• Title/Summary/Keyword: dental implant

Search Result 2,722, Processing Time 0.031 seconds

Implant success rates in full-arch rehabilitations supported by upright and tilted implants: a retrospective investigation with up to five years of follow-up

  • Francetti, Luca;Rodolfi, Andrea;Barbaro, Bruno;Taschieri, Silvio;Cavalli, Nicolo;Corbella, Stefano
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.6
    • /
    • pp.210-215
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to investigate the cumulative success rate, the implant survival rate, and the occurrence of biological complications in implants supporting full-arch immediately loaded rehabilitations supported by upright and tilted implants. Methods: The clinical records and periapical radiographs of patients who attended follow-up visits were collected, and information was recorded regarding marginal bone loss resorption, the occurrence of peri-implant infectious diseases, and the implant survival rate. Implants were classified as successful or not successful according to two distinct classifications for implant success. Results: A total of 53 maxillary and mandibular restorations including 212 implants were analysed, of which 56 implants were studied over the full five-year follow-up period. After five years, the cumulative success rate was 76.04% according to the Misch classification and 56.34% according to the Albrektsson classification. The cumulative implant survival rate was 100%, although one implant was found to be affected by peri-implantitis at the second follow-up visit. Conclusions: The cumulative success rate of the implants dropped over time, corresponding to the progression of marginal bone resorption. The prevalence of peri-implantitis was very low, and the implant survival rate was not found to be related to the cumulative success rate.

Evaluation of fitness in implant screw as tightening torque in dental laboratory (기공실에서의 임플란트 토크값에 따른 적합도 평가)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.310-315
    • /
    • 2015
  • Purpose: The purpose of this study was to measure the tightening torque for dental implant in dental laboratory and to analyze of the effects of different tightening torque. Materials and Methods: The tightening torque for dental implant in dental laboratory were measured by digital torque gauge. The length of abutment and analog were measured as tightening torque of manufacturer's instructions and the measured value. And the data were statically analyzed. Results: The mean tightening torque of implant screw in dental laboratory was $1.563{\pm}0.332Ncm$. The external type implant system of total length were showing no significant differences but the internal type implant system had difference significant (P < 0.05) when compared with tightening torque. Conclusion: The implant prosthesis should be made under manufacturer's instructions especially as tightening torque of screw. For the fidelity of implant prosthesis, dental technician should learn how to use the torque gauge.

Retrospective study of conical connection dental implant (Ankylos dental Implant). (Conical connection 임프란트(Ankylos dental implant)에 대한 후향적 임상연구)

  • Yang, Byoung-Eun;Song, Sang-Hun;Shim, Hye-Won;Lee, Sang-Min;Kim, Seong-Gon
    • The Journal of the Korean dental association
    • /
    • v.44 no.11 s.450
    • /
    • pp.739-747
    • /
    • 2006
  • Objectives. The standardization of connection between fixture and abutment has not been defined. The success of dental implants was not always depends on connection. However, the connection mechanism is one of the most important things for dental implant treatment success. Most implant systems are very comparable in their design and engineering. They share many common characteristics and have similar strengths and weaknesses. Their significant weaknesses are connection, microgap and the resulting micromovement allowing bacterial contamination and bone loss. In the present study, we investigated the clinical performance of Ankylos implant (conical connection implant) Patients and Methods. The clinical performance of conical connection implant was studied under well-controlled clinical conditions. A total of 133 conical connection implants were placed in 50 patients from April 2005 to March 2006. The mean follow-up loading period of implants which was considered successful was 220$\pm$29 days. We recorded the age, sex, installation site, reason of edentulous region, bone density of installation site, diameter and length of dental implants and periods from installation to uncovering surgery using patients medical chart. Results Four Ankylos implants were lost during pre-loading period. 129 implants provided excellent clinical performance during 220$\pm$29 days on an average. The short-term success rate of this conical connection implant system was 96.99%.

