• Title/Summary/Keyword: dental material

Search Result 1,380, Processing Time 0.028 seconds

Testing and evaluation of the corrosion behavior of Aluminum/Alumina bulk composites fabricated via combined stir casting and APB process

  • Abdalkareem Jasim;Ghassan Fadhil Smaisim;Abduladheem Turki Jalil;Surendar Aravindhan;Abdullah Hasan Jabbar;Shaymaa Abed Hussein;Muneam Hussein Ali;Muataz S. Alhassan;Yasser Fakri Mustafa
    • Advances in materials Research
    • /
    • v.12 no.4
    • /
    • pp.263-271
    • /
    • 2023
  • In this study, AA1060/Alumina composites were fabricated by combined stir casting and accumulative press bonding (APB). The APB process was repeated up to six press bonding steps at 300Ċ. As the novelty, potential dynamic polarization in 3.5Wt% NaCl solution was used to study the corrosion properties of these composites. The corrosion behavior of these samples was compared and studied with that of the annealed aluminum alloy 1060 and versus the number of APB steps. So, as a result of enhancing influence on the number of APB process, this experimental investigation showed a significant enhancement in the main electrochemical parameters and the inert character of the Alumina particles. Together with Reducing the active zones of the material surfaces could delay the corrosion process. Also, at higher number of steps, the corrosion resistance of composites improved. The sample produced after six number of steps had a low corrosion density in comparison with high corrosion density of annealed specimens. Also, the scanning electron microscopy (SEM), was used to study the corrosion surface of samples.

Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis

  • Peter Gehrke;Maria Julia Pietruska;Johannes Ladewig;Carsten Fischer;Robert Sader;Paul Weigl
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.4
    • /
    • pp.231-243
    • /
    • 2024
  • PURPOSE. The objective of the study was to analyze the impact of cement, bonding pretreatment, and ceramic abutment material on the overall color results of CAD-CAM ceramic crowns bonded to titanium-based hybrid abutments. MATERIALS AND METHODS. For single implant restoration of a maxillary lateral incisor a total of 51 CAD-CAM-fabricated monolithic lithium disilicate crowns were fabricated and subsequently bonded onto 24 lithium disilicate Ti-base abutments, 24 zirconia Ti-base abutments and 3 resin abutment replicas as a control group. The 48 copings were cemented with three definitive and one provisional cement on both grit-blasted and non-blasted Ti-bases. The color of each restoration and surrounding artificial gingiva was measured spectrophotometrically at predefined measuring points and the CIELAB (ΔEab) color scale values were recorded. RESULTS. The color outcome of ceramic crowns bonded to hybrid abutments and soft tissues was affected differently by cements of different brands. Grit-blasting of Ti-bases prior to cementing CAD-CAM copings affected the color results of allceramic crowns. There was a significant difference (P = .038) for the median ΔE value between blasted and non-blasted reconstructions at the cervical aspect of the crown. Full-ceramic crowns on zirconia Ti-base abutments exhibited significantly lower ΔE values below the threshold of visibility (ΔE 1.8). In all subcategories tested, the use of a highly opaque temporary cement demonstrated the lowest median ΔE for both the crown and the artificial gingiva. CONCLUSION. Various cements, core ceramic materials and airborne particle abrasion prior to bonding can adversely affect the color of Ti-base supported ceramic crowns and peri-implant soft tissue. However, zirconia CAD-CAM copings and an opaque cement can effectively mask this darkening.

