• Title/Summary/Keyword: dental material

Search Result 1,380, Processing Time 0.028 seconds

A study on the safety and efficacy of bovine bone-derived bone graft material(OCS-B) (생체 유래 골 이식재(OCS-B)의 안전성 및 유효성에 관한 연구)

  • Park, Ho-Nam;Han, Sang-Hyuk;Kim, Kyoung-Hwa;Lee, Sang-Chul;Park, Yoon-Jeong;Lee, Sang-Hoon;Kim, Tae-Il;Seol, Yang-Jo;Ku, Young;Rhyu, In-Chul;Han, Soo-Boo;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.335-343
    • /
    • 2005
  • Inorganic bovine bone mineral has been widely researched as bone substitution materials in orthopedic and oral and maxillofacial application. OCS-B(NIBEC, Korea) is newly-developed inorganic bovine bone mineral. The aim of this study is to evaluate the safety and efficacy of bovine bone-derived bone graft material(OCS-B). Micro-structure of newly-developed inorganic bovine bone mineral(OCS-B) was analyzed by scanning electron microscope(SEM). Round cranial defects with eight mm diameter were made and filled with OCS-B in rabbits. OCS-B was inserted into femoral quadrant muscle in mouse. In scanning electron microscope, OCS-B was equal to natural hydroxyapatite. Rabbits were sacrificed at 2 weeks and 4 weeks after surgery and mice were sacrificed at 1 week and 2 weeks after surgery. Decalcified specimens were prepared and observed by microscope. In calvarial defects, osteoid and new bone were formed in the neighborhood of OCS-B at 2 weeks after surgery. And at 4 weeks after surgery osteoid and new bone bridge formed flourishingly. No inflammatory cells were seen on the surface of OCS-B at 1 week and 2 weeks in mouse experimental group. It is concluded that newly-developed inorganic bovine bone mineral(OCS-B) is a flourishing bone-forming material and biocompatible material.

Chemical compatibility of interim material and bonding agent on shear bond strength (임시수복 재료와 본딩제의 화학적 호환성이 전단결합강도에 미치는 영향)

  • Lee, Jonghyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.293-300
    • /
    • 2016
  • Purpose: The purpose of this study is finding proper bonding agents to be used when adding bis-acryl composite provisional materials. Materials and Methods: Three bonding agents with different chemical compositions were included in this study. Forty disk shaped specimens of bis-acryl composite provisional material were prepared and divided into 4 groups according to the bonding agents. Control group didn't have bonding agent. Through the Teflon mould with 4.0 mm diameter hole with 4.0 mm thickness the same bis-acryl composite provisional material was added on the disks after the surface of each specimen was treated with designated bonding agent according to the manufacturer's instructions. Shear bond test was performed and the fractured surfaces were inspected with a microscope. One-way analysis of variance was conducted and the result was further analysed with Turkey post hoc test at the significance level of 0.05. Results: The highest strength was acquired from the specimens bonded with chemical cure system and it was statistically significant (P < 0.05). This group showed 100% cohesive failures. The lowest bonding strength was recorded from the specimens used conventional light cure bonding agent, and this group's result was similar with the control group. The group used a light cure bonding agent claiming improved compatibility revealed significantly higher bond strength to the traditional light cure bonding agent group in a statistically significant way (P = 0.043). Conclusion: According to the bonding agent used the shear bond strength was significantly affected. Therefore the choice of proper bonding agent is important when hiring a bonding agent to add bis-acryl composite provisional materials.

THE THICKNESS OF SOFT-TISSUE BASED ON BODY MASS INDEX AND POSTOPERATIVE CHANGE IN PROGNATHIC PATIENTS (골격성 III급 부정교합자의 체질량지수에 따른 술후 연조직 변화)

