• Title/Summary/Keyword: dental resin

Search Result 1,271, Processing Time 0.025 seconds

Effects of bracket slot size during en-masse retraction of the six maxillary anterior teeth using an induction-heating typodont simulation system

  • Kim, Ji-Yong;Yu, Won-Jae;Koteswaracc, Prasad N.K.;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.47 no.3
    • /
    • pp.158-166
    • /
    • 2017
  • Objective: To investigate how bracket slot size affects the direction of maxillary anterior tooth movement when en-masse retraction is performed in sliding mechanics using an induction-heating typodont simulation system. Methods: An induction-heating typodont simulation system was designed based on the Calorific Machine system. The typodont included metal anterior and resin posterior teeth embedded in a sticky wax arch. Three bracket slot groups (0.018, 0.020, and 0.022 inch [in]) were tested. A retraction force of 250 g was applied in the posterior-superior direction. Results: In the anteroposterior direction, the cusp tip of the canine in the 0.020-in slot group moved more distally than in the 0.018-in slot group. In the vertical direction, all six anterior teeth were intruded in the 0.018-in slot group and extruded in the 0.020- and 0.022-in slot groups. The lateral incisor was significantly extruded in the 0.020- and 0.022-in slot groups. Significant differences in the crown linguoversion were found between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the central incisor and between the 0.018- and 0.022-in slot groups and 0.020- and 0.022-in slot groups for the canine. In the 0.018-in slot group, all anterior teeth showed crown mesial angulation. Significant differences were found between the 0.018- and 0.022-in slot groups for the lateral incisor and between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the canine. Conclusions: Use of 0.018-in slot brackets was effective for preventing extrusion and crown linguoversion of anterior teeth in sliding mechanics.

The Inhibition of Oxidative Stress by Chios Gum Mastic is Associated with Autophagy

  • Lee, Bo-Young;Lee, Kee-Hyun;Kim, In-Ryoung;Kim, Yong-Ho;Park, Hae-Ryoun;Park, Bong-Soo
    • International Journal of Oral Biology
    • /
    • v.39 no.2
    • /
    • pp.65-73
    • /
    • 2014
  • Chios Gum Mastic (CGM) is a natural resin extracted from the leaves of Pistacia lentiscus, a plant endemic to the Greek island of Chios. It has been used by traditional healers, and it has antibacterial, antifungal properties, and therapeutic benefits for the skin. The CGM reduces the formation of dental plaque and bacterial growth in oral saliva, and recent studies have demonstrated the role of antioxidant activity of CGM. Although CGM has been widely investigated, its protective effect against oxidative-damage to keratinocytes, as well as the relationship between CGM and autophagy, has not been investigated. The aim of this study was to assess the protective effect of CGM against $H_2O_2$-induced oxidative stress and to evaluate the autophagic features induced by CGM in human keratinocytes. The pretreatment with CGM significantly reduced apoptosis in $H_2O_2$-exposed HaCaT cells. It promoted the degradation of caspase-3, caspase-8, and caspase-9; and it induced the formation of the processed PARP. The treatment with CGM caused an increase in vesicle formation compared to control group. The level of p62 was reduced and the conversion of LC3-I to LC3-II was increased in CGM treated HaCaT cells. Also, the treatment with CGM increased cleavage of ATG5-ATG12 complex. In summary, CGM helps the cells to survive under stressful conditions by preventing apoptosis and enhancing autophagy. Besides, the present investigation provides evidence to support the antioxidant potential of CGM in vitro and opens up a new horizon for future experiments.

