• Title/Summary/Keyword: dental restoration failure

Search Result 63, Processing Time 0.022 seconds

Dental application of glass-ceramic materials for aesthetic restoration (심미수복을 위한 글라스-세라믹 재료의 치과 응용)

  • Bae, Tae Sung
    • The Journal of the Korean dental association
    • /
    • v.58 no.7
    • /
    • pp.435-442
    • /
    • 2020
  • Porcelain is the first ceramic material to be introduced into dentistry. Porcelain jacket crown was introduced by Dr. Charles H Land in 1886, which was an excellent aesthetic dental restoration but has not been widely used due to high firing shrinkage and low tensile strength. Then metal-ceramic system, which combines the esthetic properties of ceramics and the mechanical properties of metals, was introduced and nowadays it is still used in dental clinical field. However, the metal-ceramic system has shown some problems, such as increased lightness by reflection of light at opaque layer, shadow beneath the gingival line due to the block-out of light by metal coping, exposure of metal in margin part, bond failure between metal and porcelain, oxidation of metal coping during firing the porcelain, etc. Recently, along with the advance of fabrication methods of dental ceramics, the all-ceramic restorations with high esthetic and mechanical properties has increased and gradually replaced metal-ceramic restorations. Especially, CAD/CAM technology has opened a new era in fabricating the dental ceramic restorations. This overview will take a look at the past, present and future possibility of the dental ceramic materials.

  • PDF

Morphological Measurements of Anatomic Landmarks in Human Mandibular Molar Pulp Chambers - An in vivo Study

  • Lokade, Joyti;Rawlani, Shivlal;Baheti, Rakhi (Chandak);Roy, Shelly;Chandak, Manoj;Lohe, Vidya
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: Exact knowledge of the location and dimension of the pulp chamber help to maintain the pulp healthy during operative procedure and also reduces the risk of perforation of pulp chamber during root canal treatment. This in-vivo study was carried out to measure critical morphology of pulp chamber of mandibular molar using intra-oral periapical radiograph. Materials and Methods: Mandibular molar teeth of 56 patients were evaluated. The mandibular molar teeth whose pulp chamber was not violated by caries, restoration, fracture crown and those having closed apex were included in the study. The intraoral periapical radiographs were taken with paralleling angle technique using radio-opaque grid with 1 mm space. This grid was placed directly on the film. Results: In 94% of the mandibular first molars specimens the pulp chamber ceiling was at the level of the cemento-enamel junction. The measurements showing the lowest percentage variance were buccal cusp to furcation (approximately 11%) and buccal cusp to pulp chamber ceiling (approximately 15%). The distance from the cusp tip to pulp chamber ceiling height was approximately 6.0 mm, the distance from the pulpal floor to the furcation was approximately 3.0 mm, and the average height of a pulp chamber was 1.5 to 2.0 mm. Conclusion: The exact knowledge of distances of pulp chamber from various anatomical landmarks helps in proper assessment of root canals and ultimately avoids the failure of root canal treatment.

Implant success rates in full-arch rehabilitations supported by upright and tilted implants: a retrospective investigation with up to five years of follow-up

  • Francetti, Luca;Rodolfi, Andrea;Barbaro, Bruno;Taschieri, Silvio;Cavalli, Nicolo;Corbella, Stefano
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.6
    • /
    • pp.210-215
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to investigate the cumulative success rate, the implant survival rate, and the occurrence of biological complications in implants supporting full-arch immediately loaded rehabilitations supported by upright and tilted implants. Methods: The clinical records and periapical radiographs of patients who attended follow-up visits were collected, and information was recorded regarding marginal bone loss resorption, the occurrence of peri-implant infectious diseases, and the implant survival rate. Implants were classified as successful or not successful according to two distinct classifications for implant success. Results: A total of 53 maxillary and mandibular restorations including 212 implants were analysed, of which 56 implants were studied over the full five-year follow-up period. After five years, the cumulative success rate was 76.04% according to the Misch classification and 56.34% according to the Albrektsson classification. The cumulative implant survival rate was 100%, although one implant was found to be affected by peri-implantitis at the second follow-up visit. Conclusions: The cumulative success rate of the implants dropped over time, corresponding to the progression of marginal bone resorption. The prevalence of peri-implantitis was very low, and the implant survival rate was not found to be related to the cumulative success rate.

