• 제목/요약/키워드: dental stone

검색결과 182건 처리시간 0.023초

세 가지 방식으로 제작된 레진코핑의 내면적합성 평가: 3차원적 분석 (Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis)

  • 강신영;박진영;김동연;김웅철
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the traditional and Digital manufacturing methods through 3-dimensional analysis. Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD). Results: Three groups are measured $47.11{\pm}(3.08){\mu}m$ total RMS of SLAC group, $48.35({\pm}1.55{\mu}m)$ for total RMS of LAPC group, $43.45{\pm}2.09{\mu}m$ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321). Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three-ways methods showed that no differences statistically significant and clinically acceptable results.

Evaluating the accuracy (trueness and precision) of interim crowns manufactured using digital light processing according to post-curing time: An in vitro study

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kim, Dong-Yeon;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.89-99
    • /
    • 2021
  • PURPOSE. This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to post-curing time. MATERIALS AND METHODS. A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute post-curing interim crown (20-MPCI), and 30-minute post-curing interim crown (30-MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces (P<.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. CONCLUSION. Interim crowns with 10-minute post-curing showed high accuracy.

출력 지지대 두께가 선택적 레이저 용융법으로 제작된 금속 하부구 조물 적합도에 미치는 영향 (Effect of support thickness on the adaptation of Co-Cr alloy copings fabricated using selective laser melting)

  • 김재홍;김세연
    • 대한치과기공학회지
    • /
    • 제45권3호
    • /
    • pp.67-73
    • /
    • 2023
  • Purpose: This in vitro study aimed to evaluate the clinical acceptability of precision of fit of the support thickness of Co-Cr alloy copings fabricated using selective laser melting (SLM). Methods: Thirty dental stone models of maxillary left molar abutments were manufactured, images were taken using a scanner, and a computer-aided design program was used to design the form of a conventional metal ceramic crown coping. Overall, 30 single copings were made from Co-Cr alloy using SLM and divided into three support radius groups (0.1, 0.25, and 0.35 mm) of 10 for each. Digitized data were superimposed with three-dimensional inspection software to quantitatively obtain the machinability of a ceramic crown coping, and visual differences were confirmed using a color map. The root mean square values of the ceramic crown coping group were statistically analyzed using one-way analysis of variance (α=0.05). Results: The precision of fit was superior with 0.25 mm compared with 0.1 mm and 0.35 mm, and the results exhibited significant differences (p<0.05). All specimens showed that various support thicknesses did not exceed the clinically permitted value of 120 ㎛, which mean that more than 0.1 mm and 0.35 mm of support radius for SLM was adequate. Conclusion: The support thickness of Co-Cr alloy restoration fabricated using SLM is shown to affect the adaptation.

노인환자의 보존치료

  • 임성삼
    • 대한치과의사협회지
    • /
    • 제20권12호통권163호
    • /
    • pp.1011-1013
    • /
    • 1982
  • 년령이 증가함에 다라 치아도 신체 다른부위와 같이 노화현상이 나타나는데, 특히 보존영역에서는 상아질 및 치수의 노화에 대한 지식은 매우 중요하다고 생각된다. 일반적으로 상아질 및 치수의 노화는 치수강이나 치근관내 석회화된 조직의 양이 증가하고 세포나 혈관의 수가 감소되는 현상으로 나타나며, 임상에서는 흔히 치수강이나 치근관내 pub stone이나 dystrophic calcification을 발견하게 된다. 이러한 노화현상은 년령이 증가한다는 요소외도 우식, 마모, 교모, 또는 치과시술등이 그 원인이 된다고 알려져 있으며 실제 젊은환자에서도 상아질 및 치수가 노화되어 있는 치아를 볼 수 있다. 그러나 대개 년령적으로는 50세에서 60세사이의 환자에서는 치아의 노화가 있을수있는 가능성이 많다고 알려져 있으므로 임상에서 이점을 고려해야될 것으로 생각되며, 또 한가지는 상아질 및 치수에 이와같은 치유의 능력이 저하된다는 사실이다. 이러한 사실은 우리가 광범위한 충전물을 가진 치아에서 치수복조술을 시행할때는 충전물이 없고 우식이 생긴 치아에서 시술여부를 결정할 때 매우 중요한 점이 되고있는것 처럼 보존시술시 고려되어야 할 중요한 점으로 생각된다. 노인에서 보존치료의 결과는 환자가 신장질환이나 위장병, 폐결핵, 당뇨병등 만성적인 전신 질환을 가지고 있는 경우에는 그 치유가 지연되는 경우가 있기는 하나 시술시에 이러한 사실과 년령증가에 따른 치수 및 상아질의 형태학적 변화나 생리적변화등을 고려해서 치료술식을 약간 달리하면 젊은 환자에서와 똑같은 결과를 가져 올수 있다는 확신 또는 중요하다고 보겠다. 본 난에서는 노인환자의 보존치료시에 임상에서 고려해야할 사항들을 충전시술시와 근관치료시로 나누어서 각 시술 별로 간단히 살펴보조져 한다.

