• Title/Summary/Keyword: dental material

Search Result 1,380, Processing Time 0.028 seconds

A STUDY OF GOLDEN PROPORTION APPLICATION IN KOREAN NORMAL DENTITION (조화된 치열의 황금분할에 관한 연구)

  • Ryu, Seong-Hee;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.17 no.1
    • /
    • pp.93-106
    • /
    • 1987
  • The purpose of this study was to investigate the fittness of Golden relation items was advocated by Ricketts whether or not it is applicable to the young adult Korean dentitions and also to evaluate the several new Golden relation items conducted by the author. The material was consisted of 81 dental casts (34 male, 47 female) with ideal occlusion, which never undergone orthodontic, prosthodontic procedures. Measurements were made on the arch dimensions using sliding caliper (Mitutoyo. Co) and data were computerized and analyzed. The findings of this study were as follows, 1. The Golden proportion advocated by Ricketts dose not seem to directly applicable to the Korean normal dentition, however, the modification from the Ricketts' original shows the Golden proportion as follow: A first series of progressive Golden relations was found on the Golden ratio among the lower central incisors width, the inter mesioincisal width of the upper lateral incisors, and the upper first premolars width. A second series was found on the Golden ratio among the lower lateral incisors width, lower inter canine tips width and theupper first molar distal cusp tips width. A third series was found on the Golden ratio between the inter distal aspect width of e lower canine and the mesial cusp tips width of the lower second molars or inter cusp tips width of upper second premolars. 2. In addition to Ricketts' original, 4 new Golden proportions were found in young adult Korean dentition, these are as follows; The tips of lower canine width had Golden relation with the width of the upper first premolar buccal cusp tips or the width of the lower first molar central fossae. The distal aspect of the lower first premolars had Golden relation with the buccal surface widths of the lower or upper second molars. The width of upper lateral incisors had Golden relation with the upper second molar height. The width of the lower canine tips had Golden relation with the lower second molar height.

  • PDF

Low-shrinking composites. Are they reliable for bonding orthodontic retainers?

  • Uysal, Tancan;Sakin, Caglar;AI-Qunaian, Talal
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Objective: To evaluate the shear bond strength (SBS), fracture mode, wire pull out (WPO) resistance and microleakage between low-shrinking and conventional composites used as a lingual retainer adhesive. Methods: A total of 120 human mandibular incisor teeth, extracted for periodontal reasons, were collected. Sixty of them were separated into two groups. To determine the SBS, either Transbond-LR (3M-Unitek) or Silorane (3M-Espe) was applied to the lingual surface of the teeth by packing the material into standard cylindrical plastic matrices (Ultradent) to simulate the lingual retainer bonding area. To test WPO resistance, 20 samples were prepared for each composite where the wire was embedded in the composite materialand cured. Then tensile stress was applied until failure of the composite occurred. The remaining 60 teeth were divided into two groups and multi-stranded 0.0215-inch diameter wire was bonded with the same composites. Microleakage was evaluated by the dye penetration method. Statistical analyses were performed by Wilcoxon, Pearson chi-square, and Mann-Whitney-U tests at p < 0.05 level. Results: The SBS and WPO results were not statistically significant between the two groups. Significant differences were found between the groups in terms of fracture mode (p < 0.001). Greater percentages of the fractures showed mix type failure (85%) for Silorane and adhesive (60%) for Transbond-LR. Microleakage values were lower in low-shrinking composite than the control and this difference was found to be statistically significant (p < 0.001). Conclusions: Low-shrinking composite produced sufficient SBS, WPO and microleakage values on the etched enamel surfaces, when used as a lingual retainer composite.