The effect of two artificial salivas on the adhesion of Candida albicans to heat-polymerized acrylic resin

  • Oncul, Burcin;Karakis, Duygu;Al, Funda Dogruman
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.93-97
    • /
    • 2015
  • PURPOSE. Xerostomia can diminish the quality of life, leads to changes in normal chemical composition of saliva and oral microbiata, and increases the risk for opportunistic infections, such as Candida albicans. Various artificial salivas have been considered for patients with xerostomia. However, the knowledge on the antifungal and antiadhesive activity of artificial saliva substitutes is limited. The aim of the present study was to evaluate influence of two artificial salivas on the adhesion of Candida albicans to the polymethylmethacrylate disc specimens. MATERIALS AND METHODS. Two commercial artificial salivas (Saliva Orthana and Biotene Oral Balance Gel) were selected. 45 polymethylmethacrylate disc specimens were prepared and randomly allocated into 3 groups; Saliva Orthana, Biotene-Oral Balance gel and distilled water. Specimens were stored in the artificial saliva or in the sterile distilled water for 60 minutes at $37^{\circ}C$. Then they were exposed to yeast suspensions including Candida albicans. Yeast cells were counted using ${\times}40$ magnification under a light microscope and data were analysed. RESULTS. Analysis of data indicated statistically significant difference in adhesion of Candida albicans among all experimental groups (P=.000). Findings indicated that Saliva Orthana had higher adhesion scores than the Biotene Oral Balance gel and distilled water (P<.05). CONCLUSION. In comparison of Saliva Orthana, the use of Biotene Oral Balance Gel including lysozyme, lactoferrin and peroxidase may be an appropriate treatment method to prevent of adhesion of Candida albicans and related infections in patients with xerostomia.

Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study

  • Aroso, Carlos;Silva, Antonio Sergio;Ustrell, Raul;Mendes, Jose Manuel;Braga, Ana Cristina;Berastegui, Esther;Escuin, Tomas
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.21-29
    • /
    • 2016
  • This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: $Clix^{(R)}$, Dalbo-$Plus^{(R)}$ and $Locator^{(R)}$. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and $37^{\circ}C$. The abutments were placed at angulations of $0^{\circ}$, $10^{\circ}$ and $20^{\circ}$. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation ($F_{(2.48)}=343619$, P<.05) and the type of attachment ($F_{(7.48)}=23.220$, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.

Fracture Resistance and Stress Distribution of All Ceramic Crowns with Two Types of Finish Line on Maxillary Central Incisor (IPS Empress 도재관의 파절강도: 하악 중절치에서 절단연 삭제량과 축면 경사도에 따른 영향)

  • Nam, Young-Sung;Kim, Kyea-Soon;Jung, Young-Chan;Kim, Yu-Lee;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.207-217
    • /
    • 2003
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the lower central ncisor. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results of this study were as follows : The fracture strength of the ceramic crown with 2.0mm depth and $12^{\circ}$ inclination was the highest (648 N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength (482 N). There were no significant differences of the fracture strength by axial inclination in same incisal depth group. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal depth. There had correlation between fracture strength and fractured surface area.

Intracisternal Antidepressants Suppressed the Nociceptive Jaw Opening Reflex in Freely Moving Rats