A STUDY ON THE MICROLEAKAGE OF DENTIN BONDING SYSTEMS (상아질 접착제의 미세누출에 관한 연구)

  • Son, Jeong-Min;Choi, Nam-Ki;Kim, Seon-Mi;Yang, Kyu-Ho;Park, Yang, Ji-il
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.619-627
    • /
    • 2008
  • The objective of this study was to compare the microleakage of five adhesive systems in the enamel and dentin of permanent teeth. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of 25 extracted human molar teeth. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM), Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL) and G-Bond (GB). The results were as follows: 1. At the enamel margins, PL showed the highest leakage value(0.85), and others showed values of SB(0.55), GB(0.50), SM(0.35) and SE(0.25) in decreasing order. There were statistically significant differences in PL vs. SM and PL vs. SE(p<0.05). 2. At the dentin margins, GB showed the highest leakage value(2.10), and others showed values of SE(1.45), PL(1.40), SB(1.05), SM(0.70) in decreasing order. There were statistically significant differences in GB vs. SB and GB vs. SM(p<0.05). 3. Dentin margins showed high dye penetration rate than enamel margins in all material tested groups and there were statistically significant differences for SE, PL and GB.

  • PDF

Evaluation of static fracture resistances and patterns of pulpless tooth restored with poly-ether-ketone-ketone (PEKK) post (Poly-ether-ketone-ketone (PEKK) 포스트로 수복한 근관 치료 치아의 정적 파절 저항성 및 파절 형태에 관한 평가)

  • Park, Ha Eun;Lee, Cheol Won;Lee, Won Sup;Yang, Sung Eun;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.127-133
    • /
    • 2019
  • Purpose: The purpose of present study was to investigate fracture strength and mode of failure of endodontically treated teeth restored with metal cast post-core system, prefabricated fiber post system, and newly introduced polyetherketoneketone (PEKK) post-core system. Materials and methods: A total of 21 mandibular premolar were randomly grouped into 3 groups of 7 each according to the post material. Group A was for metal cast post core; Group B for prefabricated glass fiber post and resin core; and Group C for milled PEKK post cores. All specimens were restored with metal crown. The fracture strength of each specimen was measured by applying a static load of 135-degree to the tooth at 2 mm/min crosshead speed using a universal testing machine. After the fracture strength measurement, the mode of failure was observed. The results were analyzed using Kruscal-Wallis test and post hoc Mann-Whitney U test at confidence interval ${\alpha}=.05$. Results: Fracture resistance of PEKK post core was lower than those of cast metal post and fiber reinforced post with composite resin core. In the aspect of fracture mode most of the root fracture occurred in the metal post core, whereas the post detachment occurred mainly in the fiber reinforced post. In the case of PEKK post core, teeth and post were fractured together. Conclusion: It is necessary to select appropriate materials of post for extensively damaged teeth restoration and clinical application of the PEKK post seems to require more research on improvement of strength.

A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications (구치용 도재소부금관과 전부도재관에 파절을 일으키는 한국음식에 관한 연구)