THE HISTOLOGIC STUDY OF THE GRAFTED hBMP-I FOR IMMEDIATE IMPLANT FIXATION (발치 후 즉시 임플란트 식립시 이식된 hBMP-I의 조직학적 고찰)

  • Lee, Eun-Young;Kim, Kyoung-Won;Choi, Hee-Won;Um, In-Woong;Chung, Ho-Yong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.316-322
    • /
    • 2004
  • A low molecular weight component named bone morphogenetic protein(BMP) chemically isolated from the organic matrix of bone, induce postfetal connective tissue cells surrounding small blood vessels to differentiate into cartilage and bone. The end product of BMP is a spherical ossicle of lamella bone filled with red bone marrow for the functional loading. This is a important point that the graft material is embedded the defect site during the implant surgery. Because present knowledge of the relationship between BMP and bone regeneration arises mainly from studies of induced bone formation in heterotopic sites, it would be helpful to determine whether BMP plays any part in the process of bone healing. The BMPs have been shown to play crucial roles in normal skeletal development as well as bone healing and are able to activate transcription of genes involved in cellular migration, proliferation, and differentiation. The delivery of BMP on matrices has been efficacious in the treatment of defect bone in implant surgery. The purpose of the histologic study was to evaluate the effect of DLB(demineralized lyophilized bone) coated with purified human BMP(hBMP-I) in immediate implant surgery with bony defect to obtain the functional structure of implant asap. The ability of a graft of hBMP-I to accelerate bony defect repair provides a rationale for its use in immediate implant surgery that have large bone defect in edentulous area.

A RETROSPECTIVE STUDY OF THE SURGICAL SUCCESS AND VERTICAL BONE RESORPTION RATE AFTER AUTOGENOUS BLOCK ONLAY GRAFT IN POSTERIOR MAXILLA (상악 구치부에서 자가골편 이식술의 예후와 골 변화량에 관한 후향적 연구)

  • Myoung, Mee-Rang;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.340-345
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the surgical success of bone reconstruction of the severely atrophic maxilla using autogenous block bone onlay graft from the ramus and ilium prior to dental implantation. And we measured the amount of vertical height change Material and Methods: 26 partially edentulous patients(32 case) who needed block onlay bone graft before implant placement in posterior maxillary area from 2002 to 2009 were selected for this study. Patients consisted of 20 males & 6 females and the average of their age was 54.2. Patients who were treated with ramal bone were 19 case and patients who were treated with iliac bone were 11 case. Digital panoramic X-ray was taken at the day of surgery, 3 months and 6 months later after the surgery. Vertical height change & resorption rate of grafted bone were measured with the same X-rays and compared Results: Two out of 32 bone grafts had to be removed because of inflamation at the grafts area(97.3%). The mean of radiographic vertical height change(change rate) of post-op. 3 month was 0.54mm(8.5%)and 6 month was 0.99mm(15.9%). Compairing to intraoral donor site(ramus), iliac bone had more vertical height change(1.18mm) at 6 month after surgery. Conclusions: Within the limit of this study, autogenous block onlay grafts can be considered a promising treatment for severely atrophic maxilla.

CLINICAL & RADIOGRAPHIC EVALUATION FOLLOWING DELAYED IMPLANTATION USING REGULAR DIAMETER IMPLANTS IN THE POSTERIOR REGION (구치부에 발치 후 지연 식립된 표준 직경의 임플란트에 대한 임상적, 방사선학적 평가)

  • Choi, Jung-Yong;Lee, Sang-Hwa;Yoon, Hyun-Joong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.335-339
    • /
    • 2009
  • The purpose of this study was to evaluate clinical and radiographic changes of regular diameter implants placed in the posterior region. A total of 47 standard diameter implants were consecutively placed in the posterior region of 20 partially edentulous patients. The diameters of the implants were 4.1mm (N=35, 74%) and 4.3mm (N=12, 26%), respectively. Peri-implant bone loss and clinical parameters such as mobility, suppuration, swelling, bleeding on probing (BOP) were evaluated at the baseline and?the final follow-up visit. The age of the patients ranged between 24~82 years (mean age: 54.7 years). The cumulative survival rate of the regular diameter implants loaded for a period of 3-24 months (Mean: $11.7{\pm}7.9$ month) was 100%. The average bone loss over the follow-up was $0.36{\pm}0.67\;mm$. Success rate was 95.7%. Only two implants failed (bone loss exceeding 1mm after 1 year of placement). Some prosthetic complications occurred, such as screw loosening (N=1) and dissolution of cementation material (N=2). The present study describes successful outcome following the use of standard-diameter-implants placed in the posterior region, and further comprehensive maintenance practices and follow-up schedules are required.

