS and LS casts were more superior for single tooth accuracy followed by PVS and ALG. CONCLUSION. For whole arch accuracy, casts produced from IOS were inferior to those produced from PVS and ALG. The inferior outcome of IOS appears to be related to the span of scanning. For single tooth accuracy, IOS showed superior accuracy compared to conventional impressions.

중증치주염이 치수조직에 미치는 영향 (The effect of advanced periodontitis on the dental pulp tissue)

  • 김병옥;박영란;윤정훈;장현선
    • Journal of Periodontal and Implant Science
    • /
    • 제35권2호
    • /
    • pp.311-319
    • /
    • 2005
  • In order to examine the effects of advanced periodontitis on the dental pulps, 38 extracted human teeth were examined histologically. The 38 teeth had a positive or negative state in the electric pulp test(EPT). In addition, almost of the 38 teeth had a deep pocket and severe mobility, and floating state. A medical and dental history was elicited. The extracted teeth fixed in 10% neutral formalin solution. The general tissue processing method was followed. The tissue block including the teeth was prepared for optical microscopy using hematoxillin-eosin staining. Among the 38 periodontally involved teeth, the dental pulps were respectively intact in 12(31%), and a pulp stone(or linear calcifications) was found in 18 teeeth(47%). In addition, 17 teeth(44%) had pulps exhibiting inflammatory reactions with varying intensities, such as hyperemia, pulp abscess, pulp necrosis. Among the 38 periodontally involved teeth, 37 teeth tested a positive to the EPT, and 7 teeth tested negative. The EPT positive 37 teeth had various histological features such as 7 normal pulp(18%), 17 pulp stone(44%), 1 hyperemia (2%), 9 pulpitis(23%), 5 root resorption(13%), 3 pulp abscess(7%), and 3 pulp necrosis(7%), In conclusion, it is suggested that in the EPT positive teeth, advanced periodontally involved teeth can cause inflammation of the dental pulp.

혼수비에 따른 초경석고의 파절강도 (FRACTURE STRENGTH OF IMPROVED DENTAL STONE ACCORDING TO WATER/POWDER RATIO)

  • 엄정희;박찬운;박광선
    • 대한치과보철학회지
    • /
    • 제39권2호
    • /
    • pp.220-229
    • /
    • 2001
  • This study was performed to evaluate the fracture resistance of three improved die stone materials according to water/powder ratio. There are lots of handling conditions which affect the physical properties of improved dental stone, and it's well known that the water/powder ratio significantly affect the strength of die stone. If water/power ratio was incorrect, following disadvantages were showed : (1) susceptibility to dimensional change due to abrasion, (2) limited reproduction of fine detail, (3) lack of strength. The maxillary master casts were made of additional silicone impressions(Exaflex, GC America. Inc. USA). Three type IV die stones such as Fuji Rock (GC Europe Intreleuvenlaan, Leuven, Belgium), Velmix(Kerr, Manufacturing company, USA), and Crytal Rock( Maruishi Gypsum Co. Ltd, Japan) were tested. A total of 160 casts were prepared, separated, and tested on the Instron Testing Machine(Model 4201, Co. USA). The obtained results of this study were as follows : 1. Fuji Reck and Velmix less 3ml than the water/power ratio of manufacturer's instruction showed the highest resistance to fracture. According to increasing water/powder ratio, fracture resistance was significantly increased(P<0.05). Crystal Rock showed the highest fracture value when it was mixed with the water/power ratio of manufacturer's instruction. 2. Water/powder ratio of the manufacturer's instructions and less 3ml than that showed lower fracture value of hand mix than that of vacuum mix. Water/powder ratio of more 3ml, 6ml than manufacturer's instructions was not significantly different between hand mix and vacuum mix(p>0.05). 3. Velmix had the highest viscoelastic value among three die materials when it was mixed with the manufacturer's instruction. Viscoelasticity was decreased according to increasing water/powder ratio.