  • Ahn, Dong-Kuk;Kim, Yun-Sook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.3
    • /
    • pp.307-312
    • /
    • 1998
  • This study was performed to investigate the mechanism of central analgesic effects of antidepressants. Thirty four male rats were anesthetized with pentobarbital sodium (40 mg/kg, ip). A stainless steel guide cannula and a PE tube (PE10) were implanted into the lateral ventricle and cisterna magna area. Stimulating and recording electrodes were implanted into the incisor pulp and anterior digastric muscle. Electrodes were led subcutaneously to the miniature cranial connector sealed on the top of the skull with acrylic resin. The jaw opening reflex was used in freely moving rats, and antidepressants were administered intracisternally in order to eliminate the effects of anesthetic agents on the pain assessment and evaluate the importance of the central action site of antidepressants. After 48 hours of recovery from surgery, digastric electromyogram (dEMG) of freely moving rats was recorded. Electrical shocks (200 ${\mu}sec$ duration, 0.5-2 mA intensity) were delivered at 0.5 Hz to the dental pulp every 2 minute. Intracisternal administration of $15\;{\mu}g$ imipramine suppressed dEMG elicited by noxious electrical stimulation in the tooth pulp to $76{\pm}6%$ control. Intracisternal administration of $30\;{\mu}g$ desipramine, nortriptyline, or imipramine suppressed dEMG remarkably to $48{\pm}2,\;27{\pm}8,\;or\;25{\pm}5%$ of the control, respectively. Naloxone, methysergide, and phentolamine blocked the suppression of dEMG produced by intracisternal antidepressants from $23{\pm}2\;to\;69{\pm}4%,\;from\;32{\pm}5\;to\;80{\pm}9%,\;and\;from\;24{\pm}6\;to\;77{\pm}5%$ of the control, respectively. These results indicate that antidepressants produce antinociception through central mechanisms in the orofacial area. Antinociception of intracisternal antidepressants seems to be mediated by an augmentation of descending pain inhibitory influences on nociceptive pathways.

  • PDF

Friction Characteristics of Automotive Friction Materials with Ceramic Powder Contents (자동차용 마찰재에 함유된 세라믹분말의 함량에 따른 마찰특성)

  • Lee, Yong-Jin;Ryu, Jae-Kyung;Kim, Taik-Nam
    • Korean Journal of Materials Research
    • /
    • v.19 no.7
    • /
    • pp.403-406
    • /
    • 2009
  • The friction characteristics of automotive brake friction materials that contained different ceramic content were investigated. Several kinds of raw materials, such as resin-based binder, reinforcing fiber, friction restraint, abrasive, and filling materials were mixed, pressed, and heated in order to make the brake friction materials. The contents of SiC and $BaSO_4$ changed from 5 vol% to 20 vol%, respectively. In addition to this, the content of $Al_2O_3$ adjusted from 1 vol% to 16 vol%. The surface morphology of the SiC containing sample appeared rough while more debris was observed when the contents of SiC increased. This implies that the SiC containing brake composite was not adequate for the automobile. However, the relatively smooth surface was observed in samples that contained the $Al_2O_3$. But the roughness was low with a content of 11 vol% $Al_2O_3$ compared to the other samples. This is consistent with the abrasive properties of the samples. In the case of $BaSO_4$ containing samples, the smoothes surface was observed in the contents of 15 vol% $BaSO_4$. Thus, it was concluded that the 11 vol% $Al_2O_3$ and 15 vol% $BaSO_4$ containing composite would be the optimum content for the brake composite. Similar to the results of the surface morphology, the abrasion resistance consistently decreased when the content of SiC increased. On the contrary, the sample that contained 11 vol% $Al_2O_3$ and 15 vol% $BaSO_4$ showed the highest abrasion resistance compared to the other samples.

Changes in bisphenol A concentrations in urine according to sealant filling in children (치면열구전색 전후의 어린이 소변 내 Bisphenol-A의 농도 변화)

  • Shin, Ah Ra;Kim, Ji-Hye;Jeon, Eun Suk;Jung, Yun-Sook;Song, Keun-Bae;Choi, Youn-Hee
    • Journal of Korean Academy of Oral Health
    • /
    • v.41 no.4
    • /
    • pp.231-236
    • /
    • 2017
  • Objectives: The objectives of this study were to investigate the changes in bisphenol A (BPA) concentrations in urine from before to after sealant filling and the relationship between BPA and the number of teeth with sealed surfaces. Methods: Thirty-one children aged 6 and 7 years from three elementary schools in Daegu city who did not have any sealant and resin filling were selected as subjects. Urine samples were collected before and after sealant filling until 24 hours, with informed consent from their caregivers. The BPA concentration in all the collected urine samples was analyzed at Seegene Medical. Statistical analysis was performed using the Friedman test, Scheirer-Ray-Hope test, and the repeated-measures generalized linear mixed model of SPSS version 22.0. Results: The BPA concentrations increased from $3.49-{\mu}g/g$ creatinine before to $4.91-{\mu}g/g$ creatinine 2-3 hours later and to $4.15-{\mu}g/g$ creatinine after 24 hours. The more teeth with sealed surfaces, the higher the BPA concentration in children, but the difference was not statistically significant (P>0.05). Conclusions: The BPA concentrations were highest at 2-3 hours after sealant filling and decreased at 24 hours. Exposure to the sealant appears to have a meaningful correlation with the concentration of BPA in the urine of children.

