• Title/Summary/Keyword: dental resin

Search Result 1,263, Processing Time 0.025 seconds

3 keys for successive direct esthetic restoration (성공적 직접 심미 수복을 위한 3가지 열쇠)

  • Cho, Sang Ho
    • The Journal of the Korean dental association
    • /
    • v.54 no.1
    • /
    • pp.16-20
    • /
    • 2016
  • There is a difficulty for many practioner in anterior direct restroation with composit resin. Because its result is various according to patient, a practioner have a fear about that unpromisable result. Moreover in esthetic region, there is difference in satisfaction by patient character. That is one of difficulty in this practice. But if we make a manual for parctice it will be easier. So I will summarize the process and things to note in direct anterior composite resin restoration.

  • PDF

Evaluation of the physical properties and antibacterial effects on Candida albicans of denture base resin containing silver sulfadiazine (실버 설파다이아진이 첨가된 의치상용 레진의 Candida albicans에 대한 항균평가 및 물성 평가)

  • Yu-Ri Choi;Min-Kyung Kang
    • Journal of Korean society of Dental Hygiene
    • /
    • v.23 no.6
    • /
    • pp.459-466
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the physical properties and antibacterial activity of denture base resin with added silver sulfadiazine. Methods: Specimens were made from self-curing denture base resin and silver sulfadiazine as an inorganic antibacterial agent. For physical evaluation of the specimens, surface roughness, surface hardness, and contact angle were measured. Bacterial growth was assessed by optical densityat 600 nm (OD600) and colony forming units (CFU) measurements to confirm antibacterial activity. Results: There was no significant difference in surface roughness, surface hardness, and contact angle in the experimental group containing silver sulfadiazine compared to the control group. In contrast, the experimental group showed a significant decrease in antibacterial activity compared to the control group in terms of OD value. Analysis of CFU confirmed a significant decrease in colonies in the experimental group compared to the control group. Conclusions: Denture base resin containing silver sulfadiazine, an inorganic antibacterial agent, exhibited enhanced antibacterial activity without physical changes. In conclusion, the use of denture base resin containing inorganic antibacterial agents may be expected in the future.

Effect of phytic acid as an endodontic chelator on resin adhesion to sodium hypochlorite-treated dentin

  • Mohannad Nassar;Noriko Hiraishi;Md. Sofiqul Islam;Maria JRH. Romero;Masayuki Otsuki;Junji Tagami
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.44.1-44.9
    • /
    • 2020
  • Objectives: Phytic acid (IP6), a naturally occurring agent, has been previously reported as a potential alternative to ethylenediaminetetraacetic acid (EDTA). However, its effect on adhesion to sodium hypochlorite (NaOCl)-treated dentin and its interactions with NaOCl have not been previously reported. Thus, in this study, the effects of IP6 on resin adhesion to NaOCl-treated dentin and the failure mode were investigated and the interactions between the used agents were analyzed. Materials and Methods: Micro-tensile bond strength (µTBS) testing was performed until failure on dentin treated with either distilled water (control), 5% NaOCl, or 5% NaOCl followed with chelators: 17% EDTA for 1 minute or 1% IP6 for 30 seconds or 1 minute. The failed specimens were assessed under a scanning electron microscope. The reaction of NaOCl with EDTA or IP6 was analyzed in terms of temperature, pH, effervescence, and chlorine odor, and the effects of the resulting mixtures on the color of a stained paper were recorded. Results: The µTBS values of the control and NaOCl with chelator groups were not significantly different, but were all significantly higher than that of the group treated with NaOCl only. In the failure analysis, a distinctive feature was the presence of resin tags in samples conditioned with IP6 after treatment with NaOCl. The reaction of 1% IP6 with 5% NaOCl was less aggressive than the reaction of the latter with 17% EDTA. Conclusions: IP6 reversed the adverse effects of NaOCl on resin-dentin adhesion without the chlorine-depleting effect of EDTA.