  • Kim, Eun-Cheol;Lee, Sang-Chull
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.3
    • /
    • pp.288-297
    • /
    • 1999
  • This study has been carried out in order to measure the thickness of soft-tissue on lateral cephalographs based on body mass index(BMI) and the change in soft-tissue thickness after surgical correction of mandibular protrusion. The control material in cephalometric study comprised students at The Dental College, 38 persons, aged 21~24 years and the patient material comprised 20 women and 12men, aged 19~28 years with mandibular protrusion.The thickness of the soft-tissue based on BMI in control and study groups, the comparison between them, immediate postoperative change in the thickness, 6 months after surgery, ratio of soft-tissue response and correlation was established through various statistical methods. The result were as follows : 1. The groups based on BMI showed significant differences each other as regards the linear measurements. The thickest soft-tissue was measured 13.6mm, 15.47mm, 16.76mm at Ss, the thinnest at G' 6.0mm, 6.7mm, 7.26mm respectively. 2. The differences between control and experimental groups based on BMI showed to be significant. There were no differences at G'. The soft-tissue in prognathic patients was thicker at Ss, Ls and thinner at Li, Ls, Pg', Gn', Me'. Differential gap was greater in overweight groups. 3. The immediate soft-tissue change after surgery showed the increase at Li, Ls, Pg', Gn', Me' except G', Ls in all groups. 4. The postoperative soft-tissue change 6 months after surgery was similar with immediate change. The soft-tissue shows the increase in the thickness at Li, Pg', Gn', Me' and the greatest difference occurred at Li, 1.1mm, 0.98mm, 1.2mm respectively. 5. The patients with lower BMI index showed higher soft-tissue response to bony movement at Pg'. The immediate response ratio was 91%, 87%, 81% in A,B,C groups respectively, the response 6 months after surgery showed 96%, 91%, 84%.

  • PDF

Design and Evaluation of Ultrasonic dental scaler produced for Finite Element Analysis (유한요소 해석을 통한 치과용 초음파 Scaler의 설계 및 평가)

  • Kim, Chul-Min;Lee, Young-Jin;Jeong, Young-Hun;Paik, Jong-Hoo;Kang, Kook-Jin;Lee, Jeong-Bae;Lee, Seung-Dae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.20-20
    • /
    • 2009
  • 치아의 치석제거 및 치골절삭에 사용되는 초음파 스케일러는 일반적으로 마그넷형과 압전형으로 구분할 수 있으며, 최근에 들어 소형화, 저전력, 정밀성, 저비용 등의 장점으로 인해 압전형이 주로 사용되고 있다. 국내의 대부분의 치과에서 한 대 이상 운용되는 초음파 스케일러는 대부분 유럽 제품으로며, 국내에서는 이를 대체하기 위한 제품이 출시되고 있으나 아직까지 유럽 제품에 비해 출력강도, 정밀도 등에서 성능이 모자란 현실로 시장에서 외면 받고 있다. 본 연구에서는 앞서 언급한 압전 초음파 스케일러에 대한 체계적인 연구를 진행하여 외국에 비해 상대적으로 성능이 떨어지는 초음파 스케일러의 성능을 개선하고자 하였다. 이를 위하여 스케일러의 진동 발생부, 즉 압전 세라믹과 SUS 재질의 head, tail 부로 구성된 진동발생부의 최적구조톨 도출하기 위하여 유한요소 해석을 실시하였으며, 스케일러의 중심주파수 28kHz에서 최대 출력이 발생할 수 있는 구조를 도출하였다. 스케일러의 Head 와 Tail 부문의 두께와 직경, 길이 변화에 따른 중심주파수 및 출력 변위의 경향분석을 실시하였으며, 이상의 결과를 바탕으로 실제 스케일러를 제작하여 시뮬레이션의 유효성을 검증하였다. 이상의 과정으로 거쳐 개발된 압전 초음파 스케일러는 다양한 Tip 종류의 영향을 최소화할 수 있으며, 중심주파수는 28~30kHz 에서 뛰어난 성능을 나타내어 기종 유럽제품의 성능을 앞지르는 특성을 확보할 수 있었다.

  • PDF

A STUDY OF SCREW LOOSENING AFTER DYNAMIC CONTINOUS FATIGUE TEST OF SEVERAL ABUTMENT SCREW (수종 임플랜트 지대주나사의 반복하중 후 나사풀림에 관한 연구)

  • Kim Jin-Man;Han Jung-Suk;Lee Sun-Hyung;Yang Jae-Ho;Lee Jae-Bong;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.519-531
    • /
    • 2003
  • Statement of problem : Chronic implant screw loosening remains a problem in restorative practices. Some implant manufactureres have introduced abutment screws with treated material, surfaces and macrostructures in an effort to reduce potential loosening. Purpose : This study evaluated the materials and loading cycles on detorque value after dynamic continous fatigue test in the sinulated conditions of posterior single restoration. Material and method : Fourteen of each of the following abutment screws - titanium alloy, gold alloy, gold-tite, and titanium alloy modified - were used in test. SEM is used to verify macrostructures of each screws. $ZrO_2/Al_2O_3$ composite abutment was tightened on $4{\times}10.0mm$ titanium external implant at 30 Ncm. Cyclic loading machine delivered dynamic loading forces between 20 and 320N for 100,000, 200,000, 300,000, 500,000, and 1,000,000 cycles at frequencies 14Hz. Torque and detorque value after loading was measured. Results : All measued screws had different screw length and thread form. Titanium modified screw had greater detorque value than others before and after cyclic loadings(p<0.05). All abutment screws had no significant change in mean percentage of detorque value after loading to initial value after less than 500.000 cyclic loadings, but significant lower value after 1,000,000 cycles(p<0.05). Conclusion : Within limintations of this study all abutment screws may be loosend after about 1 year use. Annual check-up is nessasary to prevent screw loosening.