  • PDF

Alginate와 Agar-Agar에 의한 연합인상법의 촌법정도에 관한 임상적 연구 (A Clinical Study on the Dimensional Accuracy of the Combined Impression (Alginate & Agar-Agar))

  • 하주태;이정만;최부병
    • 대한치과의사협회지
    • /
    • 제17권9호통권124호
    • /
    • pp.701-708
    • /
    • 1979
  • A series of combined impressions, alginate impressions and rubber base impression made of the lower left quadrant of one subject having a cast gold crown with six reference marks on lower let 1st molar. the combined impressions of hydrocolloid were removed from the mouth at 2.5min, after the insertion of the tray. The alginate impressions were removed from the mouth at 2min, after the insertion of the tray. The rubber base impressions were removed from the mouth at 10min. The effect on the accuracy of the combined impressions, alginate impressions and rubber base impressions was obtained following results by comparing the distances between the reference marks in indirect stone cast with the standard measurements of the cast gold crown prior to cementation. The findings through this study could be summarized as follows; 1. The accuracy of combined impression was superior to that of alginate impression, but it was inferior to that of rubber base impressions. 2. Combined impressions produced a little distortion of the mesio-distal length, alginate impressions produced the largest distortion, ut rubber base impressions produced the least distortion.

  • PDF

A three-dimensional finite element analysis of the relationship between masticatory performance and skeletal malocclusion

  • Park, Jung-Chul;Shin, Hyun-Seung;Cha, Jung-Yul;Park, Jong-Tae
    • Journal of Periodontal and Implant Science
    • /
    • 제45권1호
    • /
    • pp.8-13
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the transfer of different occlusal forces in various skeletal malocclusions using finite element analysis (FEA). Methods: Three representative human cone-beam computed tomography (CBCT) images of three skeletal malocclusions were obtained from the Department of Orthodontics, Yonsei University Dental Hospital, Seoul, South Korea. The CBCT scans were read into the visualization software after separating bones and muscles by uploading the CBCT images into Mimics (Materialise). Two separate three-dimensional (3D) files were exported to visualize the solid morphology of skeletal outlines without considering the inner structures. Individual dental impressions were taken and stone models were scanned with a 3D scanner. These images were integrated and occlusal motions were simulated. Displacement and Von Mises stress were measured at the nodes of the FEA models. The displacement and stress distribution were analyzed. FEA was performed to obtain the 3D deformation of the mandibles under loads of 100, 150, 200, and 225 kg. Results: The distortion in all three skeletal malocclusions was comparable. Greater forces resulted in observing more distortion in FEA. Conclusions: Further studies are warranted to fully evaluate the impact of skeletal malocclusion on masticatory performance using information on muscle attachment and 3D temporomandibular joint movements.

Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography

  • Kim, Dong-Yeon;Kim, Chong-Myeong;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.176-181
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental ${\mu}-SLA$ system. MATERIALS AND METHODS. Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope ($160{\times}$) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (${\alpha}=.05$). RESULTS. The mean (${\pm}$ standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: $81.5{\pm}73.8$, $98.1{\pm}76.1$, $87.1{\pm}44.8$, and $146.8{\pm}78.7{\mu}m$ in the LW group; $76.8{\pm}48.0$, $141.7{\pm}57.1$, $80.7{\pm}47.5$, and $194.69{\pm}63.8{\mu}m$ in the NC group; and $124.2{\pm}52.0$, $199.5{\pm}71.0$, $67.1{\pm}37.6$, and $244.5{\pm}58.9{\mu}m$ in the CC group. CONCLUSION. The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice.

