• 제목/요약/키워드: dental prosthetic

검색결과 483건 처리시간 0.028초

이중미세나사산 임플란트의 임상적 및 방사선학적 1년 평가 (Clinical and radiographic evaluation of implants with dual-microthread: 1-year study)

  • 권미아;김용덕;정창모;이주연
    • Journal of Periodontal and Implant Science
    • /
    • 제39권1호
    • /
    • pp.27-36
    • /
    • 2009
  • Purpose: The stability of periodontal condition and marginal bone level were important to achieve long-term success of dental implant treatment. The aim of this study was to evaluate periodontal conditions and marginal bone loss around 67 GSII(OSSTEM, Seoul, Korea) dental implants with dual-microthread at the neck portion, 1 year after prosthetic loading. Materials and methods: Sixty-seven GS II dental implants in 27 patients(mean age; $47.4{\pm}14.0$ years) who received implant treatments at Pusan National University Hospital, were included in this study. Thirteen US II(OSSTEM, Seoul, Korea) implants with smooth neck design were selected for the control group. Periodontal and radiographic evaluations were carried out at baseline, 6 months and 12 months after prosthetic loading. Results: In the GS II group, plaque index(PI), gingival index(GI) and probing depth(PD) increased as time passed. In the US II group, GI and PD increased. Although marginal bone level was lower in the US II group in all evaluation periods, the changes between the periods were not statistically significant(p>0.05). In each period, periodontal parameters were not statistically significant between groups. Conclusion: One year after prosthetic loading, GS II and US II dental implants showed similar periodontal conditions and marginal bone response, and were within the criteria of success.

Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

  • Alom, Ghaith;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.12-23
    • /
    • 2021
  • Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.

The effect of the digital manufacturing technique of cantilevered implant-supported frameworks on abutment screw preload

  • Altuwaijri, Shahad Mohammmed;Alotaibi, Hanan Nejer;Alnassar, Talal Mughaileth
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.22-31
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate the misfit and screw preload at the implant abutment connection of implant supported fixed dental prosthesis with cantilever (ICFDP) manufactured using different digital manufacturing techniques and to compare the screw preload before and after cyclic loading. MATERIALS AND METHODS. Mandibular jaw model with four intra-foraminal implants was scanned using digital scanner. Stereolithography file was used to design a framework with nonengaging (NE) abutments and 10 mm cantilever distal to one terminal implant. Five frameworks were constructed using combined digital-conventional techniques (CAD-cast), and five frameworks were constructed using three-dimensional printing (3DP). Additional CAD-cast framework was constructed in a way that ensures passive fit (PF) to use as control. Scanning electron microscope (SEM) measured the implant abutment connection misfit. Sixty screws were used on the corresponding frameworks. Screws were torqued and pre-cyclic loading reverse torque value (RTV) was recorded. Frameworks were subjected to 200,000 loading cycles with a loading point 9 mm from the center of terminal implants adjacent to the cantilever and post-cyclic loading RTVs were recorded. RESULTS. Microscopic readings showed significant differences between frameworks. PF demonstrated the lowest measurements of 16.04 (2.6) ㎛ while CAD-cast demonstrated the highest measurements of 29.2 (3.1) ㎛. In all groups, RTVs were significantly lower than the applied torque. Post-cyclic loading RTV was significantly lower than pre-cyclic loading RTV in PF and 3DP frameworks. Differences in RTVs between the three manufacturing techniques were insignificant. CONCLUSION. Although CAD-cast and three-dimensionally printed (3DP) both produce frameworks with clinically acceptable misfit, 3DP might not be the technique of choice for maintaining screw's preload stability under an aggressive loading situation.

전신마취를 이용한 장애인의 보철치료 : 증례보고 (PROSTHETIC DENTISTRY PROCEDURES OF PERSONS WITH DISABILITIES UNDER GENERAL ANESTHESIA : A CASE REPORT)