  • Kim, Jeong-Ho;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.156-163
    • /
    • 2009
  • Statement of problem: Recently, there have been increased esthetic needs for posterior dental restorations. The failure of posterior dental ceramic restoration are possible not only by the characters of the component materials but also by the type of food. Purpose: The research aim was to compare the in vitro fracture resistance of simulated first molar crowns fabricated using 4 dental ceramic systems, full-porcelain-occlusal-surfaced PFG, half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon and selected Korean foods. Material and methods: Eighty axisymmetric crowns of each system were fabricated to fit a preparation with 1.5- to 2.0-mm occlusal reduction. The center of the occlusal surface on each of 15 specimens per ceramic system was axially loaded to fracture in a Instron 4465, and the maximum load(N) was recorded. Afterwards, selected Korean foods specimens(boiled crab, boiled chicken with bone, boiled beef rib, dried squid, dried anchovy, round candy, walnut shell) were prepared. 15 specimens per each food were placed under the Instron and the maximum fracture loads for them were recorded. The 95% confidence intervals of the characteristic failure load were compared between dental ceramic systems and Korean foods. Afterwards, on the basis of previous results, 14Hz cyclic load was applied on the 4 systems of dental ceramic restorations in MTS. The reults were analyzed by analysis of variance and Post Hoc tests. Results: 95% confidence intervals for mean of fracture load 1. full porcelain occlusal surfaced PFG Crown: 2599.3 to 2809.1 N 2. half porcelain occlusal surfaced PFG Crown: 3689.4 to 3819.8 N 3. Ice Zirkon Crown: 1501.2 to 1867.9 N 4. Empress 2 Crown: 803.2 to 1188.5 N 5. boiled crab: 294.1 to 367.9 N 6. boiled chicken with bone: 357.1 to 408.6 N 7. boiled beef rib: 4077.7 to 4356.0 N 8. dried squid: 147.5 to 190.5 N 9. dried anchovy: 35.6 to 46.5 N 10. round candy: 1900.5 to 2615.8 N 11. walnut shell: 85.7 to 373.1 N under cyclic load(14Hz) in MTS, fracture load and masticatory cycles are: 1. full porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 4796.8-9321.2 cycles under 2224.8 N(round candy)load, no fracture under smaller loads. 2. half porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 881705.1-1143565.7 cycles under 2224.8 N(round candy). no fracture under smaller loads. 3. Ice Zirkon Crown fractured at 95% confidence intervlas of 979993.0-1145773.4 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. 4. Empress 2 Crown fractured at 95% confidence intervals of 564.1-954.7 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. Conclusion: There was a significant difference in fracture resistance between experimental groups. Under single load, Korean foods than can cause fracture to the dental ceramic restorations are boiled beef rib and round candy. Even if there is no fracture under single load, cyclic dynamic load can fracture dental posterior ceramic crowns. Experimental data with 14 Hz dynamic cyclic load are obtained as follows. 1. PFG crown(full porcelain occlusion) was failed after mean 0.03 years under fracture load for round candy(2224.8 N). 2. PFG crown(half porcelain occlusion) was failed after mean 4.1 years under fracture load for round candy(2224.8 N). 3. Ice Zirkon crown was failed after mean 4.3 years under fracture load for boiled chicken with bone(382.9 N). 4. Empress 2 crown was failed after mean 0.003 years under fracture load for boiled chicken with bone(382.9 N).

Biocompatible Hydroxyapatite Ceramics Prepared from Natural Bones and Synthetic Materials (천연 및 인공원료로부터 제조한 생체친화형 하이드록시아파타이트 세라믹스)

  • Lee, Jong-Kook;Ko, Young-Hwa;Lee, Nan-Hee
    • Korean Journal of Materials Research
    • /
    • v.22 no.6
    • /
    • pp.285-291
    • /
    • 2012
  • Hydroxyapatite (HA) is well known as a biocompatible and bioactive material. HA has been practically applied as bone graft materials in a range of medical and dental fields. In this study, two types of dense hydroxyapatite ceramics were prepared from natural bones and synthetic materials. The biocompatibility of HA ceramics for supporting osteoblast cell growth and cytotoxicity using an in vitro MG-63 cell line model were respectively evaluated. Artificial hydroxyapatite shows relative density of 93% with 1-2 ${\mu}m$ after sintering, but a hydroxyapatite compact derived from bovine bone has low sintered density of 85% with a small content of MgO. Irrespective of the starting raw materials, both types of sintered hydroxyapatite displayed similar biocompatibility in the tests. FE-SEM observations showed that most MG-63 cells had a stellar shape and formed an intercellular matrix containing fibers on sintered HA. The cells were well attached and grown over the HA surface, indicating that there was no toxicity.