A multidisciplinary approach to restore crown-root fractured maxillary central incisors: orthodontic extrusion and surgical extrusion (치관-치근 파절이 발생한 상악 중절치를 수복하기 위한 다각적 접근법: 교정적 정출술과 외과적 정출술)

  • Kwon, Eun-Young;Kim, So-Yeun;Jung, Kyoung-Hwa;Choi, Youn-Kyung;Kim, Hyun-Joo;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.262-271
    • /
    • 2020
  • To restore a tooth with a fracture line extending below the marginal bone level, a surgical crown lengthening procedure accompanied by ostectomy could be considered to expose the fracture line and reestablish the biologic width. However, this procedure could lead to esthetic failure, especially in the anterior teeth. Therefore, orthodontic extrusion, which elevates the fracture line from within the alveolar socket without sacrificing the supporting bone and gingiva, is recommended. This technique allows for the proper placement of the crown on a sound tooth structure, with the reestablishment of the biologic width. Alternatively, surgical extrusion is an one-step procedure that is simpler and less time-consuming than orthodontic extrusion; placing and adjusting the orthodontic appliance does not require multiple visits. This study presents successful restoration in 2 cases with a crown-tooth root fracture of the maxillary central incisor treated using a multidisciplinary approach through orthodontic extrusion or surgical extrusion followed by successful restoration.

OCULOCUTANEOUS ALBINISM : A CASE REPORT (전신성 백색증(Oculocutaneous albinism) 환아의 증례 보고)

  • Choi, Ji-Eun;Choi, Nam-Ki;Kim, Seon-Mi;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.713-717
    • /
    • 2008
  • Albinism is a disease caused by partial or complete failure of melanin production in the skin, hair and eyes despite the presence of normal number, structure and distribution of melanocytes. Typical aspects are white-colored skin, blonde-brown hair, blue-brown irides and a prominent red reflex. Three main categories of albinism are oculocutaneous, ocular and localized albinism, and also they are divided into many subgroups. Therefore, appropriate treatment plan and dental direction would be differentiated according to them. This case report was about oral conditions and treatment of the oculocutaneous albinism patient with mental retardation who was refered due to developmental delay of teeth and treated with teeth extraction, restoration and space maintenance etc.

  • PDF

In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials

  • Choi, Yu-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.162-169
    • /
    • 2012
  • PURPOSE. Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques. MATERIALS AND METHODS. A 1.2 mm, $360^{\circ}$ chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely $X^{TM}$ Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (${\alpha}$= 0.05). Scanning electron microscope was used to investigate the fractured interface. RESULTS. Mean fracture load and standard deviation was $4263.8{\pm}1110.8$ N for Group LT, $5070.8{\pm}1016.4$ for Group HT and $6242.0{\pm}1759.5$ N for Group ST. The values of Group ST were significantly higher than those of the other groups. CONCLUSION. Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.

Effect of the restorative technique on load-bearing capacity, cusp deflection, and stress distribution of endodontically-treated premolars with MOD restoration