기계적 표면 처리된 TITANIUM PLASMA SPRAYED IMPLANT에 대한 치은섬유아세포전개양상의 형태학적 관찰 (THE MORPHOLOGICAL OBSERVATION OF HUMAN GINGIVAL FIBROBLASTS ATTACHMENT AND SPREADING ON THE MECHANICAL TREATED TITANIUM PLASMA SPRAYED IMPLANT SURFACE)

  • 황연희;이재목;서조영
    • Journal of Periodontal and Implant Science
    • /
    • 제25권3호
    • /
    • pp.741-755
    • /
    • 1995
  • 구강내 매식된 임프란트가 과도한 교합력이나 염증등의 이유로 구강내로 노출되었을 때 세균독소에 이완된 면을 제거하고 평활한 면을 형성하여 주위의 연조직, 경조직에 적합한 상태로 만들어 건강한 상태로 구강내에 유지하기 위해서 임프란트 매식체 표면을 기계적인 표면처리방법으로 처치하여 이러한 방법이 임프란트 표면성분, 치은섬유아세포의 전개양상에 미치는 영향을 알아보고자 본 실험을 실행하였다. IMZ사에서 제작한 직경 10mm, 높이 2mm의 원판 타이타늄을 이용하여 피막되지 않은 타이타늄면과 TPS면을 대조군으로 하고 기계적인 표면처리방법인 low speed stone bur처치면을 실험군으로 설정한 후 EDX로 타이타늄 표면성분을 분석하였고 주사전자현미경으로 치은섬유아세포의 전개양상을 관찰하였다. EDX에 의한 타이타늄 표면성분분석 결과 모든 실험군에서 titanium peak, 소량의 aluminum이 나타났으며 그외의 성분은 나타나지 않았다. 치은섬유아세포의 전개양상에 대한 주사전자현미경 관찰결과 평활한 타이타늄면에서 접종 30분 후 세사상돌기와 박판엽상으로 확장된 세포가 많이 관찰되며 6시간 후 신장된 치은섬유아세포가 시편에 밀착된 양상을 보였고 24시간 후 치은섬유아세포는 시편의 모든 면을 피개하며 가공시의 평행한 선을 따라 방향성을 띄었다. TPS가 잔존한 stone처치군에서 세포 접종 30분 후 세사상돌기가 적게 관찰되어 평활한 타이타늄면에 비해 초기부착이 늦은 것을 알 수 있었고 6, 24시간후 치은섬유아세포는 거친면으로 인해 시편에 밀착되지 못한 양상을 보였으나 평활한 타이타늄면과 연결되며 시편의 모든면을 피개하였다. TPS군에서 치은섬유아세포는 세포 접종 30분후 세사상돌기를 거의 찾아 볼 수 없어 초기부착이 다른군에 비해 늦으며 세포배양 6, 24시간후에도 시편에 밀착되지 못하고 박판상돌기가 가늘고 길게 돌출되어 여러면에 부착된 양상을 보였으며 세포가 부착되지 않은 TPS면이 관찰되었다.

  • PDF

수종의 조직 양화재의 침수시간과 분액비에 따른 표면 거칠기의 변화 (Changes of the surface roughness depending on immersion time and powder/liquid ratio of various tissue conditioners)