STRAIN CHANGES OF ACRYLIC RESIN SPECIMENS CURED BY THREE CURING CYCLES

  • Kang, In-Ho;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.236-245
    • /
    • 2002
  • The acrylic resin was first introduced as denture base materials in 1937 and it is commonly used for denture base fabrication nowadays. Three different curing cycles (Conventional curing cycle, short curing cycle and long curing cycle) and three commercially available heat-activated acrylic resins (Vertex RS, Lucitone 199 and ProBase Hot) were investigated to find the curing cycle and material that showed the minimum shrinkage of the resin during polymerization process. A brass master mold was fabricated and duplicated by additional silicone impression material. Stone molds were made by pouring of type III dental stone (SILKY-ROCK YELLOW, Whip-Mix, Louisville, Kentucky). It was embedded in the flask. Strain gauge and thermocouple were embedded in the specimen. Strain gauge and thermocouple were connected to signal conditioning amplifier and data was recorded by pre-programmed software. The parameters ESmax (Maximum expansion strain), Sb (Strain measured just before deflasking procedure), Sa (Strain measured just after deflasking procedure) and Sf (Strain measured at the end of the experiment) were measured. ${\Delta}$S was calculated from Sb and Sa (${\Delta}$S=Sb-Sa). In the experiment concerned about materials, the parameters 90-ESmax (Maximum expansion strain measured during early 90 minutes of curing procedure), 180-ESmax (Maximum expansion strain measured from 90 minutes to 180 minutes), Sb, Sa, ${\Delta}$S and Sf were measured and the following conclusions were made. 1. The ESmax value of conventional curing cycle showed the largest value and the 180-ESmax value of Lucitone 199 showed the smallest value. 90-ESmax values showed no significant difference (p<0.05). 2. ${\Delta}$S values of conventional curing cycle showed the positive values. ${\Delta}$S values of short curing cycle and long curing cycle showed the negative values. All three materials cured by conventional curing cycle showed the positive values. 3. The Sf values of long curing cycle and ProBase Hot (cured by conventional curing cycle) showed the smallest values.

Clinical Evaluation of Occlusal Contact Changes in Implant Prosthesis (임플란트 보철의 교합 접촉 변화에 대한 임상적 평가)

  • Yun, Chul-Hee;Kim, Dae-Gon;Yi, Yang-Jin;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • Despite of the successful clinical performance of implants, it is still lacking of the knowledge of changes in implant occlusion. The purpose of this study was to evaluate the changes of infraocclusal contact after clinical occlusal function of implant. Twenty patients(38 implants) were recalled during 10 months after placement of implant prosthesis. Occlusion changes were investigated at placement, placement 1 months, 4 months and 10 months serially with silicone bite material and T-Scan II sensor. Bony changes were also evaluated with periapical radiographs. The changes of silicone thickness and T-Scan II sensored areas were statistically analyzed with repeated measured ANOVA and the Scheffe's post-hoc test at the 95% significance level. The following results have been made based on this study: 1. Alveolar bone loss was within 0.20mm and it was generally concluded within physiologic level. 2. There were no statistically significant differences in the thickness changes of silicone material at 1 month and 4 months of occlusal function. However, there was statistically significant difference at 10 months of occlusal function (p<0.05). 3. There was no statistically significant difference in changes of occlusal contact area in T-Scan II at 1 month and 4 months of occlusal function, but there was statistically significant difference at 10 months of occlusal function (p<0.05). Conclusively, as time goes by, implant occlusion to be formed infraocclusion was to be far close and increased occlusal contact. However, it was not observed destructive bone resorption in periapical radiographs and any other side effects.

