• Title/Summary/Keyword: dental prosthetic

Search Result 483, Processing Time 0.029 seconds

Influence on Oral Health Condition by Visits to Dental Clinics and Dental Education Experience of East Asian Immigrant Women in Korea (동아시아 국내 이주여성의 치과방문여부와 구강건강교육유무가 구강건강상태에 미치는 영향)

  • Yun, Hyun-Kyuong;Choi, Mi-Sook;Choi, Gyu-Yil
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.409-417
    • /
    • 2012
  • Objectives : The purpose of this study is to figure out and establish the basic data that can help improve management of oral healthcare for the international marriage immigrant women. Methods : In this sense, we surveyed questions on 237 women out of 1,300 immigrant women, who have participated in the program by multi-cultural household supporting center, in a fashion of face-to-face investigation and on-the-spot direct cavity inspection simultaneously from May 1 to October 31, 2010. Collected data were electro-statistically computerized under SPSS 17.0 program and analyzed with frequency analysis, recurrence analysis and logistic regression analysis respectively. Results : The number of filled teeth got lower when they had lower number of dental visits. Women from the Philippines had the highest number of defect teeth, and the number of fixed prosthetic appliance became less when they had less number of dental visits. When they had no experience of oral health education, they had less fixed prosthetic appliances. There was higher percentage of periodontal disease when they did not have dental visit compared with the dental visit cases. Conclusions : Preparation of a policy for east Asian immigrant women for them to visit dentist comfortably and expansion of systematic oral health education are highly recommended.

Analysis of maxillofacial prosthetics at university dental hospitals in the capital region of Korea

  • Kim, Jee-Hwan;Shin, Soo-Yeon;Paek, Janghyun;Lee, Jong-Ho;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.229-234
    • /
    • 2016
  • PURPOSE. The purpose of this study was to investigate the demographic patterns of maxillofacial prosthetic treatment to identify the characteristics and geographic distribution of patients with maxillofacial prosthetics in the capital region of Korea. MATERIALS AND METHODS. This retrospective analytical multicenter study was performed by chart reviews. This study included patients who visited the department of prosthodontics at four university dental hospitals for maxillofacial prosthetic rehabilitation. Patients with facial and congenital defects or with insufficient medical data were excluded. The patients were classified into three categories based on the location of the defect. Patients' sex, age, and residential area were analyzed. Pearson's chi-square test with a significance level of 0.05 was used to analyze the variables. RESULTS. Among 540 patients with maxillofacial prosthetics, there were 284 (52.59%) male patients and 256 (47.41%) female patients. The number of the patients varied greatly by hospital. Most patients were older than 70, and the most common defect was a hard palate defect. Chi-square analysis did not identify any significant differences in sex, age, and distance to hospital for any defect group (P>.05). CONCLUSION. The results of this study indicated that there was imbalance in the distribution of patients with maxillofacial prosthetic among the hospitals in the capital region of Korea. Considerations on specialists and insurance policies for the improvement of maxillofacial prosthetics in Korea are required.

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.325-332
    • /
    • 2014
  • PURPOSE. The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS. A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clinical trials (RCT) and clinical trial studies comparing attachment systems on mandibular implant overdentures until December, 2011 were selected. Twenty nine studies were finally selected and the data about evaluation methods were collected. RESULTS. Evaluation criteria could be classified into 4 groups (implant survival, peri-implant tissue evaluation, prosthetic evaluation, and patient satisfaction). Among 29 studies, 21 studies presented implant survival rate, while any studies reporting implant failure did not present cumulative implant survival rate. Seventeen studies evaluating peri-implant tissue status presented following items as evaluation criteria; marginal bone level (14), plaque Index (13), probing depth (8), bleeding index (8), attachment gingiva level (8), gingival index (6), amount of keratinized gingiva (1). Eighteen studies evaluating prosthetic maintenance and complication also presented following items as evaluation criteria; loose matrix (17), female detachment (15), denture fracture (15), denture relining (14), abutment fracture (14), abutment screw loosening (11), and occlusal adjustment (9). Atypical questionnaire (9), Visual analog scales (VAS) (4), and Oral Health Impact Profile (OHIP) (1) were used as the format of criteria to evaluate patients satisfaction in 14 studies. CONCLUSION. For evaluation of implant overdenture, it is necessary to include cumulative survival rate for implant evaluation. It is suggested that peri-implant tissue evaluation criteria include marginal bone level, plaque index, bleeding index, probing depth, and attached gingiva level. It is also suggested that prosthetic evaluation criteria include loose matrix, female detachment, denture fracture, denture relining, abutment fracture, abutment screw loosening, and occlusal adjustment. Finally standardized criteria like OHIP-EDENT or VAS are required for patient satisfaction.

