• 제목/요약/키워드: dental resin composite

검색결과 521건 처리시간 0.029초

치아수복용 복합레진이 치수조직에 미치는 영향에 관한 실험적 연구 (Experimental Study on Pulp Reactions to Composite Resin)

  • 임성삼
    • 대한치과의사협회지
    • /
    • 제11권11호
    • /
    • pp.711-715
    • /
    • 1973
  • The author studied histopathologically on the pulpal response of Blendant, Blendant lined with Dycal, silicate cement and direct resin in dog's teeth. The results were as follows ; 1. Blendant induced pulpal irritations but the intensity of irritations were less severe than Silicate cement and Orient. 2. At the postoperative interval of 4 weeks, Silicate cement produced severe pulpal response but the severe response caused by Orient was subsided. 3. Blendant lined with Dycal showed only slight or moderate pulpal response.

  • PDF

Repair bond strength of resin composite to bilayer dental ceramics

  • Ataol, Ayse Seda;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.101-112
    • /
    • 2018
  • PURPOSE. The purpose of this study was to investigate the effect of various surface treatments (ST) on the shear bond strength of resin composite to three bilayer dental ceramics made by CAD/CAM and two veneering ceramics. MATERIALS AND METHODS. Three different bilayer dental ceramics and two different veneering ceramics were used (Group A: IPS e.max CAD+IPS e.max Ceram; Group B: IPS e.max ZirCAD+IPS e.max Ceram, Group C: Vita Suprinity+Vita VM11; Group D: IPS e.max Ceram; Group E: Vita VM11). All groups were divided into eight subgroups according to the ST. Then, all test specimens were repaired with a nano hybrid resin composite. Half of the test specimens were subjected to thermocycling procedure and the other half was stored in distilled water at $37^{\circ}C$. Shear bond strength tests for all test specimens were carried out with a universal testing machine. RESULTS. There were statistically significant differences among the tested surface treatments within the all tested fracture types (P<.005). HF etching showed higher bond strength values in Groups A, C, D, and E than the other tested ST. However, bonding durability of all the surface-treated groups were similar after thermocycling (P>.00125). CONCLUSION. This study revealed that HF etching for glass ceramics and sandblasting for zirconia ceramics were adequate for repair of all ceramic restorations. The effect of ceramic type exposed on the fracture area was not significant on the repair bond strength of resin composites to different ceramic types.

Effect of solution temperature on the mechanical properties of dual-cure resin cements

  • Kang, En-Sook;Jeon, Yeong-Chan;Jeong, Chang-Mo;Huh, Jung-Bo;Yun, Mi-Jung;Kwon, Yong-Hoon
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.133-139
    • /
    • 2013
  • PURPOSE. This study was to evaluate the effect of the solution temperature on the mechanical properties of dualcure resin cements. MATERIALS AND METHODS. For the study, five dual-cure resin cements were chosen and light cured. To evaluate the effect of temperature on the specimens, the light-cured specimens were immersed in deionized water at three different temperatures (4, 37 and $60^{\circ}C$) for 7 days. The control specimens were aged in a $37^{\circ}C$ dry and dark chamber for 24 hours. The mechanical properties of the light-cured specimens were evaluated using the Vickers hardness test, three-point bending test, and compression test, respectively. Both flexural and compressive properties were evaluated using a universal testing machine. The data were analyzed using a two way ANOVA with Tukey test to perform multiple comparisons (${\alpha}$=0.05). RESULTS. After immersion, the specimens showed significantly different microhardness, flexural, and compressive properties compared to the control case regardless of solution temperatures. Depending on the resin brand, the microhardness difference between the top and bottom surfaces ranged approximately 3.3-12.2%. Among the specimens, BisCem and Calibra showed the highest and lowest decrease of flexural strength, respectively. Also, Calibra and Multilink Automix showed the highest and lowest decrease of compressive strength, respectively compared to the control case. CONCLUSION. The examined dual-cure resin cements had compatible flexural and compressive properties with most methacrylate-based composite resins and the underlying dentin regardless of solution temperature. However, the effect of the solution temperature on the mechanical properties was not consistent and depended more on the resin brand.