  • da Rocha, Daniel Maranha;Tribst, Joao Paulo Mendes;Ausiello, Pietro;Dal Piva, Amanda Maria de Oliveira;Rocha, Milena Cerqueira da;Di Nicolo, Rebeca;Borges, Alexandre Luiz Souto
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.33.1-33.12
    • /
    • 2019
  • Objectives: To evaluate the influence of the restorative technique on the mechanical response of endodontically-treated upper premolars with mesio-occluso-distal (MOD) cavity. Materials and Methods: Forty-eight premolars received MOD preparation (4 groups, n = 12) with different restorative techniques: glass ionomer cement + composite resin (the GIC group), a metallic post + composite resin (the MP group), a fiberglass post + composite resin (the FGP group), or no endodontic treatment + restoration with composite resin (the CR group). Cusp strain and load-bearing capacity were evaluated. One-way analysis of variance and the Tukey test were used with ${\alpha}=5%$. Finite element analysis (FEA) was used to calculate displacement and tensile stress for the teeth and restorations. Results: MP showed the highest cusp (p = 0.027) deflection ($24.28{\pm}5.09{\mu}m/{\mu}m$), followed by FGP ($20.61{\pm}5.05{\mu}m/{\mu}m$), CR ($17.62{\pm}7.00{\mu}m/{\mu}m$), and GIC ($17.62{\pm}7.00{\mu}m/{\mu}m$). For load-bearing, CR ($38.89{\pm}3.24N$) showed the highest, followed by GIC ($37.51{\pm}6.69N$), FGP ($29.80{\pm}10.03N$), and MP ($18.41{\pm}4.15N$) (p = 0.001) value. FEA showed similar behavior in the restorations in all groups, while MP showed the highest stress concentration in the tooth and post. Conclusions: There is no mechanical advantage in using intraradicular posts for endodontically-treated premolars requiring MOD restoration. Filling the pulp chamber with GIC and restoring the tooth with only CR showed the most promising results for cusp deflection, failure load, and stress distribution.

IMMEDIATE PROVISIONALIZATION USING ONE-PIECE NARROW DIAMETER IMPLANTS FOR RESTORATION OF EDENTULOUS NARROW SPACES: CASE REPORTS (좁은 결손부위에 One-piece narrow diameter implant를 이용한 즉시보철: 증례보고)

  • Bae, Min-Su;Heo, Jeong-Uk;Park, Jun-Sub;Yea, Sun-Hae;An, Kyung-Mi;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.276-279
    • /
    • 2009
  • The aim of this case study was to report the clinical outcome of immediate provisionalization using one-piece narrow diameter (3.0mm) implants in missing maxillary lateral or mandibular incisors. The present study included 36 patients who were treated with 62 one-piece narrow diameter implants. After implant placement, immediate provisional restorations were delivered. All implants showed favorable osseointegration and after progressive loading from 3 months to 9 months (average of 5 months), final restorations were completed without failure in all cases. A survival rate of 100 % (62 of 62) was observed up to 23 months of observation (average of 12.6 months).

Stress analysis of non carious cervical lesion and cervical composite resin restoration (지상강좌 1 - 비우식성 치경부병소와 치경부 복합레진수복의 응력분석)

  • Park, Jeong-Kil
    • The Journal of the Korean dental association
    • /
    • v.48 no.4
    • /
    • pp.297-307
    • /
    • 2010
  • Noncarious cervical lesions(NCCLs) are characterized as structural defects found on the tooth surface of the cement-enamel junction. Loss of tooth structure through noncarious mechanisms may vary in etiology and clinical presentation for each individual but presently many clinician now classify this as tooth failure of abfraction due to the stress applied in the cervical area of the tooth under oral physiological and pathological loads. In the current study, we investigated the stress distribution of maxillary premolar with NCCL using simulated 3D finite element analysis. The results were as follows: 1. In the sound maxillary premolar, the stresses were highly concentrated at cervical enamel surface of the mesiobuccal line angle, asymmetrically. 2. Once the lesion has been formed, the highest stress concentration was observed around the apex of the wedge shaped lesion. 3. In four types of NCCL, the patterns of stress distribution were similar and the peak stress was observed at mesial corner and also stresses concentrated at lesion apex. 4. Lesion cavity modification of rounding apex, reduced stress of lesion apex. 5. When restoring the notch-shaped lesion, material with high elastic modulus worked well at the lesion apex and material with low elastic modulus worked well at the cervical cavosurface margin.

Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures

  • Shim, Hye Won;Yang, Byoung-Eun
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.423-430
    • /
    • 2015
  • PURPOSE. To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth $Ankylos^{(R)}$ implants. MATERIALS AND METHODS. This was a retrospective clinical study that analyzed 450 single $Ankylos^{(R)}$ implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. RESULTS. The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all P<.05). CONCLUSION. The $Ankylos^{(R)}$ implant is suitable for single-tooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.