THE SURVEY ON ORAL HEALTH AND MAXILLOFACIAL TRAUMA INCIDENCE OF THE SPORTS PLAYERS IN KOREA (운동선수들의 구강 악 안면 영역에서의 스포츠 외상에 관한 설문조사)

  • Park, Neung-Seog;Woo, Yi-Hyung;Bak, Jin;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.534-545
    • /
    • 2007
  • Statement of problem: In spite of increasing sports injury, there was no collected data on the rate and type of dental injuries for athletes in Korea. Purpose: The purpose of this study was to investigate the occurrence of maxillofacial injuries and attitude of college sports player in Korea towards mouthguard. Material and methods: Total 617 athletes answered a series of questionnaire concerning their sports injury and using mouthguard. Results: 1. 81%(502) of athletes had, playing or training a sports, suffered an injury. Female athletes suffered an injury more than male athletes(p<0.05). Contact sports athletes were injured more than non contact sports athletes(p<0.05). 2. 335 athletes(54.8%) had suffered maxillofacial injuries while playing or training. 81.8% of athletes suffered an maxillofacial injury in contact sports(p<0.05). 3. Laceration of oral area, wrick in neck, fracture or avulsion on upper incisors, concussion, TMJ injury, fracture or avulsion on lower incisors, fracture or avulsion on lower molars were frequently injured area. 4. 67.2% of athletes answered that mouthguard could prevent sports injury especially high in contact sports(p<0.05). But only 39.1% of athletes required mouthguard while playing. 44.6% of athletes showed their intention of using mouthguard. Conclusion: This study shows that the incidence of maxillofacial injuries is very high while the actual use of mouthguard is very low. To prevent sports injury, a dentist must inform sports players and coaches of accurate information about mouthguard so that they can use it well. A dentist also has to provide them with better mouthguard on the basis of user's complaint.

THREE-DIMENTIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION FOR DIFFERENT IMPLANT THREAD SLOPE (임플랜트 나사선 경사각이 치조골 응력 분포에 미치는 영향)

  • Seo, Young-Hun;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.482-491
    • /
    • 2007
  • Statement of problem: The screws of dental implant, having various thread types, can be categorized into different classes by their geometrical form, and each type transmits dissimilar amount and form of stress to alveolar bone. Purpose: The purpose of this study was to find an inclination angle of the screw thread that is favorable in distributing the stresses to alveolar bone. Material and methods: In this study, We used three dimensional finite element analysis with modeling having three types of thread inclination angles and fixed pitch-0.8 mm (single thread type with $3.8^{\circ}$ inclination, double thread type with $7.7^{\circ}$ inclination, triple thread type with $11.5^{\circ}$ inclination). Results: The results obtained from this study were as follows; 1. When the number of thread increased, the amount of Von-Mises stress was reduced since the generated stress was effectively distributed. 2. Since the maximum principal stress affects on the alveolar bone can influence deeply on the longevity of the implants when comparing the magnitude of the maximum principal stress double thread had least amount of stress. This shows that the double thread screw gave best result. Conclusion: In conclusion, double, and triple thread screws were found to be more effective on distribution of the stress than the single thread screws. But, increasing in the thread inclination angle such as triple thread screw relate on the magnitude of the maximum principal stress affecting on the alveolar bone can become problematic. Thus, effective combination of thread number and thread inclination angle can help prolonging the longevity of implant.

Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study

  • Pahuja, Rasleen Kaur;Garg, Sandeep;Bansal, Sanjay;Dang, Rajat Harvinder
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.270-277
    • /
    • 2013
  • PURPOSE. This study was aimed to determine the effect of two chemically distinct denture cleansers and water on the surface hardness of acrylic and silicone based soft denture liners at various time intervals. MATERIALS AND METHODS. Two commonly used commercial resilient liner material were selected based on their chemical composition (silicone- and acrylic-based soft liners) for this investigation. 120 cylindrical specimens were made of $15mm{\times}10mm$ dimensions (according to ASTM: D-2240-64T) in a custom made metal mold. All specimens were stored in artificial saliva throughout the study. Forty specimens were cleansed daily in 0.5% sodium hypochlorite solution; forty were cleansed in sodium perborate and remaining forty specimens were daily rinsed in water. Testing was done at 1 week, 1 month, 3 months and 6 months for surface hardness using a Shore A Durometer. A mean of 3 reading for each sample was subjected to one-way ANOVA, Post Hoc test and pair-t test for statistical analysis. P values of less than 0.05 were taken as statistically significant. RESULTS. Surface hardness of all the samples was significantly higher after a period of 6 months irrespective of the cleansing treatment. Minor changes were observed between control, sodium hypochlorite and sodium perborate groups with time. Greater change was observed in surface hardness of acrylic-based soft denture liners as compared to silicone-based soft liners for all groups, as time progressed. CONCLUSION. Silicone-based soft denture liners performed significantly better in all cleansing treatments than acrylic-based soft denture liners.

Stress distribution in premolars restored with inlays or onlays: 3D finite element analysis

  • Yang, Hongso;Park, Chan;Shin, Jin-Ho;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Chung, Hyunju
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.184-190
    • /
    • 2018
  • PURPOSE. To analyze stress distribution in premolars restored with inlays or onlays using various materials. MATERIALS AND METHODS. Three-dimensional maxillary premolar models of abutments were designed to include the following: 1) inlay with O cavity (O group), 2) inlay with MO cavity (MO group), 3) inlay with MOD cavity (MOD group), and 4) onlay (ONLAY group). A restoration of each inlay or onlay cavity was simulated using gold alloy, e.max ceramic, or composite resin for restoration. To simulate masticatory forces, a total of 140 N static axial force was applied onto the tooth at the occlusal contact areas. A finite element analysis was performed to predict the magnitude and pattern of stresses generated by occlusal loading. RESULTS. Maximum von Mises stress values generated in the abutment teeth of the ONLAY group were ranged from 26.1 to 26.8 MPa, which were significantly lower than those of inlay groups (O group: 260.3-260.7 MPa; MO group: 252.1-262.4 MPa; MOD group: 281.4-298.8 MPa). Maximum von Mises stresses generated with ceramic, gold, and composite restorations were 280.1, 269.9, and 286.6 MPa, respectively, in the MOD group. They were 252.2, 248.0, 255.1 MPa, respectively, in the ONLAY group. CONCLUSION. The onlay design (ONLAY group) protected tooth structures more effectively than inlay designs (O, MO, and MOD groups). However, stress magnitudes in restorations with various dental materials exhibited no significant difference among groups (O, MO, MOD, ONLAY).

Shear bond strength of composite resin to high performance polymer PEKK according to surface treatments and bonding materials

  • Lee, Ki-Sun;Shin, Myoung-Sik;Lee, Jeong-Yol;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.350-357
    • /
    • 2017
  • PURPOSE. The object of the present study was to evaluate the shear bonding strength of composite to PEKK by applying several methods of surface treatment associated with various bonding materials. MATERIALS AND METHODS. One hundred and fifty PEKK specimens were assigned randomly to fifteen groups (n = 10) with the combination of three different surface treatments (95% sulfuric acid etching, airborne abrasion with $50{\mu}m$ alumina, and airborne abrasion with $110{\mu}m$ silica-coating alumina) and five different bonding materials (Luxatemp Glaze & Bond, Visio.link, All-Bond Universal, Single Bond Universal, and Monobond Plus with Heliobond). After surface treatment, surface roughness and contact angles were examined. Topography modifications after surface treatment were assessed with scanning electron microscopy. Resin composite was mounted on each specimen and then subjected to shear bond strength (SBS) test. SBS data were analyzed statistically using two-way ANOVA, and post-hoc Tukey's test (P<.05). RESULTS. Regardless of bonding materials, mechanical surface treatment groups yielded significantly higher shear bonding strength values than chemical surface treatment groups. Unlike other adhesives, MDP and silane containing self-etching universal adhesive (Single Bond Universal) showed an effective shear bonding strength regardless of surface treatment method. CONCLUSION. Mechanical surface treatment behaves better in terms of PEKK bonding. In addition, self-etching universal adhesive (Single Bond Universal) can be an alternative bonding material to PEKK irrespective of surface treatment method.