A Study on Satisfaction Factors with Dental Implant Patients (치과용 임플란트 보철물적용환자의 만족요인)

  • Lee, Sung-Uck;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.67-81
    • /
    • 2006
  • This research has been attempt to examine closely factors that high cost and value to overall satisfaction state for dental implant prosthesis, re-utilization intention, inducement intention of the general hospital dental service user and provide basis data necessary to establish competitive general hospital dentistry management strategy. Collected data using own recording way questionnaire from April 17, 2004 to May 15, 2004 choosing 142 people that agree on this research and question of 361 people that dental implant prosthetic treatment finished from March 1, 1999 to March 1, 2004 for this. Major analyzation consequences are as follows : First, general satisfaction, re-utilization intention, inducement intention for implant prosthesis that highly correlation variables are kindness, explanation, medical treatment level and appreciation of the aesthetic. Second, correlation is high relatively between re-utilization intention, inducement intention in the 3 variables such as general satisfaction re-utilization intention, inducement intention. Third, the result of multiple regression analysis showed that most significant effective factors are satisfaction with explanation of dental implant prosthesis between the 3 dependant variables such as general satisfaction, re-utilization intention, inducement intention. In looking into these consequence, how to improve that raise satisfaction about dental implant prosthetic treatment and to establish patient focused care service system for dental implant prosthesis, it is consider that explain enough about implant prosthesis and raise quality of medical examination and treatment level, including satisfied with fabrication of good esthetic dental implant prosthesis.

  • PDF

Aesthetic treatment of patient with facial asymmetry and severe gingival retraction (안면비대칭과 치은퇴축이 심한 환자의 심미치료)

  • Choi, Moon-Shik
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.50-63
    • /
    • 2016
  • Successful treatment in the anterior esthetic prosthetic can be a balance between aesthetics in the facial, tooth, and periodontal tissue in the oral. In the case of facial symmetry of patients with normal occlusal plane, If you establish criteria of finding balance of aesthetics such as a several books and articles and manufacture a prostheses by the established-criteria, you can manufacture a harmonious and aesthetic prostheses without any trouble. However, in the case of patients with facial asymmetry, if you manufacture a tooth as patient's facial aesthetic symmetry by force even facial asymmetry case, you can't get a result not only aesthetic but also functional prostheses. Also, to produce the prosthetic of harmonious and aesthetic with periodontal tissue, and excellent self-cleansing function, you must apply to the form of the prosthetic changed dental environment.

Effects of Nonprecious Metallic Oxide on the Chemical Bonding Between Dental Alloy and Porcelain (비귀금속 산화물이 치과용 합금과 도재의 화학적 결합에 미치는 영향)

  • Kim, Kwang-Nam;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.317-325
    • /
    • 1987
  • A study on the shear bonding strength between dental alloy and porcelain according to various kidns of sputtered metallic thin films was established by Ingtron universal testing machine, and the change of the elemental weight % at the surface of dental alloy was studied by E.D.S. The kind of metallic thin films were Al, Ni, In, Cr. Ti and Sn with $0.3{\mu}m$ thickness. The dental alloys were Verabond made by Aalba Dent. Co. and Degudent H manufactured by Degussa Co. The control groups were Verabond and Degudent H. The obtained results were as follows; 1. The shear bonding strength of Al plated sample was the strongest of all. 2. The shear bonding strength of Ni plated sample was stronger than that of Degudent H, Sn plated samples. 3. The shear bonding strength of Verabond was weaker than that of Al, Ni, In, Cr, plated samples. 4. After degassing, it is more weight % of Ni at the alloy surface of the Ni sputtered specimen than the Sn sputtered sample.

  • PDF

Effect of different arch widths on the accuracy of three intraoral scanners

  • Kaewbuasa, Narin;Ongthiemsak, Chakree
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.205-215
    • /
    • 2021
  • PURPOSE. The purpose of this study was to compare the accuracy of three intraoral scanner (IOS) systems with three different dental arch widths. MATERIALS AND METHODS. Three dental models with different intermolar widths (small, medium, and large) were attached to metal bars of different lengths (30, 40, and 50 mm). The bars were measured with a coordinate measuring machine and used as references. Three IOSs were compared: TRIOS 3 (TRI), True Definition (TD), and Dental Wings (DW). The relative length and angular deviation of both ends of the metal bars from the scan data set (n = 15) were calculated and analyzed. RESULTS. Comparing among scanners in terms of trueness, the relative length deviation of DW in the small (1.28%) and medium (1.08%) arches were significantly higher than TRI (0.46% and 0.48%) and TD (0.33% and 0.18%). The angular deviation of DW in the small (1.75°) and medium (1.83°) arches were also significantly greater than TRI (0.63° and 0.40°) and TD (0.55° and 0.89°). Comparing within scanner, the large arch of DW showed better accuracy than other arch sizes (P < .05). On the other hand, the larger arch of TD presented a greater tendency of angular deviation in terms of trueness. No significant differences were found in terms of trueness between the arch widths of TRI group. CONCLUSION. The different widths of the dental arches can affect the accuracy of some intraoral scanners in full arch scan.