유동성 복합레진의 마모저항성에 관한 연구 (A STUDY ON WEAR RESISTANCE OF FLOWABLE COMPOSITE RESINS)

  • 윤연희;김정욱;이상훈;한세현
    • 대한소아치과학회지
    • /
    • 제29권2호
    • /
    • pp.217-225
    • /
    • 2002
  • 시술시간을 줄이는데 유리한 재료인 유동성 복합레진을 유구치부에 사용하려고 고려할 때 중요한 물성 중 하나는 마모저항성이다. 이 연구의 목적은 유동성 복합레진의 마모저항성을 일반복합레진의 마모저항성과 비교하는 것이다. 실험에 사용된 유동성 복합레진으로 1군에서는 Arabesk flow (VOCO, Germany) 2군에서는 Tetric flow (Vivadent, Liechtenstein) 3군에서는 Aeliteflow (Bisco, U.S.A.), 4군에서는 Filtek flow (3M Dental Co, U.S.A)을 사용하였으며 대조군으로 사용한 5군의 복합레진은 Z100 (3M Dental Co, U.S.A)이었다. 시편들(n=10)은 두께 2mm, 지름 5mm의 원통모양으로 제작하여 마모시험 전 $37^{\circ}C$의 증류수에서 7일 동안 담가 놓았다. 제1소구치와 레진시편을 MTS 시스템에서 2Hz로 50,000회 접촉, 마모시켰다. 마모시험시 lateral excursion은 0.4mm, 교합력은 2-100N의 조건이었다. 마모시험후 마모된 부피, 최대마모깊이, 재료자체의 표면경도를 측정하였고 마모 되지 않은 표면과 마모가 일어난 표면을 주사전자현미경으로 관찰하였으며 다음과 같은 결과를 얻었다. 1. 마모된 부피는 3군에서 가장 적었고 4군에서 가장 많았으며 3군<1군<2군<5군<4군의 순서로 증가하였다. 2. 3군, 1군, 2군은 5군이나 4군에 비해 통계적으로 유의하게 마모부피가 적었다(p<0.05). 그러나, 3군, 1군, 2군 사이에서와 5군, 4군 사이에서는 각각 통계적으로 유의한 차이가 없었다. 3. 최대마모깊이는 1군에서 가장 낮았고, 4군에서 가장 깊었으며 1군<3군<5군<2군<4군의 순서로 증가 하였다. 4. 5군의 표면경도는 다른 유동성 복합레진군에 비해 통계적으로 유의하게 높았으나(p<0.05), 마모부피나 최대마모깊이와는 통계적으로 유의한 상관관계를 보이지 않았다. 5. 마모되지 않은 표면과 마모가 일어난 표면을 주사전자현미경으로 관찰한 결과, 유동성 복합레진군과 5군 사이에 마모양상이 다르게 나타나는 것을 볼 수 있었다.

  • PDF

2,2-비스[4-(2-하이드록시-3-메타크릴로일옥시프로폭시)페닐] 프로판 유도체와 스파이로 오쏘카보네이트가 포함된 치아 수복재의 특성 (Characteristics of Dental Restorative Composite Resins Prepared from 2,2-bis- [4- (2-hydroxy-3-rnethacryloyloxy propoxy) phenyl] propane Derivatives and Spiro Orthocarbonate)