Evaluation of Microleakage with Retrograde Filling Materials in Blood Contamination (혈액 오염된 역충전 재료의 미세누출 평가)

  • Cho, Hye-Jin;Moon, Jhong-Hyun;Chon, Seong-Min;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.85-93
    • /
    • 2007
  • The purpose of this study was to evaluate the microleakage of root-end filling material filled in blood contaminated root-end cavity and self-etching adhesive placed over blood contaminated resected root apices without root-end preparation. Extracted, human maxillary incisors, canines and mandibular premolar were randomly divided into four groups of 15 teeth each. After canal preparation, resection of the apex and root-end preparation, MTA and IRM were filled in the root-end cavity (A and B group). After canal preparation and resection of the apex, Clearfil SE Bond and Prompt L-Pop were applied over the contaminated root-end surfaces (C and D group). The roots were then subjected to 15cm of water pressure to simulate periapical microleakage stress. Data were analyzed using one-way ANOVA. The results were as follows : 1. All groups showed a tendency of decreasing microleakage in process of time after 2weeks later except IRM group. 2. After 2 weeks and 1 month, MTA group showed less microleakage significantly than other groups(p<0.05). After 2 months, Prompt L-Pop group showed less microleakage significantly than other groups(p<0.05). 3. After 9 months, there were no significant differences among four groups(p>0.05). Thus it is considered that apical sealing using adhesives system without root-end preparation is good method in endodontic surgery.

Influence of the connection design and titanium grades of the implant complex on resistance under static loading

  • Park, Su-Jung;Lee, Suk-Won;Leesungbok, Richard;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.388-395
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the resistance to deformation under static overloading by measuring yield and fracture strength, and to analyze the failure characteristics of implant assemblies made of different titanium grades and connections. MATERIALS AND METHODS. Six groups of implant assemblies were fabricated according to ISO 14801 (n=10). These consisted of the combinations of 3 platform connections (external, internal, and morse tapered) and 2 materials (titanium grade 2 and titanium grade 4). Yield strength and fracture strength were evaluated with a computer-controlled Universal Testing Machine, and failed implant assemblies were classified and analyzed by optical microscopy. The data were analyzed using the One-way analysis of variance (ANOVA) and Student's t-test with the level of significance at P=.05. RESULTS. The group $IT4_S$ had the significantly highest values and group IT2 the lowest, for both yield strength and fracture strength. Groups $IT4_N$ and ET4 had similar yield and fracture strengths despite having different connection designs. Group MT2 and group IT2 had significant differences in yield and fracture strength although they were made by the same material as titanium grade 2. The implant system of the similar fixture-abutment interfaces and the same materials showed the similar characteristics of deformation. CONCLUSION. A longer internal connection and titanium grade 4 of the implant system is advantageous for static overloading condition. However, it is not only the connection design that affects the stability. The strength of the titanium grade as material is also important since it affects the implant stability. When using the implant system made of titanium grade 2, a larger diameter fixture should be selected in order to provide enough strength to withstand overloading.

Effects of staining liquids and finishing methods on translucency of a hybrid ceramic material having two different translucency levels

  • Buyukkaplan, Sebnem Ulviye;Ozarslan, Mehmet Mustafa;Barutcigil, Cagatay;Arslan, Merve;Barutcigil, Kubilay;Yoldan, Elif Ece
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.387-393
    • /
    • 2017
  • PURPOSE. Beverages may affect the translucency of esthetic dental restorative materials.The aim of the present study was to investigate the effects of coffee and red wine on the translucency of a PICN material with two translucency levels, and finished with different methods. MATERIALS AND METHODS. 2M2 high translucent and translucent VITA Enamic hybrid ceramic blocks were investigated. Rectangular specimens with the dimensions of $12mm{\times}14mm{\times}2mm$ were prepared. The specimens were finished and polished with different methods as suggested by the manufacturer. The translucency parameters of the specimens were evaluated before and after 24 hours, 7 days, and 28 days immersion in distilled water, coffee and red wine. Translucency parameters were measured using a portable spectrophotometer. RESULTS. At the end of 28 days, there was no statistically significant difference between the groups of specimens kept in coffee (P>.05). In the red wine groups, there was a statistically significant difference between the control group and all other groups (P<.05) at the end of 28 days. CONCLUSION. The translucency of hybrid ceramic for a restoration may not be important regarding the effects of coffee on translucency change because the specimens with different translucencies and finishing methods that were immersed to coffee had similar translucency parameters at the end of 28 days. The translucency of hybrid ceramic may be important in the case of red wine, however, since the results showed that highly translucent specimens exposed to red wine demonstrated better translucency parameters than specimens made from translucent blocks at the end of 28 days.