• 제목/요약/키워드: dental stone

검색결과 182건 처리시간 0.03초

치관보철물 제작시 사용되는 치형 재료에 따른 치경부 변인의 적합성에 관한 연구 (A Study on the Suitability of Cervical Margin According to Die Materials Used in Crown Prosthesis)

  • 이인규;최운재;정희선
    • 대한치과기공학회지
    • /
    • 제22권1호
    • /
    • pp.5-12
    • /
    • 2000
  • The gaps between the die margin worked and the casting body were measured with an optical microscope and compared after making crown prosthetic materials using three kinds of die material - dental stone, extra hard stone, epoxy resin - used in crown prosthesis. The results are as follows : 1. All the gaps between the cast cervical margin and the casting bodies were relatively good regardless of die materials used with the gaps under $50{\mu}m$, the allowable limit. 2. The cervical margin suitability of epoxy resin die was the highest among the three kinds of die material with the suitability value of $30.28{\pm}12.67$. 3. Among the four surfaces(buccal, lingual, mesial, distal) of all the casting bodies, buccal surface was the highest in the cervical margin suitability with the value of $25.93{\pm}15.51$.

  • PDF

석고제품(石膏製品)에 촉진제(促進劑) 사용시(使用時) 경화시간(硬化時間) 및 경도(硬度)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究) (An Investigation of How the Accelerator Effects the Setting Time and The Headness of Plaster Products)

  • 황성식
    • 대한치과기공학회지
    • /
    • 제19권1호
    • /
    • pp.43-54
    • /
    • 1997
  • This investigation is carried out of inqurie into the effects of the accelerator on the setting time and haedness when it is used with plaster products. Plaster($\beta$), dental hard stone($\alpha$), and limproved dental hard stone($M{\alpha}$) are selected as the objects of the investigation, since they are most common materials for dental plaster products. Setting time is gauged by means of Vicket Needle and Gilmore Needle, and hardness is gauged by means of Brinell and Vicket Hardness machines. Samples of each material are made in the standerd water powder ratio and with the accelerator repectively, Every material is tested five times each. The results of the tests are as fallow : 1) In each case the setting time is shortened when the accelerator is used. 2) Of the three materials the hardness of the plaster was lowest A($\beta$) < B($\alpha$) < C($M{\alpha}$)} 3) In each case the hardness of the samples made in the standard water powder ratio were higher than that of the sample made with the accelerator. A1 > A2 ; B1>B2 ; C1>C2 4) Final Conclusion : Higher quality cast is expected when it is made in the standard water powder ratio.

  • PDF

Blue LED 방식의 스캐너로 제작된 치과용 3차원 디지털 모형의 정확도 평가 (Evaluation of validity of three dimensional dental digital model made from blue LED dental scanner)

  • 김재홍;정재관;김기백
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3007-3013
    • /
    • 2014
  • 본 연구의 목적은 블루 LED 기반의 치과용 스캐너를 이용하여 제작된 3차원 디지털 모형의 정확도를 평가하는 것이다. 본 연구를 위하여 20개의 동일한 석고 모형 제작 후 블루 LED기반의 치과용 스캐너를 이용하여 석고 모형과 동일한 20개의 3차원 디지털 모형을 제작하였다. 정확도를 평가하기 위해 두 집단의 모형을 대상으로 6개의 계측 거리를 지정한 후 측정하였다. 통계분석은 비모수 검정법인 윌콕슨 순위 합 검정법을 이용하여 비교 분석하였다(제1종 오류수준=0.05). 비록 모든 부위에서 디지털 모형이 석고 모형보다 작은 것으로 분석되었으나(p<0.05), 임상적 허용 수치를 벗어나지 않았다.

동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로 (Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system)

  • 김재홍
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.