  • 김용;이주연;박광용;김창근;김오영
    • 폴리머
    • /
    • 제28권5호
    • /
    • pp.426-432
    • /
    • 2004
  • 상업적으로 이용되는 고분자계 치과용 수복재의 문제점인 중합시 나타나는 부피 수축을 감소시키기 위해 (2,2-비스[4-(2-하이드록시-3-메타크릴로일옥시프로폭시)페닐] 프로판) (bis-GMA), 유도체인 (2,2-비스[3-메틸, 4-(2-하이드록시-3-메타크릴로일옥시프로폭시)페닐] 프로판) (DMBis-GMA)와 (2,2-비스[3,5-디메틸, 4-(2-하이드록시-3-메타크릴로일옥시프로폭시)페닐] 프로판) (TMBis-GMA)를 합성하고 이를 희석제, 스파이로 오쏘카보네이트, 무기 충진재와 혼합하여 새로운 고분자계 치과용 수복재를 제조하였다. Bis-GMA 유도체/Bis-GMA 유도체/희석제 혼합계들 중에서 Bis-GMA/TMBis-GMA/TEGDMA 계의 중합 수축률이 가장 작았다. 이혼합계에 스파이로 오쏘카보네이트를 첨가함으로써 중합 수축률은 더욱 감소하였다. 최소의 중합 수축률을 나타내는 레진 단량체 혼합물을 사용하여 치과용 수복재를 제조한 결과 중합 수축률은 $0.7\%$로 기존 수복재의 중합 수축률 $2.5\%$에 비해 크게 감소하였다. 또 수복재의 기계적 강도는 기존 소재와 비슷하였지만 중합이 완료되는데 필요한 시간은 지연되었다.

Wear of contemporary dental composite resin restorations: a literature review

  • Dimitrios Dionysopoulos;Olga Gerasimidou
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.18.1-18.13
    • /
    • 2021
  • Composite resins are the most commonly used dental restorative materials after minimally invasive dental procedures, and they offer an aesthetically pleasing appearance. An ideal composite restorative material should have wear properties similar to those of tooth tissues. Wear refers to the damaging, gradual loss or deformation of a material at solid surfaces. Depending on the mechanism of action, wear can be categorized as abrasive, adhesive, fatigue, or corrosive. Currently used composite resins cover a wide range of materials with diverse properties, offering dental clinicians multiple choices for anterior and posterior teeth. In order to improve the mechanical properties and the resistance to wear of composite materials, many types of monomers, silane coupling agents, and reinforcing fillers have been developed. Since resistance to wear is an important factor in determining the clinical success of composite resins, the purpose of this literature review was to define what constitutes wear. The discussion focuses on factors that contribute to the extent of wear as well as to the prevention of wear. Finally, the behavior of various types of existing composite materials such as nanohybrid, flowable, and computer-assisted design/computer-assisted manufacturing materials, was investigated, along with the factors that may cause or contribute to their wear.

Er:YAG 레이저를 활용한 와동형성시 컴포짓 결합강도 (Tensile Bond Strength of Composite Resin Treated with Er:YAG Laser)

  • 신민;지영덕;류성호;조진형
    • Journal of Oral Medicine and Pain
    • /
    • 제30권2호
    • /
    • pp.269-276
    • /
    • 2005
  • 재래의 고속핸드피스 bur를 이용한 와동 형성시 레진 접착력과 레이저를 사용한 와동형성시 접착력을 비교하여 레이저의 임상적용 여부를 평가하는 것이 본 연구의 목적이다. 총 96개 치아 표본의 법랑질 협면과 상아질 mid-coronal 부에 Er:YAG laser를 사용하여 조사하였다. 사전에 산부식을 시킨 군(48개)과 부식시키지 않은 군(48개)으로 구별하고 각각 flowable 접착시스템(Metafil Flo)과 자가중합 시스템(Clearfil FII New Bond)를 레진에 접착시켰다. 37$^{\circ}C$ 증류수에서 24시간동안 보관한 후 미세 결합강도(micro-tensile shear strength)를 만능시험기(universal testing machine)로 측정하여 다음과 같은 결과를 얻었다. 1. 법랑질과 상아질 모두 산부식 전처리를 한 경우에 산처리를 하지 않은 경우보다 결합강도가 높았고, 레이저 처리 표본에서도 마찬가지여서 레이저만으로 처리하는 것보다는 산부식 처리를 하는 것이 강도면에서 유리한 것으로 나타났다. 2. 법랑질의 경우 레이저 처치한 경우가 bur로 삭제한 경우보다 두 레진군 모두에서 결합강도가 낮았으나(P<0.05), 상아질의 경우에는 flowable 레진군에서는 두 군 간의 차이가 없었다. 3. 레이저 처치군내에서 상아질의 경우, 광중합 flowable 레진의 결합강도가 자가중합형 레진의 강도보다 높았으나, 법랑질에서는 차이가 없었다. 따라서 레이저를 활용하여 와동을 형성하는 것은 상아질까지 확대된 와동의 경우에 법랑질에 국한된 경우보다 결합강도면에서 유리하며, flowable레진을 사용하는 것이 자가중합형 레진보다 유리한 것으로 판단되었다.