Survival analysis of dental implants in maxillary and mandibular molar regions; A 4$\sim$5 year report ($\cdot$하악 대구치 부위에 식립된 임플란트의 생존율에 대한 후향적 연구)

  • Jang, Jin-Wha;Ryoo, Gyeong-Ho;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.165-180
    • /
    • 2007
  • Dental Implants have been proved to be successful prosthetic modality in edentulous patients for 10 years. However, there are few reports on the survival of implant according to location in molar regions. The purpose of this study was to evaluate the $4{\sim}5$ years' cumulative survival rate and the cause of failure of dental implants in different locations for maxillary and mandibular molars. Among the implants placed in molar regions in Gwangju Mir Dental Hospital from Jan. 2001 to Jun. 2002, 473 implants from 166 patients(age range; $26{\sim}75$) were followed and evaluated retrospectively for the causes of failure. We included 417 implants in 126 periodontally compromised patients, 56 implants in 40 periodontal healthy patients, and 205 maxillary and 268 mandibular molar implants. Implant survival rates by various subject factors, surgical factors, fixture factors, and prosthetic factors at each location were compared using Chi-square test and Kaplan-Meier cumulative survival analysis was done for follow-up(FU) periods. The overall failure rate at 5 years was 1O.2%(subject level) and 5.5%(implant level). The overall survival rates of implants during the FU periods were 94.5% with 91.3% in maxillary first molar, 91.1% in maxillary second molar, 99.2% in mandibular first molar and 94,8% in mandibular second molar regions. The survival rates differed significantly between both jaws and among different implant locations(p<0.05), whereas the survival rates of functionally loaded implants were similar in different locations. The survival rates were not different according to gender, age, previous periodontal status, surgery stage, bone graft type, or the prosthetic type. The overall survival rate was low in dental implant of too wide diameter(${\geq}5.75$ mm) and the survival rate was significantly lower for wider implant diameter(p

Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report (보철물 수복 형태에 따른 T-Scan Novus와 Dental prescale II를 이용한 교합력 평가 활용 증례)

  • Su-Hyun Choi;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.160-178
    • /
    • 2023
  • Diagnosis and analysis of occlusal relationships are important factors in prosthetic treatment. A thorough occlusion analysis and evaluation should be performed before treatment to restore a stable interocclusal relationship. Analysis and evaluation are essential during the treatment process and at regular follow-ups. Recently, with the development of dental equipment and digital processing methods, new quantitative analysis methods that can record the patient's occlusal relationship have been introduced. Among them, the T-Scan Novus (Tekscan Inc., S. Boston, MA, USA) displays the strength of the initial contact point and the occlusal contact point of the teeth using a pressure sensor. With this, occlusal contact time of the teeth, anteroposterior and left-right balance of occlusal force can be compared. The Dental prescale II (GC Co., Tokyo, Japan) scans the occlusal contact point using a pressure-sensing film and analyzes the density of the contact point. It can measure the distribution and strength of the occlusal force of the teeth in the most natural occlusion state. Based on this, appropriate prosthetic treatment (four-unit fixed partial denture, removable partial denture, complete denture, and complete oral restoration cases) was performed according to the area and extent of the patient's tooth loss. The patient's occlusion at the first visit, treatment stage, right after treatment, and regular follow-up were compared and evaluated using a quantitative method for appropriate occlusion analysis using T-Scan Novus and Dental prescale II. This report enhances the understanding of occlusion analysis during prosthetic restoration. The results satisfied both the clinician and patients in terms of function and aesthetics.

Requirements of the abutment teeth for long-term predictability of fixed prosthesis (고정성 보철치료의 영속성을 높이기 위한 지대치의 적합성)

  • Choi, Jeom-Il
    • The Journal of the Korean dental association
    • /
    • v.48 no.9
    • /
    • pp.654-663
    • /
    • 2010
  • The success in periodontal-prosthetic therapy lies in patient satisfaction with subjective and customized treatment regimen that has been refined for individual needs. To fulfill these requirements, multiple predictors may have to be taken into consideration in the comprehensive treatment planning. Incorporation of complex factors that guarantee the evidence-based therapy would include, but not limited to, osseous morphology, biotype of gingival around abutment, bone morphology of interdental bone and those around furcation area, abutment or bridge mobility. The periodontal-restorative interface should be of mutually protective. Also strategic and esthetic value of abutment teeth to be restored should also be taken into consideration. Taken together, all these should work in concert to enhance the predictability and longevity of abutment teeth in periodontal-prosthetic therapy.