  • PDF

친수성 고무인상재의 침적 소독이 경석모형의 크기의 안정성과 표면경도에 미치는 영향 (EFFECT ON IMMERSI0N DISINFECTION OF HYDROPHIILIC RUBBER IMPRESSI0N MATERIAL ON DIMENSIONAL STABILITY AND SURFACE HARDNESS OF IMPROVED STONE CAST)

  • 남미현;강우진;정문규
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.569-583
    • /
    • 1995
  • Disinfection of dental impressions are necessary due to contamination with patient’s saliva and blood, which is a potential for cross-infection. The purpose of this study was to evaluate the effects of disinfection of four hydrophilic rubber impression materials with three disinfecting solutions, on the dimensional stability and surface hardness of improved stone casts. Three hydrophilic vinyl polysiloxane impression materials(Express, Reprosil, Exafine) and one polyether impression material(Impregum-F) were mixed according to the manufacturer’s directions and impressions were made on a ADA specification No. 19 stainless-steeldie. On removal of the impressions, each impression was immersed in one of the disinfectants(Banicide, Potadine, Clorox) for 10 minutes. After disinfection, type IV improved stone. casts were poured. On this cast, the linear dimension and surface hardness were measuredusing a Measurescope(Nikon, Japan) and a Barcol hardness tester(Barber, Colman Co U. S. A). The results were as follows : 1. The improved stone casts from disinfected Reprosil and Impregum-F impression material did not show dimensional changes(P>0.01). Those from disinfected Express and Exafine impression material showed dimensional changes(P<0.01). The amount of shrinkage was not clinically significant. 2. The improved stone casts from disinfected Express impression material did not exhibit changes in surface hardness(P>0.01), but those from disinfected Reprosil, Exafine, Imp regnum-F impression material showed changes in surface hardness(P<0.01). 3. The dimensinal stability and surface hardness of the improved stone casts were satisfactory using Banicide on Express, all disinfectants used in this study on Reprosil, Potadin and Clorox on Exafine, Banicide and Clorox on Impregum-F. According to these results, immersion disinfection of hydrophilic rubber impression mate rials did not adversely affect the resultant casts. Nevertheless compatibility tests of impression materials and disinfectants should be done when disinfecting impressions.

  • PDF

유치열기(乳齒列期) 아동(兒童)의 치궁발육(齒穹發育)에 관(關)한 연구(硏究) (GROWTH CHANGES OF DENTAL ARCHES DURING THE DECIDUOUS DENTITION PERIOD)

  • 변인숙
    • 대한소아치과학회지
    • /
    • 제7권1호
    • /
    • pp.63-74
    • /
    • 1980
  • The purpose of this study is to analyze the width and length changes of the dental arches during the deciduous dentition period. 600 stone models of maxillary and mandibular arches obtained from the children aged 3, 4, or 5 years were under measurement. The results were as follows ; Arch widths and lengths differed with age, sex and arch. 1. * Widths of dental archs increase with age both in males and in females. * Lengths of dental arches decrease with age in females, but remain somewhat stable in males. 2. * The dental arches of males were wider than those of females in both the ant. and the post. section. * The dental arches of males were longer than those of females: ant.arch lengths were almost same, but post. arch lengths were longer in males. 3. * Upper arches were definitely wider and longer than lower arches.

  • PDF

The level of buccal gingival margin around single and two adjacent implant restorations: a preliminary result

  • Kim, Young-Bum;Shim, June-Sung;Han, Chong-Hyun;Kim, Sun-Jai
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권3호
    • /
    • pp.140-144
    • /
    • 2009
  • STATEMENT OF PROBLEM. Little information is available about the buccal gingival level of multiple implant restorations. PURPOSE. This study was aimed to evaluate the relationship between width and height of buccal soft tissue around single and 2 adjacent implant restorations. MATERIAL AND METHODS. Four implant restoration groups (first and second molars, single second molars, posterior single restorations between teeth, and anterior single restorations between teeth) were randomly chosen from one dental institute. Each group comprised of 6 patients. After 6 months of function, silicone impressions were taken and stone models were fabricated for each restoration group. The stone models were cut in bucco-lingual direction at the most apical point of buccal gingival margin. The height and width of buccal supra-implant soft tissue were measured. One way ANOVA and Tukey HSD post hoc tests were performed to analyze the data obtained (P < .05). RESULTS. The most unfavorable width-height ratio was noted for the group, which was comprised of the second molar in the multiple adjacent (first and second molar) implant-supported restorations. The group also resulted in the shorter height of buccal supra-implant mucosa rather than that of anterior single implant restorations between natural teeth. CONCLUSION. To achieve a favorable level of buccal gingival margin, greater thickness of buccal supra-implant mucosa is required for the implant restorations without a neighboring natural tooth compared to the implant restorations next to a natural tooth.

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.