A Clinical Study on the Number of Occlusal Contact Points in Centric Occlusion (중심교합(中心咬合)에 있어서 교합면(咬合面) 접촉점수(接觸點數)에 관(關)한 임상적(臨床的) 연구(硏究))

  • Lee, Byung-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.37-41
    • /
    • 1968
  • The purpose of this paper is to evaluate the number of occlusal contacts in centric occlusion. The 50 strictly selected subjects, who have good natural dentition and occlusion, were impressioned with Alginate Impression material, and dental stone models were madel. After transfering the models from mouth to Hanau Articulator Model H2 by means of SM type Face-Bow, condylar guidances were registered, red articulating papers($13{\mu}$ in thickness) were inserted between upper and lower posterior teeth, and the red marked points and lines were counted as occlusal contact points. 1. The number of occlusal contact points in centric occlusion were 1st Molars 2nd Molars, 2nd Premolars and 1st Premolars in order. 2. The number of occlusal contact points of right side showed comparatively much more than those of left side. 3. The number of occlusal contact points of upper in Premolar area were much more than those of lower, and in Molar area were the reverse. 4. The total number of occlusal contact points in centric occlusion were approximately 105 points.

  • PDF

Cosmetic Grinding Revisited (Cosmetic Grinding의 재조명)

  • Lee, Dong-Hwan;Chung, Wounho
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.2
    • /
    • pp.134-142
    • /
    • 2015
  • Esthetic dentistry has been developed through the diverse material and technique. Approach and interest in esthetic of anteriors was driven by needs and wants of patients. Alpha and omega of esthetics is determined by patients, as Charles Pincus who is the pioneer of esthetic dentistry described in his article 1967. To meet with wants and needs of patients, dentists suggest possible various treatment options. Cosmetic grinding quoted by Pincus is one of the conservative approaches and provide effective esthetic improvement with minimal invasive concepts. In a high technology era, cosmetic grinding needs to be revisited. Review of some clinical cases shows the value and limitation of it.

Clinical Evaluation of Simultaneous Implants Placement Following Augmentation of the Maxillary Sinus with Deproteinized Bovine Bone (탈단백 우골을 이용한 상악동 거상술 후 즉시 임플란트 식립에 대한 임상적 평가)

  • Kim, Hyun-Kuk;Kim, Jin-Wook;Kim, Chin-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.249-255
    • /
    • 2011
  • Purpose: Placement of endosseous implants in the atrophic maxilla is often restricted because of the lack of supporting bone. In this article, augmentation of the maxillary sinus floor with deproteinized bovine bone to enable insertion of endosseous implants is described. The technique is aimed at providing a cortical layer on top of the graft to ensure a reliable seal of the maxillary sinus and to achieve optimal stability of the bone graft in case of simultaneously placement of dental implants. Methods: The procedure was used in 200 patients (839 implants), using deproteinized bovine bone. The mean follow-up was 28.5 months. No inflammation of the bone grafts nor of the maxillary sinus occurred. The patients received implant supported overdentures or bone-anchored bridges. Results: The survival rate of implant restoration of this study was 97.6%. The total average of marginal bone loss in radiographs was $0.20{\pm}0.38$ mm. Insufficient primary stability, bony quality, and infection were thought to be associated factors in the failed cases. Conclusion: This study documented that deproteinized bovine bone, when used as a grafting material for augmentation of the sinus floor, may lead to proper osseointegration of a endosseous implant.

Effects of Chitosan on the Differentiation of MDPC-23 Cells

  • Park, Ju-Hyun;Kim, Do-Kyung;Park, Jong-Tae;Kim, Su-Young;Yu, Sun-Kyoung;Cho, Kwang-Hee;Kim, Heung-Joong
    • International Journal of Oral Biology
    • /
    • v.35 no.3
    • /
    • pp.91-97
    • /
    • 2010
  • The effects of chitosan upon the experimentally induced differentiation of MDPC-23 cells, derived from mouse dental papilla cells, were investigated by RT-PCR, observations of cell morphology and Alizaline red-S staining. Chitosan was found to significantly increase and accelerate the expression of ALP mRNA but decrease the ColI transcript levels, as compared with the control, in a time-dependent manner during the differentiation of MDPC-23 cells. Chitosan also significantly downregulated ON mRNA expression and accelerated mineralization in differentiating MDPC-23 cells. These results suggest that chitosan facilitates odontoblast differentiation and mineralization and may have potential clinical applications as a dentin regeneration material.