다양한 석고 분리제를 이용한 치과용 석고의 표면 특성에 관한 연구 (The Surface Properties using various separating materials of dental gypsum products)

  • 성환경;이규선;황재선
    • 대한치과기공학회지
    • /
    • 제30권1호
    • /
    • pp.17-23
    • /
    • 2008
  • Gypsum products are used for the preparation of stone casts of oral and maxillofacial structures and as important adjuncts to dental laboratory operations involved in the production of dental prosthesis. Accuracy and dimensional stability over time are properties of concern in fixed prothodontics. Gypsum products used in denstry are a form calcium sulfate hemihydrate and are classified as 1 of 5 types according to International Standard Organization(ISO) 6873. All die materials exhibit some dimensional change during setting, but expansion and contraction during setting and dimensional changes in response to varations in temperature and the water-powder ratio must be minimal. Although numerous investigators have studied the properties of die materials, several products have been introduced recently with manufacturer claims of superior dimensional stalility. The aim of this study was to determine the surface properties using various separating materials of dental gypsum products The results were as follows 1. In the comparison of first and second plaster distances before separation in different separating agent, there was no significant difference except using Trio separating agent. The interface using Trio separating agent forms like to pores. 2. In the comparison of first and second plaster distances after separation in different separating agent, there was significant difference. The interface of plasters using WD-40, Trio and Vaseline was showed some gaps. Each they were measured at average 7.97 $\pm$ 2.07 ${\mu}m$, 63.09 $\pm$ 23.25 ${\mu}m$, 27.59 $\pm$ 4.19 ${\mu}m$. 3. In the comparison of the surface, the surface of control sample(using none seperating agent) showed irregular properties and the surface using Trio and Vaseline become wrinkled. Specially the surface using Vaseline was showed shiny properties. But the surface using MAGIC SEP, Plaster seperating agent, WD-40 showed regular properties.

  • PDF

신개발 국산 부가중합 실리콘 인상재의 젖음성과 기포발생에 관한 비교 연구

  • 조리라;정경호;김경남
    • 대한치과의사협회지
    • /
    • 제41권1호통권404호
    • /
    • pp.35-41
    • /
    • 2003
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined theimpression quality in clinical condition and the wettability of impression material. Three commercially available addition silicone impression material (Imprint; 3M, USA, Examix; GC, Japan, Perfect; Handae, Korea) were studied. A total of 90 putty/wash impressions of semi-dried premolars and wet molar teeth were examined for void production in impression body. The percentae of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned casts from the impressions with stereomicroscope. Three impression materials were used to produce die stone casts from vcid entrapment die. Voids in the stone casts were counted with the stereomicroscpe. From the experiment, the following results were obtained: 1. In direct observation, Imprint showed greatest numbers of void in impression body (P<.001).However, correlations were not found between sulcus reproduction and void production. 2. Sulcus reproduction ability of additional silicone impression material was diminished in order of Imprint, Examix, Perfect. The significant difference was found between Imprint and other material (P<.001). 3. In void entrapment laboratory test, void productions was diminished in order of Examix, Imprint, Perfect. All voids in casts were less in delayed poured cast than immediately poured cast. 4. Especially, the stone pouring time of Perfect impression material should be delayed.

  • PDF

교합면의 교모형태에 따른 치과용 모형 스캐너의 정확도 평가 (Accuracy evaluation of dental model scanner according to occlusal attrition type)

  • 김동연;김지환;이범일;이주희;김원수;박진영
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study is to compare and analyze the accuracy of single crowns based on the type of occlusal surface. Methods: A single crown wax pattern was fabricated in three types of occlusal surface. The prepared wax pattern was replicated with silicone, and stone was injected to create a stone model. The prepared specimens were scanned using a model scanner. Scans were classified into three groups, and each scan was performed six times to analyze the trueness and precision of a single crown. In addition, only the occlusal surface area was analyzed for trueness and precision. Data were analyzed using the Kruskal-Wallis H test, a nonparametric test (α=0.05). Results: With regard to the trueness value of the occlusal scan area, the no occlusal tooth attrition (NA) group showed the largest error of 3.5 ㎛, and the complete occlusal tooth attrition (CA) group showed the lowest value of 3.1 ㎛. The NA group had the greatest precision, and the medium occlusal tooth attrition (MA) group and CA group showed a low precision value of 3.2 ㎛; the difference between the groups was statistically significant (α=0.05). In the color difference map, the CA group showed a lower error than the NA group. Conclusion: The occlusal surface with severe attrition had excellent accuracy, but the accuracy of the group without attrition was low. There were significant differences between groups, but clinically acceptable values were shown.