  • 이정옥;이긍호;최영철
    • 대한소아치과학회지
    • /
    • 제27권1호
    • /
    • pp.146-150
    • /
    • 2000
  • 장애인은 일반적으로 구강관리에 대한 인식과 수행능력의 부족으로 구강위생상태가 불량하며, 치과질환의 발생빈도가 높고 그 정도가심한 편이다. 장애인의 치과치료시 많은 어려움이 따르는 행동조절은 장애의 종류와 정도에 따라 심리적 물리적, 약물적 방법 및 전신마취 등을 선택할 수 있으나, 여러 가지 이유로 인하여 일반적인 방법으로 치료가 불가능할 경우 전신마취를 이용하게 된다. 장애인 환자에 있어서 보철치료는 정상인에서와 다를 바가 없으나 장애정도에 따라 치과의사의 세심한 주의가 필요하며, 수복후에도 철저한 구강위생관리를 위해 환자 스스로나 보호자의 각별한 노력이 요구된다. 본 증례는 경도의 장애를 가지고 있으나 치과치료에 대한 불안과 공포가 심하고, 다수치아의 수복을 위하여 장시간의 치과 치료가 요구된 경우로서 전신마취를 이용한 보존 외과적 처치 및 보철치료를 시행하여 비교적 양호한 결과를 얻었다.

  • PDF

지르코니아 완전도재 수복 방법을 사용한 회전되고 변색된 상악중절치의 수복 (Restoration of Rotated and Discolored Maxillary Incisors with a Zirconia All-Ceramic System: A Case Report)

  • 백연화;임영준;김명주;권호범
    • 구강회복응용과학지
    • /
    • 제29권1호
    • /
    • pp.95-101
    • /
    • 2013
  • 최근 단시간에 비침윤적 방법으로 심미적인 개선을 바라는 치과 치료에 대한 요구가 증가하고 있다. 환자는 심미성의 한계에도 불구하고 교정, 치주, 신경치료 없이 보철적 치료방법만으로 상악 전치부의 심미적 개선을 원하였다. 이 증례에서는 최근에 소개된 여러 종류의 완전도재수복방법 중에서 변색된 치아를 차단하기 위해 지르코니아를 이용한 수복방법을 선택하였으며, 만족된 결과를 얻었다.

The cumulative survival rate of sandblasted, large-grit, acid-etched dental implants: a retrospective analysis

  • Haeji Yum;Hee-seung Han;Kitae Kim;Sungtae Kim;Young-Dan Cho
    • Journal of Periodontal and Implant Science
    • /
    • 제54권2호
    • /
    • pp.122-135
    • /
    • 2024
  • Purpose: This retrospective study aimed to assess the long-term cumulative survival rate of titanium, sandblasted, large-grit, acid-etched implants over a 10-year follow-up period and investigate the factors affecting the survival rate and change in marginal bone loss (MBL). Methods: The study included 400 patients who underwent dental implant placement at the Department of Periodontology of Seoul National University Dental Hospital (SNUDH) between 2005 and 2015. Panoramic radiographic images and dental records of patients were collected and examined using Kaplan-Meier analysis, Cox proportional hazards regression analysis, and multiple regression analysis to determine the survival rates and identify any factors related to implant failure and MBL. Results: A total of 782 implants were placed with a follow-up period ranging from 0 to 16 years (mean: 8.21±3.75 years). Overall, 25 implants were lost, resulting in a cumulative survival rate of 96.8%. Comparisons of the research variables regarding cumulative survival rate mostly yielded insignificant results. The mean mesial and distal MBLs were 1.85±2.31 mm and 1.59±2.03 mm, respectively. Factors influencing these values included age, diabetes mellitus (DM), jaw location, implant diameter, bone augmentation surgery, and prosthetic unit. Conclusions: This study found that the implant survival rates at SNUDH fell within the acceptable published criteria. The patients' sex, age, DM status, implant location, implant design, implant size, surgical type, bone augmentation, and prosthetic unit had no discernible influence on long-term implant survival. Sandblasted, large-grit, acid-etched implants might offer advantages in terms of implant longevity and consistent clinical outcomes.

Boded porcelain veneers revisited

  • Kim, Sun-Jae
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2007년도 Spring Scientific Meeting(the 127th) of Korean Academy if Conservative Dentistry
    • /
    • pp.303-303
    • /
    • 2007
  • PDF

Prosthodontics for the Next Millennium

  • Preiskel, Harold W.
    • 대한치과보철학회:학술대회논문집
    • /
    • 대한치과보철학회 1999년도 Asian Academy of Prosthodntics. Korean Academy of Prosthodontics
    • /
    • pp.30-31
    • /
    • 1999
  • PDF