  • 김경수;문홍석;심준성;정문규
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.108-118
    • /
    • 2009
  • 연구목적: 1961년 Chase에 의해 처음 소개된 기능 인상법(functional impression technique)은 기존 의치에 이장된 조직 양화재(tissue conditioner)를 이용하여 실제 기능 운동 하에서 동적인 지지 조직의 인상과 기능적이며 생리적인 의치 변연부의 형태와 길이를 기록하는 술식이다. 조직 양화재가 기능 인상법의 재료로 사용되기 위해서는 체적 안정성, 미세부 재현성, 흐름성 등의 특성과 함께 치과용 석고와의 적합성(compatibility)을 고려하여야 한다. 하지만 기능 인상법 재료로 조직 양화재를 사용할 경우 구강내 환경 속에서 시간이 지남에 따라 석고 표면 거칠기에는 어떠한 영향을 미칠지 또한 그에 따라 석고 표면의 변화를 고려하여 어느 정도 기간 동안 구강 내에 유지하는 것이 좋을지에 대한 연구는 거의 없는 상황이다. 이에 본 연구는 조직 양화재를 기능 인상법의 재료로서 사용할 경우, 조직 양화재의 종류와 분액비, 침수시간이 치과용 석고 표면 거칠기에 어떠한 영향을 주는지 알아보고자 하였다. 연구 재료 및 방법: 임상적으로 많이 쓰이는 3종의 조직 양화재(Coe-Comfort, Visco-Gel, Soft-Liner)로 제조사에서 추천하는 분액비(P/L ratio)를 기준으로 표준 분액비에 따라 혼합한 군(R), 분말의 양을 20% 많이 혼합한 군(M), 분말의 양을 20% 적게 혼합한 군(L)으로 나누어 조직 양화재를 혼합하여 직경 20 mm, 두께 2 mm의 시편을 제작하였다. 각 조직 양화재 시편들을 다시 인공 타액 속의 침수시간(0시간, 1일, 3일, 5일, 7일)에 따라 5개의 군으로 나눈 뒤 인공 타액에 완전히 담구어 $37^{\circ}C$에서 보관하였다. 정해진 침수시간이 경과한 시편을 꺼내서 초경석고를 부어 석고 시편을 제작한 뒤 조직 양화재와 접해있던 석고 시편 표면의 거칠기를 접촉식 표면 조도기(Surfcoder SEF-30D, Kosaka laboratory Ltd., Tokyo, Japan)로 측정하여 다음과 같은 연구 결과를 얻었다. 결과 및 결론: 1. 조직 양화재로 부터 만들어진 석고 모형의 표면 거칠기에 주된 영향을 미치는 요인은 기능 인상을 채득하기 위해 구강 내에 조직 양화재를 위치시키는 기간이었고, 그 외에 조직 양화재의 종류와 분액비도 통계학적으로 유의한 영향을 미치는 요인이었다. 2. 3가지 P/L ratio 실험 조건 모두에서 Visco-Gel과 Soft-Liner 간에는 석고 모형의 표면 거칠기값이 침수시간이 변함에 따라 통계학적으로 유의성 있는 차이를 보이지 않았지만, Coe-Comfort의 경우에는 침수시간이 변함에 따라 Soft-Liner와 Visco-Gel보다 석고 모형의 표면 거칠기값이 통계학적으로 유의성 있게 더 큰 값을 보였다. 3. 3종의 실험 대상 조직 양화재 모두에서 R(recommended)와 M(more) group 간에는 석고 모형의 표면 거칠기값이 침수시간이 변함에 따라 통계학적으로 유의성 있는 차이를 보이지 않았지만, L(less) group의 경우에는 침수시간이 변함에 따라 R과 M group보다 석고 모형의 표면 거칠기값이 통계학적으로 유의성 있게 더 큰 값을 보였다. 이러한 연구 결과로부터 석고 모형의 표면 거칠기에는 구강 내에서의 시간이 가장 큰 영향을 나타내며, 조직 양화재의 종류와 분액비도 영향을 미칠 수 있기 때문에 술자가 기능 인상 채득 시에 적절한 구강 내 적용시간에 대해서 잘 이해하고 있고, 기능 인상에 적합한 조직 양화재를 선별할 수 있다면 조직 양화재를 이용하여 유용하게 기능 인상을 채득할 수 있을 것이다.

치과 진료실에서 3D 프린트의 활용 (Application of 3D printer in dental clinic)

  • 김현동
    • 대한심미치과학회지
    • /
    • 제27권2호
    • /
    • pp.82-96
    • /
    • 2018
  • 3D 프린팅은 삼차원 이미지 정보를 이용하여 레이어로 분할한 후 선택한 소재를 적층하여 가공하는 방법을 말한다. 소재를 적층하는 방법에 따라 다양한 종류의 3D 프린팅이 존재하는데 최근 치과분야에서는 SLA방식과 DLP방식으로 광원을 이용한 경화를 통해 적층 가공하는 3D 프린팅이 널리 보급되어 사용되고 있다. 전악 범위의 3D프린팅 치과용 모델은 전통적인 인상 채득으로 제작된 스톤모델보다는 다소 정확성이 부족한 것으로 보고되었으나, 같은 STL파일을 이용하여 4분악 범위를 3D 프린팅한 모델은 밀링 방법으로 가공한 모델보다 정확하였다. 디자인 소프트웨어의 활용도에 따라 보철치료의 진단, 임시 보철물의 제작, 의치의 제작이 가능하였다. 교정에서는 투명 교정 모델과 브라켓 간접 부착을 위한 트레이 제작이 가능하였다. 임플란트 수술에 있어서 CT를 기반으로 한 정확한 위치에 임플란트를 식립하는 가이드 제작에 활용하고 있다. 출력 방식의 발전으로 인하여 3D 프린터의 출력시간이 계속적으로 단축되고 있으며, 이로 인해 치과 진료실 내에서 3D 프린터가 기존의 전통적인 가공 방법을 대체할 수 있을 것으로 기대한다.