석고 모형으로부터 분리 배양된 미생물에 관한 연구 (A study on isolated microorganisms from dental cast)

  • 최주영
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.321-332
    • /
    • 2013
  • Purpose: This study was examined the characteristics of bacteria isolated from the dental stone that is made ??in the dental laboratory. Methods: 104 dental stones samples were collected from the 4 dental laboratory. Characteristics of bacteria were investigated by microorganism isolation culture method using a Blood Tryptic Soy Agar(TSA) medium. Results: The detected various bacteria was confirmed as pathogenic bacteria, non-pathogenic bacteria and natural bacteria. The isolated bacterial number was confirmed $2.9{\times}10^3CFU$ and maxium bacterial number of $3.0{\times}10^4CFU$. Conclusion: Therefore, infection prevention education is required, it must be to live up the hand-washing and wear protective clothing to protect themselves when working in a dental laboratory.

총의치 제작을 위한 무치악 디지털 모형의 정확도 평가 (Evaluation of Validity of Edentulous Digital Model for Complete Denture Fabrication)

  • 김원수;김기백
    • 치위생과학회지
    • /
    • 제15권4호
    • /
    • pp.393-398
    • /
    • 2015
  • 성공적인 보철치료를 위해서 가장 필요한 선행조건 중 하나는 환자의 구강과 정확한 모형의 제작이다. 최근 치과용 캐드캠을 이용한 보철물의 제작 수요가 증가함에 따라 본 연구에서는 총의치 제작을 위한 디지털 모형의 정확도를 평가함으로써 해당 임상가(치과의사, 치과위생사, 치과기공사)들에게 참고자료를 제시하고자 하였다. 이를 위해 기존 아날로그 제작 방식에 의한 석고 모형(대조군)과 이를 스캔하여 제작한 디지털 모형(실험군)을 각각 20개씩 제작 후 정확도 평가를 위한 6개의 계측지점을 선정하였다. 두 집단의 모형에서 측정된 6개의 계측지점의 평균을 비교 평가하는 방식으로 디지털 모형의 정확도를 평가하였다. 본 연구 결과 치과용 스캐너를 이용하여 제작된 디지털 모형이 아날로그 모형보다 작게 제작된다는 것을 알 수 있었으나 이는 통계적으로 유의하지 않았다. 또한 두 집단의 모형들에서 측정된 계측거리의 평균의 차이는 계측거리 별로 0.05~0.45 mm로 조사되었는데, 이러한 차이는 기존 선행 연구들에 근거하였을 때 그 정도가 미비한 것으로써 최종 보철물의 성패에는 영향을 미치지 않는 것을 알 수 있었다. 최근 치과용 캐드캠을 이용한 보철물의 제작 수요는 증가하고 있는데 반해 디지털 모형의 정확도와 관련한 연구는 매우 부족한 것을 감안하였을 때 본 연구는 관련 실험을 통해 결과를 도출하여 해당 임상가(치과의사, 치과위생사, 치과기공사)들에게 참고자료를 제시하고자 하였다는 점에서 의의가 있다고 생각된다. 본 연구 결과들을 종합하고, 선행 연구들의 결과에 비추어 보았을 때 치과용 캐드캠을 이용한 총의치 제작 시 제작되는 디지털 모형은 임상적으로 허용이 가능할 것으로 기대된다.