Behaviors-Based Safety Management of Dental Professionals on Dental Amalgam and Resin (치과용 아말감과 레진에 대한 치과종사자의 안전성에 대한 관리행동 실태)

  • Yoon, Sung-Uk;Nam, In-Suk
    • Journal of dental hygiene science
    • /
    • v.13 no.1
    • /
    • pp.97-104
    • /
    • 2013
  • This study investigated the safety management behavior of dental professionals to minimize exposure to harmful elements of amalgam and resin. As for the use of amalgam and resin, 85.8% of them used amalgam. 100% of used composite resin 100%. 97.8% used acryl resin, and 95.7% used tray resin. 95.2% and 36.5% of them were aware of the harm of amalgam and resin respectively. When using resin, their safety management behavior score was 1.99 on average, and the lowest score was 2.50 on average for 'ventilate the indoor air when handling resin'. Their average score of the safety management behavior was 1.83 when using amalgam. The lowest score was 2.89 on average for 'use the rubber dam for patients when handling amalgam'. As a result of the safety management behavior based on general characteristics, all characteristics were significant with regard to amalgam, and my position at work and work experience were significant with regard to resin (p<0.05). The correlation between the safety management behavior and general characteristics was analyzed when dental amalgam and resin are used. Amalgam was statistically correlated with academic background (p<0.05) and position at work (p<0.05), whereas resin was statistically significantly correlated with age (p<0.05) and position at work (p<0.05). Accordingly, education about the harm of dental materials must be continuously provided for dental professionals when they handle dental materials so that safety management behavior will be conducted correctly, and active efforts to protect the health of dental professionals from harmful chemicals must be made.

A newly-designed method to measure liner polymerization shrinkage

  • Ikejima, Iwao;Matsuzawa, Norihiko;Momol, Yasko;Kohno, Atsushi
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.604-604
    • /
    • 2003
  • I. Objectives Newly-designed method was evaluated to measure the linear polymerization shrinkage of light-cured resin composites. II. Materials and Methods A resin composite(Clearfil AP-X, Kuraray, Japan) was filled into a vinyl-polysiloxan mold(1 to 8mm-depth, and 7mm-diameter). As indicators, 4 beads(Retention Beads 2 SS, GC, Japan;particle size $200{\;}\mu\textrm{m}$) were placed diagonally on the resin surface of a mold. The coordinates (x, y, z, pasition) of each indicator were measrued by a measuring-microscope after which the resin surface was irradiated by a curing-light source(Optilux 500, Demetron/Kerr, USA) for 40 sec. After 20 sec the coordinates were again measured.(omitted)

  • PDF

Characterization of Dental Resin Cement Containing Graphene Oxide

  • Kim, Duck-Hyun;Seok, Jae-Wuk;Sung, A-Young
    • Journal of Integrative Natural Science
    • /
    • v.12 no.2
    • /
    • pp.29-34
    • /
    • 2019
  • In dental resin cement studies, viscosity is also an important factor in the adhesion of tooth defects and implants. This study used BisGMA and HPMA as the main ingredients, triethylene glycol dimethacrylate (TEGDMA) as a diluent, and benzoyl peroxide (BPO) as a photoinitiator. The physical properties of graphene oxide used as an additive for functionality were evaluated, and its use as a dental resin cement material was investigated.The rupture strength has the tendency to increase along with the increase of the ratio of graphene oxide that was added, which seemed to reflect the effect of the high strength property of graphene oxide. The flexural strength also has the tendency to increase when about 0.5% of graphene oxide was added the same as the increase of rupture strength.When graphene oxide was added, according to viscosity use, the utilization as high-quality dental resin cements will increase.

Effect of artificial aging on mechanical and physical properties of CAD-CAM PMMA resins for occlusal splints

  • Julia Correa Raffaini;Eduardo Jose Soares;Rebeca Franco de Lima Oliveira;Rocio Geng Vivanco;Ayodele Alves Amorim;Ana Lucia Caetano Pereira;Fernanda Carvalho Panzeri Pires-de-Souza
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.227-237
    • /
    • 2023
  • PURPOSE. This study aimed to assess and compare the color stability, flexural strength (FS), and surface roughness of occlusal splints fabricated from heat-cured acrylic resin, milled polymethyl methacrylate (PMMA)-based resin, and 3D-printed (PMMA) based-resin. MATERIALS AND METHODS. Samples of each type of resin were obtained, and baseline measurements of color and surface roughness were recorded. The specimens were divided into three groups (n = 10) and subjected to distinct aging protocols: thermomechanical cycling (TMC), simulated brushing (SB), and control (without aging). Final assessments of color and surface roughness and three-point bending test (ODM100; Odeme) were conducted, and data were statistically analyzed (2-way ANOVA, Tukey, P <.05). RESULTS. Across all resin types, the most significant increase in surface roughness (Ra) was observed after TMC (P < .05), with the 3D-printed resin exhibiting the lowest Ra (P < .05). After brushing, milled resin displayed the highest Ra (P < .05) and greater color alteration (∆E00) compared to 3D-printed resin. The most substantial ∆E00 was recorded after brushing for all resins, except for heat-cured resin subjected to TMC. Regardless of aging, milled resin exhibited the highest FS (P < .05), except when compared to 3D-printed resin subjected to TMC. Heat-cured resin exposed to TMC demonstrated the lowest FS, different (P < .05) from the control. Under control conditions, milled resin exhibited the highest FS, different (P < .05) from the brushed group. 3D-printed resin subjected to TMC displayed the highest FS (P < .05). CONCLUSION. Among the tested resins, 3D-printed resin demonstrated superior longevity, characterized by minimal surface roughness and color alterations. Aging had a negligible impact on its mechanical properties.