유동성 복합 레진을 적용한 예방적 레진 수복물의 미세 누출 양상에 관한 비교 연구 (A COMPARATIVE STUDY ON THE MICROLEAKAGE OF PRVENTIVE RESIN RESTORATION USING FLOWABLE COMPOSITE RESIN)

  • 박헌정;김종수;김용기
    • 대한소아치과학회지
    • /
    • 제27권3호
    • /
    • pp.419-430
    • /
    • 2000
  • 성인에 비해 치료를 견별 수 있는 시간이 상대적으로 짧은 소아 환자에 있어 시술 시간은 치료 결과의 중요한 변수로 작용하게 된다. 최근 소개된 유동성 복합 레진을 예방적 레진 수복술에 사용하게 될 경우 전색재 도포 과정을 생략할 수 있어 시술 시간의 단축 편의성 등의 장점이 인정되나 미세누출 등에 관한 연구 결과는 미흡한 실정이다. 본 연구의 목적은 최근 소개된 유동성 복합 레진을 사용한 예방적 레진 수복물과 기존의 복합 레진과 전색재를 사용한 예방적 레진 수복물 간의 미세누출 및 기포발생 정도를 비교하고자 함이었다. 교합면이 건전한 상악 소구치 60개를 대상으로 고속용 1/2 round bur를 이용하여 교합면 열구를 따라 길이$3.0\times$$0.7\times$깊이2.0mm의 I급 와동을 형성하고 각 군 당 20개씩 무작위로 시편을 배분하고, 제조자의 지침에 따라 본딩재인 Scotchbond $Multipurpose^{TM}$(3M dental product, U.S.A.)를 적용하고 유동성 복합 레진 수복군인 I, II군에는 각각 $Revolution^{TM}$(Kerr, U.S.A.)과 Arabesk Flow(VOCO, Germany), 대조군인 III군(통상적 예방적 레진 수복군)에는 Restorative $Z-100^{TM}$(3M dental product, U.S.A.)과 $Concise^{TM}$(3M dental product, U.S.A.)를 제조자의 지시에 따라 충전, 적용하였다. 3,000회의 열 순환 및 색소 침투 후 시편을 절단하여 컴퓨터에 영상을 입력하고 색소의 침투 길이 및 침투 비율을 계산하고 미세누출 평가 기준을 이용하여 각 시편에 대한 미세누출 정도를 평가하였다. 또한, 각 군별로 특징적으로 나타난 기포의 발생 양상을 별도의 평가기준에 따라 평가하였다. 미세누출은 수복재와 법랑질의 계면부에 국한되어 관찰되었고, 와동 내부까지 침투된 경우는 없었으며, 유동성 복합레진 수복군(I, II군)이 기존의 예방적 레진 수복군(III군)에 비해 낮은 미세 누출 정도를 나타냈다(p<0.05). 미세누출 결과 외에, 대부분의 충전물 내에서 다양한 형태의 기포가 발견되었으며, I, II군 표본에서 III군에 비해 크기가 큰 기포가 더욱 많이 관찰되었다.