A study of fracture loads and fracture characteristics of teeth

  • Sheen, Chang-Yong;Dong, Jin-Keun;Brantley, William Arthur;Han, David Seungho
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.3
    • /
    • pp.187-192
    • /
    • 2019
  • PURPOSE. The purpose of this in vitro study was to investigate the fracture loads and modes of failure for the full range of natural teeth under simulated occlusal loading. MATERIALS AND METHODS. One hundred and forty natural teeth were taken from mandibles and maxillas of patients. There were 14 groups of teeth with 10 teeth in each group (5 males and 5 females). Each specimen was embedded in resin and mounted on a positioning jig, with the long axis of the tooth at an inclined angle of 30 degrees. A universal testing machine was used to measure the compression load at which fracture of the tooth specimen occurred; loads were applied on the incisal edge and/or functional cusp. RESULTS. The mean fracture load for the mandibular first premolar was the highest (2002 N) of all the types of teeth, while the mean fracture load for the maxillary first premolar was the lowest (525 N). Mean fracture loads for the mandibular and maxillary incisors, and the first and second maxillary premolars, had significantly lower values compared to the other types of teeth. The mean fracture load for the teeth from males was significantly greater than that for the teeth from females. There was an inverse relationship between age and mean fracture load, in which older teeth had lower fracture loads compared to younger teeth. CONCLUSION. The mean fracture loads for natural teeth were significantly different, with dependence on tooth position and the sex and age of the individual.

Physical characteristics of ceramic/glass-polymer based CAD/CAM materials: Effect of finishing and polishing techniques

  • Ekici, Mugem Asli;Egilmez, Ferhan;Cekic-Nagas, Isil;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.128-137
    • /
    • 2019
  • PURPOSE. The aim of this study was to compare the effect of different finishing and polishing techniques on water absorption, water solubility, and microhardness of ceramic or glass-polymer based computer-aided design and computer-aided manufacturing (CAD/CAM) materials following thermocycling. MATERIALS AND METHODS. 150 disc-shaped specimens were prepared from three different hybrid materials and divided into five subgroups according to the applied surface polishing techniques. All specimens were subjected up to #4000 grit SiC paper grinding. No additional polishing has been done to the control group (Group I). Other polishing procedures were as follows: Group II: two-stage diamond impregnated polishing discs; Group III: yellow colored rubber based silicone discs; Group IV: diamond polishing paste; and Group V: Aluminum oxide polishing discs. Subsequently, 5000-cycles of thermocycling were applied. The analyses were conducted after 24 hours, 7 days, and 30 days of water immersion. Water absorption and water solubility results were analyzed by two-way ANOVA and Tukey post-hoc tests. Besides, microhardness data were compared by Kruskal-Wallis and MannWhitney U tests (P<.05). RESULTS. Surface polishing procedures had significant effects on water absorption and solubility and surface microhardness of resin ceramics (P<.05). Group IV exhibited the lowest water absorption and the highest microhardness values (P<.05). Immersion periods had no effect on the microhardness of hybrid ceramic materials (P>.05). CONCLUSION. Surface finishing and polishing procedures might negatively affect physical properties of hybrid ceramic materials. Nevertheless, immersion periods do not affect the microhardness of the materials. Final polishing by using diamond polishing paste can be recommended for all CAD/CAM materials.