Comparison of bond strength between denture base resin and reline resin (의치상 레진과 이장 레진 간의 결합강도 비교)

  • Geum, Young-Hee;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.39 no.3
    • /
    • pp.161-167
    • /
    • 2017
  • Purpose: We compare the bond strength of heat-cured PMMA of Lucitone 199 and QC-20 and Tokuyama Rebase Resin of self-cured resin, which are widely used and well accepted in clinical practice. In order to test the mechanical bonding and chemical bonding, we will compare the bond strength between EstheShot Bright, Smiletone, Repair and Rebase resins. Methods: The denture base resin used in this study was PMMA heat-cured QC-20 and Lucitone 199, polyamide resin EstheShot Bright, Smiletone. And Two types of self-curing Rapid Repair and Tokuyama Rebase were used as resection resins. To measure the bond strength, the denture specimens were fabricated in the size of $10{\times}64{\times}3.5mm$ as instructed by the manufacturer. A surface treatment agent was applied to the cut surfaces of each denture specimen, and the specimens were placed in a preformed silicone mold, and autoclaved excimer resins were prepared. The bending strength of the fabricated specimens was measured using a universal testing machine (STM-5, United Calibration Co., U.S.A.) to measure the three-point bending strength. Results: In both polycarbonate and polyacetal resin, a special resin surface treatment agent showed higher bonding strength than the resin surface treatment agent(p<0.05). Regardless of the type of surface treatment, polycarbonate showed higher bond strength than polyacetal resin(p<0.05). Conclusion: It is considered desirable to use a special surface treating agent for the thermoplastic denture base resin such as polycarbonate and polyacetal resin.

Photopolymerization efficiency of dental resin composites with new mixed photosensitizers (새로운 혼합형 광증감제를 사용한 치과용 복합수지의 중합효율에 관한 연구)

  • Sun, Gum-Ju;Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.49-58
    • /
    • 2004
  • Two diketones, 1-phenyl-1,2-propanedione(PD) and 2,3-butanedione (BD) were investigated as new visible light photosensitizers for a dental resin composite of bis-GMA in order to improve photopolymerization effect. And the photopolymerization efficiency of mixed photosensitizers, PD-CQ and DA-CQ, was studied. Photopolymerization effect of photosensitizers were compared with that of camphorquinone(CQ), the most widely used photosensitizer. The photopolymerization efficiency of bis-GMA containing the photosensitizer increased with irradiation time. The increase was in the order: BD < CQ < PD. The photopolymerization efficiency of this mixture was not so efficient as CQ or PD.

  • PDF

A Study on the Direct Casting of Photo-polymer (포토 폴리머의 직접 주조에 관한 연구)

  • Kim, Woo-Soon;Kim, Dong-Hyun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.127-133
    • /
    • 2006
  • Rapid prototyping technologies have been widely used to reduce the development cost of new products. Manufacturing industries are nowadays characterized by the flexibility and complexity of products. This to due to the rapid development of manufacturing technology and diverse needs of customers. In this paper, the best homing out and casting condition for getting casting product of resin pattern(photopolymer) have been examined experimentally. In generally, the burning out and casting conditions have effect on the casting products. Using the direct casting. we directly Producted the Jewelry. And in this paper, we used only gypsum. Many study of casting for resin have been used to dental investment. A dental investment is good for resin casting. but dental investment is too hard and not useful on the jewelry casting. Therefore we need to find the way of resin casting by gypsum.