  • PDF

Occlusal concepts and considerations in implant supported prosthesis (임플란트 지지 보철물의 교합양식 및 고려사항)

  • Baek, Yeon-Wha;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • The Journal of the Korean dental association
    • /
    • v.58 no.8
    • /
    • pp.496-504
    • /
    • 2020
  • The osseointegrated implants react biomechanically in a different pattern to occlusal force, due to lack of the periodontal ligament unlike the natural teeth. The implants show markedly less movement and limited tactile sensitivity compared with the natural teeth. The implant occlusion concept aims to avoid overloading on the implants and to direct occlusal loads along the longitudinal axis of the implants, in order to compensate for the different biomechanics of the implants. Although many guidelines and theories on implant occlusion have been proposed, few have provided strong supportive evidence. Moreover, the outcome of treatment often quite successful in spite of different concepts of occlusion and there is an increasing tendency to doubt about the strict theoretical implant-specific occlusion concept. The purpose of this article is to review the previous reports about the concept of implant occlusion and discuss clinical occlusal considerations in implant rehabilitations.

  • PDF

Attitude and treatment options in implant-supported prosthetics: A survey among a cohort of German dentists

  • Glucker, Carolin;Rauch, Angelika;Hahnel, Sebastian
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • PURPOSE. The aim of the current study was to analyze treatment concepts of a cohort of German dentists for planning, fabrication, and maintenance of implant-supported fixed and removable restorations. MATERIALS AND METHODS. A questionnaire including queries about experiences with implant-supported restorations as well as prosthetic and maintenance treatment concepts for supplying patients with fixed and removable implant-supported prosthetic restorations was developed and sent to 350 dental offices registered in the municipal area of Leipzig, Germany. RESULTS. An overall total of 62 returned questionnaires were included in the analyses, which relates to a response rate of 17.7%. Participating dentists were more involved in the prosthetic aspects of implant dentistry rather than surgery, while prosthetic concepts such as backward planning, digital processing, and application of all-ceramic materials were not commonly performed. Simple attachments were preferred over complex retention systems in removable implant-supported restorations. Tooth/implant-supported fixed denture prostheses as well as removable denture prostheses with supporting posterior implants were not regarded as a favorable treatment option. CONCLUSION. Within the limitations of the study, the data indicate that dentists favor simple and conventional treatment approaches in implant prosthetics. Prosthetic aspects in the planning of implant-supported restorations are often neglected. Prosthetic treatment guidelines and aspects should commonly be considered in the planning phase of implant-supported prosthetic restorations, and awareness should be increased in postgraduate education.

Mechanical Analysis of Macro-Hexagon Porous Dental Implant Using Selective Laser Melting Technique (SLM법으로 매크로 육각다공질 구조를 부여한 치과 임플란트의 역학 분석)

  • Kim, Bu-Sob;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.55-61
    • /
    • 2011
  • Purpose: In this study, FEM(Finite Element Method) and bending strength test was conducted using normal implant and porous implant for the mechanical estimation of porous dental implant made by SLM method. Methods: Mechanical characteristics of PI(porous implant) and NI(normal implant) applied distributed loads(200N, 500N) were observed through FEM analysis. And each bending strength was gotten through bending test using MTS(Mechanical Test System, Instron 8871). Results: The result of FEM analysis was observed that stress difference between upper and surface of PI was 12 times, while NI was 2 times. The result of bending test was observed that bending strength of PI was lower than NI. we made a decision about this result that cross-sectional area of NI was larger than the PI. Conclusion: The stress shielding ability of porous implant was better than normal implant through result of FEM analysis. And bending strength of porous implant was lower than NI. We think that cause of this result was difference of cross-sectional area.

Associated factors which influence satisfaction of dental implant patients and intention to revisit using structural equation model (구조방정식 모형을 이용한 치과 임플란트 환자의 만족과 재이용 의사에 미치는 영향요인 분석)

  • Cho, Min-Suk;Yoo, Sung-Jin;Yang, Dong-Hyun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.2
    • /
    • pp.221-230
    • /
    • 2013
  • Objectives : This study is to confirm the influencing factors on patients satisfaction and intention to revisit the implant service clinic by structural equation model. Methods : We surveyed 250 implant patients visiting 6 dental clnics(hospitals) in Busan, Changwon, Gimhae city and questionnaire was for four weeks in July 2012, a total 209 patients filled out the questionnaires within July and the complete data were analyzed. we were used structural equation model for analysis to confirm influencing factors on implant patients' satisfaction and intention to revisits. Results : This study finds that factors influencing on implant patients' satisfaction and intention to revisit are reasonable medical fee, medical skill treatment of dentist, dental hygienist and other support staff, administrative procedure, and there existed between influencing factors and the patient's treatment satisfaction as well as intention to revisit. In order to satisfy the implant patients, dentist and hygienists should try to provide high quality of treatment and dental services. Conclusions : The results of this study provide managerially important messages to the managers of dental clinics in order to develope management strategies for new customers.