  • PDF

고무상입자가 치과용 복합레진의 물리적 성질에 미치는 영향 (EFFECT OF CORE-SHELL PARTICLES ON PHYSICAL PROPERTIES OF DENTAL COMPOSITES)

  • 최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.690-700
    • /
    • 1998
  • Rubber-toughened particles which are used in the field of chemical engineering are used to increase the fracture toughness of thermoset resin. The application of Core-Shell particles, one of rubber-toughened particles, as a filler for dental composite or restoration have not been examined. The purpose of this study was to evaluate possible use of Core-Shell particles for dental composite, and the hypothesis was that additional toughening mechanisms are activated by the addition of Core-Shell particles. After blending 50vol% quartz with Bis-GMA/TEGDMA resin matrix, the experimental resins were made by the addition of Core-Shell particles with varied content level as 0, 2.5, 5, 7.5, 10, 12.5, 15, and 20wt%. Fracture toughness was determined on three-point bending specimen with single-edge notch according to ASTM-E 399. Also, flexural properties, that is, strength and modulus were measured by three-point bending testing. Fractogragh of fracture toughness specimen was observed using SEM (JEOL 6400 SEM, MA). The following results from this study were obtained ; 1. Fracture toughness of composite resin added 2.5wt% Core-Shell particles was significantly higher than control group ($p{\leq}0.05$). 2. Flexural properties were decreased with increasing Core-Shell particle content, which showed a correlation statistically ($p{\leq}0.05$). 3. A toughening mechanism such as lamination and microcrack was observed in specimen determined high fracture toughness. 4. The dispersion of Core-Shell itself and quartz filler particles was limited present high content of Core-Shell particles, which decreased a resulting mechanical properties of composites. These results suggest that adequate Core-Shell particles can be used to enhance mechanical properties included toughening for dental composites.

  • PDF

치과용 접착제(Dental adhesive)를 사용한 제5급 복합레진수복물의 변연누출에 관한 실험적 연구 (IN VITRO STUDY ON THE MARGINAL LEAKAGE OF THE CLASS V COMPOSITE RESTORATION WITH DENTAL ADHESIVE)

  • 정근철;박동수;이찬영;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.135-144
    • /
    • 1984
  • This study was undertaken to evaluate the degree of the marginal leakage of composite restoration with 3 brands of dental adhesives by means of the dye penetration at the enamel and dentinal margins. 150 cavities of class V were prepared on the buccal and lingual surfaces of 75 extracted anterior and premolar teeth, which were devided into 3 groups. The cavities were filled with composite resin, Silar$^{(R)}$ (3M) and Heliosit$^{(R)}$ (Vivadent) after application of the dental adhesives, specifically Scotchbond$^{(R)}$ (3M) which is essentially composed with halophosphorus ester of Bis-GMA, Dentin Adhesit$^{(R)}$ (Vivadent) which is polyurethane resin, and Enamel Bond$^{(R)}$ (3M) which is a product of Bis-GMA with low viscosity at internal surfaces and margins of the cavities. All specimens were immersed in $37^{\circ}C$, 0.5% methylene blue solution for 24 hours after thermocycling at $4^{\circ}C$ and $60^{\circ}C$, embedded in acrylic resin, and sectioned with diamond disk into two parts. The sectioned specimens observed with the light microscope. The following results were obtained: 1. The group filled with Scotchbond$^{(R)}$-Silar$^{(R)}$ the other two groups at the enamel margins. 2. No significant difference in the degree of the marginal leakage had appeared between Dentin Adhesit$^{(R)}$-Heliosit$^{(R)}$ group an d Enamel Bond$^{(R)}$-Silar$^{(R)}$ group at the enamel margins. 3. Severe marginal leakage with penetration of dye to the floor of cavity had appeared from the all three groups and no significant difference in the degree of marginal leakage existed between the three groups at the dentinal margins.

  • PDF