A Study on Dental Patients' Knowledge and Attitude about the Implant Denture - Focused on South Gyeongnam Province, South Korea - (치과내원자의 임플란트 시술경험이 지식과 태도에 미치는 영향 - 경남지역을 중심으로 -)

  • Choi, Yu-Jin;Kwon, Su-Jin
    • The Korean Journal of Health Service Management
    • /
    • v.5 no.2
    • /
    • pp.53-62
    • /
    • 2011
  • This study is to inquire into the correlation between patients' knowledge and attitude about the implant denture, as well as to provide exact information for patients. The results are expected to be basic data to make patients have positive attitudes to the implant denture. The study was conducted on patients who visited dental hospitals located in South Gyeongsang Province, South Korea, from 1 November to 31 December, 2009, the answer sheets from 198 patients analyzed. The results showed that 24.2% of respondents had implant dentures put in. Hereat, the t-test and the analysis of variance (ANOVA) were performed to analyze respondents' knowledge and attitude about the implant denture according to general characteristics. In relation to knowledge about the implant denture, respondents showed differences according to what levels of education they had and whether they had the implant dentures put in. The results of a correlation analysis showed that respondents' knowledge and attitude about the implant denture had a significant correlation with each other. In other words, respondents, who had a high degree of knowledge about the implant denture, had a more positive attitude to it. With the generalization of implant dentures, dental care providers have need to provide exact information about the implant denture for dental patients in order that they may comprehend it and have positive attitudes to it. In addition, there is a need to establish a system to provide the general public with exact information about the implant denture.

The occurrence of dental implant malpositioning and related factors: A cross-sectional cone-beam computed tomography survey

  • Safi, Yaser;Amid, Reza;Zadbin, Fariba;Ahsaie, Mitra Ghazizadeh;Mortazavi, Hamed
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.251-260
    • /
    • 2021
  • Purpose: Dental implants are widely used for the rehabilitation of edentulous sites. This study investigated the occurrence of dental implant malpositioning as shown on post-implantation cone-beam computed tomography (CBCT) and to identify related factors. Materials and Methods: Samples with at least 1 malpositioned dental implant were collected from a central radiology clinic in Tehran, Iran from January 2017 to January 2019. Variables such as demographic characteristics, length and diameter of implants, type of implant, sites of implant insertion, different types of implant malpositioning problems (cortical plate perforation, interference with anatomical structures), angulation of the implant, and the severity of malpositioning were assessed. In addition, the incidence of implant fracture and over-drilling was evaluated. Data were statistically analyzed using the chi-square test, 1-sample t-test, and Spearman correlation coefficients. Results: In total, 252 patients referred for implant postoperative CBCT evaluations were assessed. The cases of implant malpositioning included perforation of the buccal cortical plate (19.4%), perforation of the lingual cortical plate (14.3%), implant proximity to an adjacent implant (19.0%), implant proximity to an adjacent tooth (3.2%), interference with anatomical structures(maxillary sinus: 18.3%, mandibular canal: 11.1%, nasal cavity: 6.3%, mental foramen: 5.6%, and incisive canal: 0.4%). Implant fracture and over-drilling were found in 1.6% and 0.8% of cases, respectively. Severity was categorized as mild (9.5%), moderate (35.7%), severe (37.7%), and extreme (17.1%), and 52.4% of implants had inappropriate angulation. Conclusion: CBCT imaging is recommended for detecting dental implant malpositioning. The most common and severe type of malpositioning was buccal cortex perforation.

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period

  • Kim, Hyun-Joo;Kim, Yeun-Kang;Joo, Ji-Young;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.2
    • /
    • pp.106-115
    • /
    • 2017
  • Purpose: The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods: Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results: The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in ${\varnothing}5.0mm$ implants than in ${\varnothing}4.0mm$ implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions: All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.